Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L1 | Accepted-AOC TENDER FOUND LOWEST AND REASONABLE HENCE ACCEPTED | |
| 2 | L2₹30.2 L+₹39,406 (1.32%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹33.3 L+₹3.5 L (11.9%)Rejected-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹34.6 L+₹4.8 L (16.0%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹35.8 L+₹6.0 L (20.3%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹36.2 L
EMD Value
₹76,500
Closing Date
31 Jul 2023, 6:00 pmClosed
TA YASHODA
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD PIN - 500003
SPL REPAIRS TO BLDG NO 33 MEADOWS LINE OF MH AND ROOF TREATMENT IN P 13D, P 69/4, P 1C, P 84/1, P 10C, P 68 AT HT, PROVN OF WALL PANELING AT BLDG NO 06, PROVN OF 05 X CABIN PARTITION WITH ALUMINUM AND GLASS FOR SQA LAB UNDER GE SOUTH SECUNDERABAD
2023_MES_604974_1
GE(S)/SEC/TOKEN-18 OF 2023-24
Open Tender
Civil Works
Item Wise
300 days
SECUNDERABAD
For Enlisted contractors class D and above category a (i) and b (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD
₹76,500
Yes
21 Aug 2023
22 Jun 2023
2 Aug 2023
22 Jun 2023
31 Jul 2023
12 Jul 2023
22 Jun 2023 - 11 Jul 2023
Amount
Demolition of cement concrete (un-reinforced ) of any description and in any position not otherwise specifically provided for complete all as specified and directed..
Taking down existing water proofing treatment with tarfelt including cement plaster from roof including parapets etc, and removing the debris to a distance not exceeding 250m complete all as specified and directed.
M&L for 40mm thick plain cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in padding (level course) on roof complete all as specified and as directed.
M&L for rendering 10 mm thick in CM (1:3) using water proofing compound as per manufacturer instruction as in roof and chajjas complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately.
M&L for priming plastered roof surfaces (Non approachable roof ) with bituminous primer @ 0.3 Kg/Sqm as per IS 3384 and providing water proofing treatment by applying 3.5 Kg/Sqm ATACTIC polypropylene (Advanced APP torch on membrane) having polyster film reinforcement stabilized with fibre glass and two coat aluminium paint over APP membrane of thickness 3mm by torch bonding complete all as specified and as directed.
M&L for water proofing treatment with APP based standard membrane over PCC padding in approachable roof with the following courses of treatment : (a) Apply bituminous primer (IS3384) @ 0.30 Kg/Sqm of the surface area including cleaning the surface complete all as specified . (b) Apply APP plastomeric bitumen based water proofing membrane polyster reinforced (3.50 Kg/Sqm) with 10 cm overlaps and torch bonded at joints including surface preparation before and after application of treatment as per manufacturers instruction complete all as specified.
Supply only water proofing compound complete all as specified and as directed.
M&L for cement concrete tiles 25cm x 25cmx22mm thick machine pressed set jointed and pointed in neat cement slurry in floors and cut polished with grey cement and no pigment over 20 mm thick screed bed in CM 1:4 complete all as specified and as directed.
S & F Powder coated (Minimum thickness 50 micron) Aluminium anodized frame work for Partition/door / windows / ventilators with one or more rebates including necessary joining cleats for fixing, glazing clips, rubber packing , anodised aluminium snap beading ,screws & anodised aluminium fittings complete all as specified and directed by Engineer in Charge.
S&F pre-laminated particle board (12mm thick) Interior grade pre-laminated both side with decorative choice laminations fixed in alluminium door or frame work with screws or necessary fittings complete etc. all as specified and as directed.
S& F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
S & F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame including beading all as specified & as directed
M& L for Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc and applying one coat of neat cement slurry @ 3.00 kg/Sqm complete as directed
M & L for brick work with Fly Ash bricks built in CM 1:4 straight or curved exceeding 6m mean radius complete all as specified and directed.
M & L for rendering 15mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces , finished even and smooth without using extra lime or cement complete all as specified and as directed
M &L for preparation of new plastered surfaces on walls and applying two coats of OBD over 3mm thick wall care putty over one coat of altek primer to obtain smooth regular/even finish using sand paper and complete all as specified and directed.
M&L Removal of existing treatment on walls and applying necessary Altek superfine 3mm thick wall care putty over one coat of altek primer to obtain smooth regular/even finish using sand paper and applying two coats of OBD of any tint complete all as specified and as directed.
S&F Powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and as directed
S&F Powder coated anodied aluminium window and ventilator shutter ,side hung type without sash bars aluminium sections weighing 0.55 kg/m including necessary joining cleats ,glazing clips rubber packing anodised aluminium snap beading ,screws,anodised aluminium fitting such as peg stays 150 mm long (1 no),hinges typeB-21 100mm long (2 nos) suitable handle (1no) complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed in panels of joineries with stainless steel wire staples complete all as specified and as directed.
S & F aluminium daco Grills (DG 104) with F section Channel complete of 4mm thick for windows of aperture 50 mm complete all as spd and directed.
S & F Door closer hydraulically regulated alluminium extruded section body designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete.
S & F brass Mortice lock 4 leavers vertical type size 100mm complete all as specified and as directed..
Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets complete all as specified and directed.
S & F 12.5mm thick gypsum board seamless false ceiling fixed with standard GI section such as channels, angles, the grid suspended with GI suspenders and cleat from the soffit of the slab with expension fasteners. Gypsum board fixed with screw to the ceiling section/grid. The board shall be 12.5mm thick and the soffit of board shall be finished with gypsum plaster and levelled to give flush look as per manufactgurers instructions including necessary cutting for light fitting and AC and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
Demolition of cement concrete in floors and pavings n.exc15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 25 mm thick plain cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as below floor finish complete all as specified.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as directed
M&L for glazed ceramic coloured tiles 450x300x7mm thick on vertical surfaces such as dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick backing coat in CM 1:4 complete all as directed
Taking out old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed.
Material and labour for brick work with bricks class designation 75, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Taking down plastering in cement mortar on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc. complete all as specified.
M&L for rendering 15mm thick on fair faces of brick works in cm 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 5mm thick in cement mortar (1:4) with WPC over a layer of 10 mm thick in CM 1:6 on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered on wall including applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Demolition of Lime concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling timber scantlings in unframed work 40 sq. cm and over in section fixed in any position complete all as specified and as directed.
S&F Rolled sections of grade Fe 410W (Gde E-250)as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets. complete all as specified and as directed
M&L for provn of false ceiling with anodised aluminium snap grid frame work with size of grid 605 x 605mm with aluminium main tee size 25 x25 x 1.6mm, cross tee of size 25 x 25 x 1.6mm and aluminium wall angle of size 25 x 25 x 1.8mm ,fixed to wall and hanging from soffits\trusses\bracking using adjustable supporting hanger with GI wire . complete all as specified and as directed
S & F 4mm thick non-asbestos fibre cement building boards fixed or laid/inserted to aluminium / wooden frame work with screws including two coats of OBD over a coat of alkali resistant primer and preparation of new surfaces of ceiling. complete all as specified and as directed.
M&L for Reinforced cement concrete M-25 Design mix (using 20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Material and labour for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed .
Demolition of Reinforced cement concrete as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F for mild steel welded wire mesh of any size or type complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed
M & L for Point wiring complete with two runs of 1.5 Sq mm copper conductor (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade confirming to IS- 694 drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories concealed in wwall /floor and fixed on ceiling/roof/truss/columns etc,including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches,sockets,fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw ,cup washer etc. complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dollyetc. complete all as specified and as directed for one light point controlled by one switch complete all as specified and as directed Note1: The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth Note2: The cutting of chases of required width and depth for conduit including plastering, painting two coats to match with the existing wall colour is deemed to be included in the rate quoted.
All as per Sl item No. 51 above but for ceiling fan point controlled by one, one way switch 5 amps complete all as specified and as directed
All as per Sl item No. 51 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on same board complete all as specified and as directed
All as per Sl item No. 51 above but for One 3 pin 5 amps socket outlet independent complete all as specified and as directed
M & L for Point wiring complete with two runs of 2.5 Sq mm copper conductor (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade confirming to IS- 694 drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories concealed in wwall /floor and fixed on ceiling/roof/truss/columns etc,including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches,sockets,fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw ,cup washer etc. complete concealed in walls and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dollyetc. complete all as specified and as directed for one 15A switch socket controlled by one switch complete all as specified and as directed. Note1: The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth Note2: The cutting of chases of required width and depth for conduit including plastering, painting two coats to match with the existing wall colour is deemed to be included in the rate quoted.
Description all as per item No 55 here-in-before but using 4 Sq mm single core copper conductor cable multistranded PVC insulated FRLS 1100 Volts grade for 6/16 Amps switch socket combination point including running of 4.00 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
S & F of Switch piano type single pole one way flush type 5 Amps capacity 230 volts complete all as specified and as directed
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and as directed
S & F of socket outlet flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts complete all as specified and as directed
S& F switch socket connection with flurh type multipurpose 2/3 pin 5 Amps 230 Volts complete all as specified and as directed
S & F of switch socket combination 5 in 1 multipurpose 3/5 pin 5/16 amps flush typewith complete all as specified and as directed.
S & F electronic type regulator single module stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified and as directed.
S & F Modular Switch 1 way 6 A, 1 Module capacity 230 Volts complete all as specified and as directed.
S & F Modular Switch 1 way 16 A, 1 Module capacity 230 Volts complete all as specified and as directed
S & F Modular Socket, 6A- 2/3 combined 2 module of capacity 230 Volts complete all as specified and as directed.
S & F Modular Socket, 6/16A- 2/3 combined 2 module of capacity 230 Volts complete all as specified and as directed.
S&F Modular bell push 6A 1 module complete all as specified and as directed.
Supply and fix Modular ceiling fan regulator 2 module step type AC 240 volts suitable for 1200/1400 mm sweep. Note : For Item No 4 to 9 :- Modular cover plate with frame, Modular Metal Flush Box and modular switches will be inclusive of rate quoted complete all as specified and as directed.
S & F of MCB SPN 6-10 A with short circuit capacity 10KA along with fixing arrangement complete all as specified and as directed.
S & F of MCB SPN 32 A to 40 A with short circuit capacity 10KA along with fixing arrangement complete all as specified and as directed.
S & F Sheet metal enclusure MCB DB SPN 4 way double door with 200A rated bus bar 240V double door with flush type locking system complete all as specified and as directed.
S & F of sheet metal enclosure MCB DB SPN 8way with 100 Amps rated bus bar 240 Volts double door with magnetic locking system complete all as specified and as directed.
S&F metal clad socket 3 pn 20 Amps industrial type with plug top and MCB SP 20 Amps all enclosed in sheet metal enclosure complete all as specified and as directed.
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.
M & L for Submain wiring with two single core 6 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up two one of 6 Sq mm copper conductor multistranded PVC insulated FRLS cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing complete all as specified and as directed. Note for item No 74 and 75 :- Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
S & F of 4 ft box type tube light fitting with LED Tube rod of 18 watt , extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete including taking down complete all as specified and as directed. Make : Phillips Cat No.BN021LED12S PSU CW GR or its equivalent in makes specified here-in-after
S & F 42 watt recess softline luminaire (2ft x 2 ft) suitable for armstrong/grid ceiling with high brightness white LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal and all including taking down complete all as specified and as directed. Make : Phillips Cat No.SC380B LED30S-6500 G5 L42W60 PSD OD or its equivalent in makes specified here-in-after
S & F of Security Light of 15 watt with single die ceramic base high power LED light source with IP66 protection,PDC housing & aesthetic finess disign and high impact resistance(IK08) toughened glass cover and street light optics for lighting of internal B2 category for outdoor lighting including GI bracket 25 mm dia having color temparature 4000K complete with necessary fixing arrangements such as nut,bolt,washers etc including taking down old unserviceable one complete as specified and directed.Make : Philips Cat No. BRP052 P LED025 CW SLMR FG S1PSU GR or its equivalent in makes specified here-in-after
S&F wall mounted LED batten of 09/10 watt with LEW lamp, extruded aluminium heat sink provided for efficient heat dissioation and integrated electroninc driver complete all as specified and as directed
M & L Rewinding of burnt ceiling fan of 1200 mm sweep motor with supper enameled copper wire of suitable size including repainting it white , replacement of sealed bearing and shaft of any make, type, model incl transportation complete all as specified and directed
S & F Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of size twin core 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular as per site requirement complete all as specified and as directed.
M & L of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on disconnection and reconneting the excluding unserviceable such complete all as specified and as directed. (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate).
BEEGEE DESIGN SYSTEMS
SAI RUPA CONSTRUCTIONS
M/S DIVIJA BUILDERS
VACON INFRASTRUCTURES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .