Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being Lowest Bid value | |
| 2 | L2₹91.5 L+₹10.3 L (12.7%)Rejected-AOC 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | L2 | Rejected-AOC Rejected being L2 bidder | |
| 3 | L3₹1.1 Cr+₹28.0 L (34.5%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 bidder |
Tender Value
₹97.8 L
EMD Value
₹1.7 L
Closing Date
9 Mar 2020, 6:00 pmClosed
CWE PANAGARH
HQ CWE PANAGARH MES PO PANAGARH DIST BURDWAN WB PIN 713420
PROVN OF CERTAIN SANCTIONED WORKS FOR ELECTRIC PANELS, CABLES, DIGITAL ENERGY METER, VT PUMP, CHLORINE DOZERS, SWT, TRANSFORMER AND GENERATOR SET AT PANAGARH MIL STATION UNDER GE PANAGARH
2020_MES_317883_1
8606/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
PANAGARH
As per Tender Documents
7 documents required · 7 mandatory
₹1,000
Yes
GE PANAGARH
₹1.7 L
Yes
21 Apr 2020
24 Jan 2020
12 Mar 2020
24 Jan 2020
9 Mar 2020
14 Feb 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil, complete all as specified and as directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc. 25cmin soft/loose soil ,complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for laying fly ash bricks for cable protection complete all as specified and as directed.
M&L for 80 mm bore steel tubing light grade ISI marked for protection of cable including necessary joint, complete all as specified and as directed.
M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joint, complete all as specified and as directed.
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 120 Sqmm 3.5 core and testing in trenches or passing through pipe 1100 volts grade, complete all as specified and as directed. Note: (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
All as per item No 8 here-in-before but 50 Sqmm 3.5 core .
All as per item No 8 here-in-before but 16 Sqmm 4 core .
All as per item No 8 here-in-before but 10 Sqmm 2 core . Note: (For Sl No 08 and 09) : Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
Dismantling/taking out carefully of old LT cable of any size type or core and kept aside for reuse / rerouting / jointing / replacement etc , complete all as specified and as directed.
Dismantling / taking out old un-serviceable bricks from the trench for taking out old cables etc. and Staking aside for reuse or disposal , complete all as specified and as directed.
M&L for earthing with galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150mm to a packed thickness of 150 mm on all sides with and including necessary exacavation earth work including GI strip 25 X 4 mm as earthing lead connected with bolted and reverted to earth plate at one end in and connected to continuous GI strip 25 X 4 mm and including all as shown in electrical plate No 5.
Supply, commissioning and testing Outdoor type LT Distribution Panel, double door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x 1200 x 600 mm) for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 54 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement including taking down old one. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-250 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Incoming) (Make - C&S/GE/Schneider/Seimens) (d) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (Make - C&S/GE/Schneider/Seimens) (e) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-03 No(Outgoing) (Make - C&S/GE/Schneider/Seimens) (f) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (Make -C&S/ GE/Schneider/Seimens) (g) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos
Supply, commissioning and testing Outdoor type LT Distribution Panel, double door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x 1200 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 54 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement.. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-160 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC- 01 No(Incoming) (Make - C&S/GE/Schneider/Seimens) (d) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (Make - C&S/GE/Schneider/Seimens) (e) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - C&S/GE/Schneider/Seimens) (f) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (Make - C&S/GE/Schneider/Seimens) (g) MCB-40 Amp, 2 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-08 No(Outgoing) (Make -C&S/ GE/Schneider/Seimens) (h) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (j) S & F digital voltmeter 0-500 V = 01 Nos
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure.
Supplying , fixing and testing of digital electronic type energy meters single phase 240 V, 10-60 Amps, 50 Hz, LCD display with optical port The accuracy should not get effected by external magnetic field. It should be with LED indication proportional to KWH for on spot calibrationcheck including fixing arrangement nad connecting up with copper reducing terminal with existing circuit brakers, sealing to energy meter, sealing materials, necessary tools for sealing and marker pen with bold/readable letters, complete all as specified and directed by the Engineer-in-Charge . (i) Frequency range : 50 Hz+ 5% (ii) Starting current : 0.4 % of basic current (iii) Operating temp : 0 to 55 Deg Cent (iv) Power factor range: 0.5 lag - UPF -0.8 Lead (v) Meter display -6 digit ( 1 Decimel digit) (vi) LED/LCD indication for power On, Earth tamper, Current Reversal and other relevant tamper Meter shall continue to operate satisfactory under the following condition:- (a) Phase/Neutral reversed (b) Supply side and Load side interchanged to earth (c) Full load/partiall load terminated to earth (d) Combination of any of the above. Note:- Copper reducing terminal is deemed to be included in rate.
All as per items No. 18 here-in-before but of 3 Phase 4 Wire kWh tri vector meter, class 1, 10-60 Amps .
All as per items No. 18 here-in-before but of 3 Phase 4 Wire kWh tri vector meter , 50-200 Amps .
Supply and fixing polycarbonate hinge type box for 3 Phase meter.The Box will have minimum two sealing provision .Colour of the box should be transparent so that without opening the box cover meter display can be read , complete all as specified and directed by the Engineer-in-Charge . Note: The box shall be of suitable size to incorporate Meter mentioned in item No 19 & 20.
Supplying and fixing sub main wiring with 16x4 sqmm + 1 x 16 sqmm nominal cross sectional area for earth wire, multistranded copper conductor FRLS cable, ,1100 Volts grade unseathed FRLS PVC insulated (green colour) cable for earth continuity wire includingall acessorries compelet all as specified and directed. Note:- 4 run of cable and 1 run of earth continuity wire shall be measured as one length.
All as per item No 22 here in before but cable size 10 Sqmm 4 run + 1 x 10 Sqmm earth wire. Note:-4 run of cable and 1 run of earth continuity wire shall be measured as one length.
Supplying and fixing two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing and caping (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire , complete all as specified and as directed.
Supply and fixing angle iron of size 45x45x5mm, ISI mark and making a frame of angle size 2'x2'x 1' and apply two coat of enameld paint for installing three phase electric meters , complete all as specified and directed y the Engineer-in-Charge .
M&L for PCC (1:3:6) type C-1 (with using 20 mm graded stone aggregate) as coping of pole including necessary form work as required , complete all as specified and directed y the Engineer-in-Charge .
Supply, install, commissioning and testing of vertical turbine pump set capacity 1500 LPM at 64 mtr head 8 stage with discharge and suction case stainer self water lubricated with stuffing box arrangement in clock wise rotation complete with all ball impeller lock collect, impeller shaft, impeller shaft sleeves, intermediate shaft sleeeves ball bearing, intermediate bearing pump motor coupling asseccerios complete all as specified and directed along with supply hollow shaft electric driven sqirrel case induction motor capacity 45 HP 1450 RPM (Efficency class IE2 ) ,complete all as specified and as directed. Make: CROMPTON GREAVES / KIRLOSKAR / KSB/WPIL LTD/ Equivalent
Supply, install, commissioning and testing of Submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) of capacity 20 HP and pump having discharge 900 LPM at Head minimum 80 mtr, suitable for 4" outlet dia as per manufacturer instruction and testing, complete all as specified and as directed by the Engineer-in-Charge .
Supply, install, commissioning and testing of Submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/300 mm) of capacity 40 HP and pump having discharge 2160 LPM at Head minimum 80 mtr, suitable for 6" outlet dia as per manufacturer instruction and testing , complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix PVC insulated copper cable, HRFR, water proof best quality of size 3 core 10 Sqmm multistranded for connection to submersible pump set of cap upto 20 HP, testing and commissioning , complete all as specified and as directed by the Engineer-in-Charge .
Supply & fix PVC insulated copper cable, HRFR, water proof best quality of size 3 core 25 Sqmm multistranded for connection to submersible pump set of cap upto 40 HP, testing and commissioning , complete all as specified and as directed by the Engineer-in-Charge .
Supply & fix Fully Automatic star delta starter for Submersible Pump set of rating capacity 25 HP, 415 volts, 50 Hz having with sheet metal encloser and relay range 3 phase 21 to 42 Amps rating along with supply and fix three phase preventer panel mounting complete all as specified and as directed.
Supply & fix Fully Automatic star delta starter for Submersible Pump set of rating capacity 50 HP, 415 volts, 50 Hz having with sheet metal encloser and relay range 3 phase 37 to 63 Amps rating along with supply and fix three phase preventer panel mounting complete all as specified and as directed.
Supply, install, commissioning and testing of Chemical dosing system suitable to inject solution minimum 25 LPH comprising dosing pump couple with electric motor of capacity 0.5 HP , 1440 RPM assemble with agitator dosing and agitator in single motor agitator with SS sweep blade duly FRP coated FRP tank 150 Ltrs capacity, complete unit mounted in geavy duty MS fabricated frame duly acnticorrosive paint complete and testing compelte with Chemical grade PVC NRV , complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix UPVC pipe (Schedule 80) suitable for chemical chlorine dosing of best quality of size 15 mm dia with complete fittings,complete all as specifeied and as directed.
Material and labour for straight plain brass ferrules (or connecting screw) screwed bolt ends of 15 mm bore pipe, complete all as specified and as directed.
Supply and fix Venturi both end flanged type suitable for 150 mm dia pipe 3 ft long with nut bolts and gasket ,complete all as specified and as directed.
Cutting of Existing DI/GI pipe, 150 mm bore in position of taking off connection by inserting new flange by welding and fixing with gasket nut, bolts, complete all as specified and as directed.
Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 10 Sqmm 4 core complete all as specified and directed by Engr-in Charge.
Material and labour for Automatic star delta starter and Supply and fixing for Fully Automatic star delta starter for Submersible Pump set of rating 1 HP, 415 volts, 50 Hz having with sheet metal encloser and relay range 3 phase 1.6 to 2.5 Amps rating along with supply and fix single phase preventer panel mounting, complete all as specified and as directed.
Excavation over areas not exceeding 1.5 m depth and getting out in soft/loose soil, complete all as specified and as directed.
Excavation over areas exceeding 1.5 m depth and getting out in soft/loose soil, complete all as specified and as directed.
M&L for sand filling under floor or in foundation including watering and consolidation ,complete all as specified and as directed.
M&L for flyash brick work straight or curved on plan exc 6 m mean radius built in CM 1:6, complete all as specified and as directed.
M&L for hard core gauge broken bricks n. exc 63 mm, deposited spread and levelled n. exc 15 cm, water and rammed to a true surface,complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundations, filling , mass-concrete, foundation for stay set /Pole/ FPB etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
M&L for RCC M-25 Design mix concrete for foundation including raft footing foundation ,plinth beam, bases for column, complete all as specified and as directed.
M&L for RCC M-25 Design mix concrete for walls.retaining walls,basement walls,ballast walls and the like any thickness above top of footing including attached plaster and buttresses, complete all as specified and as directed.
Removing excavated material (soil) exceeding 250 m but n exc 500 m and depositing where directed, complete all as specified and as directed.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in plinth protection and mass concrete,complete all as specified and as directed.
M&L for formwork to edges of concrete flats,treads breacks in floor , window cills , concrete railings openings in concrete walls, floor, roofs , sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide, completed all as specified and as directed.
M&L for steel formwork to faces of walls, abutments, parapets, staircase railing and similar work including attached palasters, butteress etc vertical or to batter edges of concrete flats,treads breacks in floor , window cills , concrete railings openings in concrete walls, floor, roofs , sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide, completed all as specified and as directed.
M&L for Rendering10mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, using WPC, surfaces finished even and smooth without using extra cement ,complete all as specified as directed. (Note: WPC measured separately).
Supply only intergal WPC,complete all as specified as directed. Note: WPC shall be used as per manufacturer instructions
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
All as per item no 55 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups,spacers and binders, complete all as specified and as directed.
M&L for PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping including necessary formwork, complete all as specified and as directed by Engr-in-Charge.
M&L for Providing 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in TOP flooring including finishing smooth and even with using extra cement, complete all as specified and as directed.
M&L for DI pipe of 100 mm bore with spigot and socket end rubber gas cate joint(titon) centrifugally cast class k-7 conforming to IS 8329-2000 laid in trenches/ on surface/ over masonry pillar , complete all as specified and as directed. Note: Cost of joint included in the qoted rate (Make: Electro steel/Tata/ Jindal).
M&L for DI pipe of 150 mm bore with spigot and socket end rubber gas cate joint(titon) centrifugally cast class k-7 conforming to IS 8329-2000 laid in trenches/ on surface/ over masonry pillar , complete all as specified and as directed. Note: Cost of joint included in the qoted rate (Make: Electro steel/Tata/ Jindal).
M&L DI bend any type, radius and angles, tappers and type (straight, bend, increasing, decreasing, or double socket etc. Tee pipes single branch Y junction, double branch cross (all socket, socket and Spigot or flanged ends) collors, caps and plugs for the Pipes socket and Spigot. All socket and flanged upto bore of 150 mm , complete all as specified and as directed.
Supply and fixing sluice valve of size 100 mm (conforming to IS-14846-2000) long type CI body, gland thrust plate, hand wheel of grey cast iron, spindle of high tensile brass, nut body seal ring and wedge facing ring head, bronze bolt nut of high carbon steel, gasket of compressed fiber gland packing of jute having flanged & drilled type nominal pressure rating , PN 1.6 including jointing flanged joint with rubber fibre jointing ring bolt nut & washer etc , complete all as specified and as directed.
Supply and fixing sluice valve of size 150 mm (conforming to IS-14846-2000) long type CI body, gland thrust plate, hand wheel of grey cast iron, spindle of high tensile brass, nut body seal ring and wedge facing ring head, bronze bolt nut of high carbon steel, gasket of compressed fiber gland packing of jute having flanged & drilled type nominal pressure rating , PN 1.6 including jointing flanged joint with rubber fibre jointing ring bolt nut & washer etc , complete all as specified and as directed.
M&L for brick massonary valve pit with brick in CM (1:6) with 100mm thick PCC work 1:3:6 type C2 from fundation over 75mm thick hard core, sub class B brick full brick thick wall, 15mm thick internal and external plaster at bottom of the pit of size 1200x1200x900 mm along with valve pit cover made out MS angle iron 50mm x 50mm x 6mm frame work, , MS platecover made out of 3.15mm thick with locking arrangment fixed over the valve pit including a coat of synthetic enamel paint over a coat of red oxide primer complete including necessary frame work welding, drilling etc , complete all as specified and as directed.
M&L for laying bricks common brunt clay building bricks, sub class 'B' for cable protection , complete all as specified and as directed.
M&L for 80 mm bore GI tubing medium grade ISI marked for protection of cable including necessary joint ,complete all as specified and as directed.
Supply, erecting, testing and comissioning of silent (Sound proof enclosure) type Diesel Engine Driven Generating Set capable of delivering 100 KVA, (80 KW at 0.8 Power Factor) Water & Coolant cooled, 415 Volts (AC three phase, 4 wire system of supply) 50 HZ 1500 RPM complete with Automatic on Mains Failure (AMF) control panel. Governing class ( As per ISO 8528: Part V)- G3, Noise level as per CPCB norms-less than 75 dB, Fuel tank capacity as per manufacturer.The DG set shall consists of diesel engine coupled to a matching alternator, through flexible copuling and mouted on common base frame and complete with control panel suitable for climatic conditions prevelanet at Panagarh (WB) with suitable derating factors as applicable and meeting specifications as elaborated here-in-after. (i) ENGINE (Prime Mover) : Diesel Engine 1500 RPM, direct injection, multi cylinders, four stroke, confirming to ISO 3046/BS 5514, water and coolant cooled, naturally turbo charged, capable of giving adequate power to drive alternator capable of delivering 100 KVA at outdor atmospheric conditions at Panagarh (WB), (Taking all derating factor into consideration), 12 V battery as per manufacturer, electric start complete with fly wheel all standard fittings / fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system with electronic governor and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc.) fuel tank and first fill of lub oil and other consumables etc and self starting system incl batteries etc complete. (ii) ALTERNATOR : Brushless AC alternator, 3 phase, 415 Volt, 4 wire, rated for output of 100 KVA,(80 KW at 0.8 Power Factor) 1500 RPM, IP 23 Protection class enclosure, insulation class "H", salient pole, revolving field, self excited, self regulated,single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.
item no 1.77 contd…. (iii) BASE PLATE : Made out of structural steel as per manufacturers recommended design/specifications. (iv) ACOUSTIC ENCLOSURE : Weather and sound resistant enclosure with insulation conforming to UL94-HF1 Class for flammability, sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 dB (A) at a distance of 1 M at 75% load under field condition 70 dB at 3 M from Gen set when DG set is working at full load along with testing conformance, lebeling certification etc. (v) Foundation/Plinth/Base : Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the set and height of plinth shall not be less than 0.5M (vi) AMF Panel: Powder Coated Control Panel manufactured with CRCA sheet suitable for Automatic on Mainsfailure with MCCB of suitable rating with short circuit protection, controller with displays of voltage, current, KW , frequncy and KWH indicating lamps for "load-ON" and "set running". Current transformers of suitable rating, Aluminium Bus bars of suitable capacity with incoming and outgoing terminations and control fuses duly wired and ferruled complete on all respect. (vii) MISC : Tool kit, operation and maintenance catalogue, spare part list, overhaulling manuals, guarantee card etc shall be provided as per manufacturer standard parctices. (viii) Fully automatic AC operated additional battery charger of suitable capacity incl suitable size twin core copper wires fixed with copper lugs shall be provided from charger to batteries for charging of batteries without extra cost.
item no 1.77 contd…. Make of the complete DG set: - Kirloskar /Cummins/Greaves Power and Equivalent Make of Alternator :- Cummins/Stamford/Kirloskar electric/Crompton Greaves and Equivalent (ix) Controller shall be microprocessor based fully configured with garphical LCD display, monitoring features for all electrical parameters, lub oil parameters, Battery parameters and self diagnostics faeatures for all important parameters.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metreswith top edge of the plate not less than 1.5 metre below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150mm to a packed thickness of 150 mm on all sides with and including necessary exacavation earth work including GI strip 25 X 4 mm as earthing lead connected with bolted and reverted to earth plate at one end in and connected to continuous GI strip 25 X 4 mm and including all as shown in electrical plate No 5
Supply, install, commissioning and testing Outdoor type LT Distribution Panel, weather proof, double door type, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (900 x 900 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 54 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement including taking down old one. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-200 Amp, 4 pole, 25KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No (Incoming) (Make - C&S/GE/Schneider/Seimens) (d) Manual Changeover Switch of current capacity 200A - 01 No (Make - C&S/GE/Schneider/Seimens) (e) MCCB-160 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (Make - C&S/GE/Schneider/Seimens) (f) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (Make - C&S/GE/Schneider/Seimens) (g) S&F digital ammeter ( 0-200A) - 01 No (h) S & F digital voltmeter 0-500 V = 01 Nos
Surface excavation n. exc 30 cm deep soft/loose soil and averaging 15 cm deep and getting out loose/soft soil,complete all as specified and as directed.
M&L for sand filling under floor or foundation including watering and consolidation,complete all as specified and as directed.
M&L for Plain cement concrete 1:4:8 Type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and as directed.
M&L for Providing 100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded aggregate) as in sub base flooring,complete all as specified and as directed.
M&L for Providing 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded aggregate) finishing smooth and even with using extra cement, complete all as specified and as directed.
M&L for brick work with subclass 'B' bricks old size bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6, complete all as specified and as directed.
M&L for Rendering 15mm thick in cement mortar (1:4) on fair faces of brick walls or concrete surfaces, using WPC, surfaces finished even and smooth ,complete all as specified as directed. (Note: WPC measured separately).
Material and labour for steel work in tubular trusses Post/columns including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade ST-240, complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size conformed to IS 15658-2006 of 60mm thickness M-35 grade complete all as specified.
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws ,complete all as specified and as directed by Engrs-in-Charge.
M&L for Preparation of steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer ,complete all as specified and as directed by Engrs-in-Charge.
M&L for Two coats of white washing on wall surfaces ,complete all as specified and as directed by Engrs-in-Charge.
Supply and install, testing and commissioning of step down outdoor type copper would transformer of capacity 100 KVA complete (Plateform mounted) with standard, fitting HT 11KV, 3 Phase, LT 433 volts, 3 phase 4 wire with off load changer over switch on HT side to vary secondary voltage all as per IS 2026 ,complete all as specified and as directed by Engrs-in-Charge. The transformer shall be comprising of the following items :- (a) Oil conservation with filling hole and cap drain valve and oil level gauge (b)Silica gel breath or with connecting pipe, first fill of dehydrating agent (c)Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air spaon ( Pressure release valve) (d)Air release plug (e)Oil tempeture indicator (gauge) having range 00 C to 12000 C , 100 mm dial type including shut off valve between conservator and main tank (f)Thermometer pocket (g)Drain valve with threaded adopter (h)Filter valve with threaded adopter ( Top and bottom) (i)Sample valve (j)Inspection cover (k)Cover lifting eyes (l)Jacking pads, handing and lifting lugs (m)Fly wheels (n)Rating plate and terminal marking plate (o)Extra bushing for neutral out side the LV side
ITEM NO. 84 continue…… (p)Hand hole of sufficient size to asess the interior of the tank (q)First filling of transformer oil complete all as directed. (r)Testing of Transformer : (i) Double voltage/Double frequency test (ii) Full load Test (iii) Regulation Test (iv) Efficiency test (v) Polarity test & other type & routine test as per IS. (vi) Water load test at site (s) The cost for testing of transformer shall be deemed to be included in the quoted rate. (t) The cost of plateform as per manufacture's design/recommendation shall be deemed included in the quoted rate.
Supply and install HT 11 KV outdoor type GOD air break switch suitable for vertical / horizontal mounting complete with drop out fuses having 09 insulators GI operating rod of suitable size length of rating 200 amps ,complete all as specified and as directed by Engrs-in-Charge.
M&L for lighting arrester( expusion) type having voltage rating 12 KV, Rated frequency 0-50 HZ, Nominal Discharge current 65 KA(Heavy duty) complete with all fittings , suitable for 11KV, 3-Phase, earthed distribution system ISI marked ,complete all as specified and as directed by Engrs-in-Charge.
S&F Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 ,complete all as specified and as directed by Engrs-in-Charge.
Supply ,laying and testing of cable XLPE insulated screened PVC bedded, GI strip armoured electric power cable heavy duty with stranded alluminium conductor of 11 KV, 3 Core 95 Sq mm ,complete all as specified and as directed by Engrs-in-Charge. Notes : (i) Cable to be un-rolled/de-rolled in proper way by suitable means i.e. dram holder/hydra/Jack etc. mannually un-rapping not permitted. (ii) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item. (iii) In addition to normal PCC cable route indicator at 50 mtr apart , a Barricate Tape of width 150 mm duly continuously written in block letter "CAUTION HIGH VOLTAGE CABLE BURRIED BELOW" to be burried below 300 mm of GL along the cable route during returning filling and cost for the same deemed to be included in the item rate.
Supply and fix cable jointing kit of heat shrinkable type 11 KV outdoor type with all accessorioe , jointing material for 3 core 95 Sq mm,complete all as specified and as directed by Engrs-in-Charge.
Supply and fix cable jointing kit of heat shrinkable type 11 KV straight through joint with all accessories , jointing material for 3 core 95 Sq mm ,complete all as specified and as directed by Engrs-in-Charge.
Supply and fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sq. mm 3.5 Core ,complete all as specified and as directed by Engrs-in-Charge.
M&L for un-reinforced precast concrete cable cover, class HV, type I ( with peak, size 300mm x 180mm x 40mm complete with MES marking on the top of the cover ,complete all as specified and as directed by Engrs-in-Charge.
M&L for 80 mm bore steel tubing light grade ISI marked for protection of cable including necessary joint complete with taking down old unserviceable,complete all as specified and as directed .
M&L for brickwork in CM (1:4) using sub class B bricks straight or curved on plan exceeding 6 Mtr mean radius ,complete all as specified and as directed by Engrs-in-Charge.
M&L for 15mm thick in cm (1:4) rendering on fair face of brick work finished even & smooth without using extra cement ,complete all as specified and as directed by Engrs-in-Charge.
M&L for 25x4mm galvanised iron strip including connection from earthing in continuation to end point ,complete all as specified and as directed by Engrs-in-Charge.
SCHEDULE OF CREDIT
UNITED BUILDERS
M/s Debendra Prasad Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .