Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.1 LAccepted-AOC | L1 | Accepted-AOC Work award | |
| 2 | Rejected-Technical AT NANDINI ROAD BHILAI CHHATTISHGARH 490001 | BHILAI | CHHATTISHGARH | CHHATTISHGARH | 490001 | - | Rejected-Technical Shortfall document not submitted | |
| 3 | Rejected-Technical | - | Rejected-Technical Shortfall document not submitted | |
| 4 | Rejected-Technical | - | Rejected-Technical Document not submitted as per NIT |
Tender Value
₹1.2 Cr
EMD Value
₹1.5 L
Closing Date
14 Sept 2022, 4:00 pmClosed
Staff Officer Civil WNA
AGM Office Bhallar Township Wani North Area
Providing and laying APP and grading roof for water proofing treatment works to residential quarter, Transit Hostel and VIP Guest House at Bhallar Township of Wani North Area
2022_WCL_254200_1
wn4650-civ-e023-2022-23 dt.20.08.2022
Open Tender
Civil Works - Others
Item Rate
150 days
Bhallar Township
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.5 L
12 Jan 2023
23 Aug 2022
15 Sept 2022
24 Aug 2022
14 Sept 2022
24 Aug 2022
24 Aug 2022 - 10 Sept 2022
Amount
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and mixing water proofing material in cement concrete work in proportion recommended by the manufacturers.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
Removal of old tarfelt or APP and disposal within a lead of 50 mtr. as per direction of Engineer-In-Charge.
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .