Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹492.5 CrAccepted-AOC | ₹492.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹10.1 LRejected-Finance | ₹10.1 L | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Requred machinery not fulfill required quantyty not fulfull and QR based Technical personal list not uploaded |
Tender Value
₹473.7 Cr
EMD Value
₹2.4 Cr
Closing Date
3 May 2024, 6:55 pmClosed
Executive Engineer, PWD, Division No.1, Nagpur.
Executive Engineer, PWD, Division No.1, Nagpur.
CONSTRUCTION OF NAGPUR SPORTS HUB AT MANKAPUR SPORTS COMPLEX,TAHSIL NAGPUR, DISTRICT NAGPUR MAHARASHTRA.
2024_PWR_1035441_1
pwc/ngp/div1/95-1/2023-24
Open Tender
Civil Works
900 days
At Nagpur.
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
via Net Banking
₹2.4 Cr
Chief Engineer Public Works Region,Civil Line,Nagp
13 Aug 2024
14 Mar 2024
6 May 2024
14 Mar 2024
3 May 2024
14 Mar 2024
28 Mar 2024
Amount
Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
Ground Floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Dismantling brick masonry in Mud and stacking the materials as directed with all leads, lifts etc. complete.
Ground Floor
Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller. (With prior approval of S.E.)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge.
First Floor
Second Floor
Third Floor
Sixth Floor
Eigth Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
First Floor
Second Floor
Third Floor
Sixth Floor
Eigth Floor
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
NATURAL BAMBOO CEILING: Providing & fixing of Wooden Grill panel with backer made of natural bamboo with 24mm Face black exposed grid. The Grill panels shall be made of rapidly renewable natural bamboo core having density 600+Kgs/m3 as per BS EN323 (1993) and bending strength of 96+ N/mm2 as per BS EN310 (1993). The Grill panel shall have a seven layer UV coating of thickness 0.09-0.11mm as per BS EN71 finished to natural or carbonized shades. The Grill panel shall be of nominal size 35x300x2400mm comprising 8 blades/slats of 35x16x2376mm with centre to centre spacing of 37.5mm fixed through Backer of size 12x22x300mm having centre to centre spacing of 300mm and additional end backers at 150mm from both the edges. The Grill panel shall have a fire performance of Class A according to ASTM-E84. The Grill panel shall have moisture content of 8-14% as per IS 1708 (Part 1):1986 and a Humidity Resistance (RH) of 70%. SUSPENSION: The tile shall be installed on 24 mm wide T - section flanges having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 43mm, 35mm and 30mm respectively. The deflection loading of the system shall be 17.8 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 21.4kg/m. The end details of the main beam and cross tee shall be made of pre hardened steel fixed to the ends. The cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 100 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All exposed panel ends to be covered using edge caps. All wall angles to be covered using ledgers. Installation should be carried out as per Manufacturer recommended procedure. The grid shall be installed with suspension system of recommended make. INSTALLATION: To comprise main runner spaced at 1200mm centre to centre securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centre to centre. Metal spring backer clips shall be used to fix the Grill panel to suspension system with a grid formation of 600mm along the blade/slat and 2 pieces along each backer (total 8 clips per full panel size) for every individual panel. Raise the panel up against the suspension system and align the backers with the suspension system. Push upwards on the spring backer clip to engage the clip tabs on to the suspension system flange. Ensure that both clip tabs engage the suspension system flange. SUSPENSION SYSTEM accessories manufactured and supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. Additionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners.
Ground Floor
NATURAL BAMBOO WALL PANELLING : Providing & fixing of Wooden Grill panel with backer made of natural bamboo with 24mm Face black exposed grid. The Grill panels shall be made of rapidly renewable natural bamboo core having density 600+Kgs/m3 as per BS EN323 (1993) and bending strength of 96+ N/mm2 as per BS EN310 (1993). The Grill panel shall have a seven layer UV coating of thickness 0.09-0.11mm as per BS EN71 finished to natural or carbonized shades. The Grill panel shall be of nominal size 35x300x2400mm comprising 8 blades/slats of 35x16x2376mm with centre to centre spacing of 37.5mm fixed through Backer of size 12x22x300mm having centre to centre spacing of 300mm and additional end backers at 150mm from both the edges. The Grill panel shall have a fire performance of Class A according to ASTM-E84. The Grill panel shall have moisture content of 8-14% as per IS 1708 (Part 1):1986 and a Humidity Resistance (RH) of 70%.
Ground Floor
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)
Ground Floor
Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 1962 (Revised) with approved face veneers on side and Laminated on other faces with /without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter
Ground Floor
First Floor
Second Floor
Third Floor
Eight Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete
Ground Floor
First Floor
Second Floor
Third Floor
Eight Floor
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary.
Ground Floor
First Floor
Second Floor
Third Floor
Eight Floor
2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. with prior approval of concerned Superitending Engineer (For Detailed wording of Item Plese Refer Tender Bboklet)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
2 Hour Insulated, Flame, Smoke Radiation check Lead Lined Fire Door 57mm 2HR FRL (120/120) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. with prior approval of concerned Superitending Engineer (For Detailed wording of Item Plese Refer Tender Bboklet)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
First Floor
Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmD Providing and fixing Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm. GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor & does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns).
Ground Floor
First Floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
First Floor
Second Floor
Third Floor
Sixth Floor
Seventh Floor
Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs.
First Floor
Second Floor
Third Floor
Sixth Floor
Seventh Floor
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint)
Second Floor
Third Floor
Fourth Floor
Sixth Floor
Eight Floor
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing mild steel grill railing weighing 15Kilogram/ One Square Metre. with PVC handrail cover and newel post for staircases, including fabricating, fixtures, drilling holes in concrete / other surface, erecting the grill work, necessary welding, fixing by nuts and bolts, fixing PVC handrail cover, with one coat of anticorrosive paint and two coats of oil painting with approved colour and shade, remaking the damaged surface, cleaning, etc. complete. Spec. One Number : As directed by Engineer in charge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Two Track Two Glass Shutter Window : Providing and fixing aluminlum color anodized system sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson 25 to 27 mm slim series or equivalent system. Windows will be of specially extruded aluminium 2 Track - 2 Glass shutter window/ventilator, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with SS 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5mm clear toughened glass, All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to from uniform hairline joints, All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single points self pressing lock. All fixing screws will be of SS 202. Windows will be sealed with weather sealant from outer periphery, etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Tlhree Track Three Glass Shutter Window : Providing and fixing aluminlum system color anodized sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson 25 to 27 mm slim series or equivalent system. Windows will be of specially extruded aluminium 3 Track - 3 Glass shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with SS 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5mm clear toughened glass, All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to from uniform hairline joints, All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single points self pressing lock. All fixing screws will be of SS 202. Windows will be sealed with weather sealant from outer periphery, etc. all complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Tlhree Track Two Glass + One Net Shutter Window : Providing and fixing aluminlum system color anodized sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson 25 to 27 mm slim series or equivalent system. Windows will be of specially extruded aluminium 3 Track - 2 Glass +1 net shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with SS 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5mm clear toughened glass, All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to from uniform hairline joints, All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single points self pressing lock. All fixing screws will be of SS 202. Windows will be sealed with weather sealant from outer periphery, etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Solid core Flush Door Single leat Providing and Fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailled drawings, conforming to I.S. : 2202-1962 (Revised) with approved face Laminate on both faces with / without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings, finishing with trench-polish/ waxing complete. (without door frame). (Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and laying Vitrrified tiles (Matt and Antiskid Finish) in floor in 500 milimeter x 1200 millmeter sizes ( thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to Is @ 15622, of approved brand and manufacturer, in all colours and shade, laid on 20 millmeter thick cement mortar 1:4 (12 cement 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments excetra. The tiles must be cut with the zero chipping diametermond cutter only. Laying of tiles will be done with the notch trowel, pller wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily. as directed by engineer-in- charge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Wall CladdingWall Cladding with Terracotta desiner iali Designing, Supplying and fixing of Terracotta desiner jali of nuvocotto or equivalent make of size having 200x200x60mm as per manufacturer finished with approved colour and pattern. The blocks shall be fixed by suitable system by using mortar or special ready mix mortar orr adhesive per manufacturer guidelines and specifications with suitablable thickness of joing material, size and spacing to withstand the structural design criteria specified, supported or locked by beams or columns as per design height criteria of the cladding as per manufacturer technical specification, cladding joints should be with per design and drawings including cutting, jointing, fixing scaffolding, cleaning, lead, lifts handling etc. complete as shown in design, drawings and specifications as directed by engineer & in charge. Sample needs to get approved from project architect before execution of work. (If MS work required it will paid seperatly)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing & Fixing Aluminium color anodized sliding & folding door 3 shutters having special patented frame & shutter profiles. Oter frame profiles being fixed to the misionary with SS-202 screw shutters having 45 degree corner joints with special cleats for linear joints having 6mm toughned glass are installed in the frame structure with mortise lock at opening, Top $ bottom pivots for sliding, but hinges for folding operation & subsldlary multi point locking & pop handle for additional security complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Aluminium System color Anodized Fixed Window : Providing and fixing aluminium system color anodized fixed window of various sizes. Casement will be made from Gaata / Malwin/Lexil/ Brandson 40 mm series or equlvalent system window will be of specially extruded alluminium section, joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonory opening of windows with SS 202 wood screws. Fixed glass casement will be made from specially extruded alluminium section, glass considered is 5mm clear toughned glass. All shutter will be having 45 degree joints, joints will be fixed fixed with specially developed clits to form uniform hairline joints. All fixing screws will be of SS 202 windows will be sealed with weather sealant from outer periphery etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
S.S. Railing : Providing and fixing matt finished stainless steel (Grade 304) railing with 60 milimeter x 40 milimeter and 1.6 milimeter thick pipe as handrail at top, 40 milimeter x 8 milimeter vertical pattl placed at 1148 milimeter center to center, 40 milimeter x 8 milimeter horizontal patti placed at bottom 100 milimeter above the flooring, 12 milimeter diametermeter pipe placed vertically in between handrail and bottom patti at 150 milimeter c/c and 75 milimeter c/c alternately as shown in the drawing. including buffing, fabricating fixtures and fastering including base or cover plate of appropriate size as directed by Engineer in charge excetra. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing white Opal series European type wall-hung, of size 400 mm x 370 mm x 575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing white wash basin with half pedestal of size 515mmX615mmX460mm including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32mm diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.
First Floor
Second Floor
Third Floor
Fourth floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Ground Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Ground Floor
First Floor
Sixteen Floor
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Ground Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing 20mm diameter water meter with non-return valve including strainer, sockets/ union nut including water meter box making locking arrangement and lock. (without chamber).
Ground Floor
First Floor
Providing and fixing 50mm diameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber]
Ground Floor
Providing and fixing 80mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock.[Without chamber].
Ground Floor
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete.
Ground Floor
Second Floor
Third Floor
Sixth Floor
Eight Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing internal / external 20 mm thick Ready Mix plaster confirming to IS:4031(Part-4) 1988 and IS 383-1970 in a single coat using Cement mortar of proportion 1:4 containing special type of polymer additives about 0.4%, to all type of surfaces in all positions including scaffolding and curing complete
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and applying Texture plaster of STONETEX - TRAVERTINE SERIES - ST- 2002 special iuxurious stone finish coating (3 product type - 6 coat system) for exteriors and interiors, Texture midcoat incorporating natural stone granules like natural sandstone, Granite, Limestone, Ceramic chips, natural sand etc. including grooves to be provide as per design and drawings. Apply two coats of under coat primer by roller or brush then apply masking tape to create grooves as per design and drawings. First coat of texture midcoat finish by spray gun, evenly over the entire surface. Apply second coat of texture midcoat finish by spray sprinkle method, evenly on the whole sea of the pravisously dried first coat. Apply two coats of top protective coat evenly on the surface including grooves with roller or brush. It should be water based and acofriendly product including preparing the surface, scaffolding etc. complete as directed by Engineer in- charge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Panic Bar: (For 2 Hr fire Rated single Panic bar) Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style ,made of heavy duty cast iron/ steel body & latches with SS ,BHMA certified & conforming to ANSI A 156.3 for grade-1 ( 3 hours fire rated ) and suitable for surface mounting to wooden/hollow metal/ Al framed door,with maximum operating force 8Kilogram for unlocking easily & outwardly during emergency,complete in all respect as per direction & satisfaction of Engineer-in charge including all taxes & incidental charges. (Note: To be installed at "FIRE EXIT"only under location specific instruction of Eingineer-in -Charge.)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
Ground Floor
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
Ground Floor
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Ground Floor
First Floor
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
Ground Floor
First Floor
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.
Ground Floor
Four Track Three Glass+ One Nat Shutter window : Prividing & Fixing Aluminium System anodized sliding windows of various sizes, Sliding will be made from Geeta / Malwin / Lexil/Brandson 27 mm stim series or equivalent system, Windows will be of specially extruded aluminium 4 Track-3 Glass +1 net shutter with Bottom fixed. Fixed Glass at Bottom as per drawings would be fixed on 40 mm Casement Series Frame section & Single glass glazing clip both having 45* joints with special cleats & fixed to missionary by SS 202 wood screws. The Sliding Window Track mounted on Special Square Aluminium section, The track fra me will be fixed to the masonry opebning of windows with SS 202 wood screws. Glass shutter will be mad from specially extruded aluminium section, glass considered is 6 mm clear Toughehed Glass. All shutters will be having 45* joints, joints will be fixed with specially developed clits to from uniform hairline joint. All Shutter will be fixed to the main frame with necessary double roller to have smooth & easy movement of the shutter. Shutters will have single point self pressing lock. Windows will be sealed with weather sealant from outer periphery, etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Aluminium System color Anodized Partly Fixed partly Openable Window : Providing and fixing aluminium system color anodized partly fixed partly openable window of various sizes. Casement will be made from Gaata / Malwin/Lexil/ Brandson 40 mm series or equivalent system. windows will be of specially extruded aluminium section, joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with SS 202 wood screws. Fixed glass casement will be made from specially extruded aluminum section, glass considered is 5 mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform halrline joint. All fixing screws will be of SS 202. Window will be sealed with weather sealant from outer periphery, etc. All complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
METAL FALSE CEILING WITHOUT SUSPENSION SUPPORT FROM TRUE CEILING: Providing & fixing horizontal level suspended metal ceilings comprising of Metalworks F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions with Rectangular panels made of 0.7mm thick Galvanised Steel (GI) of 120gsm, post coated to Global White colour, suitable for Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300mm, length ranging from 1500mm to 2660mm. General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7mm as per in IS:513 (1994). Dimensions: The panel Length varies between 1500mm to 2660mm, panel Width shall be 300mm. The dimensional tolerances for length shall be ±1.0m up to 1000mm L; ±1.5mm between 1001 to 2000mm L; ±2.0mm between 2001 to 3000mm L. The dimensional tolerances for width shall be ±0.5m up to 300mm W. Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3mm(W) x 8mm(H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturns of minimum 30mm (H) and shall be bent appropriately bent as per the manufacturer’s specifications for providing hook-on ends. The long side shall have inside horizontal bends of 5-15mm for rigidity and vertical upturns of 40mm (for length ranging from 1251-2660mm). Surface Finish: Plain: The panels shall be in plain unperforated finish (without any acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017, 250 hours of condensation test (as per DIN 50017 or DIN EN ISO 6270-1 Norms), UV resistance of 500 hours and 50% gloss retention (as per ASTM G 154 UVB-313 Norms). The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E (∆e) <1 measured using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523.The colour / shade to be Global White (Polyester for Interior) as approved by the Architect or Engineer-in-charge. Surface Protection: The visible panel surface shall be protected using a guard film made of LDPE of 50µ thickness, having appropriate surface adhesion (or tackiness) corresponding to surface gloss level. Light reflectance: The panel shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98. Flatness and Sag limit: Panels shall be flattened by precision leveller to minimize sag to less than Length/400mm. The difference between the two diagonal dimensions of the panel to be less than 1mm. The sag to be measured at the center in accordance with TAIM standards. Access and Plenum space: The panels to be Fully Accessible, with system height of 98mm, and would require a plenum height of a minimum 450mm clear space from bare ceiling / rigid structure for installation. Packaging: The Panels shall be packed in wooden crates of appropriate dimensions based on panel sizes. The wooden planks for rates shall have thickness of approx.15mm, width of around 4” and gap between two planks around 3”. Crates to have layer separators of 1” x 2” dimensions to prohibit load transfer on bottom panels, and the crates lifting to be 2way or 4way. The bottom of crates shall be completely closed, and the panels kept inside shall have cushioning of corrugated sheets or other appropriate material. Installation Specifications: Primary and secondary runners Installation: U-Profiles, spaced at 1200mm, to be suspended from ceiling using clamping brackets and threaded rods OR hanger wires. Hanger wires must be wrapped tightly with 3 full wraps. The J-Bars (directional) shall intersect the U-profile at 90° at every module dictated by the panel length. The J-Bar is connected to the U-profile with a J-Bar hanger and secured to the matching square U-Profile slots using plug-in clips. Self-tapping screws to be used when square U-Profile slots do not match the hangers. The U-profiles and J-Bars be fastened to two adjacent walls using the wall anchor and bolts. U-Profiles and J-bars to be at a maximum distance of 450mm (max.) to a perimeter wall or outside edge of a floating module. To join two pieces of continuous U-profiles and J-Bars, a U-Profile splice and J-Bar splice to be used respectively. Panel Installation: Full size metalworks R-H 200 panels (directional) to be hooked on to the J-Bars (in accordance with the shop drawings) along the short side (typical) to cover the span / width of the corridor. Field-cut Panels: Perimeter panels that require field cutting to fit on a wall trim option must have a minimum of 12mm edge resting on the horizontal surface of the wall moldings. Wall Moldings: 19x19 wall angle to be fastened to the perimeter using screws, at every 450mm to 600mm L. Warranty: The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate.
Ground Floor
First Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and erecting Alluminium centering ang shuttering including strutting propping , making of grooves,dots etc including rendering with proper additives like Dr. Fixit 302 Super latex or quivalent,white cement,grey cement and removal of formwork for exposed formfinished RCC members like columns,beams,pardi,slabs etc complete.as directed by Engineer In Charge. a) Second floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.
Providing and fixing in position TMT FE 500, 32 mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.
Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.
Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 900mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb with gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant
Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary)
Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete.
Providing and installating the Statue of maximum size m wide x 2m long x 3m high of granite stone material as per the design and drawing provided by the Architect including all required cutting, grinding, finishing polishing etc. Required detailed shop drawing and sample is needs to get approved from the project architect before execution on site. Work shall be carried our including alll lead and lifts etc complete as directed by Engineer-In-Charge.
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 50 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 6.33 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 80 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 10.15 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing , constructing and fixing 250 mm dia. Inspection chamber made up of UPVC material of thickness 3.5 mm and height of 259 mm with inlet and outlet of 110 mm dia. with 75 mm dia. U Trap, Ultra shaft pipe of Upvc material having height of 470 mm and fixing Ultra 250 mm dia. UPVC cover and frame in 150 mm thick in c.c.1:2:4, having crushed sand bed of 100 mm thick of size 550 mm dia. Including excavation and refilling the sides of chamber by crushed sand cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete.
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer.
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete.
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete.
Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram)
Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (160 Kilogram)
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately etc. complete.
Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 mOne Metric Tonneo 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide)
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing cast in situ / ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA
Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete.
Providing and laying perforated PVC 160 mm dia pipe in proper line,leveland slope including necessary material fitting etc. complete.
Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring.
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings
Providing and Fixing of Median Marker that are made of tough, high impact resistant, injection-molded, thermoplastic body with an isosceles trapezoidal structure of length, width and height not less than 15cm, 10cm and 10cm respectively and thickness not less than 1.8mm, the body structure shall be rounded at its acute angle, all the corners and edges. The plastic used for molding the Median Marker shall have a minimum Notched Izod Impact strength value of 600 J/m at room temperature, when tested in accordance with ASTM D256 and shall retain at least 70% of this value when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL746C. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The Median Marker shall have rectangular-shaped, fluorescent yellow color retro-reflective sheeting of size not less than 8.5cm*8.5cm and with fully reflective micro prismatic cube corners as its retro-reflective elements as per IRC 67 2010 and ASTM D4956 type XI specifications reflectivity values. The retro-reflective sheeting shall be one or both sides of the Median Marker and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage, etc. The Median Marker shall be fixed by a combination of epoxy adhesive and grouting.
Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at centre to centre distance of 35 mm, with reflective glass beads @ 350 gm / One Square Metre. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. complete.
Supply of self watering system tree guard in 110 mm dia, 1.80 mt height made up of cotton canvas cloth of polymer pipe of 15 litres water storage capacity stand with 2 nos. 40 mm dia treated bamboo of 2 mt ht. tie with tag at two nos and specially designed dexpandable rubber seal 110 mm dia outer & 25 mm dia. inner dia installed on bottom of pipe, and 0.60 m long HDPE lateral pipe 2 nos 5mm dia to carry the water near root zone connected with gromate fix in treeguard and rapping 1.20m long barbed wire to middle of treeguard for protection agianst cattles and other external factors as per specification. ( cost of plant & fixing charges will be extra as per approved rates). (Note :- Plant height should be required above 2.50 m & Dia of stem 25 mm at bottom )
Fixing and Transporting of self watering system tree guard-insertion of sapling in self watering tree guard and capping the bottom with expandable rubber seal. Supporting the bamboo with the help of cable tie. Bamboo to be buried 0.15 mt ht. below of excavated pit. Strengthening the bamboo in pit with adequate measures. Circulating the barbed wire around tree guard at middle ht. from bottom and fixing it. Thr rates excluding the cost of barbed wire, bamboo, expandable seal, tree guard and all other required material. Fixing to be carried out as per manual instruction.
Transportation of material obtained from debris of various sorts excavated stuff including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. ( Beyond 10 Km. )
Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs.
Filling fresh garden soil / silt & manure in excavated pit size area of 1.00 x 1.00 x 1.00m
Maintainance of Newly Planted small & medium size ornamental plants/ Specimen plant. For First 30 days Only
Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 1 x 1 x 1m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 19.85/-
(a)Flowering Shrubs, Ixora mini Bag Size 8" x 10", Height of plant 15 cm to 30 cm
(a)Flowering Shrubs, Russelia, Bag Size 7" x 8", Height of plant 15 cm to 30 cm
(b)Foliage Trees, Deshi Badam, Bag Size 13" x 13", Height of plant 6 ft to 8 ft
(a)Hedges, Bongainvillea, Bag Size 7" x 8", Height of plant 20 cm and above
(a)Hedges, Ribbon grass/Phalaris, Bag Size 7" x 8", Height of plant 10 cm to 20 cm
(b)Palms, Supari, Bag Size 13" x 13", Height of plant 4 to 6 ft.
(b)Palms, Sealing Wax Palm, Bag Size 15" x 16", Height of plant 5 to 6 ft.
(b)Palms, Fox tail palm, Bag Size 15" x 16", Height of plant 5 to 6 ft.
GARDEN SOIL:-Supplying on site garden soil well sieved 80 % to pass through I.S. sieve of 10 mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The color of the soil generally is red. The soil will be measured by measuring box. (Farma) Item includes Transporting, loading -unloading etc (.Lead charges per 25 km. considered Excluding royalty.)
Executive's Table @ 1800Lx900Dx750HT Providing & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing.
Ground Floor
Second Floor
Fifth Floor
Sixth Floor
Seventh Floor
Library Area Table @ 1350Lx750Dx750HT Providing & Fixing of FREE STANDING TABLE @ 1350Lx750Dx 750HT:- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, BENT LEG to be CHROME FINISH as per drawing.
First Floor
Second Floor
Third Floor
Conference Table @ 3600Lx1400Dx750HT Providing & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos.
Second Floor
Sixth Floor
Seventh Floor
12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.
First Floor
Second Floor
Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing.
Ground Floor
First Floor
Second Floor
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Single Bed @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow. Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Bed Side Table @ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding
Ground Floor
First Floor
Second Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing a folding wheelchair of Pioneer Surgicals Brand, model One Number PS 809/ equivalent make as per the directions of the engineer in charge.
Ground Floor
Canteen Chair : 6 chairs : size :- 530 mm w x 500mm d 815mm h specifications :- the tubular understructure is fabricated from 19.0 x 1mm thick Ss 202 grade tube welded together with ss connecting rod 8.0 mm. The undestructure is provided with black pp injection moulded ferrules.
First Floor
Statinless Steel Table for Canteen overall size 44" Long and 30" Width and 30" Height by using Stainless stel grade 304 sheet of 14swg thick and frame by stainless steel angles of 30mm x 30mm x 3mm thick with cross suport in stainless steel pipe 25mm x 25mm x 16 swg thick. using stainless steel leg pipe 32mm x 32mm x 16 swg thick with adjustable nylon bullets including fabrication work of Aragon are welded joints granted and finished in mat. Approximate weight of Table 28 kg.
First Floor
Statinless Steel Table for Canteen overall size 66" Long and 30" Width and 30" Height by using Stainless stel grade 304 sheet of 14swg thick and frame by stainless steel angles of 30mm x 30mm x 3mm thick with cross suport in stainless steel pipe 25mm x 25mm x 16 swg thick using stainless steel leg pipe 32mm x 32mm x 16 swg thick with adjustable nylon bullets including fabrication work of Aragon are welded joints granted and finished in mat. Approximate weight of Table 32 kg.
First Floor
Providing & Fixing in position, Acoustical Panelling made from 12mm wp Ply wood & 1.5mm laminate on, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete
Ground Floor
Second Floor
Sixth Floor
Seventh Floor
Providing and constructing non load bearing wall with 100mm Horizontally perforated clay hollow blocks of approved make with compressive strength not less than 35Kilogram/Sq.cm, U value of 47.0 W/m2k, Water Absorption of 15%, with cement mortar 1:6 with blocks of size 400mm x 100mm x 200mm (12.5 bricks per Square Metre. excluding mortar joint thickness) At every 5th course level, Concrete band of 100mm thick with 1:3:6 Mix Concrete along with Nominal Reinforcement to be provided. The rate inclusive of cost of materials, labour charges, scaffolding, curing at all height, complete as per specifications & directions of Engineer-in Charge. Cost shall be inclusive of filling the Blocks with Cement mortar at exposed junctions and filling with concrete using 12mm down size aggregates at Window and door Jambs for fixing hold fast, anchors etc.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing & fixing Podium wherever required of size 600x600x1275mm height with following specification table top, side & bottom- 18mm thick plywood with Fomica laminated sheet & CCWT battens 25x12mm moulding, including all leads and lifts etc. complete as per drawing and as directed by engineer in charge.
Second Floor
Providing and fixing on site notice board made out of 6 mm marine ply of the requisite manufacture generally confirming to I.S. 310/I.S. 710-1980 backing and 12 mm thick soft board covered with tapestry/up to Rs. 200 per meter including necessary lipping (BTC), moulding, hardware, polishing etc. and Anti-termite treatment to plywood and woodwoork with ten years guarantee bond etc. including all leads & lifts etc. complete as per Architect Drawing and instructions of Engineer in Charge.
First Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Storage Full Height : Providing and fixing 53cm deep cupboard type storage Unit made out of 19mm thick marine plywood of the requisite manufacture generally confirming to IS 710-1980 for frames, internal verticals horizontal divisions, shutters and 6mm & 2mm thick marine plywood for drawers with locks, handles, hardware, lipping & beading patti (BTC) etc. The shall be finished with veneer in approved pattern with grooves etc. and two coats of french polish and melamine polish for all BTC moulding & lipping patties with antitermite treatment to plywood & wood work with ten years guarantee on requisite stamp paper including all leads & lifts etc. complete as per drawing and instruction of Engineer-in charge etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader / Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - I Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means -Grading I (Using Screening Type B (11.2 mm) Aggregate)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate)
Providing, laying and compacting of Built-up-spray grout layer 75 mm thick over prepared base consisting of two layers composite construction of compacted crushed coarse aggregates with application of bituminous binder of biyumen of specified Grade @ 1.520 Kg/ Sqm after each layer, ( i.e 1.520x2=3.04 say 3.00 Kg/Sqm) and with key aggregates placed on top of the second layer and compacting with static roller 8 to 10 MT. Excluding cost of tack coat and scarifying etc. Complete.(VG-30 bulk bitumen rates are considered to arrive at rates)
DENSE BITUMINOUS MACADAM:--Providing and laying dense bituminous macadam using crushed aggregate of grading 1, premixed with bituminous binder Bitumen of specified grade,@ 4.50 % by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface , finished to the required grade ,level, alignment,and rolling to achieve the desired density for 76/100 mm compacted thickness with drum mix type hot mix plant with SCADA having complying essential features of Hot mix plant as per IRC-27-2009 specified conditions and attachments such as electronic load sensor based belt conveyers, automatic synchronization of bitumen and aggregate fedder,built in dust controller system and PLC for Drum Mix plant ,Sensor paver, and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen VG-30 grade with stone dust filler (VG-30 bulk bitumen rates are considered to arrive at rates)
BITUMINOUS CONCRETE:- Providing and laying bituminous concrete using crushed aggregates of grading 1, premixed with bituminous binder @ 5.20 per cent by weight of total mix and filler, transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction for 50 mm compacted thickness with specified grade of Bitumen,Excluding prime / tack coat. For Bitumen of specified grade -- USING Batch mix type hot mix plant with SCADA, Sensor Paver, Vibratory roller with Stone Dust filler. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying tack coat on the prepared surface heating by flames in Boiler and spraying bitumen with sprayer on Granular surface treated with primer @ 2.75 kg/10 sqm(VG-30 bulk bitumen rates are considered to arrive at rates)
Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
Spreading hard murum/ soft murrum/ gravel or kankar for side width complete
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.
Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately etc. complete.
Supply and installation of 8 layer cushion Acrylic Sprots Surface of KDF make or equivalent in layers as below: Primer 1 layer,1 layer of Resurfacer, 2 layers of heavy cushion, 2 layer fine cushion, 2 layer of texture colour and line marking as per ITF standards and manufacture r should hold minimum 3 classification of ITF.
Supply and fixing of Height adjustable fixed type Basketball post with 3.2m extension in 8" round pipe with proper foundation of 600mm x 600mm x 600mm below the floor level with Transparant Acrylic Backboard with markings as per FIBA guidelines of 25mm thickness and 3 spring dunking rings and suitable nets.
Chemical Treatment of the entire area to make the land infertile and this will be done manually by spraying of required chemicals
Supply and fixing of fixed type Tennis post with brass rachet with proper foundation of 450mm x 450mm x 450mm below the floor level with suitable nets and centre tape.
Providing and Fixing extra BWF / FIBA / FIVB certified Flooring Prepolished hard maple. etc complete
Providing and fixing polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete
Supplying and Fixing Glass Blue Mosaic flooring 20x20 mm thickness 5 mm rubbed and polished to granolithic finish, under layer cement concrete with white, black, chocolate, grey, yellow or green tiles chips of sizes from 1 mm to 4 mm nominal size, laid in chemical ARTEX ENDURA
Supplying and applying High performance hybrid polyurea elastomeric/Crystaline waterproofing coating cold applied of spray / brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, repair of cracks and construction joints with epxoy mortar,epoxy primer application and applying SmartCare Ultron or approved equivalent in two coats at 1kg per Sqm etc, complete as per Manufacturer specifications.
PROCOPI S.A (France): Supply of Filter TOTALLY ANTICORROSIVE Bobbin Wound filter, 2000mm diameter. Polyester+Fibre Glass commercial filter . Blue colour.The polar type of pipe connection with top entry and bottom exit without any piping and pipe laterals inside the filtre. The dome lateral at the bottom with multi grade, 4 layer of filter media for a high quality filtration . Filtration velocity 40m³/hr/m². Max. working pressure : 2.5 kg/cm². Flow rate =125m³/hr.Pipe size- 160mm,Test Pessure -3.75bar ,including face plate with 2 pressure guage with sampling valves and Turbidity sight glass size 160mm. Make: Procopi S.A ,France
PROCOPI S.A (France): CHEMICAL DOSING SYSTEM FOR POOL ACID AND CHLORINE Electromagnetic dosing pump to be mounted both on its base as well as hung on the wall. Pumps following CE regulations. IP- 65 protection. Power connections : 230V, 50/60 Hz. Dosing pumps are Equipped with a pulse frequency controller and a water level detector. dosing pumps are proportional ,this allows for gradual regulation .In the case of pH regulation it prevents decarbonisation and preserves water's ntatural equillibrium. Flow 20lr/hr @ 10bar. Make: Procopi S.A, France
Supplying of Starting Block in SS 316 grade Electroplated with 500x500mm antislip Platform in Blue colour. Height 700mm fixed with Backstroke starting Handle and necessary anchoring bolt. Make : Aquafine - Make in India
Supplying of UPVC Float lane with float diameter 150mm , assembled on SS rope - . With complete stainless steel spring tensioners, hooks, Tightener with all other accessories. Make: Aquafine - Make in India
Supplying to Site and fixing in position Float Line deck anchors made in S.S Make:Aquafine - Make in India
Supplying to Site and fixing in position Life Buoys with SS support to be fixed on the swimming pool deck to be used in emergencies. Make: Aquafine - Make in India
Supplying of Lifeguard Hook. Make:Aquafine - Make in India
Supply of Life guard chair, Frame made of SS316 grade with a 43.mm tubing, seats in plastic and base in SS316 with wheels. Make:Aquafine - Make in India
False start indicator in SS304 of 38mm dia Make:Aquafine - Make in India
Anchor for False Start Indicator Make:Aquafine - Make in India
Back Stroke Indicator in SS 304 of 38mm dia Make:Aquafine - Make in India
Anchor for Back stroke indicators Make:Aquafine - Make in India
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
CUSTOM PRINTED ACOUSTICAL FALSE CEILING :Providing & Fixing of Custom color Printed Mineral Fibre Acoustical Suspended Ceiling System with 19mm thick Microlook 90 Edge Tiles with 15mm face exposed grid. The tiles shall have smooth bright laminated visual with Humidity Resistance (RH) of 99%, NRC 0.7 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 41db as per ASTM E1414, Light Reflectance ≥87% as per ASTM E-1477, Thermal Conductivity k = 0.045 - 0.048 W/mK, Colour Global White, Fire Performance of Class 0/1 as per BS 476 Part6/7 and Class A as per ASTM E 84 with 19mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable, soil and scratch resistant and having superior scrub-ability (Gardner Test). The tiles shall be classified as ISO 14644-1 cleanroom class 5. The tile shall have a rating of 8 or above for tests conducted for Resistance to growth of Mold in accordance to ASTM D3273. It shall be suitable for Green Building application, with Recycled content of 36%. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on with 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications above) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per Manufacturer recommended procedure. SUSPENSION SYSTEM accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners)..
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Stamp Concrete of 100mm Thickness - Providing and Laying in-situ M30 Grade unreinforced plain cement stamp concrete of 100mm thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / VSI grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site in nagpur city with lead upto 20KM (on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast UV resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @5kg per sqm. Including texturing, and covering with plastic sheet (min 200 micron thickness) and also applying two coats of UV-stable,30 % solids clear sealer @ 150 to 250 gms per sqm using surface roller and protecting from falling dust,dirt and curring by curring compound / by providing cement vata in cement Mortor 1 :8 @ 0.6m x 0.6m center to center, admeasuring 80mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-incharge or Landscape architect etc. complete. (prior approval of superinteding Engineer will be necessary )
Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Providing and applying Anti corrosive treatment to reinforcement as per cement polymer composite coating (C.P.C.C.) method developed by C.E.C.R.I. including cleaning the bar by means of any established mechanical or manual method for removing rust and deleterious material, applying rapid setting primer and cement polymer sealing coat of approved and licensed by CECRI including redoing the process if damage occurs during handling, stacking etc. complete. (With prior approval of SE)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Basketball Synthetic Sports Flooring of 7.5nn FIVB - Federation International of Volleyball Approved (Taraflex)
Hard Maple Wooden Flooring (USA) FIVB - Federation International of Basketball Approved (Taraflex)
Providing and fixing 12mm thick clear toughened glass fixed to aluminium U channel of size 25mm*19mm*3mm at bottom and top 75 x 75mm SS box section vertical and horizontal support, using RSF-F- 4P four arm fin spider, RSF-F-2P two arm fin spider, RSF-F-1P one arm fin spider, MS fin shoe bracket, with cover nut and bolt including packing and filling with chemicals, sealant and masking tape, cost of material,transportation, handling,fabrication, site supervision, contingencies complete as directed by EIC (excluding civil work, if any)
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing of 12mm thick frameless toughened glass partition fixed to 20 x 20 x 1.5mm Aluminium U channel section at top and bottom with necessary sealent and hardwares., complete as per specification and drawings and complete as directed by EIC
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement, SS brushed C-Handle, bottom patch lock and making necessary holes etc., for fixing required door fittings, all complete as per specification and drawings,complete as directed by EIC Ground Floor
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Drilling of 150 mm dia Bore well ( DTH ) in all sorts of soils, Hardrock removing excavated suff of the soil, Murrum strata 200/215 mm dia in hard rock 150 mm dia with wet Driling
Providing and incerting casing of 150 mm diameter of Cast Iron Pipe 4.80 mm thk. (MSERW) Mediam Class incliding grouting as per IS 1239 ( including lowering and handling etc. ) with Socket
Testing of Yields of water of borewell by Air Lift Method By Flushing
Providing and Fixing steel Cap(IS 1239) For threaded iron casing pipes including all accessories etc.complete.
Procopi S.A (France): Over-flow channel grating in Polypropylene, 295mm for 300mm ,1 Module - 69cm ( 33 integrated bars ), mm, White colour. Maximum stress loading 190 DaN/100 sqcm. Withstand UV light and exposure to weather. Aesthetic and Antislip. Flexible and can be easily adapted to almost any shape. Make: Procopi S.A ,France
Procopi S.A (France) : 90 deg Corner tiles for gratings 295mm for 300mm Make: Procopi S.A ,France
PROCOPI S.A (France: Supply of FAIRLOCK concrete Vacuum Head (48cm) with brushes and wheels. Make: Procopi S.A ,France
PROCOPI S.A (France):Vacuum hose 11/2" dia, of approved colour 25mtrs long including hose cuffs for connection to suction inlets. Make: Procopi S.A ,France
PROCOPI S.A (France): Deep bag net made in polypropelene and Blue polyester netting. Make:Procopi S.A ,France
PROCOPI S.A (France): Surface net made in polypropelene and Blue polyester netting . Make: Procopi S.A, France
PROCOPI S.A (France): Curved brush made in polypropelene with Aluminium reinforced for pool basins and scum liners. Make: Procopi S.A ,France
PROCOPI S.A (France): Algae brushes with stainless steel bristles. Make: Procopi S.A, France
PROCOPI S.A (France): Test kit for free chlorine & pH. Make: Procopi S.A , France
Providing & Fixing Fresh Color Restroom Cubicles Systems in Model Name - Solace SS Model , Comprising of Thickness of Compact Laminate : 12 mm Accessories :- SS - 304,Adjustable Foot - SS,Screws - SS,Door Lock - SS,Hinges Auto Return - SS,Cloth Hook - SS,Extruded Anodized Aluminum Door Stopper,Extruded Anodized AluminumTop Rail -,Extruded Anodized Aluminum"U" Channel - The whole system will have Upto 150 mm clearance height to the floor.Toilet Cubicle System ( L Shape ) with Standard Dimension of 1950 mm Height x 900 mm Width x 1500 mm Depth, Which Includes a 600 mm Width x 1750 mm Height Door.
Providing & Fixing Fresh Color Restroom Cubicles Systems in Model Name - Solace SS Model , Comprising of Thickness of Compact Laminate : 12 mm Accessories :- SS - 304,Adjustable Foot - SS,Screws - SS,Door Lock - SS,Hinges Auto Return - SS,Cloth Hook - SS,Extruded Anodized Aluminum Door Stopper,Extruded Anodized AluminumTop Rail -,Extruded Anodized Aluminum"U" Channel - The whole system will have Upto 150 mm clearance height to the floor. Front Panel ( I Shape ) with Standard Dimension of 1950 mm Height x 900 mm Width x 1500 mm Depth, Which Includes a 600 mm Width x 1750 mm Height Doo
Providing and erecting self supporting profolex roofing system for SWIMMING POOL of made up structural grade of steel of 914 milimeter .moulded at site using mechanical press dies to the disireed curve and shape to form 605 mm wide interlocking pannels the interlocking pannels shall be pressed to close the seam following water tight joints as per requirements the base material made up of imported galvolume steel complying to ASTM A792 having base metal thickness of 0.80mm with aloy coating AZ 150 And paint coating regular modified polyster .top coat 25 micron and bottom coat 12 micron as per approved colour.including fixing hangers clamps etc.as may be necessary of profolex standard .Including and fixing sky light of 2 mm thick polycarbonate sheet of size 2 inches x14 inches turbo ventilator of 24 inches diameter to be installed properly along with length of roof including fixing testing and cleaning etc complete
Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction material for which royalty is necessary.(For Sand)
Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction material for which royalty is necessary.
Carrying out testing BASIC TEST OF CEMENT. Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness.
Carrying out testing BASIC TEST OF AGGREGATE. Water Absorption, Specific Gravity,Impact Value, Crushing Value.
Carrying out testing BASIC TEST OF AGGREGATE.Sieve Analysis.
Carrying out testing BASIC TEST OF AGGREGATE.Abrasion Value.
Carrying out testing BASIC TEST OF AGGREGATE.Flakiness Index & Elongation Index.
Carrying out testing BASIC TEST OF AGGREGATE.Stripping Value. (for Bituminous Work)
Carrying out testing BASIC TEST OF AGGREGATE.Soundness.
Carrying out testing BASIC TEST OF FINE AGGREGATE.Fineness Modulus ( Sieve Analysis ),Silt & Clay Content
Carrying out testing BASIC TEST OF FINE AGGREGATE.Silt Factor.
Carrying out testing BASIC TEST OFBRICKS. Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks).
Carrying out testing BASIC TEST OF CERAMIC TILES / VITRIFIED TILES Water Absorption, Modulus of Rupture (Set of 6 Tiles)
Carrying out testing BASIC TEST OF CONCRETE Compressive Strength OF C.C. Cube (Set of 3 cubes).
Carrying out testing BASIC TEST OF CONCRETE Concrete Mix Design (With all Tests on basic materials) (For M-40, M-30, M-25)
Carrying out testing BASIC TEST OF CONCRETE PAVING BLOCKS Compressive Strength , Water Absorption,(Set of 8 Blocks)
Carrying out testing BASIC TEST OF SOIL / MURUM Sieve Analysis.
Carrying out testing BASIC TEST OFSOIL / MURUM Liquid limit & plastic Limit.
Carrying out testing BASIC TEST OF SOIL / MURUM Field Density by Sand replacement method.
Carrying out testing BASIC TEST OF STEEL BAR TESTING Upto 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
Carrying out testing BASIC TEST OF STEEL BAR TESTING Above 16 mm (Set of 3 Bars)(Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
Carrying out testing BASIC TEST OF MIX DESIGN.GSB Mix Design./Cement Treated Sub Base ( CTSB)
Carrying out testing BASIC TEST OF SOIL / MURUM Mechanical Analysis.
Carrying out testing BASIC TEST OF BITUMEN Penetration, Softening Point, Flash & Fire Point, Specific Gravity
Carrying out testing BASIC TEST OF BITUMEN Extraction &Sieve Analysis of Bituminous mix ( for BM/DBM/AC) (2 samples of extraction for one sieve analysis including extraction)
Carrying out testing BASIC TEST OF BITUMEN Job Mix Design with all Tests on aggregate (Excluding bitumen) for DBM/SDBC/AC/SMA (Stone Mastic Ashphalt) ( Testing of Bitumen shall be seperately Charged)
Carrying out testing BASIC TEST OF BITUMEN Viscosity.
Carrying out testing BASIC TEST OF BITUMEN Ducility / Elastic Recovery
Design, Supply, installation, testing and commissioning of High Quality LED Arena Flood light 1200W+/- 5% , Made of SIngle Piece pressure diecast Aluminium housing Single piece High Grade ADC 12 PDC Al alloy housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special cluster PC lens optics with precise distribution ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 1.5Lakhs and with system efficacy Min 125Lm/W at CRI >90, TLCI >90 suitable for best in class lighting experience for players , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver sshould be Dimmable type for control with suitable Approved Makes : Lighting Technologies/ Signify .(OUTDOOR SPORTS ARENA -Athletic Track with Football Field )
Design, Engineering, Supply, Installation, Testing and Commissioning of Sports Highmast of height 30 mtr (upto top of headframe Suitable to mount 25 No of Sports Arena Lights. High Mast structure with frame should be designed for withstanding wind speed as per Site location, The headframe designed with mounting arrangement for factory fitted Luminaire mounting with necessary mounting angles complete in all respect as per direction of Engineer in charge. as per design to Meet Lux levels as per the technical requirement . THe Highmast should have the same RAL shade of the Luminaire . Work includes construction of suitable civil foundation for the mast considering the SBC of the area Approved Makes : Valmont/ Lysaght.(OUTDOOR SPORTS ARENA -Athletic Track with Football Field )
Supply of Oudoor type Feeder Panel along with Driver drack fabricated using 14 /16 SWG MS sheet steel and powder coated. Panel board shall have neccesary foundation channels and shall be incorporated with necessary INCOMER, OUTGOING and BUS BARs, System should bemounted on the Highmast structure at bottom leavel for easy maintenance. .(OUTDOOR SPORTS ARENA -Athletic Track with Football Field )
Design, Supply Installation testing and commissioning of Main electrical Panel (Outdoor) to control 4 highmasts .(OUTDOOR SPORTS ARENA -Athletic Track with Football Field )
Design supply installation testing and commissioning of Trailing cables ( Panel/Driver to Luminaire ) and Power cables from Main panel to Mast Panels. .(OUTDOOR SPORTS ARENA -Athletic Track with Football Field )
Design, Supply, installation, testing and commissioning of High Quality LED Arena Flood light 800W+/- 5% , Made of SIngle Piece pressure diecast Aluminium housing High Grade ADC 12 PDC Al alloy housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special cluster PC lens optics with precise distribution ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 1.4Lakhs and with system efficacy Min 160Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Lighting Technologies/ Signify .(OUTDOOR SPORTS ARENA -Football )
Design, Engineering, Supply, Installation, Testing and Commissioning of Sports Highmast of height 25 mtr (upto top of headframe Suitable to mount 15 No of Sports Arena Lights. High Mast structure with frame should be designed for withstanding wind speed as per Site location, The headframe designed with mounting arrangement for factory fitted Luminaire mounting with necessary mounting angles complete in all respect as per direction of Engineer in charge. as per design to Meet Lux levels as per the technical requirement . Work includes construction of suitable civil foundation for the mast considering the SBC of the area Approved Makes : Valmont/ Lysaght (OUTDOOR SPORTS ARENA -Football )
Supply of Oudoor type Feeder Panel along with Driver drack fabricated using 14 /16 SWG MS sheet steel and powder coated. Panel board shall have neccesary foundation channels and shall be incorporated with necessary INCOMER, OUTGOING and BUS BARs, System should bemounted on the Highmast structure at bottom leavel for easy maintenance. (OUTDOOR SPORTS ARENA -Football )
Design, Supply Installation testing and commissioning of Main electrical Panel (Outdoor) to control 4 highmasts (OUTDOOR SPORTS ARENA -Football )
Design supply installation testing and commissioning of Training cables ( Panel/Driver to Luminaire ) and Power cables from Main panel to Mast Panels. (OUTDOOR SPORTS ARENA -Football )
Design, Supply, installation, testing and commissioning of High Quality LED Arena Flood light 800W+/- 5% , Made of pressure diecast Aluminium housing High Grade ADC 12 PDC Al alloy housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special cluster PC lens optics with precise distribution ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 1.28Lakhs and with system efficacy Min 160Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Lighting Technologies/ Signify .(OUTDOOR SPORTS ARENA -Hockey )
Design, Engineering, Supply, Installation, Testing and Commissioning of Sports Highmast of height 20 mtr (upto top of headframe Suitable to mount 10 No of Sports Arena Lights. High Mast structure with frame should be designed for withstanding wind speed as per Site location, The headframe designed with mounting arrangement for factory fitted Luminaire mounting with necessary mounting angles complete in all respect as per direction of Engineer in charge. as per design to Meet Lux levels as per the technical requirement .THe Highmast should have the same RAL shade of the Luminaire . Work includes construction of suitable civil foundation for the mast considering the SBC of the area Approved Makes : Valmont/ Lysaght(OUTDOOR SPORTS ARENA -Hockey )
Supply of HMLDB Oudoor type fabricated using 14 /16 SWG MS sheet steel and powder coated. Panel board shall have neccesary foundation channels and shall be incorporated with necessary INCOMER, OUTGOING and BUS BARs, System should bemounted on the Highmast structure at bottom leavel for easy maintenance. (OUTDOOR SPORTS ARENA -Hockey )
Design, Supply Installation testing and commissioning of Main electrical Panel (OUTDOOR SPORTS ARENA -Hockey )
Design supply installation testing and commissioning of Training cables ( Panel/Driver to Luminaire ) and Power cables from Main panel to Mast Panels. (OUTDOOR SPORTS ARENA -Hockey )
Design, Supply, installation, testing and commissioning of High Quality LED Arena Flood light 400W+/- 5% , Made of pressure diecast Aluminium housing High Grade ADC 12 PDC Al alloy housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special cluster PC lens optics with precise distribution ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 64K and with system efficacy Min 160Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Lighting Technologies/ Signify .(OUTDOOR SPORTS ARENA -Tennis Courts - 5 Nos)
Design, Engineering, Supply, Installation, Testing and Commissioning of Sports Pole of height 12 mtr with single side Fixed headframe suitable to Mount 400W Sports Flood light, factory fitted with necessary mounting arrangement s, Pole should be PU painted with same RAL shade as that of the Luminaire , and should have provision for Mounting necessssary Electrical DB on the Pole , Pole should be designed asper IS to withstand the wind velocity of the Location (OUTDOOR SPORTS ARENA -Tennis Courts - 5 Nos)
Design, Engineering, Supply, Installation, Testing and Commissioning of Sports Pole of height 15 mtr with single side Fixed headframe suitable to Mount 400W Sports Flood light, factory fitted with necessary mounting arrangement s, Pole should be PU painted with same RAL shade as that of the Luminaire , and should have provision for Mounting necessssary Electrical DB on the Pole , Pole should be designed asper IS to withstand the wind velocity of the Location (OUTDOOR SPORTS ARENA -Tennis Courts - 5 Nos)
Design, Supply Installation testing and commissioning of Main electrical Panel and necessary junction box at each pole level for switching. (Outdoor type) (OUTDOOR SPORTS ARENA -Tennis Courts - 5 Nos)
Design supply installation testing and commissioning of Training cables and Power cables (OUTDOOR SPORTS ARENA -Tennis Courts - 5 Nos)
Design, Supply, installation, testing and commissioning of High Quality LED Arena Flood light 400W+/- 5% , Made of pressure diecast Aluminium housing High Grade ADC 12 PDC Al alloy housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special cluster PC lens optics with precise distribution ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 64K and with system efficacy Min 160Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify .(OUTDOOR SPORTS ARENA -Basket Ball Courts - 2 Nos )
Design, Engineering, Supply, Installation, Testing and Commissioning of Sports Pole of height 12 mtr with single side Fixed headframe suitable to Mount 400W Sports Flood light, factory fitted with necessary mounting arrangement s, Pole should be PU painted with same RAL shade as that of the Luminaire , and should have provision for Mounting necessssary Electrical DB on the Pole , Pole should be designed asper IS to withstand the wind velocity of the Location (OUTDOOR SPORTS ARENA -Basket Ball Courts - 2 Nos )
Design, Supply Installation testing and commissioning of Main electrical Panel and necessary junction box at each pole level for switching. (Outdoor type) (OUTDOOR SPORTS ARENA -Basket Ball Courts - 2 Nos )
Design supply installation testing and commissioning of Training cables and Power cables (OUTDOOR SPORTS ARENA -Basket Ball Courts - 2 Nos )
Design, Supply, installation, testing and commissioning of High Quality LED Arena Flood light 400W+/- 5% , Made of pressure diecast Aluminium housing High Grade ADC 12 PDC Al alloy housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special cluster PC lens optics with precise distribution ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 64K and with system efficacy Min 160Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify .(OUTDOOR SPORTS ARENA -Kabbadi and Khokho )
Design, Engineering, Supply, Installation, Testing and Commissioning of Sports Pole of height 12 mtr with single side Fixed headframe suitable to Mount 400W Sports Flood light, factory fitted with necessary mounting arrangement s, Pole should be PU painted with same RAL shade as that of the Luminaire , and should have provision for Mounting necessssary Electrical DB on the Pole , Pole should be designed asper IS to withstand the wind velocity of the Location (OUTDOOR SPORTS ARENA -Kabbadi and Khokho )
Design, Supply Installation testing and commissioning of Main electrical Panel and necessary junction box at each pole level for switching. (Outdoor type) (OUTDOOR SPORTS ARENA -Kabbadi and Khokho )
Design supply installation testing and commissioning of Training cables and Power cables (OUTDOOR SPORTS ARENA -Kabbadi and Khokho )
Design, Supply, installation, testing and commissioning of High Quality LED Arena Flood light 800W+/- 5% , Made of pressure diecast Aluminium housing High Grade ADC 12 PDC Al alloy housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special cluster PC lens optics with precise distribution ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 1.28Lakhs and with system efficacy Min 160Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify . (OUTDOOR SPORTS ARENA -Soft Ball)
Design, Engineering, Supply, Installation, Testing and Commissioning of Sports Highmast of height 20 mtr (upto top of headframe Suitable to mount 10 No of Sports Arena Lights. High Mast structure with frame should be designed for withstanding wind speed as per Site location, The headframe designed with mounting arrangement for factory fitted Luminaire mounting with necessary mounting angles complete in all respect as per direction of Engineer in charge. as per design to Meet Lux levels as per the technical requirement .THe Highmast should have the same RAL shade of the Luminaire . Work includes construction of suitable civil foundation for the mast considering the SBC of the area Approved Makes : Valmont/ Lysaght (OUTDOOR SPORTS ARENA -Soft Ball)
Supply of HMLDB Oudoor type fabricated using 14 /16 SWG MS sheet steel and powder coated. Panel board shall have neccesary foundation channels and shall be incorporated with necessary INCOMER, OUTGOING and BUS BARs, System should bemounted on the Highmast structure at bottom leavel for easy maintenance. (OUTDOOR SPORTS ARENA -Soft Ball)
Design, Supply Installation testing and commissioning of Main electrical Panel (OUTDOOR SPORTS ARENA -Soft Ball)
Design supply installation testing and commissioning of Training cables ( Panel/Driver to Luminaire ) and Power cables from Main panel to Mast Panels. (OUTDOOR SPORTS ARENA -Soft Ball)
Supply Installation testing and commissioning of Centralised cum localised Command control based Lighting control system for switching and Dimming of Each indoor sports arena separately for different light levels and monitoring of each luminaire (Like Power consumption, On/Off Condition, Dimming levels) . The system included, SITC of necessary connectivity from central control room to each sports arena. The sytem should be simple and can be operated by a normal technican . The system should be able to create Lighting scenes for each area suitable for different class of Events to enable power savings during operation.(OUTDOOR SPORTS ARENA -Outdoor Lighting Control System)
Design, Supply, installation, testing and commissioning of High Quality LED Arena Flood light 400W+/- 5% , Made of pressure diecast Aluminium housing High Grade ADC 12 PDC Al alloy housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special cluster PC lens optics with precise distribution ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 64K and with system efficacy Min 160Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify .(INDOOR SPORTS ARENA -Swimming Pool and Diving Pool )
Supply installation testing and commissioning of Necessary eelctrical system for Arena Lighting including necessary point wiring, electrical DBs for functionality of the Lighting system with controls (INDOOR SPORTS ARENA -Swimming Pool and Diving Pool )
Design, Supply, installation, testing and commissioning of High Quality LED Luminaire 80 W +/-5% , Made of Aluminium housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special Diffused PC cover ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 12K and with system efficacy Min 150Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify .(INDOOR SPORTS ARENA -Judo & Wrestling )
Supply installation testing and commissioning of Necessary eelctrical system for Arena Lighting including necessary point wiring, electrical DBs for functionality of the Lighting system with controls (INDOOR SPORTS ARENA -Judo & Wrestling )
Design, Supply, installation, testing and commissioning of High Quality LED Arena Flood light 400W+/- 5% , Made of pressure diecast Aluminium housing High Grade ADC 12 PDC Al alloy housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special cluster PC lens optics with precise distribution ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 64K and with system efficacy Min 160Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify . (INDOOR SPORTS ARENA -Boxing )
Supply installation testing and commissioning of Necessary eelctrical system for Arena Lighting including necessary point wiring, electrical DBs for functionality of the Lighting system with controls (INDOOR SPORTS ARENA -Boxing )
Design, Supply, installation, testing and commissioning of High Quality LED Luminaire 80 W +/-5% , Made of Aluminium housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special Diffused PC cover ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 12K and with system efficacy Min 150Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify .(INDOOR SPORTS ARENA -Fencing )
Supply installation testing and commissioning of Necessary eelctrical system for Arena Lighting including necessary point wiring, electrical DBs for functionality of the Lighting system with controls (INDOOR SPORTS ARENA -Fencing )
Design, Supply, installation, testing and commissioning of High Quality LED Luminaire 80 W +/-5% , Made of Aluminium housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special Diffused PC cover ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 12K and with system efficacy Min 150Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify .(INDOOR SPORTS ARENA -Squash )
Supply installation testing and commissioning of Necessary eelctrical system for Arena Lighting including necessary point wiring, electrical DBs for functionality of the Lighting system with controls (INDOOR SPORTS ARENA -Squash )
Design, Supply, installation, testing and commissioning of High Quality LED Luminaire 80 W +/-5% , Made of Aluminium housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special Diffused PC cover ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 12K and with system efficacy Min 150Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify .(INDOOR SPORTS ARENA -Table Tennis )
Supply installation testing and commissioning of Necessary eelctrical system for Arena Lighting including necessary point wiring, electrical DBs for functionality of the Lighting system with controls (INDOOR SPORTS ARENA -Table Tennis )
Design, Supply, installation, testing and commissioning of High Quality LED Luminaire 80 W +/-5% , Made of Aluminium housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special Diffused PC cover ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 12K and with system efficacy Min 150Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify .(INDOOR SPORTS ARENA -Weight Lifting )
Supply installation testing and commissioning of Necessary eelctrical system for Arena Lighting including necessary point wiring, electrical DBs for functionality of the Lighting system with controls (INDOOR SPORTS ARENA -Weight Lifting )
Design, Supply, installation, testing and commissioning of High Quality LED Luminaire 80 W +/-5% , Made of Aluminium housing with extended heat sink eanabling Passive Cooling & offering a totally silent, robust, heat transfer , Injection moulded special Diffused PC cover ensuring low glare & best in class uniformity , THe Luminaire should have Nominal Lumen package of >/= 12K and with system efficacy Min 150Lm/W , The Luminaire should be controlled with a remote high efficient IP67 single Flicker free Driver with operating Voltage: 90-305V AC , with Mis Wiring , Short Circuit , Over Voltage & Under Voltage , Thermal Protections ,Open Circuit & Output failure protections, Luminaire should be equiped with Inbuilt Surge Protection: >=6KV L-L & 10kV L-E , and 20KV,10KA External SPD. THe Driver should be Dimmable type for control with suitable Approved Makes : Thorn/ Gigatera / Lighting Technologies/ Signify .(INDOOR SPORTS ARENA -Gymnastics & Sepak Takraw )
Supply installation testing and commissioning of Necessary eelctrical system for Arena Lighting including necessary point wiring, electrical DBs for functionality of the Lighting system with controls (INDOOR SPORTS ARENA -Gymnastics & Sepak Takraw )
Supply Installation testing and commissioning of Centralised cum localised Command control based Lighting control system for switching and Dimming of Each indoor sports arena separately for different light levels and monitoring of each luminaire (Like Power consumption, On/Off Condition, Dimming levels) . The system included, SITC of necessary connectivity from central control room to each sports arena. The sytem should be simple and can be operated by a normal technican . The system should be able to create Lighting scenes for each area suitable for different class of Events to enable power savings during operation.(Indoor Lighting Control system )
Design, Supply and Installation Module MONOPERC HALF CUT MODULES 144 Cells | 550 Wp or higher, MBB Technology , M10- 25 years warranty of 85% power output.- 12 years manufacturers warranty. module specification must be as per MNRE guidelines.(1950 kw Solar plant)
Design, Supply and Installation On grid phase Inverter Power Conditioners / Inverters including MPPT (EN 50530) and Protections shall comply Efficiency Measurements as per IEC 61683 / IS 61683 and Environmental Testing as per IEC 60068-2 (1, 2, 14, 30) /Equivalent BIS Std. Surge protection shall be provided on the DC side and the AC side of the solar system. The DC surge protection devices (SPDs) shall be installed in the DC distribution box adjacent to the solar grid-tie inverter .In case if the Charge controller is in-built in the inverter, no separate IEC 62093 test is required. Additionally the inverters shall conform to the relevant national / international Electrical Safety Standards wherever applicable as per IEC 62109-1, IEC 62109-2 and anti-islanding protection as per VDE 0126- 1-1, IEC 60255.5 / IEC 60255.27 / IEC 62116 Yrs (1950 kw Solar plant)
Design, Supply and Installation Structure Standard for 1. RCC Mounting Systems, hot dip galvanized MS profiles as per IS 4759 for flat RCC ,bolts, nuts, shims and other hardware shall be SS 304 , 2.In case of rooftop systems using aluminium structure, mounting structure components including T slotted rails, End and mid clamps, angle brackets, and T nuts & bolts should all be made out of anodized Aluminium. The rails riveted to metal rooftop structures shall be done with pop rivets.(1950 kw Solar plant)
Design, Supply and Installation DC Cable -Cable Description: 6 sqmm Annealed tinned flexible aluminium conductor EBXL, XLP solar cable (1950 kw Solar plant)
Design, Supply and Installation AC cable Cable Description: 1100 V AC, PVC insulated confirming IEC 60189/ IS 1554 & IEC 60502-1 with Aluminum conductor according to IEC 60228. AC cables of size 4mm2 and below shall be electrolyte tinned copper conductor type confirming the relevant IS/IEC(1950 kw Solar plant)
AC Distribution Board AC Distribution Board (ACDB) shall control the AC power from PCU /inverter, and should have necessary surge arrestors. Interconnection from ACDB to mains at LT Bus bar while in grid tied mode. All switches and the circuit breakers, connectors should confirm to IEC 60947, part I, II and III or EN 50521 standards.(1950 kw Solar plant)
Design, Supply and Installation DC Combiner Box shall be used to combine the DC cables of the solar module arrays with DC fuse protection for the outgoing DC cable(s) to the DC Distribution Box. DC disconnect switch should be as per IEC 60947-3, DC fuse ratingconform to IEC 60269-1, 2, 6. DC disconnect switch provide safety and protection against over currentsin any DC voltage photovoltaic applications and PV solar modular. DC fuse protects against reverse currents in dedicated to PV application. (1950 kw Solar plant)
Design, Supply and Installation Earthing Electrode Electrode shall be made of GI pipe having a clean surface and not covered with paint, enamel or poorly conducting material. Galvanized pipe shall not be smaller than 38 mm ID. Earthing strip 25*3 mm Ht dipp galvanised Iron as per the details 81 indicated in IS : 3043/87 Electrodes shall be embedded below permanentmoisture level. (1950 kw Solar plant)
Design, Supply and Installation Lighting Arrestor The SPV Power Plant should be provided with lightening and over voltage protection. . The Lighting Arrestor (LA) is to be made of 1 ¼” diameter (minimum) and 12 feetlong GI spike on the basis of the necessary meteorological data of the location ofthe projects. Necessary foundation for holding the LA is to be arranged keeping in view the wind speed of the site and flexibility in maintenance in future. Latest grounding equipment should be used for this purpose. Each LA shall have to be earthed through suitable size earth bus with earth pits. The earthing pit shall have to be made as per IS 3043. (1950 kw Solar plant)
Design, Supply and Installation Remote Monitoring system and weather monitoring system The plant parameters shall be measured by using SCADA or Equivalent system to monitor, maintain, and control the plan, and also to study the plant performance. The system should meet IEC 61724 standard for this provision. The plant monitoring parameter shall include. • PV array energy production: Digital Energy Meters to log the actual of AC /DC Voltage, Current & Energy generated by the PV system shall have to be provided. • Solar Irradiance cum weather station: An integrating Pyranometer (Class II or better) cum weather station of IP65 /67 shall be provided, with the sensors mounted in the plane of the array, those parameters are associated with solar PV plants. Readout shall be integrated with data logging, system. • Temperature: Temperature probes for recording the Solar panel temperature and ambient temperature shall be provided.(1950 kw Solar plant)
Design, Supply and Installation DG PV Synchroniser system with zero export if runs on(1950 kw Solar plant)
Design, Supply and Installation Fire extinguisher along with buckets and sand(1950 kw Solar plant)
Design, Supply and Installation Module Cleaning System - Fully automatic module cleaning system with nozzle sprey , water pump,control unit ,communication (1950 kw Solar plant)
Design, Supply and Installation Communication Cable Control & Data Communication Cables: The cable shall be 1.1kV grades, heavy duty, stranded copper conductor, PVC type A insulated, armoured galvanized steel wire / strip armored, flame retardant low smoke (FRLS) extruded PVC type ST-1 outer sheathed. The cable shall, in general conform to IS-1554 Part-I & other relevant standards(1950 kw Solar plant)
Design, Supply and Installation Metering Arrangement 1. A Roof Top Solar (RTS) Photo Voltaic (PV) system shall consist of following energy meters: i. Net meter: To record import and export units ii. Generation meter: To keep record for total generation of the plant. 2. The installation of meters wherever applicable, shall be carried out by the MSEDCL as ditions and procedures laid down by the concerned MERC/MSEDCL. However, the installation of CTs & PTs, wherever applicable, can be carried out by theEmpanelled Vendor as per the terms, conditions and procedures laid down by the concerned MERC/MSEDCL. (1950 kw Solar plant)
S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FMC
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FFPA/AFR
Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification No. FFPA/ SOC
Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC
Supplying & erecting, stand for microphone. (Similar to AHUJA make model DGN)
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.
S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FMC
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FFPA/AFR
Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification No. FFPA/ SOC
Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC
Supplying & erecting, stand for microphone. (Similar to AHUJA make model DGN)
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.
S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, installation, testing and commissioning of booster fire pump [BP]suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter , phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FMC
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FFPA/AFR
Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification No. FFPA/ SOC
Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC
Supplying & erecting, stand for microphone. (Similar to AHUJA make model DGN)
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying and erecting Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 Kg capacity cartridge type con. to IS: 15683 complete erected with necessary clamp made from 50 mm x 6 mm M.S.flat with nut and bolts grouted in wall complete.
Providing floor mounting stand for keeping 4 Nos. of Fire Buckets 1500 mm in length, 900 mm in height frame made out of 30x30x4 mm. angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Providing round bottom Fire bucket of 9 Litres capacity as per IS: 2546 made out of 24 guage G.I. sheet with extra handle at bottom duly painted white inside and red outside with Fire mark , on provided stand/wall hook .
Supplying and installing G.I. pipe above ground of C class ERW of size 150 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 100 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 80 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 65 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 50 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 40 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 32 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 25 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing cast iron double flange Butterfly Valve of size 150 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 100 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 50 mm dia as per specification no. FF-VL/BFV
Supplying and erecting stainless steel Single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying SS Branch Pipes of 63 mm dia. fitted with 20 mm dia detachable hexagonal multipurpose nozzle as per specification FF-FFA/NEW
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Hydrant valve, hose pipe and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting 25 mm dia GM Air Release Cock with necessary GI coupling to be fitted on top of air vessel or on wet riser as per specification FF-FFA/ARV.
Supplying and installing wall mounted swinging Hose Reel Drum fitted with 19 mm dia 30 mtr long high pressure polypropylene (polyhose) pipe fitted with necessary accessories complete as per specification no. FF-FFA/HRD
Supplying and erecting one no. Brass orifice plate having 6 mm thickness, 140 mm outer dia at every single outlet hydrant valve as per specification No. FF-FFA/OP
Supplying & laying (including excavation) 25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Supplying and installing gun metal gate valve of size 25 mm dia as per specification no. FF-VL/GV.
Supplying and erecting 15 mm (½") dia. NBCM Body chrome finished (pendent / Upright type) quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction as per specification No. FF-SPR
Supply, Installation, testing & commissioning of Installation control (Alarm) valve of cast iron body and brass/ bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box ball valves, MS pipe of reqd. size, flanges, orifice plate, gasket etc. of size 150 mm dia as reqd.
Supply, Installation, testing & commissioning of flow switches in 80/100/150 mm dia pipe with all accessories as required
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supply, Installation, testing & commissioning of Intelligent Analogue Addressable optical Beam smoke Detector including Transmitter-receiver and reflector with 100 meter range complete with all fixing accessories on wall / suspended from ceiling including mounting bracket, clamps and installation screws etc to be installed under roof interconnecting to loop cable complete as required as per specifications.
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FFPA/AFR
Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification No. FFPA/ SOC
Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC
Supplying & erecting, stand for microphone. (Similar to AHUJA make model DGN)
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.(PAVILIAN BLOCK J & K )
S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FMC
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FFPA/AFR
Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification No. FFPA/ SOC
Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC
Supplying & erecting, stand for microphone. (Similar to AHUJA make model DGN)
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying and erecting Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 Kg capacity cartridge type con. to IS: 15683 complete erected with necessary clamp made from 50 mm x 6 mm M.S.flat with nut and bolts grouted in wall complete.
Providing floor mounting stand for keeping 4 Nos. of Fire Buckets 1500 mm in length, 900 mm in height frame made out of 30x30x4 mm. angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Providing round bottom Fire bucket of 9 Litres capacity as per IS: 2546 made out of 24 guage G.I. sheet with extra handle at bottom duly painted white inside and red outside with Fire mark , on provided stand/wall hook .
Supplying and installing G.I. pipe above ground of C class ERW of size 150 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 100 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 80 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 65 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 50 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 40 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 32 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 25 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing cast iron double flange Butterfly Valve of size 150 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 100 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 50 mm dia as per specification no. FF-VL/BFV
Supplying and erecting stainless steel Single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying SS Branch Pipes of 63 mm dia. fitted with 20 mm dia detachable hexagonal multipurpose nozzle as per specification FF-FFA/NEW
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Hydrant valve, hose pipe and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting 25 mm dia GM Air Release Cock with necessary GI coupling to be fitted on top of air vessel or on wet riser as per specification FF-FFA/ARV.
Supplying and installing wall mounted swinging Hose Reel Drum fitted with 19 mm dia 30 mtr long high pressure polypropylene (polyhose) pipe fitted with necessary accessories complete as per specification no. FF-FFA/HRD
Supplying and erecting one no. Brass orifice plate having 6 mm thickness, 140 mm outer dia at every single outlet hydrant valve as per specification No. FF-FFA/OP
Supplying and installing gun metal gate valve of size 25 mm dia as per specification no. FF-VL/GV.
Supplying and erecting 15 mm (½") dia. NBCM Body chrome finished (pendent / Upright type) quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction as per specification No. FF-SPR
Supply, Installation, testing & commissioning of Installation control (Alarm) valve of cast iron body and brass/ bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box ball valves, MS pipe of reqd. size, flanges, orifice plate, gasket etc. of size 150 mm dia as reqd.
Supply, Installation, testing & commissioning of flow switches in 80/100/150 mm dia pipe with all accessories as required
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FFPA/AFR
Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification No. FFPA/ SOC
Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC
Supplying & erecting, stand for microphone. (Similar to AHUJA make model DGN)
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying and erecting Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 Kg capacity cartridge type con. to IS: 15683 complete erected with necessary clamp made from 50 mm x 6 mm M.S.flat with nut and bolts grouted in wall complete.
Providing floor mounting stand for keeping 4 Nos. of Fire Buckets 1500 mm in length, 900 mm in height frame made out of 30x30x4 mm. angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Providing round bottom Fire bucket of 9 Litres capacity as per IS: 2546 made out of 24 guage G.I. sheet with extra handle at bottom duly painted white inside and red outside with Fire mark , on provided stand/wall hook .
Supplying and installing G.I. pipe above ground of C class ERW of size 150 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 100 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 80 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 65 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 50 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 40 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 32 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 25 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing cast iron double flange Butterfly Valve of size 150 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 100 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 50 mm dia as per specification no. FF-VL/BFV
Supplying and erecting stainless steel Single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying SS Branch Pipes of 63 mm dia. fitted with 20 mm dia detachable hexagonal multipurpose nozzle as per specification FF-FFA/NEW
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Hydrant valve, hose pipe and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting 25 mm dia GM Air Release Cock with necessary GI coupling to be fitted on top of air vessel or on wet riser as per specification FF-FFA/ARV.
Supplying and installing wall mounted swinging Hose Reel Drum fitted with 19 mm dia 30 mtr long high pressure polypropylene (polyhose) pipe fitted with necessary accessories complete as per specification no. FF-FFA/HRD
Supplying and erecting one no. Brass orifice plate having 6 mm thickness, 140 mm outer dia at every single outlet hydrant valve as per specification No. FF-FFA/OP
Supplying and installing gun metal gate valve of size 25 mm dia as per specification no. FF-VL/GV.
Supplying and erecting 15 mm (½") dia. NBCM Body chrome finished (pendent / Upright type) quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction as per specification No. FF-SPR
Supply, Installation, testing & commissioning of Installation control (Alarm) valve of cast iron body and brass/ bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box ball valves, MS pipe of reqd. size, flanges, orifice plate, gasket etc. of size 150 mm dia as reqd.
Supply, Installation, testing & commissioning of flow switches in 80/100/150 mm dia pipe with all accessories as required
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FFPA/AFR
Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification No. FFPA/ SOC
Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC
Supplying & erecting, stand for microphone. (Similar to AHUJA make model DGN)
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete.
Supplying, installation, testing and commissioning of main fire pump(MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 75kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
Supplying, erecting & terminating XLPE armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 2 core 1.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting PVC armoured cable 12 core 1.5 sq mm Cu conductor with continuous G.I. earth wire complete erected with glands and lugs, on wall or laid in provided trench/ pipe /cable trey as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and installing G.I. pipe above ground of C class ERW of size 250 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 200 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 150 mm dia with with necessary fittings as per specification no. FF-PP
Providing coating of Bitumen Paint & 4mm thick Wrapping as per IS 10221 for underground 150 mm Ring Main of Fire Fighting System.
Excavating soft Murum/Soil roadby chiseling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good.
Supplying and installing G.I. pipe above ground of C class ERW of size 80 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and erecting cast iron double flange NRV of size 200 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 50 mm dia complete as per specification no. FF-VL/NRV
Supplying and installing cast iron double flange Butterfly Valve of size 150 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 100 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 50 mm dia as per specification no. FF-VL/BFV
Supplying and erecting stainless steel Single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying SS Branch Pipes of 63 mm dia. fitted with 20 mm dia detachable hexagonal multipurpose nozzle as per specification FF-FFA/NEW
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Hydrant valve, hose pipe and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and installing Air Vessel of 300 mm dia 1.5 mtr in height M.S. tank installed inside pump house as per specification no. FF-FFA/ACT.
Supplying and installing Fire Brigade Header of 150 mm dia, for supplying water in fire tank as per specification no. FF-FFA/FBC
Supplying and installing Fire Brigade Header (Siamese Connection) of 150 mm dia, supplying water to wet riser system as per specification no. FF-FFA/SMC
Supplying and erecting 200 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 75/80 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting one no. Brass orifice plate having 6 mm thickness, 140 mm outer dia at every single outlet hydrant valve as per specification No. FF-FFA/OP
Supplying & laying (including excavation) 25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Supplying and erecting cast iron double flange sluice valve 200 mm dia. complete as per specification no. FF-VL/SV
Supplying and installing Cast iron double flange Sluice valve 80 mm dia as per specification
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.
S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FMC
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FFPA/AFR
Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification No. FFPA/ SOC
Supplying, erecting, testing and commissioning microphone as per specification No. FF-PA/MIC
Supplying & erecting, stand for microphone. (Similar to AHUJA make model DGN)
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete.
Supplying, installation, testing and commissioning of main fire pump(MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 75kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
Supplying, erecting & terminating XLPE armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 2 core 1.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting PVC armoured cable 12 core 1.5 sq mm Cu conductor with continuous G.I. earth wire complete erected with glands and lugs, on wall or laid in provided trench/ pipe /cable trey as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and installing G.I. pipe above ground of C class ERW of size 250 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 200 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 150 mm dia with with necessary fittings as per specification no. FF-PP
Providing coating of Bitumen Paint & 4mm thick Wrapping as per IS 10221 for underground 150 mm Ring Main of Fire Fighting System.
Excavating soft Murum/Soil roadby chiseling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good.
Supplying and installing G.I. pipe above ground of C class ERW of size 80 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and erecting cast iron double flange NRV of size 200 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 50 mm dia complete as per specification no. FF-VL/NRV
Supplying and installing cast iron double flange Butterfly Valve of size 150 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 100 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 50 mm dia as per specification no. FF-VL/BFV
Supplying and erecting stainless steel Single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying SS Branch Pipes of 63 mm dia. fitted with 20 mm dia detachable hexagonal multipurpose nozzle as per specification FF-FFA/NEW
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Hydrant valve, hose pipe and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and installing Air Vessel of 300 mm dia 1.5 mtr in height M.S. tank installed inside pump house as per specification no. FF-FFA/ACT.
Supplying and installing Fire Brigade Header of 150 mm dia, for supplying water in fire tank as per specification no. FF-FFA/FBC
Supplying and installing Fire Brigade Header (Siamese Connection) of 150 mm dia, supplying water to wet riser system as per specification no. FF-FFA/SMC
Supplying and erecting 200 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 75/80 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting one no. Brass orifice plate having 6 mm thickness, 140 mm outer dia at every single outlet hydrant valve as per specification No. FF-FFA/OP
Supplying & laying (including excavation) 25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Supplying and erecting cast iron double flange sluice valve 200 mm dia. complete as per specification no. FF-VL/SV
Supplying and installing Cast iron double flange Sluice valve 80 mm dia as per specification
Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 6 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 4 nos. feeder with 4 VCB compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA
Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by Power Supply Agency / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 2000 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound ,without gas cushioning ,hermetically Sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%,having 7 number of tap positions with standard accessories complete with test certificate with losses below 1510 Watts at 50% load, 4300 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL.
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
Making trench in hard murum/Tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.).
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 380/400 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 65.5 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 450 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG (For Fire Fighting Pumps Panels )
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for Diesel Generating Set of above 320 kVA up to 400 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG (Hostel Building)
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 400 kVA up to 500 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Supplying, erecting, testing and commissioning of Microprocessor based Generator Control Unit (Synchronization panel) panel suitable for diesel generating set of above 400 kVA up to 500 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features and safeties etc as per specification no. GEN-SYNC.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 250 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 42.30 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 425 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG (For Sport Club,Convention Centre,Spert School,Spoert University)
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 200 kVA up to 250 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Supplying, erecting, testing and commissioning of Microprocessor based Generator Control Unit (Synchronization panel) panel suitable for diesel generating set of 320 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features and safeties etc as per specification no. GEN-SYNC.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 125 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 21.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 230 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 100 kVA up to 125 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Supplying, installing, testing and commissioning FR, XLPE armoured cable 4core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE armoured cable 3½core 240 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE armoured cable 3½core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 Kv
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer. Design,fabrication,assembling,supply,installation,testing and commissioning of cubicle type LT panels suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick,entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable ,cable alleys ,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels
PCC Panel MAIN PANEL (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD INCOMER: 3 No - 3200A FP MP based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 50 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. E/I interlock with eachother. 1 No - 400A FP MP based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 50 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. interlock BUSCOUPLER 03 nos : 3200A FP MP based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 50 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUSBAR: 3200A, 50kA FP Aluminium Busbar with heat shrinkable Sleeves. OUTGOING: (36kA Ics=Icu=100% upto 433V) with on/off/trip indication lamps & multifunction meter 3 No : 2000 Amps 4P MCCB, 50kA with E/F protection 1 No : 1600 Amps 4P MCCB, 50kA with E/F protection 2 No : 1250 Amps 4P MCCB, 50kA with E/F protection 6 No : 800 Amps 4P MP MCCB, 50kA with E/F protection 2 No : 630 Amps 4P MP MCCB , 50kA with E/F protection 4 No : 400 Amps 4P MP MCCB, 50kA with E/F protection 2 No : 250 Amps 4P MP MCCB, 50kA with E/F protection 4No : 63 Amps 4P MP MCCB, 50kA with E/F protection
APFC PANEL (800 KVAR)Supplying and erecting 800 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.
Design,fabrication,assembling,supply,installation,testing and commissioning of cubicle type LT panels suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick,entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable ,cable alleys ,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels
Main LT Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1600A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA, (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB Note:- 1) For electrical drawout type ACB for item no from 5-8-5 to 5-8-8 increase rates by 15%
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 630A up to 800A MCCB
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1000A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close indication, individual fault trip indication, indications for alarm and trip, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB Note:- 1) For electrical drawout type ACB for item no from 5-8-5 to 5-8-8 increase rates by 15%
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 630A up to 800A MCCB
HVAC Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1000A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close indication, individual fault trip indication, indications for alarm and trip, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB Note:- 1) For electrical drawout type ACB for item no from 5-8-5 to 5-8-8 increase rates by 15%
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 630A up to 800A MCCB
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type)
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
SITC of Electric Traction Passenger Lift with · Rated capacity :-16 Passenger/408Kg · Floors :- G+2 floor (3 Stops/ 3 Landings) · Travel :- 9 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 1000 mm wide x 2000 mm high · Clear Car size of 2300 mm wide x 2300 mm deep x 2250mm high · Lift shaft available having clear size of 2070 mm wide x 2880 mm deep, +/- 1500 mm Pit depth, 4000 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.
· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Full Collective control system, add as below. For Lift travelling above First floor & up to Eighth floor
For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting CRCA powder coated corridor / passage light LED fitting (4 feet) Max. 50W with high transitivity diffuser with system lumens output of Min. 6000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 800A Capacity at 400C ambient temperature Sandwich type Aluminium Conductor tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection,42/50KA short circuit rating for 1sec, Insulation Class F (155 C) , casing made of minimum 1.5mm hot / electro Galvanized /Epoxy powder coated steel sheet enclosure with required shade of paint having Mechanical strength certification up to IK10 overall cross sectional area not more than 0.0170 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories as per site requirement with Horizontal / Vertical G.I. Support at required interval with Double run External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specification
Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for 800A 3 phase 4 wire 415V, 50 Hz A.C ,42/50kA short circuit rating for 1 sec Sandwich type Aluminium BBT with necessary accessories complete confirming to IEC 61439-6 as per specification
Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 32A to 125A 3 phase 4 wire 415V, 50Hz AC Supply made with High Grade Plastic enclosure with provision of MCB/ MCCB without (MCB/MCCB) complete as required confirming to IEC 61439-6 as per specification
Supplying, installing & Commissioning Vertical or Horizontal 90 Degree Elbow for Sandwich type Aluminium Compact bus trunking/ rising mains Suitable for 800A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,42/50KA short circuit rating for 1sec Made of minimum 1.5mm Thick Galvanised sheet metal enclosure (IP54/55) duly powder coated with all necessary accessories complete confirming to IEC 61439-6 as per specification Design,fabrication,assembling,supply,installation,testing and commissioning of cubicle type LT panels suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick,entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable ,cable alleys ,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels
MAIN PANEL (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD INCOMER: 2 No - 1600A FP MP based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 36KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. interlock with each other BUS COUPLER: 1 No- 1600A,FP, MP 36kA MCCB WITH O/C, S/C, E/F WITH RS 485 PORT (BUS COUPLER) (Ics=Icu=100% upto 415 V) with R-Y-B BUSBAR: 800A, 36kA TPN Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: (36kA Ics=Icu=100% upto 433V) with on/off/trip indication lamps & multifunction meter 2 No : 800 Amps 4P TM MCCB, 36kA with E/F protection 2 No : 250 Amps 4P TM MCCB, 25kA with E/F protection 2 No : 125 Amps 4P TM MCCB, 25kA with E/F protection 5 No : 63 Amps 4P TM MCCB, 25kA with E/F protection
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW RCCB/RCCB
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/65Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting integrated LED Highbay Fitting 135W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 20000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.Design,fabrication,assembling,supply,installation,testing and commissioning of cubicle type LT panels suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick,entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable ,cable alleys ,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels
Main LT Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, up to 800A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s),with standard accessories and with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off- Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB Note:- 1) For electrical drawout type ACB for item no from 5-8-5 to 5-8-8 increase rates by 15%
Providing & erecting 4 Pole MCCB, 415 V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 630A up to 800A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB.
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Providing & erecting 4 Pole MCCB, 415 V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB.
HVAC Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 4 Pole MCCB, 415 V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 630A up to 800A MCCB.
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)
Supplying & erecting triple pole and neutral distribution board (TPNDB),\ SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 20 Passenger/1360Kg · Floors :- G+1 floor (2 Stops/ 2 Landings) · Travel :- 21 to 29.4 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.5mps VS · Car/Landing door clear opening of 1000 mm wide x 2000 mm high · Clear Car size of 2600 mm wide x 2100 mm deep x 2250mm high · Lift shaft available having clear size of 2220 mm wide x 3350 mm deep, +/- 1500 mm Pit depth, 4000 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.
· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Full Collective control system, add as below. For Lift travelling above First floor & up to Eighth floor
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 Kv
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 250A Capacity at 40oC ambient temperature Air Insulated type Bus Trunking Aluminium Conductor having purity not less than 99.6% with Tin plated at joints suitable for (3L+N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54 Protection, 25KA short circuit rating for 0.1sec, Insulation Class F (155 C), casing made of Galvanized/powder coated steel sheet enclosure having Mechanical strength certification up to IK10 with required shade of paint & having cross sectional area not more than 0.0150 Sq m, complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with , outlet cover , plug in hole as per site requirement with Horizontal / Vertical G.I. Support at required interval, External Single Run 25x10mm Aluminium earthing strip or Internal Integral Earth confirming to IEC 61439-6 as per specification
Supplying, installation, testing and commissioning of Flange end as per design requirement & site condition suitable for Aluminium 250A, 3 phase 4 wire 415V, 50 Hz A.C ,25kA short circuit rating for 0.1 sec for Air Insulated type BBT. With necessary accessories complete confirming to IEC 61439-6 as per specification
Supplying, installing & Commissioning Vertical or Horizontal 90 Degree/Tee Elbow for Air Insulated type bus trunking/ rising mains of capacity 250A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,,25kA short circuit rating for 1 sec Made Galvanised sheet metal enclosure (IP54) duly powder coated with all necessary accessories complete confirming to IEC 61439-6 as per specification.
Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 32A to 125A 3 phase 4 wire 415V, 50Hz AC Supply made with High Grade Plastic enclosure with provision of MCB/ MCCB without (MCB/MCCB) complete as required confirming to IEC 61439-6 as per specification
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 8 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW RCCB/RCCB
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking 4 pole isolator only switch version of miniature circuit breakers of 40A in provided distribution board.
Supplying, erecting and marking 4 pole isolator only switch version of miniature circuit breakers of 63A in provided distribution board.
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG PW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/65Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 16 Passenger/884Kg · Floors :- G+5 floor (6 Stops/6 Landings) · Travel :- 20 to 24 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.5mps VS · Car/Landing door clear opening of 1000 mm wide x 2000 mm high · Clear Car size of 2600 mm wide x 1900 mm deep x 2250mm high · Lift shaft available having clear size of 2000 mm wide x 2500 mm deep, +/- 1500 mm Pit depth, 4000 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.
· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Full Collective control system, add as below. For Lift travelling above First floor & up to Eighth floor
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 Kv
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 250A Capacity at 40oC ambient temperature Air Insulated type Bus Trunking Aluminium Conductor having purity not less than 99.6% with Tin plated at joints suitable for (3L+N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54 Protection, 25KA short circuit rating for 0.1sec, Insulation Class F (155 C), casing made of Galvanized/powder coated steel sheet enclosure having Mechanical strength certification up to IK10 with required shade of paint & having cross sectional area not more than 0.0150 Sq m, complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with , outlet cover , plug in hole as per site requirement with Horizontal / Vertical G.I. Support at required interval, External Single Run 25x10mm Aluminium earthing strip or Internal Integral Earth confirming to IEC 61439-6 as per specification
Supplying, installation, testing and commissioning of Flange end as per design requirement & site condition suitable for Aluminium 250A, 3 phase 4 wire 415V, 50 Hz A.C ,25kA short circuit rating for 0.1 sec for Air Insulated type BBT. With necessary accessories complete confirming to IEC 61439-6 as per specification
Supplying, installing & Commissioning Vertical or Horizontal 90 Degree/Tee Elbow for Air Insulated type bus trunking/ rising mains of capacity 250A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,,25kA short circuit rating for 1 sec Made Galvanised sheet metal enclosure (IP54) duly powder coated with all necessary accessories complete confirming to IEC 61439-6 as per specification.
Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 32A to 125A 3 phase 4 wire 415V, 50Hz AC Supply made with High Grade Plastic enclosure with provision of MCB/ MCCB without (MCB/MCCB) complete as required confirming to IEC 61439-6 as per specification Design, Fabrication, Assembling, Supply, Installation, Testing and Commissioning of cubicle type LT panels suitable for 415 V 3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers, 3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity, DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick, entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs, solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable, cable alleys, cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels: MAIN PANEL (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD INCOMER: 2 No - 800A FP MP based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 36KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUS COUPLER: 1 No- 800A,FP, MP 36kA MCCB WITH O/C, S/C, E/F WITH RS 485 PORT (BUS COUPLER) (Ics=Icu=100% upto 415 V) with R-Y-B BUSBAR: 800A, 36kA TPN Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: (36kA Ics=Icu=100% upto 433V) with on/off/trip indication lamps & multifunction meter 1 No : 400 Amps 4P TM MCCB, 36kA with E/F protection 2 No : 250 Amps 4P TM MCCB, 25kA with E/F protection 2 No : 80 Amps 4P TM MCCB, 25kA with E/F protection 5 No : 63 Amps 4P TM MCCB, 25kA with E/F protection
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 8 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW RCCB/RCCB
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking 4 pole isolator only switch version of miniature circuit breakers of 40A in provided distribution board.
Supplying, erecting and marking 4 pole isolator only switch version of miniature circuit breakers of 63A in provided distribution board.
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG PW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/65Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 16 Passenger/884Kg · Floors :- G+5 floor (6 Stops/6 Landings) · Travel :- 20 to 24 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.5mps VS · Car/Landing door clear opening of 1000 mm wide x 2000 mm high · Clear Car size of 2600 mm wide x 1900 mm deep x 2250mm high · Lift shaft available having clear size of 2000 mm wide x 2500 mm deep, +/- 1500 mm Pit depth, 4000 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.
· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Full Collective control system, add as below. For Lift travelling above First floor & up to Eighth floor
Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 Kv
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.
Design,fabrication,assembling,supply,installation,testing and commissioning of cubicle type LT panels suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick,entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable ,cable alleys ,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels Main LT Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1250A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA, (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB Note:- 1) For use of 4 pole ACBs in place of 3 pole MCCBs add 15% in rate of 3 pole ACB.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 630A up to 800A MCCB.
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Providing & erecting 4 Pole MCCB, 415 V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB.
HVAC Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 4 Pole MCCB, 415 V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 630A up to 800A MCCB.
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 630A Capacity at 40oC ambient temperature Sandwich type Aluminium Conducto tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection,36/40KA short circuit rating for 1sec, Insulation Class F (155 C) , casing made of minimum 1.5mm hot dipped / electro Galvanized /Epoxy powder coated steel sheet enclosure having Mechanical strength certification up to IK10 with required shade of paint having overall cross sectional area not more than 0.0170 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with Horizontal / Vertical G.I. Support at required interval with External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specification
Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for Aluminium 630A 3 phase 4 wire 415V, 50 Hz A.C ,36/40kA short circuit rating for 1 sec Sandwich type Aluminium BBT. with necessary accessories complete
Supplying, installing & Commissioning Vertical or Horizontal 90 Degree Elbow for Sandwich type Aluminium Compact bus trunking/ rising mains Suitable for 630A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply, 36/40kA short circuit rating for 1 sec Made of minimum 1.5mm Thick Galvanised sheet metal enclosure (IP54/55) duly powder coated with all necessary accessories complete confirming to IEC 61439-6 as per specification
Providing & erecting 4 Pole MCCB 415V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 32A to 125A 3 phase 4 wire 415V, 50Hz AC Supply made with High Grade Plastic enclosure with provision of MCB/ MCCB without (MCB/MCCB) complete as required confirming to IEC 61439-6 as per specification
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Supplying and fixing dual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrent access point with POE in networking as per specification no. WG-NAS/LAP2
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 13 Passenger/884Kg · Floors :- G+7 floor (8 Stops/8 Landings) · Travel :- 21 to 29.4 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.5mps VS · Car/Landing door clear opening of 1000 mm wide x 2000 mm high · Clear Car size of 2600 mm wide x 1900 mm deep x 2250mm high · Lift shaft available having clear size of 2000 mm wide x 2500 mm deep, +/- 1500 mm Pit depth, 4000 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.
· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Full Collective control system, add as below. For Lift travelling above First floor & up to Eighth floor
Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.
Design,fabrication,assembling,supply,installation,testing and commissioning of cubicle type LT panels suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick,entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable ,cable alleys ,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels
Main LT Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
HVAC Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 4 Pole MCCB, 415 V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 6 Passenger/408Kg · Floors :- G+3 floor (3 Stops/ 3 Landings) · Travel :- 9 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1900 mm wide x 1700 mm deep x 2250mm high · Lift shaft available having clear size of 1850 mm wide x 1850 mm deep, +/- 1500 mm Pit depth, 4000 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.
· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Full Collective control system, add as below. For Lift travelling above First floor & up to Eighth floor
For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.
Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of XLPE insulation instead of FR-XLPE insulated armoured cable reduce rates by 5 %
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.
Design,fabrication,assembling,supply,installation,testing and commissioning of cubicle type LT panels suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick,entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable ,cable alleys ,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels Main LT Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
HVAC Panel INCOMER Supplying and erecting metal work in CRCA sheet (16 guage) with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 4 Pole MCCB, 415 V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
OUTGOING Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 6 Passenger/408Kg · Floors :- G+3 floor (3 Stops/ 3 Landings) · Travel :- 9 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1900 mm wide x 1700 mm deep x 2250mm high · Lift shaft available having clear size of 1850 mm wide x 1850 mm deep, +/- 1500 mm Pit depth, 4000 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.
· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Full Collective control system, add as below. For Lift travelling above First floor & up to Eighth floor
For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 Kv
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF Design, Fabrication, Assembling, Supply, Installation, Testing and Commissioning of cubicle type LT panels suitable for 415 V 3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers, 3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity, DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick, entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs, solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable, cable alleys, cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels:
MAIN PCC PANEL MAIN PANEL (As Mentioned in Tender Specifications & Master SLD.) INCOMER: 2 No - 250A FP MP based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 36KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUS COUPLER: 1 No- 250A,FP, MP 36kA MCCB WITH O/C, S/C, E/F WITH RS 485 PORT (BUS COUPLER) (Ics=Icu=100% upto 415 V) with R-Y-B BUSBAR: 250A, 36kA TPN Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: (36kA Ics=Icu=100% upto 433V) with on/off/trip indication lamps & multifunction meter 2 No : 160 Amps 4P TM MCCB, 25kA with E/F protection 2 No : 80 Amps 4P TM MCCB, 25kA with E/F protection 10 No : 63 Amps 4P TM MCCB, 25kA with E/F protection
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 8 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW RCCB/RCCB
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -
specification no. SW-SWR/MCB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG PW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/65Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 6 Passenger/408Kg · Floors :- B+ G+8 floor (10 Stops/ 10 Landings) · Travel :- 42 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1900 mm wide x 1700 mm deep x 2250mm high · Lift shaft available having clear size of 1850 mm wide x 1850 mm deep, +/- 1500 mm Pit depth, 4000 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Liftcar, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 16 Passenger/1088Kg · Floors :- G+1 floor (2 Stops/2 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 1000mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep, ......mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.
Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. SITC of Electric Traction Passenger Lift with 1299498 · Rated capacity :- 10 Passenger/680Kg · Floors :- G+1 floor (2 Stops/2 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep, ......mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code &
Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date For Full Collective control system, add as below. For Lift travelling above First floor & up to Eighth floor
For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.
Supplying, erecting, testing and commissioning of 20HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode withinverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting hot dipped galvanised cover suitable for ladder/perforated type Cable tray manufactured from 18 SWG GI sheet of 500mm width & 20 mm height complete with necessary hardware.
supply, Installation, Testing and Commissioning of Isolator Box With 63A FP MCB, IP67 Enclosure Suitable for outdoor environment conditions with gasket & locking system.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 1.0TR ( 441 cfm ) to 1.3TR (512 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.8TR (575 cfm) to 2.7TR (953 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation complete.
Supply, installation, testing and commissioning of Ceiling suspended double skin air handling units (with mixing box ) AHU housing shall be 45±5 mm thick with thermal break profile constructed with of 0.8 mm thick galvanized pre-plasticized/powder coated sheet on outside and 0.8 mm thick plain GI sheet inside with PUF of 48 kg/m3 density insulation in between sheets to make 45±5 mm thick finished panels. The AHU shall have a fan section with DIDW backward curved centrifugal fan, TEFC IE3 motor suitable for 415+ 10% volts, 3 phase 50 Hz AC supply. motor mounting arrangement inside the casings, insulated joint less stainless steel condensate drain pan, belt drive system and with vibration isolators, coil section for VRF refrigerant 4/ 6 / 8 row, extruded aluminium damper on the outlet of AHU, filter section with 90% efficiency down to 10 micron & Microvee filter with 99% efficency down to 05 micron, double canvas connections and access doors to attend the motor/fan, etc complete as per drawings and specifications. 12 TR / 4800 CFM / 25 ESP
Supply, installation, testing and commissioning of Ceiling suspended double skin air handling units (with mixing box ) AHU housing shall be 45±5 mm thick with thermal break profile constructed with of 0.8 mm thick galvanized pre-plasticized/powder coated sheet on outside and 0.8 mm thick plain GI sheet inside with PUF of 48 kg/m3 density insulation in between sheets to make 45±5 mm thick finished panels. The AHU shall have a fan section with DIDW backward curved centrifugal fan, TEFC IE3 motor suitable for 415+ 10% volts, 3 phase 50 Hz AC supply. motor mounting arrangement inside the casings, insulated joint less stainless steel condensate drain pan, belt drive system and with vibration isolators, coil section for VRF refrigerant 4/ 6 / 8 row, extruded aluminium damper on the outlet of AHU, filter section with 90% efficiency down to 10 micron & Microvee filter with 99% efficency down to 05 micron, double canvas connections and access doors to attend the motor/fan, etc complete as per drawings and specifications. 29 TR/ 11600 CFM / 25 ESP
SITC of AHU Interface kit with control Box,Electronic Expansion valve,PCB ,necessary thermistor, cabling & controls
Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.(working and standby system)
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying and erecting GI sheet 1.25 mm (18 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying & erecting GI sheet 0.6 mm (24 SWG having zinc coating of 275 microns with galvanisation process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards, etc. including cutting, bending, drilling, welding, rivetting etc. & painting with one coat of red lead paint & 2 coats of enamel paint.
Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2007.
Acoustic Insulation : Supply & fixing of Acoustic insulation for Supply air duct using 15 mm thick class 1 rating open cell nitrile rubber elastomeric insulation with density of 140-180 kg /m³. The insulation mamafactured as per BS 476 part & which should also meet UL 94 test supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209) should not support microbial growth (ASTM 2180, G21,G22) and should not emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.04w/m k @ 20 degC as per DIN EN 12667. and water vapor permeance of 0.10. Adhesive shall be used additionally with VOC level not excedding 50 grms / litre 10 mm thick.
Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction complete with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
Supply, installation, testing and commissioning of volume control box with collar for control damper of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete.
Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. Neck size 375x375
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (Between Indoor & Outdoor Units and for remote control units)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware.
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supply, fabrication, painting, Installation and testing of MS structural for outdoor/indoor units ( not separately specified under item) as per Specified below. Vendors shall note that scope of standard support requirement for pipes, ducts and cable trays as per approved drawing are already included in respective items' price and this item only covers structural Stand for ODU or any special requirement which need to be provided as per additional requirement due change in position, drgs etc. complete. The item also include providing & applying two coat of approved make anti corrosive paint over a coat of primer as per manufacturers recommendations.
Supplying, erecting, testing & commissioning exhaust air system, ductable circular inline exhaust air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.
Supplying, erecting, testing & commissioning exhaust air system, ductable circular inline exhaust air fan inlet unit having 300 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.
Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.
Supplying, erecting, testing and commissioning of 22HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode withinverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete.
Supplying, erecting, testing and commissioning of 20HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode withinverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete.
Supplying, erecting, testing and commissioning of 16HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode withinverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete.
Supplying, erecting, testing and commissioning of 14HP, VRF/VRV airconditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode withinverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting hot dipped galvanised cover suitable for ladder/perforated type Cable tray manufactured from 18 SWG GI sheet of 200mm width & 20 mm height complete with necessary hardware.
supply, Installation, Testing and Commissioning of Isolator Box With 63A FP MCB, IP67 Enclosure Suitable for outdoor environment conditions with gasket & locking system.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of Ceiling suspended double skin air handling units (with mixing box ) AHU housing shall be 45±5 mm thick with thermal break profile constructed with of 0.8 mm thick galvanized pre-plasticized/powder coated sheet on outside and 0.8 mm thick plain GI sheet inside with PUF of 48 kg/m3 density insulation in between sheets to make 45±5 mm thick finished panels. The AHU shall have a fan section with DIDW backward curved centrifugal fan, TEFC IE3 motor suitable for 415+ 10% volts, 3 phase 50 Hz AC supply. motor mounting arrangement inside the casings, insulated joint less stainless steel condensate drain pan, belt drive system and with vibration isolators, coil section for VRF refrigerant 4/ 6 / 8 row, extruded aluminium damper on the outlet of AHU, filter section with 90% efficiency down to 10 micron & Microvee filter with 99% efficency down to 05 micron, double canvas connections and access doors to attend the motor/fan, etc complete as per drawings and specifications. 50 TR / 20000 CFM / 50 ESP
SITC of AHU Interface kit with control Box,Electronic Expansion valve,PCB ,necessary thermistor, cabling & controls
Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.(working and standby system)
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying and erecting GI sheet 1.25 mm (18 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying & erecting GI sheet 0.6 mm (24 SWG having zinc coating of 275 microns with galvanisation process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards, etc. including cutting, bending, drilling, welding, rivetting etc. & painting with one coat of red lead paint & 2 coats of enamel paint.
Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2007.
Acoustic Insulation : Supply & fixing of Acoustic insulation for Supply air duct using 15 mm thick class 1 rating open cell nitrile rubber elastomeric insulation with density of 140-180 kg /m³. The insulation mamafactured as per BS 476 part & which should also meet UL 94 test supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209) should not support microbial growth (ASTM 2180, G21,G22) and should not emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.04w/m k @ 20 degC as per DIN EN 12667. and water vapor permeance of 0.10. Adhesive shall be used additionally with VOC level not excedding 50 grms / litre 10 mm thick.
Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction complete with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
Supply, installation, testing and commissioning of volume control box with collar for control damper of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete.
Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. Neck size 375x375
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (Between Indoor & Outdoor Units and for remote control units)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware.
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supply, fabrication, painting, Installation and testing of MS structural for outdoor/indoor units ( not separately specified under item) as per Specified below. Vendors shall note that scope of standard support requirement for pipes, ducts and cable trays as per approved drawing are already included in respective items' price and this item only covers structural Stand for ODU or any special requirement which need to be provided as per additional requirement due change in position, drgs etc. complete. The item also include providing & applying two coat of approved make anti corrosive paint over a coat of primer as per manufacturers recommendations.
Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supply,Installation,Testing & Commissioning of Carbon Monoxide based Gas detection system comprising of co sensors, transmitter with built in power supply units. Detectors shall be mounted in enclosure with sensor lid projection at distance not more than 1500 mm from floor and shall have suitable arrrangement to fix on wall. Device shall be comprising of sensors, transmitter unit, power supply unit suitable for loop powered 230 VAC supply, Sensor shall have range of 0-250 PPM non linear sensing, sensors shall be solid state type with operating temperature range of -10 to 50 deg.c and relative humidity of 10% to 100% [non condensing]. Enclosure shall be in minimum IP 65 construction as per the specifications
Supply, installation, testing and commissioning of motorised combined smoke & fire damper (UL listed) complete with control panel, inter connecting wiring at locations shown in approved shop drawings and as per specifications. Smoke & Fire Dampers.
Actuators
Control Panel & Wiring
Supplying, installing, testing and commissioning of of MCB, DOL / star delta stater comprising of contactors, relays, pushbutton station, facility for remote operation through push buttons/ BMS wih RS 485, Auto manual switches and safety devices. ( Fire Signal provision) 53000 CFM 25 mmWG
Supply, Laying, terminating, testing and commissioning of 1.1.KV grade armoured Xlpe Cable armourd cables on cable trays, structural supports and cable supports provided, include unloading,shifting upto site.The scope includes clamping of cables by ready made G.I. spacers, screws, saddles or clamps fabricated out of M.S. strip 3 mm thick, Treasing and Clamping of Cable on cable tray, supply of all clamping materials and hardware etc., providing cable tags made out of aluminium strip and 75x20 mm in size with cable number and size punched on it and glanding on both the motor and control panel end. Cable tags shall be tied to cables at every 20 meter interval and at both the ends.Empty cable drums shall be returned to stores. In case of laying unlisted cables, rate of cable whose outer dia is closest to the cable sizes quoted shall beapplicable. 3C x 6 Sqmm Copper Cable
Supplying, erecting, testing & commissioning exhaust air system, ductable circular inline exhaust air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.
Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 250 mm. /300 mm.sweep complete with necessary brackets for fixing cabin fans, wire etc.
Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.
SHANTI CONSTRUCTION (GUJ) PVT. LTD.
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid