| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC | ₹1.4 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.5 LRejected-AOC | ₹1.5 L | L2 | Rejected-AOC Not accepted |
| 3 | Not Admitted-Fee/PreQual/Technical NEAR SADHURAM SCHOOL RAGHUNATHGANJ KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | - | - | Not Admitted-Fee/PreQual/Technical EMD Not Matching |
| Sl No | Description | Qty | Unit | SREE SASTIKA BUILDERS AND CONTRACTORS L2 | KAVYA BUILDERS& CO L1 |
|---|---|---|---|---|---|
| 1.00 | Painting one coat of old wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour including clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the University Engineer. | 690 | m² | 98 ₹67,620 | 94 ₹64,860 |
| 2.00 | Removing the existing damaged polycarbonate sheet, Supplying and roofing with good quality polycarbonate sheets of 6mm thick with necessary bolts, nuts and washers etc., including cost of all materials, labour charges, conveyance charges etc., complete complying with standard specification and as directed by the University Engineer. | 61 | m² | 750 ₹45,750 | 725 ₹44,225 |
| 3.00 | Water proofing with TPO membrane - Providing and laying 1.5 mm thick TPO Membrane over old terrace having week surface/Lime mortar. The membrane is manufactured using hot-melt extrusion process for complete scrim encapsulation. It is reinforced with a strong, polyester reinforced fabric center (scrim) and a tough thermoplastic polyolefin compounded top ply and the bottom. It should have UV resistant top white colour which has a very high resistance to weather agents and UV rays. TPO membrane shall be plasticizer, chlorine & pthalate free, and should exceed/meet specifications of ASTM D6878. Membrane should be mechanically fixed to the substrate by independent plates and fasteners. TPO Roof Membrane should be lapped and seamed using hot air heat welding equipment after mechanically fastening the overlaps. Membrane should have following minimum properties, Breaking Strength min. 220lbf (976N) as per ASTM D751, Elongation break of reinforcement > 15 % as per ASTM D751, and Tear Strength 55lbf (245N) as per ASTM D751. The finished cost including surface preparation, application of TPO membrane over the 200GSM Geo- textile and termination of TPO membrane using 2mm thick aluminium strip sealing with PU sealant at the top of strip completely as per specification and as directed by the University Engineer. | 9 | m² | 1,500 ₹13,500 | 1,400 ₹12,600 |
| 4.00 | GST @ 18% | 1 | GST Amount (in Rupees) | 22,837 ₹22,837 | 21,903 ₹21,903 |
Tender Value
₹1.4 L
Closing Date
19 Jan 2026, 3:00 pmClosed
REGISTRAR
The Registrar, Bharathiar University, Coimbatore.
Painting the interior portion of Usha kirtilal mehta convention centre in Bharathiar University in connection with 40th convocation
2026_HE_643290_1
BU/UE/AEE/26D/D.No 1279-13.01.2026
Limited
Civil Works
180 days
Coimbatore
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
10 Feb 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
19 Jan 2026
13 Jan 2026
Painting one coat of old wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour including clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the University Engineer.
Removing the existing damaged polycarbonate sheet, Supplying and roofing with good quality polycarbonate sheets of 6mm thick with necessary bolts, nuts and washers etc., including cost of all materials, labour charges, conveyance charges etc., complete complying with standard specification and as directed by the University Engineer.
Water proofing with TPO membrane - Providing and laying 1.5 mm thick TPO Membrane over old terrace having week surface/Lime mortar. The membrane is manufactured using hot-melt extrusion process for complete scrim encapsulation. It is reinforced with a strong, polyester reinforced fabric center (scrim) and a tough thermoplastic polyolefin compounded top ply and the bottom. It should have UV resistant top white colour which has a very high resistance to weather agents and UV rays. TPO membrane shall be plasticizer, chlorine & pthalate free, and should exceed/meet specifications of ASTM D6878. Membrane should be mechanically fixed to the substrate by independent plates and fasteners. TPO Roof Membrane should be lapped and seamed using hot air heat welding equipment after mechanically fastening the overlaps. Membrane should have following minimum properties, Breaking Strength min. 220lbf (976N) as per ASTM D751, Elongation break of reinforcement > 15 % as per ASTM D751, and Tear Strength 55lbf (245N) as per ASTM D751. The finished cost including surface preparation, application of TPO membrane over the 200GSM Geo- textile and termination of TPO membrane using 2mm thick aluminium strip sealing with PU sealant at the top of strip completely as per specification and as directed by the University Engineer.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.98 MB
BOQ_770808.xls
BOQ • 0.34 MB