Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC BARKHOPA HOUSE NO 0 CITY TOWN TAMULPUR P O BARKHOPA P S TAMULPUR DISTRICT BAKSA PIN 701367 | 701367 | ₹1.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹2,025 (0.01%)Rejected-AOC VILLAGE KATRIBARI P O HOMABIL P S DOTMA DIST KOKRAJHAR BTC ASSAM | DHUBRI | ASSAM | 783331 | ₹1.5 Cr+₹2,025 (0.01%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical ASSAM AS | KARIMGANJ | ASSAM | 788803 | - | - | Rejected-Technical reject |
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
13 Mar 2023, 1:30 pmClosed
the Addl. Chief Engineer, PWD
O/o the Addl. Chief Engineer, PWD
Construction of F.R.U. (RCC Ground Floor only) at Goreswar 30 Bedded Hospital in Baksa District.Pkg No.104_4
2023_BTC_29570_1
No. ACE- 106/PWD/IFB/2021-22/154
Open Tender
Civil Works - Building
Item Rate
365 days
baksa
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
₹2.9 L
Yes
O/o the Addl. Chief Engineer, PWD
29 Mar 2023
27 Feb 2023
13 Mar 2023
27 Feb 2023
13 Mar 2023
27 Feb 2023
27 Feb 2023 - 9 Mar 2023
9 Mar 2023
Amount
(A) Cost of Civil Work: 2.8. Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size.
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.1 Mild steel and Medium Tensile steel bars.
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.3 Suspended floors, roofs, landings, balconies and access platform
5.9.7 Stairs, (excluding landings) except spiral-staircases
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size.
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood.
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 Second class teak wood 9.5.1.1 35 mm thick shutters
9.7 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 9.7.1 Second class teak wood
21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 21.8.1 Upto 5mm depth and 5 mm width
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
9.117 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer?in-charge. 9.117.1 Extruded section profile size 48x40 mm
9.118 Providing and fixing to existing door frames. 9.118.1 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
13.4 12 mm cement plaster : 13.4.2 1:6 (1 cement : 6 coarse sand)
13.5 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.2 1:6 (1 cement : 6 coarse sand)
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding
2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.3 Treatment of soil under existing floors using chemical emul?sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.4 Size of Tile 1000x1000 mm
11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
13.9 Cement plaster (1:3) finished with a floating coat of neat cement. 13.9.1 12 mm Cement Plaster
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.41 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
13.44 Finishing walls with water proofing cement paint of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.50 Applying priming coat: 13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 9.96.2 250x16 mm
9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.97.2 250x10 mm
9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.100.1 125 mm
(B) SANITARY INSTALLATION: SEPTIC TANK 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.3 Suspended floors, roofs, landings, balconies and access platform
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
6.12 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : 6.12.2 cement mortar 1:4 (1 cement : 4 coarse sand)
13.4 12 mm cement plaster : 13.4.2 1:6 (1 cement : 6 coarse sand)
13.9 Cement plaster (1:3) finished with a floating coat of neat cement. 13.9.1 12 mm Cement Plaster
19.18 Supplying and fixing C.I. cover without frame for manholes : 19.18.2 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid
17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
17.11 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 17.11.2 Size 600x450x200 mm
17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
17.35 Providing and fixing soil, waste and vent pipes : 17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729
17.35 Providing and fixing soil, waste and vent pipes : 17.35.1 100 mm dia 17.35.2.1 Sand cast iron S&S pipe as per IS: 1729
17.36 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 17.36.2 100 mm dia pipe
17.36 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 17.36.1 75 mm dia pipe
18.58 Providing and fixing PTMT grating of approved quality and colour. 18.58.2 Rectangular type with openable circular lid 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating
19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
(C) WATER SUPPLY WORKS 18.42 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested : 18.42.3 Beyond 12 m and up to 18 m depth
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.7 62.50 mm nominal dia Pipes
18.43 Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality
23.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 18.7.5 40 mm nominal dia Pipes
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 18.8.3 25 mm nominal dia Pipes
18.8.1 15 mm nominal dia Pipes
18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 15 mm nominal bore
18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore
18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 15 mm nominal bore
18.56 Providing and fixing PTMT pillar cock of approved quality and colour. 18.56.2 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms
18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 18.22.2 150 mm diameter
17.22B Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.3 25 mm nominal bore
(D) EARTH FILLING 2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
(E) Internal Electrification: WIRING 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point With 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRIS PVC insulated copper conductor single core cable etc. as required. 1.10.1 Group B
1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 1.23.4.3 pin 5/6 A socket outlet
1.23.5.6 pin 15/16 A socket outlet
1.14 wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.12 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
1.14.22 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
1.14.32 x 4 sq. mm + 1 x 4 sq. mm earth wire
1.14.42 x 6 sq. mm + 1 x 6 sq. mm earth wire
1.14.84 x 4 sq. mm + 2 x 4 sq. mm earth wire
1.14.94 x 6 sq. mm + 2 x 6 sq. mm earth wire
1.14.10 4 x 10 sq. mm + 2 x 6 sq. mm earth wire
1.14.11 4 x 16 sq. mm + 2 x 6 sq. mm earth wire
Providing and fixing following capacity TP & N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 2.1.4 125A TP & N
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/1solator) 2.3.2 8 way , Double door
2.3.3 12 way , Double door
2.5 Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBS and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 25.14 way (4+ 12), Double door
2.10 Supplying and faxing 5 A to 32 A rating 240/415 V. 10 KA C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required 2.10 1 Single pole
2.14 Supplying and foxing following rating, double pole, (single phase and neutral), 240 V residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections. testing and commissioning etc. as required 2.14.2 40 A
2.13 Supplying and fixing following rating, four pole, 415 V. solator in the existing MCB DB complete with connections, testing and commissioning etc as required 2.13.2 63 A
DSR (E&M) 2019 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Directed Current (BLDC) Motor, class 2019 insulation resistance more than 2 mega chm, suitable for 230 V 50 Hz. single phase AC supply, earthing etc.complete as required
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
1.38 Supplying and fixing call bell buzzer suitable for single phase, 230 V. complete as required
1.41 Installation, testing and commissioning of pre-wired. fluorescent fitting/compact fluorescent fitting of all types,complete with all accessories and tubellamp etc directly on ceiling/ wall, including connections with 1.5 sq mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required.
Earthing with GI earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/ coke and salt as required.
5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I Wire in 15 mm dia G1 pipe 512 from earth electrode including connection with GI thimble excavation and re-filling as required.
5.5 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoall coke and salt) as required.
5.8 Supplying and Laying 25 mm X 5mm copper strip at 0.50 metre below ground as strp earth electrode, including connection terminating with nut, bot, spring, washer etc as required (Jointing shall be done by overlapping and with 2 sets of brass nut bott & spring washer spaced at 50mm).
7.1 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning protective covering and refilling the trench etc as required 7.1.1 Upto 35 sq mm
Supplying fitting & fxing of LED tube light aluminum Extruded smart Bright Batten light fitting (4 ft) Model No BNO21C LED225 PSU CW GR (Philips make) as required and as directed by the department
Supplying Fitting & fixing of LED Bulb (W/W/12W) non dimmable in the existing batten Angle holder as required and as directed by the department (Philips or eqvt. Make)
Supplying installation testing and commissioning of Green perform lighet luminanes of model no 5116877- 12701385672 (philps make as required and as directed by the Deptt Basic price for Green perform Sleek LED down lighet luminaries of model NO5116877- 12701385672 (Philips make) including GST (1200 lumen)
Supplying, fitting & fixing of exhaust fan 230mm sweep Model No Ventil Ar- DS (Havells make) as required and as directed by the department
Supplying including installation, testing and commissioning of Hi-Wall Non ductable type of 1.50 Ton capacity having proper cooling capacity single phase 3 STAR MODEL Spilt type Inverter Air CONDITIONER Machine complete with corded Remote, copper pope connection between indoor & outdoor Unit, electrical connection etc (Voltas Make) Model no Voltas SAC 183V CZR 1.5 Ton Capacity
2 Ton Capacity
Supplying with fitting and fixing of 4 KVA Voltage stabilizer including making necessary connection as approved specified and directed by the deptt (Vee- Dee make) Model no VD 40908
Supplying with fitting and faxing of single Phase Modular Motor Starter switch including making necessary Each connection as per direction of
Supplying installation testing and commissioning of pressure dia cast powder coated aluminium alloy housing forested PC diffuser IP65/1P66 protection of street light including connetion with 25 sq. mm 3 core PVC insulated Each rounded copper conductor Model No- (ENDURA CITYLINER NEO 70W) (Havells make) as required and as directed by the deptt.
Supplying, fitting & fixing of LED Decorative post TOP Lantern with IP65 protection (Bajaj make) fitted on existing Gl pipe with all accessories as required and as directed by the department
Supplying installation testing and Commissioning of pressure dia cast powder coated aluminium alloy housing forested PC Diffuser IP65 IP66 protection of flood light including connection with 2.5 sq mm 3 core PVC insulated rounded copper condcutor Model No (5116877- 62992085418) (Havels make) as required and as directed by the Deptt.
Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169Km/hr. The top loading e. area and weight of fixtures are to be considered to calculate maximum deflection of the poless and the same shall meet the requirement of BS: 5649 Part VI 1982. The poles shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of pole shaft shall be done by submerged welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be fillet welded to the pole shalt at two locations ie from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency.
Supplying installation and commissioning of Astronomical Timer for Street light Control panel board made out with 16 mm CRCA sheet steel, 3 phase, suitable for floor mounted user front facia, Powder coated for long lasting finish, cibical type,suitable cable entry provision and including of all necessary electrical protections including Aluminium Bus bar etc. complete neatly internal wiring done as specified and directed by the deptt. comprising of the following electrical items. 1.40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer-1,2 Timer-1 no, 3 Contractor-1no. 4 40 Amp DP MCB-3nos
Supplyng including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor type double door, floor mounting compartmentalize panel board of size 800mm x 1200mm x 400mm made of 16 SWG1 66 mthick CR sheet and 35mm x 35mm x 5mm size angle having 4 no legs at the bottom and CR sheet roffing on the top The panel board is to be erected in 1:3:6 PCC foundation including excavation of trench and brick soiling etc. complete neatly Wiring done with provision for 1) 1 no 250 A 4pole 415 V MCCB 2) 2 nos. 250 A spreader terminal, 3) NO 160 a 4p MCCB 4) 2 nos 160 A spreader terminal 5) 3nos 32 A 4P MCB etc
Supplying of following size PVC/XLPE insulated and PVC Sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated. cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2 x 10 sq mm 3x 10 sq mm, 4x6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed. 650/1100 V grade as per IS 7908 (Part 1) 1988 armoured UG cable UG cable laid in ground/partially in air (As required for termination up as specified and directed by the deptt (RR Kabell Havells/Polycab make or equivalent) 4.00 sq mm 2 core armoured cable (Havells or equivalent make)
600 Sq mm 2 core armoured cable (Havells or equivalent make)
10.00 Sq mm 2 core armoured cable (Havells or equivalent make)
16.00 Sq mm 2 core armoured cable (Havells or equivalent make)
50.00 Sq mm 2 core armoured cable (Havells or equivalent make)
Supplying including installation, connection as approved by the Deptt. Testing and commissioning of OPENWELL SUBMERSIBLE PUMP SET complete with submersible cable etc as directed and specified by the deptt 1 HP Single Phase open well Submersible monoblock water cooled pump set (Crompton Greaves/Aquatic/CRIV Guard make) 220 v 50 hz, 2900 rpm with control panel.
Load Security paid to the APDCL authority
3 (Three) phase metre Security paid to the APDCL authority
RUSTAM BASUMATARY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .