| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC KHALARI RANCHI RANCHI JHARKHAND 829205 INDIA | RANCHI | JHARKHAND | 829205 | ₹2.4 L Quoted ₹2.0 L | L1 | Accepted-AOC The L1 bidder is techno-commercially qualified. The quoted rate has been accepted by the Competent Authority, NK Area |
| 2 | L2₹2.1 L+₹6,658 (3.26%)Rejected-Finance STATION ROAD KHALARI PO PS KHALARI DIST RANCHI 829205 | KHALARI | RANCHI | JHARKHAND | 829205 | ₹2.1 L+₹6,658 (3.26%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically disqualified. |
| Sl No | Description | Qty | Unit | M/s DILIP ELECTRICAL WORKS L2 | M/S AVINASH ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Cost of 72 Sq. mm Voltmeter 0-5 KV/110V | 1 | Nos | 1,380 ₹1,380 | 1,350 ₹1,350 Lowest |
| 2.00 | Cost of 72 Sq. mm Ammeter supressed scale. | 1 | Nos | 1,380 ₹1,380 | 1,350 ₹1,350 Lowest |
| 3.00 | Cost of Isolator 400 Amp. 3.3 kV | 1 | Nos | 48,500 ₹48,500 | 48,235 ₹48,235 Lowest |
| 4.00 | Cost of Push button with element for start, stop, test and reset | 2 | Nos | 510 ₹1,020 | 500 ₹1,000 Lowest |
| 5.00 | Cost of DMC Moulded support insulator for isolator | 6 | Nos | 1,060 ₹6,360 | 1,054 ₹6,324 Lowest |
| 6.00 | Cost of Resin cast PT 750 VA, 3.3 kV/110V Single phase | 1 | Nos | 32,500 ₹32,500 | 32,410 ₹32,410 Lowest |
| 7.00 | Cost of copper busbar 400 Amps set of three | 1 | Set | 15,000 ₹15,000 | 12,500 ₹12,500 Lowest |
| 8.00 | Cost of vacuum contactor rectifier bridge unit | 1 | Nos | 6,000 ₹6,000 | 5,756 ₹5,756 Lowest |
| 9.00 | Cost of vaccum contactor closing coil 110 Volts DC | 1 | Nos | 8,800 ₹8,800 | 8,500 ₹8,500 Lowest |
| 10.00 | Cost of isolator fixed contact Set | 1 | Set | 15,500 ₹15,500 | 15,000 ₹15,000 Lowest |
Tender Value
₹2.3 L
EMD Value
₹2,900
Closing Date
20 Apr 2026, 5:00 pmClosed
SO EnM NK
GM OFFICE, NK AREA
Repairing and reconditioning of one (01) no. of starter FLP DOL Starter 3.3kV, 225 kW, CTR 50/5, Make Sait Mineline, Sl. No. FHD1368 installed at 61 No. Pump under Churi UGP, NK Area
2026_CCL_358115_1
GM (NK)/EnM/e-NIT/2026-27/ 06
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Churi Colliery, NK Area
As per NIT
2 documents required · 2 mandatory
₹2,900
29 May 2026
8 Apr 2026
21 Apr 2026
9 Apr 2026
20 Apr 2026
9 Apr 2026
9 Apr 2026 - 15 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Cost of 72 Sq. mm Voltmeter 0-5 KV/110V | - | Nos | - | - |
| - | Cost of 72 Sq. mm Ammeter supressed scale. | - | Nos | - | - |
| - | Cost of Isolator 400 Amp. 3.3 kV | - | Nos | - | - |
| - | Cost of Push button with element for start, stop, test and reset | - | Nos | - | - |
| 5 | Cost of DMC Moulded support insulator for isolator | - | Nos | - | - |
| - | Cost of Resin cast PT 750 VA, 3.3 kV/110V Single phase | - | Nos | - | - |
| - | Cost of copper busbar 400 Amps set of three | - | Set | - | - |
| - | Cost of vacuum contactor rectifier bridge unit | - | Nos | - | - |
| - | Cost of vaccum contactor closing coil 110 Volts DC | - | Nos | - | - |
| - | Cost of isolator fixed contact Set | - | Set | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.54 MB
BOQ_371000.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .