Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹25.3 L+₹48,799 (1.97%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹26.1 L+₹1.3 L (5.36%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | Rejected-Technical H NO 45 LANE NO 02 ADARSH VIHAR DEELI CHANNI HIMMAT JAMMU J K 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | - | Rejected-Technical Due to adverse remarks in WLR |
| Sl No | Description | Qty | Unit | M/S MOHAN LAL SHARMA L3 | CCC (CHOUDHARY CONSTRUCTION COMPANY) L1 | ANIKET TRADERS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick/stone masonry built in cement mortar and remove the site complete all as specified and directed. | 3 | Cum | 100 ₹300 Lowest | 322 ₹966 | 100 ₹300 Lowest |
| 2.00 | Demolition of unreinforced cement concrete in ground floors,tiles work (wall & Floors) and paving n.exc 15cm thickness (below or above ground level) and removing demolished material to a distance and depositing to the distance exceeding 50 metres but not exceeding 100 mitres where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge. | 1 | Cum | 200 ₹200 Lowest | 672 ₹672 | 300 ₹300 |
| 3.00 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, complete all as specified. | 6 | Each | 60 ₹360 | 222 ₹1,332 | 22 ₹132 Lowest |
| 4.00 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area exc 1.5 sqm not exceeding 4 square metre each, complete all as specified. | 20 | Each | 60 ₹1,200 | 272 ₹5,440 | 33 ₹660 Lowest |
| 5.00 | Taking down cement plaster/dado (terrazzo) on brick/concrete or stone walls, ceiling, etc, including raking out joints, hacking for key, scrugbbing down with water etc, complete all as specified and directed by Engr-in-charge. | 250 | Sqm | 8 ₹2,000 Lowest | 42 ₹10,500 | 11 ₹2,750 |
| 6.00 | M&L Pain Cement concrete 1:4:8 type D-2 in foundation filling and similar works (using 40mm graded crushed stone aggregate) complete all as specified and as directed. | 2 | Cum | 2,000 ₹4,000 | 282 ₹564 Lowest | 1,200 ₹2,400 |
| 7.00 | M&L Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified and directed by Engineer-in-Charge. | 3 | Cum | 4,800 ₹14,400 | 3,872 ₹11,616 Lowest | 6,000 ₹18,000 |
| 8.00 | M&L for reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for slabs supported on wall, beams and columns, in floor, roofs, landings, balconies, canopies, deck slabs and in shelves and the like ,complete all as specified and directed
Note : Reinforcement shall be measured and paid for separately. | 1 | Cum | 4,800 ₹4,800 Lowest | 4,872 ₹4,872 | 6,000 ₹6,000 |
| 9.00 | M&L for Steel reinforcement 10mm dia and over, TMT bars, cut to length, bent to shape required including, cranking, bending, spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed . | 100 | Kg | 76 ₹7,600 Lowest | 82 ₹8,200 | 100 ₹10,000 |
| 10.00 | M&L for steel reinforcement 6 to 8mm dia and over, TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed . | 20 | Kgs | 80 ₹1,600 Lowest | 82 ₹1,640 | 100 ₹2,000 |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
23 Jul 2025, 6:00 pmClosed
GE AF Jammu
GE AF Jammu AIR FORCE STATION
CA NO GE/AFJ-21/2025-26 PROVN OF AUTOMATIC BOLLARD BARRIER AT MAIN GATE AND MODERNISATION AND UPGRADATION OF PRESENT WET CANTEEN OF PCDA ARMY JAMMU UNDER GE AF JAMMU
2025_MES_716753_1
CA NO GE/AFJ-21/2025-26
Open Tender
Civil Works
Item Rate
180 days
JAMMU
As per NIT and Tender documents
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹62,000
Yes
29 Aug 2025
25 Jun 2025
25 Jul 2025
25 Jun 2025
23 Jul 2025
9 Jul 2025
Amount
Demolition of brick/stone masonry built in cement mortar and remove the site complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors,tiles work (wall & Floors) and paving n.exc 15cm thickness (below or above ground level) and removing demolished material to a distance and depositing to the distance exceeding 50 metres but not exceeding 100 mitres where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exc 1.5 sqm not exceeding 4 square metre each, complete all as specified.
Taking down cement plaster/dado (terrazzo) on brick/concrete or stone walls, ceiling, etc, including raking out joints, hacking for key, scrugbbing down with water etc, complete all as specified and directed by Engr-in-charge.
M&L Pain Cement concrete 1:4:8 type D-2 in foundation filling and similar works (using 40mm graded crushed stone aggregate) complete all as specified and as directed.
M&L Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for slabs supported on wall, beams and columns, in floor, roofs, landings, balconies, canopies, deck slabs and in shelves and the like ,complete all as specified and directed Note : Reinforcement shall be measured and paid for separately.
M&L for Steel reinforcement 10mm dia and over, TMT bars, cut to length, bent to shape required including, cranking, bending, spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed .
M&L for steel reinforcement 6 to 8mm dia and over, TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed .
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engr-in-charge.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete,Fe-290 (Gde E-165), complete all as specified. Note : Flat iron will be joint or welded ofter Demoltion of Existing RCC Pillar upto Reinforced through proper manner. all fillet s will be welded/ fixed with PCC bonding matrial for Bonding purpose and which is dirction by Engr-in Charge
M&L for PCC 1:2:4, type B-1 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
S&F anodized powder coatedto minimum thickness of powder coating 50 micron of aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc, complete in all respect as per manufacturer's instruction and including making good disturbed surfaces complete all as specified and directed by Engineer-in-charge.
S&F Powder coated/anodised aluminum American handle cast type 200mm for doors all as spfd.
S&F Powder coated/anodised 75mm size butt hinges , extruded aluminum alloy ISI marked all as spfd..
S&F Neoprene/ EPDM rubber gasket for fixing sheet glass complete all as specified.
S&F Zinc alloy rollers for UPVC/Aluminium windows all as specified.
S&F metal body concealed handle-cum -latch lock for aluminium sliding windows size 10x2.5x1.5CM complete all as specified and directed.
S&F Stainless steel (SS) 150 mm size butt hinges , extruded aluminum alloy ISI marked complete all as specified and directed by Engr-in-charge.
S&F Stainless steel (SS) 300mm long sliding door bolt with and or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn SS bolts and fixed complete all as specified and directed by Engr-in-charge.
S&F Stainless steel (SS) handle cast type 150mm collapsible type complete all as specified and directed by Engr-in-charge.
S&F Stainless steel (SS) tower bolt 100 mm long, anodised barrel tower bolts of extruded section complete all as specified.
S&F Stainless steel magnetic Magnetic catcher strong magnets to hold cabinet ,door etc section complete all as specified.
S&FAnodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge.
S&F aluminum alloy wire cloth , 0.45 mm nominal dia of wire and avg width of aperture 1.40mm and fixed with aluminum stapples all as spfd.
S&F for 5 mm thick tinted sheet glass or frosted glass whicj will be required ordinary quality and glazing with oil putty/ wooden beads with nails in square exceeding 0.5 Square metre in each pane etc complete all as specified and directed.
S&F 12mm thick toughned glass with films as in hinged doors Partations, automatic doors and similar work including all ascessories, cutting to shape , drilling holes as required including fixing with stainless steel cleasts, hinges etc for partation and door frames as per ground requirment , complete all as specified and sirected by Engr in Charge
S&F for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty fixed in repair including taking down carefully aluminium door without demaging any member/part and re-fixing the the same including easing complete all as specified and directed.
S&F MS mortice lock vertical type, 4 lever of size 100mm size complete all as specified and directed by Engr-in-charge.
M&L for Granite work 18-20mm thick (Table rubbed and polished) in cooking platforms over 10mm thick screed bed in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shede complete all as specified and directed by Engr-in-charge.
S&F Under counter basin Laguna Series Under Counter WASH Basin (White) | 350x350x160mm, Round | Ceramic Basin/Sink for Bathroom, Living Room assembly with manufacturar instruction complete all as specified. (Make :Jaquar, Cat No : LAS-WHT-91705 or equivalent approved makes. Note : Make change will be happen only when get non ability certificate in the market and futher other item will be also started when you get approval from GE.
S&F bottel trap 32mm size with 250mm and 190mm long wall connection pipes with complete all fitting asscecerise as per manufaturar instruction complete all as specifiedand directed. Make Jaquar Cat No:ALD-WHM-769L250X190 or equivalent approved makes.
S&Fin Repair PVC connections 15 mm size with PTMT nuts of length 600 mm, fixed in repairs, complete all as specified and diected by Engr-in-charge.
S&F in repair AQUAR Opal Prime Series Table Mounted Regular HOT and Cold Basin Mixer/TAP (Chrome) | TOP Lever, Brass Body Water Tap/Faucet/Cock for Bathroom/Kitchen Wash Basin | OPP-CHR-15011BPM dimention & weight (5 x 14 x 30 cm; 1 kg) complate all as specified. Make Modal No (OPP-CHR-15011BPM) Jaquar or equivalent approved makes.
Taking down steel tubing and connection 20 mm bore incl cleaning for refixing or removing from site complete all as specified and directed.
M&L for GI tubing 15mm dia medium grade galvanised with all fittings fixed to wall and floor complete all as specified and directed.
S&F in repairs 15mm dia bib tap fancy type( Long Nose) ISI Marked, cast copper alloy chromium plated with crutch or butter fly handle screwed down screwed for Iron Pipe or brass ferrule and fixed complete all as specified and dirceted.
S&F Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete all as specified.
M&L 100 mm thick, Plain cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L 20 mm thick screed bed or bedding layer in CM 1:6 finished fair and even for laying floor finishes/tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L for Virified Ceramic coloured tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
M&L for 300x450 x7 mm thick glazed ceramic tiles colored as in dado/ skirting and vertical surfaces set&jointed in neat cement slurry and pointed in colored cement over and incl 10 mm thick cement mortar 1:4 to match the Shade, pattern, laying etc of tiles as directed at site or equivalent approved makes.
M&L rendering 10mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar 1:6, complete all as specified and directed by Engr-in-charge.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces, other than fair face (without using extra cement) on walls in cement mortar 1:4 including WPC complete all as specified and directed by Engr-in-charge. Note: Supply only liquid water proofing admixture shall be measured and paid seperately
Supply only Liquid Water Proofing admixture complete all as specified and directed by Engineer-in-Charge.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints in trenches bore of pipe 110 mm with PVC clamps and saddles including taking down existing (SGSW/PVC) pipe and fittings.
S&F in repair Stack clamps 75/100mm dia for out of 50 mm by 5 mm flat iron round 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof with proper manner complete all as specified and directed.
M/L Cement concrete 1:3:6 type C2 using 40mm graded stone crushed aggregate in plinth protection, 75mm thick, finished even and smooth using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete all as specified.
M&L for 12 mm thick PVC laminated Gypsum ceiling board / tiles , 595 x 595 mm in size, fixed in ceiling with screws to frame work with Aluminium grit frame work or GI channel powder coated at bottom , frame work complete all as per manufacturer instruction & complete all as specified and as directed.
S&F for Hangers 6 mm dia GI ( up to 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 X 3 mm size 60 mm long drawing complete all as specified and as directed.
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate chann
S&F stainless steel rounded block made in round shape and cromium coated which will be match suitable for curtain rod 25mm dia fixed in repair complete all as specified and as directed.
S&F Stainless steel brackets set curtain finals with fitting accessories curtain rod holder set for doors & windows made in shape and size to hold certain rods and size of bracket 150mm for curatin rod of 25mm complete all as spd and directed by engr-in-charge.
Preparation of newly plastered surfaces two Coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a complete all as specified and directed by Engr-in-charge.
Complete removal of exisiting treatment and applying two Coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification filling gaps by putty after washing rubbing down and stopping complete all as specified and directed by Engr-in-charge.
Preparation of newly plastered surfaces two Coats overFinishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specifiedand directed by Engg-in Charge.
Complete removal of exisiting treatment old surface with complet removal overFinishing walls with Acrylic Smooth exterior paint of required shade (Two coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) filling gaps by putty after washing rubbing down and stopping complete all as specifiedand directed by Engg-in Charge.
M&L for preparation of new or previously untreated surface of wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
M&L for preparation of old decorated wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint Complete all as specified and as directed.
Removing excavated material outside the PCDA complex and deposited where directed away from PCDA complex, complete all as specifed and directed by Engr-In-Charge.
M&L for point wiring with single core FRLS PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through PVC conduit of size not less than 25 mm concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal box powder coated of suitable size with 3 mm thick laminated sheet cover for mounting switch sockets and regulators and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified.. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
(a) For one light point/fan/exhaust fan/wall mounted fan controlled by one SP switch
All as per Srl item No. 64 here-in-before but for one 3 pin 6 Amps socket outlet point on the same board with cable size 1.5 sqmm controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per item No-64 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No-64 above but for one 3 pin socket out let, 16 Amps on Independent board with the cable 2.5 Sqmm size.
5.M&L for point wiring with single core FRLS PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 4 Sq mm FRLS (Nominal area) drawn through PVC conduit concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal box powder coated of suitable size with 3 mm thick laminated sheet cover for mounting switch sockets and regulators and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
S&F socket outlet 5 pin, 6 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F socket outlet 6 pin, 16 amps (Multi pin) flush type complete all as specified and as directed by Engineer-in-Charge.
S&F switch piano flush button type 6 amps single pole one way.
S&F switch piano flush button type 16 amps single pole one way.
S & F MCB double door Distribution board, Single pole & neutral 240 Volt, 08 way, type With 200 Amps bus bar complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning,complete all as specified and directed by Engineer-in-Charge.
(a) MCB SP 5 to 32 Amp
(b) MCB SPN 40 Amp
S&F exhaust fan 300mm sweep, Heavy duty, single phase 415 volts AC 50HZ and connecting up complete including louvers and including provision of cable 3 core of size 0.5 sqmm (16/0.2mm) from ceiling rose to fan, provision of 3mm thick circular Bakelite sheet cover including writing MES No.2cm height with synthetic enamel black paint all as specified and as directed.
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 06 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in ccocealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note-Conduit will be measured and paid separately.
S&F Distribution board iron clad VTPN DB, double door with IP-30 1K-08 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar. Make-Legrand Cat pt No 5077 40 or equivalent of make L&T / Merlin Gerin multi-9 complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing cap 36 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
Supply and Install the electric water heater storage type 25 ltr capacity 5 star rated of vertical type and having the wall mounting arragement, thermostst,indicators and thermally instulated tank of glass lined inside the tank and heating element of 2KW,240 Volts 50 HZ Ac operated including fixing nut, bolts, PVC connections of size 24" (2 Nos for each geyser) with brass head with ABS plastic body with fastners grouted on the wall complete all as specified and as directed
S&F Single pole and neutral 240 Volt, enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amp ,complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing 230 volts modular kitchen chimney suitable to be fixed to any rigid vertical/surface over the cooking area in the kitchen, including brick wall demolition and making a hole and fixing of duct and repair of wall with complete mason work , inclusive of the following components:- (a) The canopy of the hood and the front panel is made out of high quqlity heat resistant and tempered glass,size 60x60 cm the body of the hood house motor,blower,lamp filter and control switches. (b) Reduction flange,which also acts as a uni-directional butterfly valve to prevent cockroaches or rats from entering into the hood area when the hood is not in use.It permits the smoke to go out of the hood. (c) The U shaped section is made of high quality mirror polished stainless steel(fitted along with the hood) for covering the housing and the suction. (d) Wall bracket to fix the hood with screws and rawl plugs. (e) Flexible and expandable aluminium hose to connect the hood to the outlet of the kitchen.Make-Elica/Faber/Glen/Hindware
Supply and install 2.0 TR/Ton hi wall split units indoor/outdoor complete with cordless remote control unit with in built Heating and cooling arrangement and digital inverter twin rotary of capacity as shown complete with outer unit mounting bracket and inlet/outlet copper pipe as required at site all as specified and directed by Engineer-in-charge.
S&F voltage stabiliser for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy class of +/- 2.5% and capacity 5 KVA all as specified and directed by Engineer-in-charge.
Supply and installation of requisite set of 4 K4 Crash rated Hydraulic blocking Bollards with controllers and logic circuits and other associated accessories like electric panel,wireless remotes,push button set,hydraulic power unit,electric wires and hydraulic hoses ,Bollard rated diameter of 223 mm and rated height of 900 mm with impact load of not less than 7.2 ton @ 48 kmper hr with 0.1 m penetration all as specified and directed. Make-Swaraj Secutech, Jadex International, Reliance Foundary
M&L for Civil work for installing each Bollard by digging holes inside cemented concrete road not less than 1200mm deep and 400 mm wider in diameter or as required at site ensuring proper depth and compaction for stability,using reinforcements if required,placing bollards in excavated holes,pouring concrete around the bollard ensuring proper compaction to avoid air gaps,finishing the surface level with the ground or slightly sloped for drainage.etc all as per site requirement and removing excess material and clean the area all as specified and directed.
M&L for Civil work for digging a drain pit/soakway or catchment pit near by bollard installation area upto 1200 mm deep and width upto 500 mm depending on drainage needs and lining the pit with geotextile fabric,placing a layer of coarse gravel minimum 150 mm at the base to aid percolation all as specified and directed.
Supply and install a mini submersible pump (water evacuation motor) of capacity 01 HP with starter by connecting a PVC discharge pipe of around 100 mm to actively remove water away from the bollard pit.Pump should be waterproof (IP68-rated) and corrosion resistant powered by an electrical connection with an auto-float switch and a non-return check valve to prevent backflow of water into the bollard pit all as specified and directed.
Supply , laying , testing & Commissioning UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core complete all as specified and directed by Engr-in-Charge.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. Note: All works will be executed upto 10m height, contractor shall be provided all scaffolding arrangements and safety measures to worker/manpower deployed without any extra cost.
ANIKET TRADERS (BID ID -3358810)
M/S MOHAN LAL SHARMA (BID ID -3360624)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .