Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹25.5 L+₹6.0 L (30.8%)Rejected-Finance 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | L2 | Rejected-Finance Second Lowest amount quoted | |
| 3 | L3₹33.6 L+₹14.1 L (72.2%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹59,200
Closing Date
14 Jan 2021, 6:00 pmClosed
Shri B M Verma, IDSE, EE(SG)
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2020_MES_403851_1
8305/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer (East) Jabalpur
D a(ii)
6 documents required · 6 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹59,200
Yes
2 Mar 2021
15 Dec 2020
16 Jan 2021
15 Dec 2020
14 Jan 2021
31 Dec 2020
15 Dec 2020 - 30 Dec 2020
Amount
Excavation in trenches nexc 1.50 mtr wide and n exc 1.50 mtr depth for foundation etc nexc 10Sqm on plan and getting out in hard/dense soil complete all as specified & directed.
Returning, filling in, incl spreading, leveling, watering and well ramming in layers nexc 25cm thick in any type of soil complete all as specified and directed
Removing excavated material nexc 50m and depositing where directed at a level n exc 1.5m above the starting point all as specified and directed
M&L PCC (1:4:8) type D-2 using (40 mm graded stone aggregate) in foundation, filling mass concrete complete all as specified and directed. .
M&L for RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in foundation, rafts,footing, plinth beam, base for columns complete all as specified and directed.
M&L for RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in columns complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished concrete surfaces
Formwork to sides of pillars, piers, columns, square, rectangular, polygonal, circular on plan rough finished surfaces of concrete completed all as specified and directed
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe - 500 or Fe-550 complete all as specified and directed by Engr-in-Charge.
-Ditto- all as per item No 27 above but 8 mm dia and over upto and incl 10 mm dia as in stirrups complete all as specified and directed
M&L PCC (1:2:4) type B-1 (20mm graded stone aggregate) as in coping and the like including weathering, slightly rounded or chamfered angles and throating, including formwork complete all as specified and directed
M&L brick work with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in CM 1:4 all as specified and directed
M&L Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6).
M&L 15mm thick rendering on fair faces of brick surfaces in CM (1:4) finished surfaces even and smooth without using extra cement complete all as specified and directed.
M&L in repairs for precast reinforced cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate in louvres and jallies & including MS rod 6 mm dia reinforcement as per trade pattern , 35mm thick (measured solid), set in cement mortar (1:4) including all mouldings complete all as specified and directed
M&L for three coats of white wash (lime) on newly plastered surfaces on wall including preparation of new plastered surfaces complete all as specified and directed
M&L 10mm thick Screed bed or bedding layer of mortar (1:4) for laying wall finishes.
S&F coloured virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.42 sqm but not exceeding 1.00 sqm, in walls etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
S&F non skid joint free coloured ceramic tiles 7 nto 8 mm thick (Square/rectangular) area of each tiles exc 0.18 sqm but not exc 0.38 sqm in floor set and jointed in neat cement slurry and pointed in colour cement in floor/wall complete all as specified
S&F aluminium composite panel cladding with open grooves for linear as well as curvilinear portions of the building/wall for all heights and all levels etc. including: (a) Providing fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour or as approved shades made out of 3mm thick aluminium composite panel material with core sandwiched between two Aluminium sheets (each 0.25mm thick). The aluminium composite panel cladding sheet shall be coil coated with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 asspecified using stainless steel screws nuts bolts washerscleats weathersilicone sealant backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanized with serrations and serrated washersto arrest the wind load movement fasteners SS 316 Pins and anchor bolts of approved make in SS 316 Nylon separatorsto prevent bi-metallic contacts all complete required to perform as per specification of manufacturare. Including base frame work for ACP cladding of aluminium complete all as directed by the Engineer-in-Charge.
Cutting holes into or through brick walls built in cement mortar, superficial area exc150 but n.exc 400 Sqcm and making good in cement mortar 1:3 or PCC 1:2:4: type B-1 as required.
S&F stainless steel work framed such as grills,gratings etc. with ends of bars souldered or or rivetted or forged into spikes,framed guard bars,frame works of Grade-304 of any section and size complete all as specified and directed.
S&F GI frame work for seamless ceiling comprising of GI perimeter channel .55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screw at 450 mmc/c intermediate channel .9mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900 mm c/c with GI cleat and steel expansion fastner with and including ceiling (not exc. 1.2 m length) of .55 mm thickness having Kurleb web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm c/c with hangers upto 1200 mm length of GI 3.2 mm dia wire including 12 mm thick Gypsem Board joints are covered with cotton cloth tape with and including 2mm thick averaging putty and two coat oil bound distemper complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out as in hard/dense soil complete
M&L hardcore of guage not exec 63mm deposited, spread and levelled in layers not exec 15 cm thick, watered and rammed to a true surface.
M&L RCC type B1 (1:2:4) (20mm garded stone agg) as in beam all as specified and directed
M&L RCC type B1 (1:2:4) (20mm garded stone agg) as in slab supported of wall, beam snd columns in floor , roof landings all as specified and directed
Formwork to sides and soffits of floor or roof beams, beam haunchings girders, bressummers, lintels, cantilevers, shelves including supports overhangs, etc. also splays between floors and beams, etc.
Form work to soffits of suspended slabs such as roof slabs or similar work n. exc 200mm thick rough finish surfaces of concreate flat all as specified and directed.
M&L 10 mm thick cement plaster in CM 1:6 on brick wk or on concrete surface even and smooth finish w/o using extra cement all as specified and directed
M&L 5mm thick cement plaster in CM 1:3 on soffits of concrete surfaces even and smooth finish w/o using extra cement all as specified and directed
Supply only water proofing compound ISI marked
M&L 100 mm thick cement concrete type D2, 1:4:8 (40mm graded stone agg) as in sub base floor all as specified and directed
M&L 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone agg) as in path / plinth protection incl filling expansion joint with sealing compound all as specified and directed
M&L 2nd class hard wood plain, solid, straight chowkats & frames wrought framed rebated on the solid rounded or chamferred put together with glue pinned at joints complete
M&L 35mm thick (Factory made) IInd class hardwood, Plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified.
S & F 150mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed
S & F 150mm aluminium handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge
S&F 100mm long butt hinges, 'medium weight', stainless steel min 3 mm thick for doors complete of design all as directed by Engr-in-Charge
M&L 2 coat of synthetic enamel paint over a coat of red oxide on new steel surfaces incl preparation all as specified and directed
M & L preparing plastered/ unplastered new surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M&L 3 coat of white washing on new ceilings surface incl necessary preperation all as specified and directed
S&F flat iron 25x3mm, 300mm long as in hold fasts all as specified and directed
Geographical survey of ground water from any approved hydrologist agency to explore the ground water potential of the area & submitting the technical report to department giving recommendation on feasibility of tube well at particular location complete all as specified and directed.
Drlling of trial bore well 200mm dia. In any type of soil/rock by rotary fast rig method or any other approved method of depth not exceeding 80 m at alocation approved by GE based on soil investication report and disposal of waste material incl. following job comlete all as spcified & directed.
Collection of soil sample of bore at every 1m depth & submission to department with strata chart
Collection of water sample from bore well & getting them tested from chemical & bictorigical analisys from recognised institution approved by govt.
Test on quality of water for drinking purpose
All as per item no 46 Above but exceeding 80m in depth but not exceeding 175m in depth
Supply and lowering plain PVC casing pipe of outer dia 200mm , wall thickness not less than 5.7 mm conforming to IS specification complete all as specified and directed.
-Ditto- All as per item No 48 above but ribbed screen pipe 200 mm dia complete all as specified and directed.
S&F for MS reducer, bail plug, well cap, MS strip for centering, MS iron clamps, electric logging and sample strata box complete all as specified.
M&L development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water complete all as specified.
M&L yield test for the bore well by continuously pumping for 16 hours to determine safe pumping yield complete all as specified.
Supply, install, testing and commisioning, summersible pump set ,3 phase 415 AC,2900 RPM, head 126 m, discharge 240 LPM suitable for 200 mm dia bore well (Casing pipe size 200/ 250 mm dia) supplied and installed complete make KSB MODEL NO-KS6EA1515R or equivalent of JYOTI/KIRLOSKAR
Supply and lay/lower submersible cable in to bore hole along with submersible pump set flat PVC insulated and sheathed water proof flexible copper conductor 1100 volts grade of size flat 3 core 10 sq mm including all necessary jointing materials/kit and connecting up motor and starter terminals and testing complete all as specified & directed.
Supply fabricate, installation and tesing of FPB ,outdoor type 45 cm height from ground to bottom of pillar box, front door with locking arrangement with duplicate keys fixed on top hinges mounted on and including PCC foundation and connecting LT panel cubical flush pattern made out of MS sheet 2 mm with angle iron base frame of size 50mm x 50mm x 6mm for mounting of panel, dust proof, welded steel structure with locking arrangement having TPN Bus Bar 200 Amps rating capacity aluminium strip fixed with insulators 4 wire system painting of steel work with 2 coats of synthetic enamel paint over a coat of red oxide primer comprising of the following:-
MCCB TP 415 Volts 63 Amps 30 KA - 01 No. L&T CAT NO.SL98603OOOO & Havells/Crompton/ABB
MCCB TP 415 Volts 40 Amps 30 KA - 01 No. L&T CAT NO SL97205OOOO and Havells/Crompton/ABB
MCB SPN 230 Volts 32 Amps - 01 No.
Phase indicating lamp (RYB) - 01 Set.
Mini protection relay with over load range 16-44 amps L&T cat no-MPR 304 BE 160 - 1 no
Star Delta Starter ML 1.5 having all safety devices suitable upto 25 HP, 3 phase motor.
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt,Earthing lead 32x6 up to 7.5m, 20mm dia medium grade GI watering pipe, G.I. protection pipe 40 mm dia up to 7.5m long,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR Part-I 2009.
S&F 100mm bore cast iron pipes with flanged ends centrifugally cast including specials Class "B", in any length laid in trenches of size complete all as specified and directed.
M&L Cast iron fittings, bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, 'Y' junction double branch, cross (all sockets or socket and spigot ) collars, caps and plugs upto 200mm bore complete all as specified and directed.
Supply and fix CI sluice valve 100 mm dia Kirloskar/Upadhyay/L&T MAKE both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1 ISI marked complete all as specified and directed of sizes :-
Supply and fix CI double end flanged and drilled non return valve of size 100 mm dia PN-1 ISI MARKED Kirloskar/Upadhyay/L&T MAKE
M&L for GI pipe of size 80 mm bore Heavy grade conforming to IS specification suitable length 3 m each cutting threading and lowering into the bore holes complete all as specified & directed.
M & L for Heavy duty galvanized steel socket (couplings) 100 mm long for joining GI pipe in bore holes suitable for 80 mm GI pipe complete all as specified & directed.
M&L for Peg gravel of size 5mm to 8mm size of approved quality packed around the pipe complete all as specified.
S & F MS clamp made out of 50 X 6mm MS flat of size for holding 80mm dia GI tubing including nut , bolt & washer complete all as specified and directed.
M & L for plateform around borewell with PCC 1:3:6 type C2 40mm graded stone aggregade of size 1.2 X 1.2 X 0.3 m , with 2 nos GI pipe 80mm bore "medium grade" 60 cm long embeded in concrete, complete all as specified.
Supply and fix PVC pipe End cap screwed for 200 mm bore PVC pipe complete all as specified and directed.
S&F reflux valve with bypass arrangement supplied and installed complete of size 100mm (4") dia to connect pipe as requisite location and direction all as specified and directed
Removal of trial bore pipe with the help of chain pulley
S&F GI pipe 80 mm bore medium grade including cutting, threading with laid in trenches to connect supply line as per site requirement complete all as specified and directed.
S&F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of cross sectional area and size 3.5 core, 50 sqmm. note- rate is inclusive of cable gland & cable lugs
Excavation in trenches, n. exc 1.50m wide and n. exc 1.5m in depth for laying of cables, poles and stay in soft/loose soil and not exceeding 10 Sqm on plan and getting out complete all as specified.
M&L for Unwashed Sand cushioning to under ground cable provided with a layer of 8 cm thick before laying and 15 cm thick covering above the top edge of cable after laying complete all as specified.Note : maesurement shall be done after puning down of sand.
M&L for Brick covering with width equal to length of bricks as mechanical protection to cable with well burnt old size sub class `B` bricks laid dry and flat complete all as specified and as directed.
S&F 50mm bore Steel tubing GI "light grade" for cable protection passing under road /floor or for fixing to poles all as specified and as directed Make - ITC / JINDAL /ZENITH/TATA/ PRAKASH SURYA
S&F bleaching dozer bucket type of capacity 145 Ltr to mix bleaching/Altoc in water supplied through borewell in appropriate quantity all specified and directed.
S&F 25 mm bore GI tubing 'medium grade' with all fittings laid in trenches complete all as specified
S&F 50 mm bore GI tubing 'medium grade' with all fittings laid in trenches complete all as specified
S&F 40 mm bore GI tubing 'medium grade' with all fittings laid in trenches complete all as specified
S&F 25mm bore gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 50mm bore gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for the following Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS), with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS) stranded for earth continuity wire, to be drawn in and including, PVC "medium grade" conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and EBONITE switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified Make of cable - FINOLEX / PLAZA / HAVELLS & Make of PVC conduit & conduit accessories - PLAZA /FINOLEX/BERLIA. Note : (1) Making good to match with the adjoining surface shall be included in the unit rate. (2) Rate is inclusive of Cutting/chases of wall/floor/ceiling
One light point controlled by one, one way switch
One ceiling /exhaust fan point controlled by one switch and regulator
One 3 pin 5 amps socket out let point on independent board
S&F Switch piano flush type single pole one way 5 amps.
S&F Switch socket combination 5 Amps 5 pin flush type
S&F Ceiling rose, surface bakelite 65x50 mm three terminal
S&F Lamp holder insulated body with back plate for angle holder all as per specified
S&F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack, 1x16 Watt, 4 feet, surface mounting type, extruded pvc, snap on installers and domestic electronic Driver, connector block etc with all accessories intenal prewired & including conecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos etc. MAKE- BAJAJ HAVELLS/ CROMPTON
M&L for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sq mm (FRLS) , earth continuity conductor of size 4 Sq mm (FRLS) to be drawn through and including PVC conduit 25 mm dia medium grade concealed in walls/roof/floors all as directed by Engineer in Charge.Notes:- (i) Two wires of 4Sq mm and one wire of 2.5 Sq mm and one run of PVC conduit shall be measured as one unit. Make of PVC cable : Finolex/Polycab/HPL/Plaza/Havells India. Make : of PVC conduit : Kalinga/Plaza/ AKG/ Supreme
M&L for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sq mm (FRLS) , earth continuity conductor of size 4 Sq mm (FRLS) to be drawn through and including PVC conduit 25 mm dia medium grade concealed in walls/roof/floors all as directed by Engineer in Charge.Notes:- (i) Two wires of 6 Sq mm and one wire of 4 Sq mm and one run of PVC conduit shall be measured as one unit. Make of PVC cable : Finolex/Polycab/HPL/Plaza/Havells India. Make of PVC conduit : Kalinga/Plaza/ AKG/ Supreme
Supply and Fixing ceiling fans 1200 mmm ,5 STAR RATING complete including down rod,Electronic regulator 100/120 Watt step type and accessories, AC single phase 230/240 Volt of size 1200 mm sweep complete all as specified and directed. Make : Bajaj/ Havells/ Khaitan /Orient
S&F steel, tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410-SP- 55 (11.0 m long) complete all as specified. Make : Jindal/BCW Kanpur/National tubing. Note : Earth work and PCC shall be measured and paid separately.
SUPPLY & FIX LED street light of 150 Watt white with pressure die cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection complete all as specified and directed Bajaj/Havells/Crompton/ Wipro/Philips .
SUPPLY & FIX LED flood light of 120 Watt white with pressure die cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection complete all as specified and directed Bajaj/Havells/Crompton/ Wipro/Philips
Supply and fix time switches crono 24 VDC degital time switch 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure
Fabricate,supply & fix GI pipe bracket suitable for 120/150 w street light fitting, made out of 40mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt including complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core complete all as specified and directed
S&F Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 40 mm dia complete all as specified and directed Make - JINDAL /ZENITH/TATA
M&L for Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coapping of pole complete all as specified and directed
M&L for Plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation of poles etc complete all as specified.
Schedule of credit amount of Rs. 4,080.00 to be deducted during AOC
a k builders
Goodluck Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .