| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹48.4 L+₹2.3 L (4.91%)Rejected-AOC 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L2 | Rejected-AOC OK | |
| 3 | L3₹49.5 L+₹3.4 L (7.37%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹54.3 L+₹8.2 L (17.7%)Rejected-AOC | L4 | Rejected-AOC OK |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
6 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI MAHAVIR SINGH,IDSE
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD
ADD/ ALTN WORKS BLDG NO. E-05 OF 654 EME BN,SQAE(S),BLDG NO. 58,59 AT DGQA AND PROVN OF TOILET,BATHROOM IN 60 COY ASC (SUP), SOME REVENUE AND MINOR WORKS OF AGE B/R (S) NO I, II AND AGE E/M (S) UNDER GE (SOUTH) SECUNDERABAD
2020_MES_403320_2
GE (S)/SEC/TOKEN - 52 OF 2020 - 21
Open Tender
Civil Works
Item Rate
180 days
Secunderabad
For Enlisted contractors class D and above category a (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for eligible class along with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹95,000
Yes
26 Apr 2021
19 Jan 2021
9 Feb 2021
19 Jan 2021
6 Feb 2021
21 Jan 2021
19 Jan 2021 - 20 Jan 2021
60 days
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil all as specified and directed.
Excavation over areas n.exc. 1.5 mtr and getting out in hard/dense soil all as specified and directed..
Excavation over areas exc. 1.5mtr deep but n.exc. 3.00 deep and getting out in hard/dense soil all as specified and directed..
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc and getting out in Hard/Dense soil all as specified and directed..
Returning filling in incuding spreading levelling and well ramming in soft/loose soil in layers not exceefing 25 cm thick complete all as specified
Removing excavated materials in exc 50 Mtrs an deposited where at a level n. exc 50 mtr where directed n exc 1.50m above the starting point all as specified and directed.
Removing the excavated soil to a distance exc 250.0 m and n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed..
M & L Hard core of gauge not exceeding 63mm of broken briicks, deposited, spread and levelled in layer n.exc 15cm thick, watered and well rammed to a true surface all specified
M & L Hard core of guage n.exc 63mm of broken stones, deposited, spread and levelled in layer n.exc 15cm thick water and rammed to a true surface. complete all as specified and as directed
Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not execeeding 50 M and making good surface. complete all as specified and as directed
Excavation in post holes or (similar holes) each n exc 0.50 Cum in soft/loose soil, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
M&L PCC 1:4:8 Type D2 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete all as specified and directed..
M&L Reinforced cement concrete B1 1:2:4 (20 mm graded stone aggregates) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L reinforced cement concrete B1 1:2:4 (20 mm graded stone aggregates) Columns, pillars, piers,posts and struts etc complete all as spd and as directed.
M&L reinforced cement concrete B1 1:2:4 (20 mm graded stone aggregates) as in beams, cantileavers, bressummers, lintels over 1.5 clear span etc complete all as specified and as directed.
M&L reinforced cement concrete B1 1:2:4 (20 mm graded stone aggregates) Slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and as directed..
M&L reinforced cement concrete B1 1:2:4 (20 mm graded aggregates)in Chajjas etc complete all as spd and as directed.
M&L for PCC Block wall type C-1 (1:3:6) (using 20mm graded broken stone agg )exc 10 cm thick straight or curved on plan exceeding 6mm mean radius built in Cm 1:6 complete all as specified and directed.
M& L cement concrete type B-1 (1:2:4) (using 20mm graded broken stone agg) as coping,benching, cills, lintels, band, filling around hold fast, fitting in chowkats etc. Including necessary form work complete all as specified and as directed
Supply only integral water proofing compound all as specified and directed.
M&L Providing pre cast cement concrete block in ( 1:2:4) Type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops rounded or chamfered on edtes complete all as specified..
M&L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation filling and post holes complete all as specified and as directed.
M&L Cement concrete (1:2:4) Type B2 ( using 40mm graded stone aggregate ) (including caps and bases) or foundations, filling and mass concrete for posts complete all as specified and as directed.
M&L brick work with subclass B bricks ,straight or curved on plan exc 6m mean redius built in cm 1:6 complete all as specified and as directed.
M & L brick work with sub class B bricks straight or curved on plane to any radius in half brick thick wall built in CM 1:4 all as specified and as directed..
M/L brick work with Fly ash bricks built in CM 1:4 straight or curved exceeding 6m mean radius all as specified and as directed..
M& L damp proofing course to horizontal/vertical surface incl necessary form work 40mm thick PCC type B-0 1:2:4 mixed with WPC @ 3 % by weight of cement all as specified and as directed. Note :_ WPC will be measured and paid seperately
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and as directed
Cutting holes into or through brick walls n exc 150 Sq cm built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required all as specified and as directed..
M&L for cutting holes in brick walls built in cement mortar exc. Half brick but not exc. One brick and making good dismantled portion in CM (1:3) or cement concrete 1:2:4 Type B1 as requerd.all as specified and as directed.
Form work to side of concrete foundation, flooring base, base of columns, side and soffits of plinth beam and simillar work for flat and rough finished all as specified and directed.
M & L for Form work to sides and soffits of floor or roof beams, lintels, shelves including supports, overhungs etc. for flat rough finished surfaces completed all as specified and directed.
M&L form work to sides of squre or rectangular column, pillars etc. for rough finished surfaces complete all as specified and as directed
Formwork to rough finished surfaces of flat concrete,soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping),etc complete all as specified and as directed.
M&L form work to edges of concrete n exc 20cm wide rough finished surfaces, flat, treads, break in floors, window cills, concrete railing etc. all as specified and as directed.
M&L Form work to chulla hoods, chajjas and similar item of rough finished surface of concrete incl edgs all as specified and directed.
Taking down Chowkats or frames exc 1.5 Sqm but not exceeding 4 Sq. M each (Without taking off shutters from the frames)complete all as specified and as directed.
Taking down shutters of any description exc. 1.00 Sq.m and n.exc. 2.00 Sq.m each all as specified and directed...
S & F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints.complete all as specified and as directed.
S & F 35 mm thick second class hard wood factory made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars) chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in SSR Pt I Section 8, clause 8.24 (a)complete all as specified and as directed.
S & F 35mm thick 2nd class hard wood plain framed pannelled shutter (Two panels) rail and style of 2nd class hard wood thick, panel of 12mm venered particle board kiln seasoned and chemically pressure treated the size of rails and style ap per IS 1003 (Part-1) complete all as specified and as directed
S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides.complete all as specified and as directed.
S&F solid PVC door frame f size 50 x 47 mm made out of 5mm thick palin colour PVC sheet with MS square tube suppling and fixing in opening as per specified and as directed
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded oplain colour PVC 'C' channel having a PVC sheet strip of 20mm thick width stuck inside with solvent cement for style and palin colour PVC sheets for tops rail, lock rail and bottom rail,Panelling of plain color PVC sheets to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and joined together with the solvent cement, suppling and fixing in the frame at site . complete all as specified and as directed
S&F 300 mm size Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed.
S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges.complete all as specified and as directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised.complete all as specified and as directed.
S&F 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and as directed.
S&F in galvanised MS wire cloth 0.5mm nominal dia of wire and average width of aporture 1.18 and fixed with tinned tacks or galvanised wirestapples etc complete all as directed
S&F Tublar towel rail brass chromium plated, 20mm dia, D type 60cm, between the flangers complete all as specified and as directed.
S&F in repair door closure extruded aluminium body hydraulically regulated disignatin No 3 universal type suitablefor door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified and directed.
S & F brass Mortice lock 4 leavers vertical type size 100mm all as specified and directed..
S & F 150mm long floor door stopper of aluminium alloy boly and tongue anodised with hard steel spring fixed in floor all as specified and directed..
S&F of CP Curtain rods incl necessary D type brackets and fixtures complete all as specified and directed..
M&L for fixing Gl frame work 600 x 600mm snap grid (Bottom pre coated) for Exposed metal frame ceiling comprising of Gl perimeter wall anglel 25 x 25 x 0.7 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre and intermediate GI 3600mm long main "T" 25mm web x 35mm flange x 0.7 mm thick suspended from soffit at 1200 mm centre to centre and inserting /fixing to main 1200 long cross "T" 25mm web x 35mm flange x 0.7 mm thick at 600 c/c to form 1200 x 600 grid and inserting /fixing 600 long cross "T" 25mm web x 35mm flange x 0.7 mm thick to form 600 x 600 grid with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with clips of 10.5 mm fixed to the main "T" with connecting clips across the intermediate "T" at 600 mm centre to centre. complete all as specified and as directed.
S & F MS TMT steel bars10mm dia and over cut to length bent to shape reqd incl cranking, bending and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified
S & F MS TMT steel bars 06 to - 08mm dia and over cut to length bent to shape reqd incl cranking, bending and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S & F MS TMT steel bars 5mm dia and over up to and including 10mm dia as in stirrups, spacers cut to length bent shape reqd incl cranking, bending and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified
S&F steel window with side hung shutters incl projecting type hingers with steel handles and peg stays with glazing bars, devotailed or welded completed all as specified and directed
S&F steel window with side hung shutters incl projecting type hinges with steel peg stay complete with out glazing bars dovetailed or welded complete all as specified and as directed.
S&F steel windows or ventilators, fixed type, with glazing bars all as specified and directed
M&L for framed work such as grills, gratings etc with ends of bars, framed guard bars, ladders etc and similar works conforming to FE-290, Gde E-165 all as specified and directed..
S & F Aluminium anodized frame work for door / windows / ventilators with one or more rebates including joining heat for fixing etc complete all as specified and as directed.
S & F anodized door shutters, aliminium section weighting 0.55 Kg/M including necessary joinging cleats, galzing clips, ruber neoprene pakcing handles 2 Nos in each door, hinges anodised aliminium snap beading screws etc, complete all as specified
S&F anodied aluminium window and ventilator shutter ,side hung type without sash bars aluminium sections weighing 0.55 kg/m including necessary joining cleats ,glazing clips rubber packing anodised aluminium snap beading ,screws,anodised aluminium fitting such as peg stays 150 mm long (1 no),hinges typeB-21 100mm long (2 nos) suitable handle (1no) complete all as specified.
M & L for Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde- E- 250) complete all as specified and directed.
M&L MS Steel Rolled sections MS pipe in column /Angle as in ; purlins where connected to common rafters and running rails other connecting plates of Fe 410 -W (Gde- E- 250) complete all as specified and directed.
S&F for posts and struts in fencing / water tank stageing and similar work including embedding in concrete and screwing etc. including securing bolts;cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0.complete all as specified and as directed.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doo0rs etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M&L for welded mesh not exc 4.0 Kg/Sqm fixed with steel member complete all as specified and directed by Egnineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed.
S & F Pre-painted galvalume aluminum zinc coating GI vased Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed.
M & L cleaning and preparation of concrete surfaces and applying priming coat using with bituminous primer @ 0.30Kg per Sqm followed by evenly a tack coat @ 1.20 Kg per Sqm using with 85/25 grade industial bitumen, over it laid APP modified plymer water proofing membrane with non-woven polyster reinforced of weight not less than 3 kg per Sqm unrolled and bonded to substrate with side and end laps 100mm as per manufacturesr's instructions and finally finished the top of polymeric water proofing membrane with a coat of bituminous base aluminium paint @ 0.200 kg per Sqm as per manufacturer's instructions complete all as specified and as directed.
M&L for priming plastered roof surfaces with bituminous primer @ 0.3 Kg/Sqm as per IS 3384 and providing water proffing treatment by applying mineral finish 3.5 Kgs/Sqm Actatic Polyprofhylene (Advanced APP torch on membrane mineral finish) having polyster film reinforcement stablised with fibre glass and finished on top with grey mineral slaltes torch on system of thickness 3.00 mm by torch bonding complete, all as directed and as specified.
M&L for 8 mm calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) as in ceiling complete all as specified and as directed.
S & F prelaminated particle board 9mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixed with screws all as specified and directed...
M&L for 75 mm thick PCC 1:4:8, type D-2 ( by using 40 mm graded stone aggregate) as in sub base floor/ pavings complete all as specified and as directed. .
M&L for 20-25mm thick machine cut kota stone slab flooring/ skirting/ dado over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Machine cut polished sahabad stone slab flooring 20-25mm thick as in flooring, etc and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc . complete all as specified and directed by Engr-In-Charge.
M&L machine cut polished sahabad stone slab 20 -25 mm thick in riser of steps ,skirting ,dado and piller laid over cement screed and jointed with complete all as specified and as directed.
M&L Chequered cement concrete tiles 25cm x 25cm x 25 mm thick set, jointed with white cement & pigment and pointed in colour / white cement to match the shade of tile over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for chequered cement concrete tiles with grey cement and pigments of size 30cmx30cmx20-25mm thick set, jointed and pointed in neat cement slurry over and including 15mm thick CM 1:6 screed bed in flooring complete all as specified and as directed.
M&L chequered cement concrete tiles 20cm x 20cm x25mm , thick with grey cement and no pigment fixed on screed surface complete all as specified.
M&L Machine pressed precast conctete interlocking paver block With Grey cement and pigment of any shape, size and colour confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade all as specified and directed..
M & L 75mm th PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate)as sin sub base, floors, paving plinth proctection finished even and fair complete all as specified
M&L Cement concrete 100 mm thick type D-2, 1:4:8 (40mm graded stone aggregate) as in floors/ plinth protedtion complete all as specified.
M&L 75 mm thick Cement Concrete (1:2:4) type B1 (20mm Graded stone Aggregate) as in floor finish complete all as specified and directed by Egnineer-in-Charge.
M&L non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exc 0.06sqm but n.exc 0.11 Sqm, io floors etc. set and joined in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors surface set and jointed in neat cement slurry and pointed with white or colour cement to match over and including 15mm screed bed in cement mortar 1:6 complete all as specified and as directed.
S & f glazed ceramic tiles of size 200 x 300 x 7mm hick coloured tiles over 10mm thick in C M (1:4) for packing coat for receivimg tiles all as specified and as directed..
Roughening surfaces of new/old concrete floor by picking sweeping cleaning & washingg down with water to remove dust etc applying one coat of neat cement slurry @ 3.00 kg/Sqm complete as directed by Engr-in-charge.
M&L for PCC 25mm thick 1:2:4 type B1 using 20mm graded stone aggregate as in padding (level course) on roof surface etc complete all as specified and as directed.
Taking down cement plaster any description including terrazo dados and the like on brick or stone walls, Ceilings etc including raking out joints,hacking for key, scrubbing down with water etc all as specified and directed...
M&L for 20 mm thick screed bed or bedding layer in CM 1:6 for laying floor finishescomplete all as specified and as directed.
M&L for 10 mm thick rendering on vertical surfaces of wall such as skirting/dado in CM 1:3 for laying tiles complete all as specified and as directed.
M&L 15mm thick screed bed or bedding layer or mortar for laying in floor finish as in CM 1:6 complete all as specified.
M&L for Rendering 15mm thick in CM 1:6 on fair faces of brick/concrete surface including finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick on brick/concrete surface in CM 1:6 to wall finished even and smooth without using extra cement all as specified and directed..
M & L for 15mm thick rendering in CM 1:4 mixed with water proofing compond as per manufacturer's instructions on Fair faces of bricks wall or concrete surfaces finished even and smooth complete all as specified (WPC shall be measured and paid separetaly)
M&L for rendering 5mm thick in ceiling in cement mortar 1:3m finished even and smooth all as specified and directed.
M&L for rendering 10 mm thick in CM 1:3 mixed with integral water proofing compound as per manufacture's instructions as in roof and chajjas, finished the surface fair and even with out using extra cement.(Note : Supply of water proofing compound will be measured and paid separately .)
M & L preparation of new ceiling surface and applying two coats of Distemper oil emulsion,.complete all as specified and as directed.
M&L for prepration of new plaster surface of walls and applying two coat of oil bound distempers over one coat of primer and two coat of wall care putty complete all as directed by Engr-in-charge.
M&L for Preparations of newly plasters surfaces of Ceiling and applying three coats of white wash complete all as specified
M&L preparation of old ceiling surface and apply two coats of White wash over a coat of primer all as specifiedd and directed.
M&L for Preparations of newly plasters surfaces of wall and applying three coats of white wash all as specified and directed...
M&L for Preparations of newly plasters surface of wall and applying two coats of ceement base paint complete all as specified.complete all as specified and as directed.
M&L for preparing new plaster surfaces of walls and apply with two coats of cement base paint over a coat of alkali resistant primer complete all as spd and directed.
M&L preparation of newly plastered surface on wall and apply r two coats of oil bound distemper over a coat of primer .complete all as specified and as directed.
M&L preparation of old plastered surface on wall and apply two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M&L sheet glass ordinary quality 3mm thick and glazing with oil putty in squares n. exc. 0.5 Sqm each pane complete all as specified
M&L for Preparation of New wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coats of synthetic enamel paint.complete all as specified and as directed.
S&F 15mm bore GI tubing medium grade with all fitting and fixed to walls or laid on floor complete all as specified and as directed.
S & F 15mm bore tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed.
S&F 20mm bore GI tubing medium grade with all fitting and fixed to walls/ ceiling or laid on floor all as specified and as directed..
S&F 25mm bore GI tubing medium grade with all fitting and fixed to walls or laid on floor/ trenches all as specified and as directed..
S& F 15mm bore stop cock/angle valves cast copper alloy CP screwed down high pressure with crunch or butter fly handle, screwed both ends for iron pipe or for unions 15mm bore complete all as specified and as directed.
S& F 15mm bore stop cock/angle CP concealed type valves CP screwed down high pressure with crunch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F 15mm dia bib tap cast copper alloy with cructh or butterfly handle screwed down for iron pipe or for brass ferrule complete all as specified and as directed.
S&F 15mm dia Two way bib tap cast copper alloy with cructh or butterfly handle screwed down for iron pipe or for brass ferrule all as specified and as directed..
S&F Fancy type 15 mm bore bib taps,Bib tap cast copper alloy with crutch or butterfly handle scerwed down for Iron pipe and fixed complete all as specified and as directed.
S & F 15mm bore bib taps, brass chromium plated, screwed down, screwed for iron pipe or for brass ferrule including flench as in repair complete all as specified and directed.
S & F C P Health faucet 1.0 m long complete all as specified and as directed.
S &F brass CP shower rose 125mm size complete all as specified and as directed.
S&F15mm bore pillars taps, cast copper alloy with capstan heads CP fancy type screwed down high pressure, with long screwleed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed
S&F PVC low level flushing cistem 10 ltrs capacity white, symphonic action type with inlet, ball valve, float and handle incl brackets fixed complete all as specified and directed..
S&F wash hand basin 550 x 400 (coloured) fancy type incl all connected fitting complete all as specified and directed..
S&F vitreous china bowl urinal flat size 465 x 355 x 265 mm white with grating and union for discharge pipe incl PVC waste pipe, urinal spreader complete all as specified and directed..
S&F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) etc complete all as spd and directed.
S&F 75mm dia PVC (SWR) floor trap plain with grating incl jointing with solvent cenment all as specified and directed..
S&F 110mm dia PVC (SWR) WC connector with lip ring all as specified and directed..
S&F 110mm dia PVC (SWR) WC connector bend type all as specified and as directed..
S&F PVC (SWR) bends any radius 75mm bore provided with access door all as specified and as directed..
S&F PVC (SWR) bends any radius 110mm bore provided with access door all as specified and directed..
S & F PVC (SWR) junction single T equal or un-equal 75mm bore all as specified and as directed..
S & F PVC (SWR) junction single T equal or un-equal 100mm bore all as specified and as directed..
S&F 110mm bore PVC (SWR) vent cowl all as specified and as directed..
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, 75mm bore all as specified and as directed..
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, 100mm bore all as specified and as directed..
S&F 110mm bore PVC (SWR) reducer all as specified and as directed..
S&F 110mm bore SWR bends aby radius all as specified and as directed..
S&F 75mm bore PVC SWR bends any radius all as specified and as directed..
S&F PVC connection 15mm size with PTMT nuts of length 600mm all as specified and directed..
S&F waste pipe PVC 32/40mm al as specified and as directed
Materials and labour for 150mm dia salt glazed stone ware drain pipes laid over cement concrete type D 2 1:4:8 (using 40mm stone agg) for bed to 150mm dia drain pipes incl packing under and hunching against sides of pipes complete including necessary earth work as required complete all as specified and as directed
S&F100mm dia sand cast iron soil waste and vent pipes in any length with or without ears, with cement joints fixed to walls complete ass as specified.
S&F Cast iron vent cwl of 100mm dia all as specified and as directed..
Cutting into existing manholes for connecting new drain making good to pipe and rendering cutting out existing benching for and forming branch channel C1/2 round or 3/4 section) in cement concrete 1:2:4 type B 1 smooth finished and reforming benching all as specified and directed..
S&F in rotational moulded polyethylene water storage tanks1000 ltrs(cylindlerical vertical with closed top) hoisted and fixed in position all as specified in SSR part I . all as specified and as directed.
S&F 20 mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe as in repairs complete all as specified and as directed.
S&F 25 mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe as in repairs complete all as specified and as directed.
S&F 20mm bore.Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weigth 455gms) complete all as specified and as directed complete all as specified and as directed
S & F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed
Removing debris to a distance of 1 KM including loading and dumping/ levelling at the destination complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets.complete all as specified and as directed.
Dismantling of AC/ galvalume sheets (corrugated and semicorrugated etc ) in roofing incl ridge tiles.complete all as specified and as directed.
Demolation of Brick or stone masonry built in cement mortar all as specified and directed...
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for as directed and specified by Engr-in-Charge
M & L for Point wiring concealed conduit in wall with 1.5 Sq mm copper conductor single core PVC insulated FRLS 1100 V grade multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1.6 mm thick MS, duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc complete all as specified and as directed. for One light point controlled by one, one way switch 5A, SP
All as per Sl item No 167 here in before, but for One ceiling / exhaust fan point controlled by one, one way switch and regulator
All as per Sl item No 167 here in before, but for One 2/3 pin 5 Amps socket outlet point controlled by one switch on the same board
All as per Sl item No 167 here in before, but for One 3 Pin 5 Amps switch socket on Independt board
All as per item No 167 above but using 4 Sq mm single core copper conductor cable multistranded PVC insulated 1100 Volts grade for 6/16 Amps switch socket combination point including running of 4.00 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. complete all as specified and as directed.
S & F Modular Switch 1 way 6 A, 1 Module capacity 230 Volts
S & F Modular Switch 1 way 16 A, 1 Module capacity 230 Volts
S & F Modular Socket, 6A- 2/3 combined 2 module of capacity 230 Volts
S & F Modular Socket, 6/16A- 2/3 combined 2 module of capacity 230 Volts
Supply and fix Modular ceiling fan regulator 2 module step type AC 240 volts suitable for 1200/1400 mm sweep complete all as specified and as directed. Note : For Item No 169 to 172 :- Modular cover plate with frame, Modular Metal Flush Box and modular switches will be inclusive of rate quoted.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and as directed. complete all as specified and as directed..
S & F lamp holder insulated body with back plate for angle/batten fittings fixed with wooden round blocks complete all as specified and as directed.
Supply and fix box type Wall mounted light fittings with LED lamp 18/20/22 W complete all as specified and directed by Engr-in-Charge.
Supply and fix 9/10 W Wall mounted LED tube batten along with integrated driver complete all as specified and directed by Engr-in-Charge.
S & F 34 watt recess softline luminaire (2x2) FLAT PANEL suitable for armstrong/grid ceiling with high brightness white LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal and all as directed by Engg in charge
S & F Security Lights of 1x35 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and directed by Engg-in-Charge. .
M & L bracket made out of GI pipe of 40 to 50mm dia medium grade not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thickness complete with MS nuts, bolts and washers etc bent to required shape complete all as specified and directed by Engg-in-Charge
S & F 10watt bulk head luminaire suitable for outdoor with high brightness giving glare free light and all as directed by Engg in charge
S & F Ceiling fan of 1200 mm sweep including provision of 3 core flexible copper conductor cable of size 23/0.0076 from ceiling fan and connecting up complete up complete up complete all as specified and directed (Note : Round flexible copper conductor PVC insulated 3 core multi stranded from ceiling rose to connector deemed to be included in the rate quoted by the contractor). complete all as specified and as directed.
S & F Vertical type TPN DB 8 way double door with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 200 Amps 25 KA with locking arrangement complete all as specified and as directed.
S & F MCB SP 6 to 32 Amps 240 volts for fixing in MCB DB's complete all as specified and as directed.
S & F MCB TP 100 Amps 415 volts for fixing in MCB DB's complete all as specified and as directed.
S & F MCB SPN 40 Amps 240 volts for fixing on MCB DB's complete all as specified and as directed.
S&F Metal Clad Socket 3 Pin 30 Amps industrial type with plug top and MCB SP 32 Amps all enclosed in sheet metal enclosure. complete all as specified and as directed.
M & L for Submain wiring with two single core 6 Sq mm PVC insulated, FRLS cable copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up of 6 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing complete all as specified and as directed.. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
M & L for Submain wiring with two single core 4 Sq mm PVC insulated FRLS cable copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up of 4 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing complete all as specified and as directed.. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom 1.75m long with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate)
S & F wall mounted box types LED Batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1x20 w watts, 230 volts, bipin holders, connector block, internally pre wired etc with necessary mounting arrangements including all accessories with new 3 core multistranded copper conductor of size 23/0.0076 from ceiling rose to fitting all as directed by Engineer-in-charge.
S & F wall mounted LED Batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1x9/10 w watts, 230 volts, bipin holders, connector block, internally pre wired etc with necessary mounting arrangements including all accessories with new 3 core multistranded copper conductor of size 23/0.0076 from ceiling rose to fitting all as directed by Engineer-in-charge.
S&F LED Light fitting 1x25 Watt complete with Bracket made out GI pipe med grade 25mm 1.2 Mtr long incl clamps and nuts botls etc , all as specified and as directed by Engr-in-Charge.
S & F switch piano type 5 A flush button single pole one way
S & F switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts all as specified.
S & F Metal body heavy duty Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louvre, 900 RPM complete all as specified and directed. Make Bajaj/Havells/CG
S & F MCB for single pole and neutral 20 amps, 240 V complete all as specified and as directed.
S & F for MCB single pole 6 to 20 amps, 240 V. complete all as specified and as directed.
S & F sheet metal enclosure for DBs Double door when MCBs to be used single pole and neutral with 200 Amps rated bus bar 240 V 4 way. complete all as specified and as directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable etc and getting out in Soft/loose soil complete all as specified and as directed.
Material and labour for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand all as specified and as directed (Compacted thickness shall only be measured and paid).
Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trench/poles/on wall all as specified and as directed. Make : Havells/KEI/Plaza
Material and labour for well burnt bricks, Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for FRLS cable protection complete all as specified and as directed.
Material and labour for galvanized iron tubing 32 mm bore light grade with all fitting for protection of FRLS cable, laid in trenches/wall/floor incl necessary clamp, bolt/nut if any all as specified and as directed. Note :- Excavation, earth work shall be measured and paid separately.
Cutting existing 50 mm steel bubing for alterations or additions, screwing existing steel tubing for inserting new tees or branch connection of size 25mm bore of pipe complete all as directed.
S&F ball brass valves 25mm dia, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as directed.
S&F unions 25mm dia, brass to connect iron to polythylene and fixed complete all as directed.
ATUL ENTERPRISES
K LAKSHMAN SINGH AND CO
BEEGEE DESIGN SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .