Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-Finance LOWEST TENDERER | |
| 2 | L2₹39.8 L+₹4.4 L (12.5%)Rejected-Finance | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹42.8 L+₹7.4 L (20.8%)Rejected-Finance BHAIRAVNATH NAGAR AT KUSGAON POST LONAVLA 410 401 DISTT PUNE | PUNE | MAHARASHTRA | 410401 | L3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L4₹42.9 L+₹7.5 L (21.1%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L4 | Rejected-Finance GREATER THAN L1 | |
| 5 | L5₹44.1 L+₹8.7 L (24.5%)Rejected-Finance 601 A WING SAI PARAMOUNT APARTMENT SHRADDHA VIHAR COLONY INDIRANAGAR NASHIK NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | L5 | Rejected-Finance GREATER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
19 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Komal Parihar
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
ADDITION ALTERATION AND IMPROVEMENTS TO BLDG NO P 349 VIKRANT BLOCK P 132 P 133 P 137 BRAHMAPUTRA GALLEY BRAHAMPUTRA I AND II BLOCK AT INS SHIVAJI LONAVLA
2021_MES_439307_1
GE/LONAVLA/8983/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
4 documents required · 4 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹95,000
Yes
21 May 2021
29 Apr 2021
21 May 2021
29 Apr 2021
19 May 2021
5 May 2021
29 Apr 2021 - 3 May 2021
60 days
Amount
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc of any height as directed by Engg-In-Charge
M&L for Rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat and finished rough to receive wall claddings/ cladding tiles complete all as specified.
S&F 16 to 18mm Dholpur stone cladding gang saw out with machine out edges, uniform colour of each stone size exceeding 0.25 Sqm area fixed with and including one number SS clamps (grade-202) of min 30mm wide, 2mm thick and 150mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment all around to ensure water seepage all as specified and as directed
M&L for Rendering 20 mm thick cement plaster in two coats, first coat 12mm thick in CM 1:6 and second coat 8mm thick in CM1:4 with approved waterproofing compound on brick work /concrete sufaces finished even smooth on external surfaces of walls.
Supply only Integral water proofing compound
M&L preparation of new plastered surfaces/ complete removal of existing treatment on old plastered wall including removing fungus/ algae dirt, oil, grease and loose particles by wire brush, cleaning, washing and removing dust and cracks more than 5mm shall be sealed with "Pidilite URP" manufactured by DR Fixit or with "Plaster seal" manufactured by STP and cracks more than 2mm and less than 5mm shall be sealed with " crack X powder" manufactured by Dr.Fixit or "Plaster seal" manufactured by STP and applying primer and two coats of water proof decorative elastomeric coating of approved shade/colour complete all as specified and as directed. Note :- (i) Primer shall be "Prime seal" manufactured by DR Fixit or "Plaster seal" manufactured by STP. (ii) Water proofing decorative elastomeric coat shall be Rain coat DFT 100 manufactured by Dr Fixit or Shalicry 215 manufactured by STP. (iii) The rate of application of primer and waterproofing coat shall be as per manufacturers instructions. (iv) A time gap of eight hours shall be maintained between the application primer and each water proof coat after application of sealant. (v) Unit rate quoted shall be deemed to include for necessary scaffolding for execution of the same.
M&L for complete removal of old existing treatment and applying two coats of Oil Bound Distemper over a coat of alkali resistant Primer over 3mm thick putty of approved make all as specified and as directed.
M&L for Preparing old painted surfaces/ untreated surfaces of steel any description, over 10cm in width or grith, not otherwise described and applying one coats of Synthetic enamel paint complete all as specified and directed.,
Chipping, removing, carefully loose plasetr, concrete work by low impact Hasmmer / breaker without damaging the structure & cleaning and disposal of malba out side the premises etc complere as directed by Engr-In-Charge. Hard concrete should not be removed by force.
Cleaning exposed reinforced bars throughly to remove corrosion scale using buffle wheel and emery cloth with water jet and allying two coats of nitozinc primer (Make : Fosroc or equivalent)
Providing 50x50x4mm welded mesh coated with anti corrosive chemical to exposed bars using binding wire all as specified and as directed.
Providing and applying structural grade epoxy latex bond coat prior to application of any type of mortarconfirming to ASTM-C-882-91 (Arizona slant shear test) to ensure bondbetween old and new c oncrete by brush applocation (Pidilite/ Fosroc/ Shalimar)
Building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1cement: 3 part graded clened pre packed river sand 10% latex mortar by weight of cement 0.5 w/c ratio) in 20 mm thickness including levelling profilling etc complete Make- Pidilite/ Fosroc/ Shalimar
Supply and application of rust remover / converter (rebaklense RR of M/s Fosroc chemicals India ltd or Amandur (Manufactured by GK Technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after aplication incl cost of all materials rent of tools scafolding cost of brushes etc complete all as specified and directed by EIC
Supply and application of Nitozinc primer ( Manufactured by M/s fosroc chemicals India ltd) over the exposed steel from the exposed reinforcement after removing rods scales from the exposed reinforcement rods in one Sqm area including the cost of all materials ren of tools scaffolding cost of paint complete all as specified and directed by the EIC
Supplying and application of Nitcobond EP (Manufactured by M/s fosroc chemicals India ltd) epoxy bonding agent over the old concrete surfaces including the cost of all materials rent of tolls scaffolding cost of paint brush etc all complete as specified and directed by EIC
Providing additional reinforcement bars in place of more than 1/3 corroded reinforcement bars incl the charges for cutting bending placing and fixing in position using Lok-fix (Manufactured by M/s fosroc chemicals India ltd) including the cost of all materials labour cost of steel bars and scaffolding complete all as specified and directed by the EIC
Supplying and provisioning renderoc RG (Manufactured by M/s Fosroc chemicals Inda ltd) to an average thickness of 70 mm for beam and column fluid micro concrete shall be mixed with 6 mm down course aggregate and specified quantity of water and mixed using a power operated slow speed stirrer and pouring inside the form work and labour charges complete all as specified and directed by the EIC
M&L for preparation of old plastered surface of ceiling surface and applying three coats of white wash etc all as specified and directed.
Dismantling of cast iron/PVC or reinforced concrete drain pipes, jointed in cement mortor and taking out of trenches/wall if required 100/75 mm internal dia pipe complete all as specified.
S&F PVC (SWR) pipes of dia 110mm bore single socketed in any length with rubber ring joints fixed to walls with suitable GI Clamps
S&F PVC (SWR) pipe of 75 mm bore in single socketed in any length with rubber ring joints fixed to walls with suitable GI Clamps
S&F PVC (SWR) bends of 75 mm dia bore
S&F PVC (SWR) bends of 110 mm dia bore
S&F PVC(SWR) vent cowl of 75mm dia bore.
S&F PVC(SWR) vent cowl of 110mm dia bore.
S&F PVC (SWR) branch piece, single (single Y) equal or unequal 75 mm dia
S&F PVC (SWR) branch piece, single (single Y) equal or unequal 110 mm dia
S&F PVC (SWR) branch piece, single (double Y) equal or unequal 75 mm dia
S&F PVC (SWR) branch piece, double (double Y) equal or unequal for 110 mm dia
S&F PVC (SWR) bends of 75mm dia bore with access door
S&F PVC (SWR) bends of 110 mm dia bore with access door
S&F in repairs High density polythylene (HDPE) pipes 50 mm dia, of pressure rating 6 Kg/sq cm, fixed to walls, ceilings or in floors complete all as specified and as directed.
S&F for Renewing glazed wall tiles in patches, area n exc 5 sq. m. including cutting out broken tiles, removing and cleaning loose tiles, preparing bed, removing rubbish and replacing old with new tiles to match, complete with all cuttings, etc. and laying or setting, jointing and pointing new or old tiles complete
Cutting holes in brick wall or stone walls built in cement mortor for inserting hold fast and making good the disturbed portion in cement mortor 1:3 or cement concrete (1:2:4), type B1 as requried for depth of embedded portion of hold fasts or lugs measured from the face of the Jamb into the wall exc half brick & N.exc one brick all as specified and as directed.
S&F PVC Nahani trap100mm size with grating including hacking out cement joints and jointing to existing pipes/ waste pipe fixed in cement concrete type type B1 (1:2:4)
Removing building materilas such as bricks, stones, concrete, sand etc to a distance upto 15Km, beyond the lead included in the rates, including loading, unloading and stacking at the destination.
Taking up or down steel tubing 15 mm and connection, including cleaning for refixing or removal to store complete all as specified.
Taking up or down steel tubing 25mm and connection, including cleaning for refixing or removal to store complete all as specified.
Taking up or down steel tubing 40 mm and connection, including cleaning for refixing or removal to store complete all as specified.
S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6 kgf/sqcm conforming to IS-15778 with all fittings such as Tee,Bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure
S&F CPVC pipes, SDR 11, 25 mm outer dia of pressure rating 6 kgf/sqcm conforming to IS-15778 with all fittings such as Tee,Bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure
S&F CPVC pipes, SDR 11, 40 mm outer dia of pressure rating 6 kgf/sqcm conforming to IS-15778 with all fittings such as Tee,Bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure
S&F Bib taps 15 mm dia, fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm dia pipe fixed in repairs Make Cera – Cat No. F2006151 or Equivalent
S&F Stop valves 15 mm dia, fancy type chromium plated, screwed down, high pressure, screwed both ends for 15mm dia pipe or for unions fixed in repairs
S & F PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified.
S&F Brass chromium plated overhead shower rose 120 mm dia with 3 flow with swivel joint, including shower arm, fixing to steel pipe or union including taking down old shower rose complete all as directed and specified by Engr- in- Charge. Make Cera shower rose F7020305 shower arm F7040104 or equivalent in Hindware/ Parryware.all as specified and directed
CP hand Health faucet of brass body with wall hook and 1mtr stainless steel braided rubber hose pipe fixed in repair complete all as specified and as directed.Make: Cera Cat No F8030102 or equivalent in Hindware / Parryware.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth; for foundation , etc or for shafts, wells, cesspits, manholes, pair holes, etc n.exc 10 Sqm on plan and n.exc 1.5 in depth and getting out in hard/dense soil.
Demolition of stone/brick work built in cement mortar.
M/L for brick work with subclass 'B' bricks, straight, or curved on plan exc 6m mean radius built in CM 1:4
Rendering 15mm thick on fair faces of brick work or concrete surfaces finished fair and even (without using extra cement) in CM 1:3 etc complete.
M&L rendering in CM (1:4) 15mm thickness on fair face of brick/concrete surfaces mixed with water proofing compound finished even and smooth without using extra cement (water proofing compound measured separately).
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of manhole including watering slightly rounded, including necessary form work.
M/L for PCC 1:2:4 type B0 (Using 12.5mm graded stone agg) as in benching, forming of channel etc complete.
Dismantling of cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required of size 150mm.
all as per item No 56 above but 200mm dia of pipe.
M/L for 200mm dia reinforced concrete pipes, class NP-2 laid and jointed complete with collars etc complete all as specified and directed by Engr-in-charge.
all as per item No.56 above but 200mm dia of pipe.
Returning filling in, including, spreading levelling watering and well ramming in layers not exc 25cm in soft/loose soil etc complete.
Removing excavated material exc 250m but n.exc 500m and depositing where directed as in soils.
M/L for PCC 1:3:6 type C-2 concrete bed to drain pipes of dia 150mm incl, packing under and haunching against the sides of pipes after they are laid and tested etc complete.
All as per item No 62 above but 200mm dia of pipe.
M/L cutting into existing manholes for connecting new drains, of 150mm dia welding good to pipe incl rendering, cutting out existing benching for and forming branch channel (1/2 round on 3/4 section in cement concrete 1:2;4 type B1 smooth finished and reforming benching as reqired.
All as per item No 64 but 200mm dia
S& F in repairs Salt-glazed stoneware gully traps, square or round mouthed, type `P' 150 x 150mm
RK AND SONS CREATION
seema enterprises
SHAILENDRA B TULSANI
SAI SAMARTH ENTERPRISES
M/s RAJKUMAR MANIKRAO PATIL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .