Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | ₹5.2 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹5.3 L+₹10,679 (2.07%)Rejected-AOC | ₹5.3 L+₹10,679 (2.07%) | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | V.PARIMALADEVI L1 | SRI DURGA CONTRACTORS L2 |
|---|---|---|---|---|---|
| 1.00 | Supply of 600mm Dia Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digitdigital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5%of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed asfollows: Meter tube (Sensor) shall be fabricated from stainless steel tube and useclass PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accridiated lab to be furnished. | 1 | no | 3,89,950 ₹4,60,141 Lowest | 3,98,000 ₹4,69,640 |
| 2.00 | Electromagnetic Flow Meter Installation Cost including Necessary Pipes and Specials and Labour charges | 1 | no | 47,500 ₹56,050 Lowest | 48,500 ₹57,230 |
Tender Value
₹5.5 L
EMD Value
₹5,500
Closing Date
23 Dec 2025, 3:00 pmClosed
The Commissioner, Tambaram City Municipal Corporat
No.01,Kalaivani street , Rajakilpakkam,Chennai-73
Supply, Delivery and Fixing of Electromagnetic Flow Meter at Radha Nagar Pump House
2025_DMA_635372_6
590/2025/E1
Open Tender
Civil Works
Works
90 days
Tambaram City Municipal Corporation
Supply, Delivery and Fixing of Electromagnetic Flow Meter at Radha Nagar Pump House
2 documents required · 2 mandatory
₹0
₹5,500
4 Jul 2026
23 Dec 2025
23 Dec 2025
23 Dec 2025
23 Dec 2025
23 Dec 2025
Supply of 600mm Dia Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digitdigital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5%of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed asfollows: Meter tube (Sensor) shall be fabricated from stainless steel tube and useclass PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accridiated lab to be furnished.
Electromagnetic Flow Meter Installation Cost including Necessary Pipes and Specials and Labour charges
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_760352.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.34 MB
BOQ_760352.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .