| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹47.7 L+₹2.0 L (4.32%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹48.8 L+₹3.1 L (6.78%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹54.5 L+₹8.8 L (19.2%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
24 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA
PROVISION OF GUARD ROOM WITH TOILET BLOCK AND MECHANICAL SHED FOR 07 HEAVY VEHICLE AND SPL REPAIR TO BUILDING NO PN 475 UNDER GE NAGROTA
2022_MES_554370_1
GEN-70/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE NAGROTA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹98,000
Yes
24 Feb 2023
26 Sept 2022
26 Oct 2022
26 Sept 2022
24 Oct 2022
10 Oct 2022
Amount
Excavating in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for foundation etc. and getting out in Sof t/ loose soil
M & L PCC 1:4:8 type D-2 (Using 40 mm grade aggregate) in foundation, filling and mass concrete
Use and waste of formwork for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces
Use and waste of formwork for sides of columns posts, struts,piers square or rectangular or polygonal rough finished surface of concrete all as specified.
M&L for form work to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, shelves,incluiding sub ports, overhangs, etc. also splays between floors and beams etc. for fair finished complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engineer-in-Charge.
M&L Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in foundation, plinth beams,footings etc,.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in columns.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in floor or roof beams
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttressescomplete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in 1:6 all as specified and as directed by Engineer-in-charge.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified.
M & L TMT bar 10mm dia and over cut to length bend to shape required indd cranking bending spirally for column, hooking ends & binding with and incld mild steel wire (annealed) not less than 0.90mm dia or securing with chips as directed
M & L TMT bar but 5mm dia and over upto and including 10mm dia in stirrups, spacers and bindersincluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip as directed
M & L for mild steel work as in grills/guard bars etc. with ends of bars shouldered or revited conforming to Fe.290.Gde-E-165 complete all as specified.
M&L rendering 15 mm thick on external faces brick /concrete surfaces other than fair faces of wall in cement mortar 1:4 rendering is to be finished even and smooth (without using extra lime or cement all as specified and directed.
M & L preparation of new decorated surfaces of external walls and applying two coat of cement base paint over a coat of primer complete as specified and directed
M&L for rendering 15 mm thick in CM 1:6 on other than fair face of brick work/ stone wall surfaces finished even and smooth with out using extra cement all as specified.
Preparing new plastered surfaces of wall and applying two coats of oil bound distemper over 1 to 2 mm thick wall care putty over a coat of primer on walls etc all as specified .
M&L for Rendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement including two coat of white wash on ceiling including preparation of surface .
M&L for glazed ceremic tiles 350x250x7 mm/450x300x7mm thick, as in dado, vertical surfaces set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 10 mm thick rendering in CM (1:4) complete all as specfied and directed.
M&L for 25mm thick PCC type BO 1:2:4 (12.5mm graded aggregate in flooring finishing rough to recieveing Top layer for flooring complete all as specified and directed.
Machine cut kota stone flooring 18-20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) (Each stone not less than 55 cms x 55 cms) complete all as pecified and directed.
Machine cut kota stone slab 18-20mm thick in skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) over 15 mm thick rendering in CM ( 1:4) including taking out of existing dado.
S & F pressed steel frames made of size 1.25mm thick MS steel for door with one or more rebates incl lugs, hold fast, lock strike plate etc complete of size 105 x 60mm including one coat of red oxide primer and PCC 1:3:6 as in back fill to chowkats all as spfd.
M&L 35 mm thick 2nd class hard wood, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), complete all as speciied.
S&F 35mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive gauge etc without sash bar but with lock rail fitted with cut and mitered beads.
Solid PVC Door Frames of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain PVC sheets for top rail lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheetto be fitted in the MS frame welded/sealed to the styles and rails with suitablePVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawings.
S & F Box type Steel ventilators top hung double shutters (inside for wiremesh & out side for glass), incl guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing.
S & F Box type Steel windows side hung double shutters (inside for wiremesh & out side for glass), incl guard10mm square bar ,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing.Steel window shall be conforming to relevant IS complete all as shown on drawing No- CEUZ/TD/1302/09 sheet No- 1/3 to 3/3 directed by Engr-in-Charge.
S&F in repair Galvanised mild wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5 m above the starting point
Returing filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick.
M&L for PCC (1:3:6) 75 mm thick Type C-2, using 40mm graded stone aggregate as in floors in bed to recive tiles /path tiles etc.
M&L for colored non skid ceramic tiles 7to 8 mm thick, area of each tile exc 0.11 sqm but n exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in colored cement over and incl 15 mm thick screed bed or bedding layers of cement mortar 1:6 to match Shade, pattern, laying etc of tiles complete all as specified and directed.
Painting two coats with synthetic enamelled paint over one coat of pink primer on new wooden urfaces of any description exceeding 10cm width/girth including preparation of surfaces
M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing with sand paper to make surface even and smooth complete all as specified
M&L for 20mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified and dirceted.
M&L for 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified.
S&F Rotational moulded polyethene water storage tank 500 ltr capacity hoisted and fixed in position including dismantling of existing tank and including PVC float valve 20 mm bore .
Cutting chases,pinning for tubing and making good to facing where required and pointing in cement mortar 1;3 ,cutting exc 10cm but n.exc 20cm girth all as specified and as directed by Engineer-in -Charge.
S&F 3 mm thick sheet glass ordinary quality glazing with steel pins,oil putty to steel windows and, beads nails etc to wooden surfaces as in square exc 0.50 sqm in each pane, all as specified. Make:Saint Gobain
S&F in repair angle valve with wall flange , cast copper alloy, chromium plated fency type screwed for 15 mm iron pipe, complete all as specified.Make :- PARRYWARE or equivalent in Jaquar/ Kohler/ HINDWARE.
S&F in repair CP Bib taps,long body, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified complete all as specified. Make :- PARRYWARE or equivalent in Jaquar/ Kohler/ HINDWARE.
S & F in repair 15 mm bore pillar taps fancy type cast copper alloy chrominium plated fancy typewith capstan heads, chromium plated, screwed down high pressure with or without lettered "Hot or Cold" with long screwed shanks and fly nuts screwed for iron pipe. Make :- PARRYWARE or equivalent in Jaquar/ Kohler/ HINDWARE.
S&F in repair Vitreous china wash down water closet white colour, Size(570x390x400) with 'S' trap, closed pattern with flat bottom, complete all as directed. Make :- PARRYWARE or equivalent in Jaquar/ Kohler/ HINDWARE.
S&F for 110mm bore Cast Iron (SWR) 'P' or 'S' trap, including fixed with solvent cement complete all as specified and directed. Make :- PARRYWARE or equivalent in Jaquar/ Kohler/ HINDWARE.
S&F in repair flush Cistern with Drainage L-Bend Pipe with Gasket & Installation Kit (Suitable for EWC), complete all as specified. Make :- PARRYWARE or equivalent in Jaquar/ Kohler/ HINDWARE.
S&F in repair 450mm Long Braided Hose with Two 15mm Nuts & Rubber Washers (Both Side) Without Nipple (Suitable for Geysers) complete all as specified. Make :- Jaquar, Cat No- ALD-CHR-805B or equivalent in kohler/ Artize.
S&F UPVC (SWR) Type-B pipes single socketed, 110 mm dia, in any length with rubber ring joints, laid in trenches or on wall complete all as specified. Make:- Astral, Supreme, Finolex.
S&F in repair Wall Hung Basin with Fixing Accessories Set, Size : 510 x 400mm, including cuppling and pvc waste pipe complete all as specified. Make :- PARRYWARE or equivalent in Jaquar/ Kohler/ HINDWARE.
S & F butt hinges of mild steel cold rolled medium weight of size 100mm as specified.
S&F Aluminium anodised, barrel tower bolts size 200 mm of extruded section and fixed complete all as specified. (ISI Marked)
S&F Aluminium handles, cast type, anodised Size-150mm, anodised section and fixed complete all as specified. (ISI Marked)
S&F Aluminium alloy, anodised, sliding door bolt Size- 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed cpmplete all as specified.
M & L for PCC 1:3:6 C-1 (using 20mm graded crushed stone aggregate) as in plinth protection ( 50mm thick ) finished even and fair all as specified.
Surface excavation no t exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil.
S & F in repair mild steel helical/ordinary rat tail rod pattern door spring 300mm including roller and roller plate complete fixed with welding all as specified. Make:- ( ISI Marked)
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) with average thickness 50 mm laid in two layers of 25 mm thickness each with wire netting of 0.60 mm dia and size of mesh 12 mm x 12 mm laid between the two layers finished even and smoothes in roof padding all as specified and as directed Note:- The wire mesh shall be measured and paid separately under the respective item below.
Supply only 25 mm size, wire netting of galvanized iron chicken mesh, 0.71 mm dia complete all as specified and directed.
Material and labour APP based polymeric membrane minimum weighing 3.5 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified laid over a coat of bituminous primer @ 0.40 ltr /Sqm & finished with applying bitumen grade 85/25 coat @ 1.2 Kg /Sqm. APP membrane shall be laid by torching with 75mm overlap in longitudinal direction and 100mm overlap in transverse direction all as directed and finished with applying one coat of aluminium paint as directed by Engineer-in-Charge and laid as per paticular specification of CA
Hard core of broken stone or boulder of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface.
20mm thick screed or screed bedding in cement mortar 1:4 as a sub base to chequred tile
Chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick , set, jointed and pointed in neat slurry in with grey cement and pigments, all as specified.
Material and labour Cement concrete 1:2:4 type B-0(12.5mm graded aggregate) in benching ,bed plates,coping,surface channel and drain and the like including weathering, slightly rounded or chamfered angles as directed including form work and finishing all exposed surfaces complete all as specified.
Precast cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover all as specifed including form work complete all as specified.
S&F 150 mm diameter Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified.
S&F On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc complete for 30 user conventional type all as specified.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80m dia X 3.0m effective depth complete all as specified.
Excavating in post holes (or similar holes) each n exc 0.5 cum including dismantling PCC including disposal of surplus n. exe 50m all as specified and directed by Engineer-in-Chrage
M&L for 100mm PCC 1:4:8 type D2 (40mm graded aggregate) in sub base.
M&L for 100mm PCC 1:2:4 type B1 (20 mm graded aggregate) on top surface and finishing surface of concrete pavements by brooming finish etc.complete.
M&L for cement concrete 1:3:6 type C2, 75mm thick (20 mm graded stone agg) as in plinth protection.
M&L for Forming contraction (dummy) joints 65 mm deep x 10mm wide, grade ‘A’ filled with sealing compound
M&L for Forming Construction joints 30 mm deep x 10mm wide, grade ‘A’ filled with sealing compound
Material and labour for factory made machine pressed precast concrete interlocking paver block and shape and size top layer with grey cement and pigment of thickness 80mm in different colour and pattern, laid over 25mm thick dry sand and joint filled with dry sand complete all as specified and as directed by Engineer-in-Charge
Demolition of cement concrete (unreinforced) ground floor and pavings n.exc 15 cm thickness (below or above ground level) and removing unserviceable material exc 100 mtr as specified
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds,mitred/stopped ends etc
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, gusset plates or flat sections) including distance pieces, cleats etc Fe 410-W (Gde E-250) quality A complete as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed
S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Demlition of cement concrete of any description and in any position not otherwise specifically provided for
Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or beddding layer of CM 1:4, 15 mm thick
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly complete all as specified for the following;- (a) One light point controlled by one switch 5 Amp.
(b) One ceiling fan/exhaust fan point controlled by one switch 5Amp
(c) One socket out let 5Amp controlled by one switch on same board.
(d) One socket out let 5 Amp controlled by one switch on independent board.
All as per item here in before but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15Amp socket out let controlled by one 15Amp switch on independat board.
S&F switch piano flush type 5 Amps single pole one way complete,
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete.
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type complete.
S&F of ceiling rose surface type 65mm x 50mm 2 to 3 terminal complete .
S&F Step type fan regulator 300 watt, 230 volts, 50 HZ, AC. Supply complete .
M&L Integrel sleek extruded batten aluminium /CRCA channel fitting with LED 18 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V 50 Hz.
S&F baton integrated LED channel of 5W, 230V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, Power Factor not less then 0.9
M&L LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz .
S&F for lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. Anchor (Penta) or equivalent model of Cona/Havells/HPL
S&F for LED bulb 7 watt complete all as specified and directed. Make Bajaj /Havells
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete.
S&F MCB DP 63 Amps 10 KA 230 volts "C" series complete
S&F MCB single pole 6 to 30 Amps 10 KA 230 volts "C" series complete
Supply and fixing Exhaust fan 300 mm sweep single phase AC 230/240V complete with louvers for wall mounting incl grouting, holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to exhaust fan incl cutting of the hole.
Supply and fixing ceiling fan 1200 mm sweep single phase AC 230/240V complete incl grouting of eyebolt of suitable size in ceiling and fixing the fan by mean of suitable sutable bolts, nuts, washers and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to fan complete.
Supply installation commissioning and testing of static storage water heater, 25 Ltr capacity 5 star rating BEE certified metallic enamel coated vertical mounting , single phase 220 volts , 50Hz complete with PVC connection of Hot & Cold pipe line complete all as specified and directed .
Supply and laying or fixing of cable 1100 volts grade cable PVC insulated aluminium conductor un-armoured of 16 Sqmm 2 core flat or circular, served with inner sheathing of pace tape and overall PVC sheathed in service connection suspended by insulated hangers not more than one Mtr apart including 4 mm dia suspension GI wire, complete all as specified and as directed by Engr-in-Charge.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. 2 core mm nominal cross section in service connections
M&L for well burned bricks , laid flat ( old size) sub class B designation '75' for cable protection copmplete all as specifed and directed.
Sand cushioning to under ground cable laid in trenches for laying of HT/LT UG cables 8 cm depth before laying the cable and 15 cm after laying and punned down to a depth of 10 cm as per MES SSR Part-I (2009) all as specified and directed. Note: Punned thickness shall be measured and paid to the contractor.
S&F of 60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The housing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters including GI bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle 120 degree, fixed with and including two Nos 25x4 mm size flat mild steel clamp made to shape and suitable size nuts, bolts and washers etc complete, all as specified and directed.
M&L LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz .
BHARTI CONSTRUCTIONS
R.K. Works
ASHWANI KUMAR KHAJURIA AND SONS
Bidder Name
BHARTI CONSTRUCTIONS
U K Engineering Works
R.K. Works
ASHWANI KUMAR KHAJURIA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .