Col Shery Goel, CWE
HQ CWE Bikaner, Bikaner Mil Stn
Comprehensive and preventive maintenance of lift and boilers of 187 MH at Mil Stn Bikaner
2024_MES_675883_1
CA No CWE BKN-Token No 50/2024-2025
Open Tender
Civil Works
Item Rate
330 days
GE (N) Bikaner
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (N) Bikaner
₹45,220
Yes
12 Dec 2024
21 Sept 2024
21 Oct 2024
21 Sept 2024
19 Oct 2024
5 Oct 2024
21 Sept 2024 - 28 Sept 2024
Amount
Supply and fixing in replacement mechanical laundry shaft including bearing, opening of laundry shaft and after replacement shaft fixing and testing of mechnical laundry complete as specified and as directed.
Comprehensive preventive and periodical maintenance of electric passenger Lift No. 01 of OMEX make lift in G+3 storey in reliably safe and efficient operating condition by regularly examine, lubricating and adjust the equipment and carry out planned maintenance in a systematic and controlled manner of one No 15 passenger lift capacity 1020 Kg speed 1 M/S equipped with microprocessor based AC variable voltage variable frequency controller, AC Motor governor ropes driving sleave, travelling cable working and electric fitting, microprocessor card, rectifier card, controller AC drive, door drive, indication card, SMPS luminous card and hall button and landing door shoe car guide shoe landing, CWT guide shoe landing, transformer, motor bush hooter, FP Card door hanger roller, door sensor, complete all as specified and as directed.
Comprehensive preventive and periodical maintenance of electric passenger Lift No. 02 of OMEX make lift in G+3 storey in reliably safe and efficient operating condition by regularly examine, lubricating and adjust the equipment and carry out planned maintenance in a systematic and controlled manner of one No 15 passenger lift capacity 1020 Kg speed 1 M/S equipped with microprocessor based AC variable voltage variable frequency controller, AC Motor governor ropes driving sleave, travelling cable working and electric fitting, microprocessor card, rectifier card, controller AC drive, door drive, indication card, SMPS luminous card and hall button and landing door shoe car guide shoe landing, CWT guide shoe landing, transformer, motor bush hooter, FP Card door hanger roller, door sensor, complete all as specified and as directed.
Comprehensive preventive and periodical maintenance of electric passenger Lift No. 03 of OMEX make lift in G+3 storey in reliably safe and efficient operating condition by regularly examine, lubricating and adjust the equipment and carry out planned maintenance in a systematic and controlled manner of one No 13 passenger lift capacity 884 Kg speed 1 M/S equipped with microprocessor based AC variable voltage variable frequency controller, AC Motor governor ropes driving sleave, travelling cable working and electric fitting, microprocessor card, rectifier card, controller AC drive, door drive, indication card, SMPS luminous card and hall button and landing door shoe car guide shoe landing, CWT guide shoe landing, transformer, motor bush hooter, FP Card door hanger roller, door sensor, complete all as specified and as directed. Notes :- (a) (i) Labour component required for the replacement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item. (ii) Major parts (as required) shall be measured and paid separately under appropriate items of this Sch 'A'. (iii) T&P for replacement of minor/major parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. (iv) Contractor shall be fully responsible for full functioning of lift 24x7 days. (v) Each Job shall be considered for 02 Months. (b) The above maintenance shall be done through only E-in-C Branch's approved OEM rep or authorised rep or authorised agent of OEM i.e M/S Kone India, M/S Schindier India Pvt Ltd., M/S Kinetic hyundai Elevator & movement tech Ltd., M/S Hitachi Lifts India Pvt Ltd, M/S Mitsubishi Elevator India Pvt Ltd, M/S Otis Elevator Company India Ltd, M/S Fujitech India Pvt Ltd, M/S Johnson Lifts Pvt Ltd, M/S Thyssenkurupp Elevator India Pvt Ltd. M/S Omega Elevators, M/S Escon Elevators Pvt Ltd, M/S LT Elevators Pvt Ltd and M/S IES Elevators or any other OEM approved by E-in-C's Branch.
Notes for Serial item No. 2.00 to 4.00 :- (i) As per E-in-C's Branch OEM (Original Equipment Manufacturer) generated inspection report shall be submitted immediately after conclusion of contract and then at a frequancy of two months by the contractor. (ii) All repairs, overhauling, requirement of spares for repair/replacement under this contract shall be based on inspection report genereated by OEM. (iii) If lift is not operational/break down for period more than 2 days for minor repairs or beyond seven days for major repairs than a penalty @ Rs. 1000/- per day shall be levied on contractor. The offload and onload date and time of breakdown shall be obtained from users. (iv) Regarding the breakdown is major or minor, same shall be decided by GE and the decision of GE in this regard shall be final and binding.
Supply only the following spare parts / components for 13/15 passenger lift G+3 storey in MH bldg required to be replaced under serial item No 2.00 to 4.00 here-in-before, Make :- OMEX Elevators.
Travelling Cable, 5mm
Landing door spring
Car Door Roller
Landing door mechanical lock
Landing door lock contact (Male + Female)
Landing door Key (mechanical)
Push button
Steel door Rope 3mm dia complete with accessories
Door shoe
Rectifier card
Landing door header
Car door hanger
Governor steel rope 8 mm dia
Maintenance box
Flexible copper conductor cable of size 1.5 Sqmm 12 core
Car gate Lock set
Display card
Door seal
Door belt
Limit switch
Read switch
Header roller
Header Incentry
Pully of main machine
Magnet coil
Gate lock
Alarm Hooter
Fire main switch
Steel wire rope 13 mm dia
LOP Switch (Landing Operating Panel)
COP Switch (Car operating panel)
Door Sensor
Fire Switch Glass
Lift master complete
Door coupler
Gear set complete
Main drive complete
Door drive 1.0 HP (Door drive control sensor)
Lift Gear box oil
M&L in replacement main panel for controlling of 13/15 passenger lifts made out of sheet steel metal of size 90cm x 90cm x 25cm indoor with the following accessories (a) PCB - 02 Nos (b) Connector - 05 Nos (c ) Fuse assembly - 01 Set (d) Transformer 300 VA range 230 Volts to 440 Volt - 01 No (e) Single phase preventer type S-B make ADCD - 01 No
M&L for rewinding and refixing of induction motor with suitable guage of super enamelled copper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishing, servicing of ball bearing, suitable main connection from coil to terminal box, opening of motor, cutting /removing old burnt winding coils, cleaning /filling the stater slots, necessary mechanical work for shaft/ bearing housing, preparing and inserting coils running /starting winding, interconnecting, fixing, soldering, jointing, heating, drying up coils, connection and testing at site, satisfactory running of motor of capacity 12.5 HP, 3 Phase, 440 Volts, 50 Hz, complete all as specified and as directed.
M&L for rewinding and refixing of induction motor with suitable guage of super enamelled copper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishing, servicing of ball bearing, suitable main connection from coil to terminal box, opening of motor, cutting /removing old burnt winding coils, cleaning /filling the stater slots, necessary mechanical work for shaft/ bearing housing, preparing and inserting coils running /starting winding, interconnecting, fixing, soldering, jointing, heating, drying up coils, connection and testing at site, satisfactory running of motor of capacity 15 HP, 3 Phase, 440 Volts, 50 Hz, complete all as specified and as directed.
Comprehensive preventive and periodical maintenance (Revomax) of boiler (02 Nos) of capacity 200 Kg, steam pressure 5.5-7.5 Kg/sqcm and water consumption 200 Ltrs/Hr, regular examine, lubricating and adjust equipment and carry out planned maintenance in a systematic and controlled manner complete all as specified and as directed. Notes :- (a) (i) Labour component required for the replacement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item. (ii) Major parts (as required) shall be measured and paid separately under appropriate items of this Sch 'A'. (iii) T&P for replacement of minor/major parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. (iv) Contractor shall be fully responsible for full functioning of boilers 24x7 days. (v) Each Job shall be considered for 02 Months. (vi) OEM (Original Equipment Manufacturer) generated inspection report shall be submitted immediately after conclusion of contract and then at a frequancy of three months by the contractor. (vii) All repairs, overhauling, requirement of spares for repair/replacement under this contract shall be based on inspection report genereated by OEM. (viii) If boilers are not operational/break down for period more than 2 days for minor repairs or beyond seven days for major repairs than a penalty @ Rs. 1000/- per day shall be levied on contractor. The offload and onload date and time of breakdown shall be obtained from users. (ix) Regarding the breakdown is major or minor, same shall be decided by GE and the decision of GE in this regard shall be final and binding.
Supply only the following spare parts/components for boiler in MH bldg required to be replaced under serial item No. 9.00 here-in-before, Make :- REVOMAX.
Hose pipe
Pneumatic Valve
Display board
Steam solenoid valve
Gas kit complete set
Motor Coil 1.5 HP
Temperatore Controller
Nozzle
Oil Pump
Photo Cell
Safety Valve
Stop Valve
V-Belt
Descalling Chemicals
Relay
Oil Seal
Sequence Controller
UV Cell
Pressure Gauge 300 psi
Globe Valve
Contactor 18 Amp
Streem Trap 1"
Electrode Rods
Asbestos Rope
Comprehensive preventive and periodical maintenance of mechanical laundry by the reprentative of company (Make - Fabecare), 03 Nos, Drying tumbler 30 Kg capacity (02 Nos) and 03 Nos of Flat iron machines regularly examine, lubricating and adjust the equipment and replacement of unserviceable parts, fuel pump coupling, burner blow, limit switch, Diesel filter, timer ignition/ sparking rod, pressure gauge, tempreature controller, etc and made functional including carryout planned maintenance in a systematic and controlled manner complete all as specified and as directed. Notes :- (a) (i) Labour component required for the replacement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item. (ii) Major parts (as required) shall be measured and paid separately under appropriate items of this Sch 'A'. (iii) T&P for replacement of minor/major parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. (iv) Contractor shall be fully responsible for full functioning of laundry 24x7 days. (v) Each Job shall be considered for 02 Months. (vi) The rate for replacement of Elbow 2mmx8mm, nipple 2mmx 8mm, PU pipe 8mm dia, reducer, nuts, bolts, washers, etc minor parts shall be deemed to be included in the unit rate quoted against this item. (vii) OEM (Original Equipment Manufacturer) generated inspection report shall be submitted immediately after conclusion of contract and then at a frequancy of three months by the contractor. (viii) All repairs, overhauling, requirement of spares for repair/replacement under this contract shall be based on inspection report genereated by OEM. (ix) If mechanical laundry, Drying tumbler, Flat iron machines, etc are not operational/break down for period more than 2 days for minor repairs or beyond seven days for major repairs than a penalty @ Rs. 1000/- per day shall be levied on contractor. The offload and onload date and time of breakdown shall be obtained from users. (x) Regarding the breakdown is major or minor, same shall be decided by GE and the decision of GE in this regard shall be final and binding.
Supply only the following spare parts/components for Mechanical laundry 30 Kg washer Extractor in MH bldg required to be replaced under serial item No. 11.00 here-in-before, Make :- FABECARE.
Wash starker
Solenoid valve
Hose pipe
Angle valve
Power Display
Oil seal 'O' ring
Rubber Hose Pipe 3 x 1 metre
Rubber Hose Pipe 2 x 1 metre
V-Belt (B-92)
Door gasket
Pneumatic Valve 3"
Pneumatic Valve 2"
Steam Valve 1"
Door Lock
Metalic steam house pipe 1"
Shock absorbers
FRL unit (Filter, Regulator and Lubricator Unit) 1/4" (8mm)
Supply only the following spare parts/components for heating system boiler - 02 Nos of cap 200 Kg, steam pressure 5.5 -7.5 Kg/sqcm and water consumption 200 Ltrs/Hr at 187 MH bldg required to be replaced under serial item No. 9.00 here-in-before, Make :- REVOMAX.
Burner fuel pipe
Diesel pipe
Hose pipe
Diesel filter
Coupling shaft
Coupling belt
Steam saftey valve
Pneumatic Actuator, make Aira
Water feed pump
Gate valve of size 25 mm dia
Burner rod assembly
Oil spray nozzel
Boiler pressure switch
Water Pump
Sequence Controller
Photo Cell with Socket
Temperatore Controller
Contactor Safety
Nozzle
Descalling Chemical energy flock 1110
Water Seal
Valve Set Assy
Water level switch
Bearing Make- SKF/NBC/TATA
Supply only the following spare parts/components for flat Iron Machine in repair of serial item No. 11.00 here-in-before :-
Single phase preventer (VSPD-I)
Steam angle valve 1/2"
Bearing Make- SKF/NBC/TATA
M&L for Chest Cleaning or polishing flat Iron Machine complete all as specified and directed.
M&L for greasing, oiling and servicing/ overhauling complete including replacement of all connected items complete to make servicable 30 Kg drying tumbler machine (02 Nos) complete all as specified and directed.
M&L in replacement Contactor, 3 Pole, 32 Amp, AC operated, 415 Volt complete all as specified and directed. Make : Type ML-2 of L&T or equivalent in makes mentioned in Appendix 'B' here-in-after.
Supply and fixing in replacement LED fitting low height downlighter 12 Watt, CCT 5700K, complete with standard profile linear LED lighting fixture, prewired and connecting up with & including 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, with all accessories and following specifications complete all as specified & as directed :- (a) Lumen efficacy of luminaire shall be minimum 100 lumen per watt. (b) Voltage operating range : 160 to 270 Volts. (c) Temp operating range : Minus 10 degree C to Plus 50 degree C. (d) Power Factor : Minimum 0.95 (e) THD : Max 10% (f) IP rating : IP-65 (g) CRCA pre coated housing (h) LED driver
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, including taking up or down existing unserviceable steel water tubing and connections of 25mm bore complete all as specified and as directed. complete all as specified and as directed.
S&F in repairs 25mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified & as directed.
J D ENTERPRISES (BID ID -3144232)
GURBUX SINGH AND CO. (BID ID -3136211)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .