Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC 143 C DR RAJENDRA ROAD KOLKATA 700 020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.2 L+₹18,796 (3.77%)Rejected-Finance 487 A 1 GOPAL MISHRA ROAD BEHALA KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | L2 | Rejected-Finance L2 | |
| 3 | L3₹6.3 L+₹1.3 L (26.5%)Rejected-Finance 10 WATERLOO STREET KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
24 Jan 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
Rectification of cable fault and allied electrical work under MES-II, PWD.
2024_WBPWD_786925_1
WBPWD/EE-KED/eNIQ-45Q/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
182 days
Maidan
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
O/O The Executive Engineer Kolkata Electrical Divi
21 May 2025
18 Dec 2024
27 Jan 2025
18 Dec 2024
24 Jan 2025
27 Dec 2024
26 Dec 2024
Amount
Supply & Delivery of 1.1 Kv grade 4 Core 16 Sqmm XLPE Armoured Aluminium underground Cable(Make- Polycab /RR KABEL / Gloster)
Supply & Delivery of 1.1 Kv grade 2 Core 10 Sqmm XLPE Armoured Aluminium underground Cable(Make- Polycab /RR KABEL / Gloster)
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Supply & laying 40 mm Dia HDPE pipe in underground trench 360 mm wide x 460 mm average depth after removing Paver blocks from road , cutting the cement concrete & making the good damages as to orginal finish after laying the pipe with sand, cc mixture & paver blocks as per direction of EIC.
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Finishing the end of following XLPE/PVC Al Ar armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials as to GS.
4C X 16 Sqmm
2C X 10 Sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
4C X 16 Sqmm
2C X 10 Sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
4 x 126/0.4 (16 sqmm)
2 x 36/0.3 (2.5 sqmm)
Dismantling steel tubular pole embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick net cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.Above 9.0 mtr. Size 0.6x0.6x1.91 mts
Providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/ polythene pipe entry, for street light wiring, without Loop Box.
S & F thermoplastic polycarbonate loop box(IP-66 ,Make-syntax) of size (10" x 8" x 4" ) including S & F 63A 4 stud copper connector -1 no and 16A MCB (C Curve,10KA) on Din Rail channel-01 no including all necy connection & arrangements.
S & F of 240V, 250 W, 30000 Lumens (minimum) LED Flood Light Fittings with IP 66 / 67, IK 10 protection including 10 KV SPD with CCT 6000 & Luminious efficiency 120Lumen/ Watt minimum or better, burning hour 75000, LED driver should withstand 440V for 8 hours.The LED luminaires and accessories shall have BEE Certification & LED should be with lens (Light efficacy will not get depriciated less than equal to 70% of the rated value over the lifetime of the Luminaries) (Make: Philips / WIPRO / Crompton) NOTE : All street light / compound light should contain internal surge protection with external 10KV surge protection (linline SPD). (Make :Philips / wipro / Crompton)
S & F of specially fabricated door for feeder pillar box of following sizes duly welded incl. S&F pin type hinge for the door,lock plate & door handle as per direction of EIC
Single Door 19"x14" of 3mm thick
Single Door 16.5"x21" of 3mm thick
Double Door 34"x43" of 3mm thick
Single Door 23"x33" of 3mm thick
Single Door 23.5"x29" of 3mm thick
Single Door 29.5"x25" of 3mm thick
Charges for Making provision for earthing with earthing attachment on pole by means of hook duly welded by skilled welder as per direction of EIC.
Dismantling the existing unserviceable pillar box after disconnection of all electrical connection & breaking the muffing & deposit the dismantled items to the respective section store including shifting the dismantled concrete from the site as per direction of EIC.
Muffing of the existing pillar box after breaking the existing muffing & shifting dismantled concrete from the site by brick structure with sand & cement mixture having size upto 4 ft x 3 ft x1 ft & neatly cemented finsh 3 mm thick as per direction of EIC. & shifting the dismantled concrete for the site as per direction of EIC.
Muffing of the existing pillar box after breaking the existing muffing & shifting dismantled concrete from the site by brick structure with sand & cement mixture having size upto 3 ft x 2 ftx 1ft & neatly cemented finsh 3 mm thick as per direction of EIC.
Charges for removing all the electrical connections like Main switches,busbar,timer, contactor, MCB etc. from existing feeder pillar boxes
S & F 10mm thick Hilamp sheet in existing feeder pillar boxes with SS nut bolts, washers etc.
Fixing only Sheet Steel Main Switch (Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall
100/125 Amps, On angle iron frame
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection( Make-Legrand)
The agency have to attend the rectification the works within 24 hours of its occurrence.
STAR ENTERPRISE (BID ID -6017390)
S. K. CHATTERJEE ELECTRICALS PVT LTD (BID ID -6026140)
technical_1744292.pdf
PDF • 0.54 MB
techsummary_1744292.pdf
PDF • 0.54 MB
finance_1744292.pdf
PDF • 0.54 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1744292.pdf
PDF • 0.55 MB
AOC45Q.pdf
PDF • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .