| 1 | L1₹8.2 LAccepted-AOC E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.5 L+₹1.0 L (12.3%)Rejected-Finance 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹9.6 L+₹1.2 L (13.7%)Rejected-Finance POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹9.9 L+₹1.5 L (17.5%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
23 Aug 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ABHISHEK KUMAR YADAV,IDSE
AGE I AF SINGARSI
Repair Maintenance of internal wiring replacement of MCBS DBS in OTM Accn including Repair Maint of cooling appliances at AF Stn Singarsi under AGE I AF Singarsi
2022_MES_534358_3
C/8559/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹17,000
Yes
2 Sept 2022
6 Aug 2022
24 Aug 2022
7 Aug 2022
23 Aug 2022
8 Aug 2022
Amount
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and fittings complete and making good the disturbed surfaces all as directed by Engineer-in-Charge.
M&L for point wiring for one light/fan/bell with single core PVC insulated and unsheathed stranded FRLS copper conductor cable 1100 volts grade size 1.5 Sqmm (nominal area) in and including PVC casing capping 25/20 mm width with one single core PVC insulated unsheathed 1.5 Sqmm (nominal area) stranded FRLS copper conductor as earth continuity wire and connected to earth dolly including PVC/wooden switch board on existing wall surface for one light/fan point /bell point controlled by one number one way switch & making good the disturbed surface to match with existing surface/wall complete all as directed by Engineer-in-Charge.
All as per Item No 2 here-in-before but for one 5 pin socket outlet 5 Amps on independent board with 1.5 Sqmm.
All as per item No 2 here-in-before but for one 5 pin socket outlet 5 Amps on the same board with other switches.
All as per Item No 2 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 4 Sqmm copper cable FRLS & 2.5 Sqmm FRLS copper cable for earth continuity wire.
S&F for switch piano flush type 5 Amp single pole one way complete all as specified and as directed.
S&F for socket flush type 5 Amp 5 Pin complete all as specified and as directed.
S&F for switch socket combination 5 Pin 5 Amp universal complete all as specified and as directed.
S&F for switch socket combination 5 Pin, 5/15 Amp universal complete all as specified and as directed.
M&L for ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed.
S & F call bell, ding dong AC 230 volts, single pole complete all as specified and as directed.
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour,complete all as specified and as directed. (Make:Havells ,Hager,Schneider or Legrands).
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour,complete all as specified and as directed. (Make:Havells ,Hager,Schineder or Legrands).
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCCB’s/MCB'S/Isolators, 240 Volt, Vertical TPN DB's 4 way with built in160A rated bus bar and with out MCCB complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour, complete all as specified and as directed.(Make: Hager cat No: VYV04DN-P,Siemens or Legrands).11940
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 25KA complete all as specified and as directed. (Make:Hager ,Schnieder or Legrands).
M&L for MCB, SP, 240V, 40 Amps and ' B ' series breaking capacity 10 KA ISI marked complete all as specified and as directed.
M&L for MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked, complete all as specified and as directed.
M&L for MCB, SPN, 240 V, 40 Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked , complete all as specified and as directed.
S&F ceiling fan regulator electronic Step type, solid state, 100W, 240 volts, complete all as specified and as directed.
M&L for lamp holder PVC/poly carbonate with back plate suitable for batten fittings complete all as specified and as directed. (Make Penta/anchor/plaza)
S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush mounting enclosure with 2 pin earth plug socket complete all as specified and as directed.(Make - Havells Hager/legrand)
S&F in replacement of existing energy efficient tube light fitting of capacity 20 W suspended type / wall mounted type complete convet to LED fitting and copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length complete all as specified and as directed by Engr-in-charge. ( Make :Crompton /Bajaj/,Havells)
M&L for replacement of sub main wiring with 2 run of 2.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/caping (25mm dia) including size 2.5 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface, complete all as specified and as directed by Engr-in-charge.( NOTE :- Two runs of 4 Sqmm pvc wire, one run of 2.5 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit
Supply and fixing sub main wiring with two run of single core 4 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through PVC casing caping with all fittings including 2.5 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping all as specified and as directed. Note : (i) Two run of single core cable 4 sq mm and one run earth wire 2.5 sq mm will be measured as one length.(Make: RR,KEI and Finolex for copper Cable and Prestoplast/Plaza for casing/conduit)
M&L for dismantling the split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton in various location, shifting to MES Yard for repair/replacement of unserviceable spares and servicing, cleaning of filter (if not replaced) of window type AC of any capacity by vacuum cleaner/water spray/mild liquid soap cleaning the front grill by soft cleanser (Colin etc) and painting the outer cabinet by enamel paint and sticking a sticker mentioning “the MES Number and reassembling, testing, checking and shifted to existing location/new location as directed, fixing the same by nut, bolt, angle iron structure and masonry work all as directed & specified by Engineer-in-Charge. (NOTE: The spare parts Including replacing of starting capacitor, running capacitor, over load protection relay , compressor, condensing coil measured & paid separately).
S&F new compressor seal unit of suitable capacity/model in the unit properly for 1.5 TR split type AC complete all as specified and directed by Engr-in-charge.
S&F new compressor seal unit of suitable capacity/model in the unit properly for 2 TR split type AC complete all as specified and directed by Engr-in-charge.
Supply & charge of refrigerant gas R-22/R-140a/R-32 complete all as specified and directed by Engr-in-charge.
Supply & charge of refrigerant gas 134A complete all as specified and directed by Engr-in-charge.
M&L for replacement of capillary tube and stainer for split AC of 1.5 ton/2.0 ton capacity complete all as specified and directed by Engr-in-charge.
Supply only copper condensing coil unit for split type AC 1.5 / 2.0 ton capacities complete all as specified and directed by Engr-in-charge.
S&F copper cooling coil unit for split type AC of any type all as directed by Engr-in-charge including taking out old unserviceable cooling coil unit.
S&F capacitor for blower motor suitable for split type AC 1.5 ton capacity including taking out old unserviceable capacitor complete all as specified and directed by Engr-in-charge.
S&F for copper pipe 5/8" / 1/2" / 3/8" / 1/4" dia (as per existing one) for connection indoor and out door unit complete all as specified and directed by Engr-in-charge..
S&F for PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS,complete all as specified and directed by Engr-in-charge. (Make : KDK/Nicco/Finolex/Havells)
S&F PVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete all as specified and directed by Engr-in-charge. (Make : Nicco/Finolex/Havells)
S&F swinging motor of split type AC 1.5/2 TR with louvers as pr existing out old unserviceable swinging motor with louvers complete all as specified and directed by Engr-in-charge.
S&F in repair fan blade for blower motor suitable for split AC 1.5 ton / 2.0 ton capacity including taking out old unserviceable blade complete all as specified and directed by Engr-in-charge.
S&F fan blade for outdoor unit of split type AC of any capacity including taking down old one complete all as specified and directed by Engr-in-charge.
S&F for LCD / LED display unit for split type AC 1.5 / 2.0 ton capacity including taking out old unserviceable unit complete all as specified and directed by Engr-in-charge.
S&F for replacement of PVC air filter for AC split type 1.5 / 2.0 ton capacity complete all as specified and directed by Engr-in-charge.
S&F for PCB for control unit for split type AC 1.5 / 2.0 ton capacity as per existing and same make complete all as specified and directed by Engr-in-charge.
Supply only remote control unit for split type AC 1.5 / 2.0 ton capacity as per existing and same make complete all as specified and directed by Engr-in-charge.
ANIL KUMAR GUPTA
M/S East India Traders
Rounaq Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .