GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
REPAIR REPLACEMENT OF FLAME PROOF WIRING AND CONNECTED ITEMS AT AF STN THOISE UNDER GE AF THOISE
2022_MES_552323_1
GEAF/T-29/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER (AF) THOISE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF Thoise
₹20,000
Yes
31 Oct 2022
17 Sept 2022
10 Oct 2022
17 Sept 2022
8 Oct 2022
24 Sept 2022
Amount
Taking down carefully existing unserviceable flame proof aluminum/copper point wiring of any description & in any position with and including existing conduit fixed on surface with and including existing junction boxes in between the point wiring complete, including making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed by Engr-in-Charge. NOTE: (i) Old existing junction boxes obtained in serviceable condition from taking down of point wiring shall be re-used in the work. (ii) Taking down / replacement of existing fittings like switches/sockets / switch fuses / tube light fittings etc. if any, shall be measured and paid for separately under appropriate item of Schedule `A'
Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade in and including stove enameled black, rigid steel conduits of size not less than 20 mm dia (Medium grade) fixed on surface of walls/ceilings as directed with all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed by Engr-in-Charge. NOTE : (i) Old junction boxes retrieved in serviceable conditions shall be re-used in the work. However, additional junction boxes, if any required, for making new point wiring other than the quantity of junction boxes retrieved from taking down of point wiring, shall be measured and paid for separately as ‘’supply only’’ under appropriate item of Schedule `A' but fixing element of any type of junction boxes new or old is deemed to be included in the rates quoted by the contractor for the above item. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A'. Copper Cable - Polycab/Havells/Finolex/L&T Steel Conduit- NIC/TATA/Jindal/Kalinga/AKG
All as per BOQ Srl item No 2.00 above but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable for 16 Amps Flame proof Switch and socket complete all as specified and directed by Engr-in-Charge.
Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade in existing conduit fixed on surface of walls/ceilings as directed and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed by Engr-in-Charge. NOTE : (i) Point wiring shall be executed with using existing conduits and junction boxes but contractor’s quoted rates for the above item is deemed to include the cost of fixing the existing conduits and junction boxes in position properly as per site requirement and as directed by the Engineer-in-Charge. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A'. Make:- Copper Cable - Polycab/Havells/Finolex/L&T
All as per BOQ Srl item No 4.00 above but point wiring for 2 light points controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per BOQ Srl item No 4.00 above but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable for 16 A Flame proof Switch and socket complete all as specified and directed by Engr-in-Charge.
Taking down carefully u/s worn out wires of sub main wiring from existing conduit and M&L for drawing new two single core PVC insulated, FRLS, stranded copper conductor cable of size 4 Sqmm for sub main wiring, along with one run of 2.5 Sqmm PVC insulated, FRLS, Stranded copper conductor cable for earth continuity conductor complete all as specified and directed by Engr-in-Charge.
Replacement of old unserviceable sub main wiring for circuit/ submain wiring alongwith earth wire with two run of 6.0 sqmm of , PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100Volts grade and one run of 4 sqmm, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, and including concealed 25 mm dia PVC conduit 2 mm thick with all fittings, ISI marked, incl. cutting chases & making good disturbed surfaces of walls , floors etc to match with existing surface complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down carefully flame proof, weather proof, toggle type switches and making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down carefully flame proof, Switch socket of any capacity and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
Supplying & fixing for flame proof push button 10 Amps in LM 6 metal enclosures complete all as specified & directed by Engineer-in-Charge. Make: cat part No PBS / OA /1010-1A of Sudhir Switchgears Ltd or equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/ Bajaj/Philips
Supplying & fixing for flame proof emergency stop push button LM 6 metal enclosures complete all as specified & directed by Engineer-in-Charge. Make: Cat part No PBS / OA /1010 of Sudhir Switchgears Ltd or equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/ Bajaj/Philips
Supply and Fixing flame proof 16A Single pole ON-OFF /rotary type switch of any description any capacity or make complete all as specified & directed by Engr-in-charge. Make: Cat Part No RI/OA/1010-2A of Sudhir Switchgears Ltd or equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/ Bajaj/Philips
Supplying & Fixing flameproof switch fuse unit in LM-06 metal enclosures, with HRC fuse double pole 16 Amps, Single Phase 240 volts complete all as specified & directed by Engr-in-charge. Make – Cat part No. SF/A/1011 of Sudhir Switchgears Ltd or equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/ Bajaj/Philips.
Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amps complete all as specified & directed by Engineer-in-Charge. Make – Cat part No. SS/OA/1010 -1 of Sudhir Switchgears Ltd or equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/ Bajaj/Philips
Supplying & Fixing flameproof distribution board 8 way single pole & neutral in LM-6 metal enclosures with and including supplying & fixing 01 No MCBs single pole and neutral 40 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified & directed by Engr-in-charge. Note: The cost of MCBs is deemed to be included in the quoted cost. Make : Cat part no MCDB-186 of Sudhir Switchgears Ltd or equivalent in Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/ Bajaj/Philips
S&F in repair flame proof point weather proof LED tube light fitting box type with 1x20 W led tube fitting including connecting electrically to ceiling using flexible 3 core PVC insulated over all sheated with flexible copper conductor of size .75 Sqmm all as required complete all as specified & directed by Engr-in-charge. Make : Havells/Bajaj/Crompton Greaves/Sudhir Switchgears/Syska/Bajaj/Philips
Supplying & fixing in repair /replacment flame proof fluorescent tube light fittings 1 x 36/40 watt as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plane washers heat resistant glass of make Borosil complete with starter, holder, choke etc & pre-wired including reflectors and wire guards and including one No fluorescent tube 40 watt, fitting fix to wall/ceiling with using old existing fixing arrangements all as specified and directed by Engineer-in-Charge. Make : Cat Part No FF/OA/1271/401 of Sudhir Switchgears Ltd/Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/Bajaj/Philips/ Havells/Syska
All as per BOQ Srl item No 18.00 above but Supplying & fixing flame proof fluorescent tube light fittings 2 x 36/40 watt with 02 Nos fluorescent tubes complete all as specified & directed by Engr-in-charge. Make :- Cat part No. – FF/0A/1271/402 of Sudhir Switchgears Ltd/Crompton Greaves/ Shyam Switchgears/ Flexpro Electricals/Bajaj/Philips/ Havells/Syska
Disconnecting and taking down and Supplying and fixing on distribution board, single pole (SP) MCB 6 to 20 Amps, 240 volts, 50 Hz, AC made from molded self extinguishing thermostat plastic and suitable for ‘ C ‘ curve, 10 KA breaking capacity complete conforming to IS : 8828 of 1996 and complete all as specified & directed by Engr-in-charge. Make : MDS/legrand/ABB /Schneider/ Havells/ Sudhir Switchgears/Shyam, Switchgears
All as per BOQ Srl item No 20.00 but Supplying & fixing MCB of double pole & current rating 6 Amps to 32 Amps complete all as specified & directed by Engr-in-charge. Make: MDS/legrand/ABB /Schneider/ Havells/ Sudhir Switchgears/Shyam, Switchgears
All as per BOQ Srl item No 20.00 but supplying & fixing MCB of four pole & current rating 63 Amps complete all as specified & directed by Engr-in-charge. Make : MDS/legrand/ABB/Schneider/Havells/Sudhir Switchgears/Shyam, Switchgears
Replacement of unservicable LED tube light fitting 18 watt incl. LED tube complete with all accessories warm/cool white internally pre- wired and incl.connecting up with twin core twisted flexible copper conductor cable of 1.5 Sqmm complete all as specified & directed by Engr-in-charge. Make: Cat Part No.LHEXCEPNUNIW020 of Hevells equivallent of Wipro/ Philips/Bajaj/Crompton Greaves/Syska/Sudhir Switchgears/Shyam Switchgears
Replacement of unservicable LED new adore of 15W B22 CDL ball lamp complete all as specified & directed by Engr-in-charge. Make: Cat Part No.LHLDEREEMK8X015 of Hevells or equivallent of Wipro/ Philips/Bajaj/Crompton Greaves/Syska/Sudhir Switchgears/Shyam Switchgears
Replacement of unservicable LED new adore of 07W B22 CDL ball lamp complete all as specified & directed by Engr-in-charge. Make: Cat Part No.LHLDERUEML8X007 of Hevells or equivallent of Wipro/ Philips/Bajaj/Crompton Greaves/Syska/Sudhir Switchgears/Shyam Switchgears
Replacement of unservicable switch piano type 5 A flush button single pole one way complete all as specified & directed by Engr-in-charge.
Replacement of unservicable switch socket combination,outlet, 2 pin 5 Amp/ 3 pin 5 Amp flush type multipurpose complete all as specified & directed by Engr-in-charge.
Replacement of unservicable switch socket outlet suitable for inserting 2 pin 5 Amp/ 3 pin 15 Amp plug top flush type multipurpose complete all as specified & directed by Engr-in-charge.
Supply and fixing flexible metal conduit (Bend, Elbow, Tee) flame proof complete all as specified & directed by Engr-in-charge. Make: Bajaj /SUDHIR/NIC/Jindal/Kalinga.
Supply and fixing connecting metal conduit flame proof complete all as specified & directed by Engr-in-charge. Make:- Bajaj /SUDHIR/NIC/Jindal/Kalinga.
S&F in replacement of porcelain lamp with complete fitting suitable for HPMV/ HPSV lamps complete all as specified and directed by Engr-in- Charge. Make - Bajaj/ Sudhir/ philips/Havells/Syska/Crompton Greaves
S&F in repair open construction HPSV/MH Ballast copper wound 150 watt suitable for 150 watt HPSV/MH fitting complete all as specified & directed by Engr-in-charge. Make :- Bajaj Catpart no - BJOS150 SV/MH or equivalent in Bajaj/Havells/Syska/Crompton Greaves.
S&F in repair Igniter suitable for HPSV/ MH lamp fitting of cap 70/ 150/ 250 watt complete all as specified & directed by Engr-in-charge. Make :- Bajaj Cat part No - BJIGN HPSV1 or equivalent in Bajaj/Havells/Syska/Crompton Greaves.
M/S V K TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .