| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹41.8 LAccepted-AOC WARD NO 09 NEAR CHHATRABAS PRATHVIPUR DIST NIWAR MP PIN 472338 | PRATHVIPUR | NIWAR | MP | 472338 | 1st | Accepted-AOC The lowest bidder M/s Shubh Construction is being accepted please. | |
| 2 | 2nd₹43.8 L+₹78,207.46 (1.82%)Rejected-Finance | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹44.1 L+₹1.1 L (2.46%)Rejected-Finance | 3rd | Rejected-Finance L3 | |
| 4 | 4th₹45.6 L+₹2.6 L (5.99%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | 4th | Rejected-Finance L4 | |
| 5 | 5th₹46.7 L+₹3.7 L (8.51%)Rejected-Finance | 5th | Rejected-Finance L5 |
Tender Value
₹48.8 L
EMD Value
₹97,600
Closing Date
8 Oct 2024, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
SPECIAL REPAIR TO BLDG NO ASC-5 (FRESH ISSUE SHED) AND SPECIAL REPAIR OF PERIMETER WALL WITH FENCING FOR 560 RUNNING METER FROM CORNER OF BLDG NO ASC -17 TO JCOS OTM ACCN AND PROVN OF CHAIN LINK FENCING OF LPG STORAGE SHEDS WITH GATE AND ENTRANCE PAT
2024_MES_666523_2
8755 GE(AWC) /MHOW / OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE AWC MHOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹97,600
Yes
29 Nov 2024
17 Sept 2024
9 Oct 2024
17 Sept 2024
8 Oct 2024
25 Sept 2024
Amount
Dismantling of Asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings complete all as specified and directed.
S & F Pre-painted galvalum aluminium zinc coating steel based corrugated steel sheet 0.50mm thick (total coated thickness) of any colour having tensile strength of 550 Mpa minimum, yeild strength, it shall be coated with hot dip alloy of 55% aluminimum, 43.5% zinc,1.5% Silicon and finished with resin coat on both surface @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprened and EDPM washers as in roof covering all as directed at site all as specified and dircted. Note- Fixing of sheet can be done in any shape( round/semicircle etc)
S & F Pre-painted galvalum aluminium zinc coating steel based plain steel sheet 0.50mm thick (total coated thickness) of any colour having tensile strength of 550 Mpa minimum, yeild strength, it shall be coated with hot dip alloy of 55% aluminimum, 43.5% zinc,1.5% Silicon and finished with resin coat on both surface @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprened and EDPM washers as in ridges, all as directed at site all as specified and dircted. Note- Fixing of sheet can be done in any shape( round/semicircle etc)
Dismantling wrought iron or mild steel work of any description as provided for Roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I . S 1161-1979 GDE ST 240.
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W(Gde-E- 250)quality-A complete all as specified and directed.
M & L for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over of redoxide zinc chrome coat complete all as specified and as directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillet complete.
M&L Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) complete all as specified.
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. complete all as specified.
M& L for chicken wire mesh 28 guage for fixing in GI frame work of PoP ceiling complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls, ceiling etc including rakking out joints , hacking for key , scrubbing down with water at any height etc all as specified and as directed.
M&L for rendering in cement mortar (1:6) 10mm thick first coat on fair faces of brick walls or concrete surfacesand in cm 1:4, 5mm thick second coat over first coat , mixed with water proofing compound as per manufacturer instructions, finishe fair and even without using extra cement all complete as specified and as directed.
M & L 10 mm thick rendering in cement mortar 1:6 on brick work or concrete surface, surface finished even and fair complete.
M & L Preparation newly plastered surfaces and applying 1mm thick Wall care putty on surfaces of wall as per manufacture's instruction complete all as specified and directed.
M & L for applying two coats of oil bound distemper over a coat of primer on prepared wall putty surfaces of internal wall all as per specified and directed.
M&L Two coats of exterior emulsion paint ( Apex ultima or weather coat) with primer , white or tinted on old/New surfaces of walls including prepration of old/New surfaces and washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed
M&L Granite stone 18- 20 mm thick(of any type) work (table rubbed and polished) for wall lining (Veneering to wall) and laid on cill of parapit wall over 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite colour as per direction of GE
M & L 20 - 25 mm thick machine cut Kota stone slab in flooring or treads of steps over and including 20mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing complete all as specified and as directed. Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size, except the location where the balance portion remain less than size as specified above.
Description same as per item No 21 above but as in skirting or vertical surfaces including 10 mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) and rubbish of the premisses complete all as specified and directed.
M & L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed in cement mortar 1:4 complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavigns not exc.15 cm thickness. (Below or abve ground level), complete all as specified and as directed.
M&L 75mm thick PCC type C-2 (1:3:6) (using 40 mm graded crushed stone aggregate) as in plinth protection laid in panels, finished even and fair, complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 using (40 mm graded stone aggregate) as in foundation, sub base / mass concrete etc. complete.
M & L 25 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including finishing surface of concrete topping even and rough complete as in levelling work etc complete all as specified and directed.
Demolition of Brick work built in cement mortar including all quoins arches pillars etc complete all as specified and directed
M&L brick work with fly ash brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down shutter of any description n. exc. 1 Sqm each complete.
Taking down shutters exc. 1.00 Sqm but not exc 2.0 sqm complete all as specified and directed.
S & F powder coated aluminium ventilator cross section conforming to IS 63.5x38.10x1.5mm consisting of two partions upper portion shall have louvers with 3mm thick pin headed glass and aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56m fixed with aluminium beads and securing on outer face of frame and lower portion of ventilation shall be fixed with 3mm thick pin headed glass with IDPE rubber gasket including aluminium beads, including preparation of jombs all around in CM 1:3 finishing even and smooth complete all as specified and directed.
S & F Powder coated aluminium sliding glazed windows with three track shutter sliding (two shutters glazed and one shutter wire mesh) shall be following specification complete all as specified and as directed by Engr-in-charge. (i) Windows frame of cross section 101mm x 44mm x 1.5mm thick. (ii) Three way track for sliding shutters of cross section 91.8mm x 31.75mm x1.1mm thick. (iii) Sliding shutter frame of cross section 40 x 18 x 1mm thick. (iv) 4 mm thick tinted glass superior quality. (v) IDPE Rubber guasket for fixing of glass. (vi) Locking cleats per shutter -01 Nos. (vii) Sliding rollers per shutter - 02 Nos. (viii) Aluminium wire cloth 0.30mm nominal dia of wire and average width of aperture 1.56mm for shutters 01 Nos.
S&F in repair of 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall / floor with clip complete all as specified and directed..
S & F in repair 110 mm dia bore PVC (SWR) bends with acess door any radius with solvent rubber ring joints, fixed complete all as specified and directed.
S & F in repair 110 mm dia bore PVC (SWR) junction single, single (T) equal or unequal with acess door with solvent rubber ring joints, fixed complete all as specified and directed.
M & L for complete removal of existing treatment on walls and evenly applying two coat of oil bound distemper with roller over and including a coat of putty all as specified and directed.
Material & labour preparation of old surface and applying two coats of 100% Premium arcylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade (Company Depot Tintd ) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including a coat of putty complete.
M & L for RCC M-25 (Design Mix) for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for RCC M-25 (Design Mix) for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed.
Ditto as item no.44, but 5mm dia and over upto and including 10mm dia in stirrups, spacers,distribution and binders scomplete all as specified and directed.
M & L for transparent hinged type toughned glass door having glass thickness 10mm, with swing arrangement including all necessary fittings complete all as specified and directed.
M & L for honeycomb type PVC blinds with manual folding arrangement including all necessary fittings complete all as specified and directed.
M&L 600x600x4 mm thick HPSC oceanic pre primed self embossed textured designer board water , termite and fire resistant as in ceiling or wall panelling fixed with screws as per manufracture instructionsincluding dismantling complete all as specified.
S&F 605X605mm GI snap grid frame work for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified.
M&L brick work with sub class 'B' modular brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 but except bricks, obtained from dismantling complete all as specified and directed. Note:- Bricks from dismantling shall be reused.
M & L 15 mm thick rendering on brick work or concrete surfaces in cement mortar 1:4, surface finished even and smooth without using extra cement and including taking down cement plaster any description on brick or stone wall complete, all as specified and directed.
M & L 15 mm thick rendering on brick work or concrete surfaces in cement mortar 1:4, surface finished even and smooth without using extra cement complete, all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section,Posts embedded in including taking out embedded portion and making good disturbed ground Concrete, brick work, masonry,etc complete.
M&L for mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete.
Demolition of Concrete(reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Use and waste for Form work to sides of columns and similar work with fair finished surface complete all as directed.
M&L RCC M-25 (Design mix) (20 mm graded aggregate) in Columns, pillars, piers, posts and struts complete
S & F in repair of Galvanised. 2 strands, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
All as per item No 58 above but except repairs
Cutting holes in brick walls built in cement mortar or cement lime mortar for inserting holdfast exc half brick but n.exc. one brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B1 as required.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface etc complete.
M&L for Cement concrete Type C-2(1:3:6) as in in foundations, filling and mass concrete using 40 mm graded stone aggregates etc complete.
S & F for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long & dia of neck 11 to 15 mm complete.
Supply of chain link fencing including line wire any mesh size and any type of standard rails staining bolt etc including provision of binding wire etc complete.
Fixing of chain link fencing including line wire any mesh size and any type of standard rails staining bolt etc including provision of binding wire etc complete.
Excavating over areas, n exc 1.5 m deep and getting out in hard dense soil complete all as specified and directed.
S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling rose, pendent, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down ceiling fan/ exhaust fan/ wall fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of concerned AGE E/M complete all as specified and as directed.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down old / unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Point wiring with 1.5 Sqmm (nominal cross sectional area ), single core, PVC insulated with multistranded PVC unsheathed FR LSH copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked complete , including one continuity earth wire of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area ) FR LSH copper conductor connected to all fittings, common earth and connected to earth dolly including including modular metal flush box , cover plate and cover frame of suitable size incl blank plate and making good disturbed surface of walls and floors etc. complete all as specified and directed for the following:-
(a) One light / fan /bell controlled by one, one way switch 5/6 Amps
(b) One 3 pin, 5/6 amps socket outlet point on independent board controlled by one, one way 5/6 amps switch
(c) One 3 pin, 5/6 amps socket outlet point on same board controlled by one, one way 5/6 amps switch
Point wiring with 2.5 Sqmm (nominal cross sectional area ), single core, PVC insulated with multistranded PVC unsheathed FR LSH copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked complete including one continuity earth wire of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area ) FR LSH copper conductor connected to all fittings, common earth and connected to earth dolly for one three pin 15/16 amps socket out-let point on an independent board including modular metal flush box , cover plate and cover frame of suitable size incl blank plates and making good disturbed surface of walls and floors etc. complete all as specified and directed
S&F Ceiling rose three terminals surface bakelite type, AC, 50 HZ, 230V
S&F modular switch 1 way 6 A , 1 module complete all as specified and directed.
S/F modular socket 6 Amps 2/3 pin combined 2 module complete all as specified and directed.
S/F switch modular type 16 A, 1 module complete all as specified and directed.
S/F socket modular type multipurposes 6/16 A, 2 module complete all as specified and directed.
S/F modular bell push type 6 A ,1 module complete all as specified and directed.
S/F bell multi music type AC 230 volts single pole complete all as specified and directed.
M&L for fan regulator modular step type 2 module complete all as specified and directed.
Supply and fixing surface /wall mounted LED batten poly carbonate housing for retrofit LED tube T-8 type upto 1x20 watt, 4 feet long pre wired incl integrated electronic driver complete with all connected accessories all as specified and directed.
Supply and fixing retrofit LED tube T-8 type 1x20 watt, 5700 to 6500 K and THD less than 15% , polycarbonate body ,glass tube 4 feet long complete with 02 years warrenty all as specified and directed.
Supply and fixing wall mounted LED tube light fitting 10 watts comprising batten of extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 10 W LED 2 feet long ,THD less than 15% complete all as specified and directed.
M&L for LED Bulk head fitings 6.5 watts designed for modern homes available with premium quality diffuser for glarefree light and easy to install snapfit installer complete including taking down of old CFL/bulb bulk head fitting, making good of surfaces all as specified and directed.
S & F LED bldg security light fitting 30 watt made up of pressure die cast aluminium housing with acylic cover as diffuser with IP-66 protection complete all as specified and directed.
M&L for surface mounted LED fitting 34/36 watts, 2'x2' fittings suitable for RCC ceiling, lumen out put ≥110 lumen/watt ,THD less than 10% environmental friendly, new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source,incl inbuild drivers suitable for Grid ceiling complete with atration of aluminium frame work wherever necessary during installation all as specified and directed.
S&F MCCB ,DB VTPN wall mounted double door 4 way 415 volts with facility to provide MCCB 3 pole 125 Amps 25 KA as incomer and SP/TP MCB's/Isolator as outgoing including removed old U/S DB in the wall again fixing the new DB and wall finising complete all as specified and as directed.
S&F MCB DB SPN 8 way double door with 200 Amps rated bus bar ,230 volts, 50 Hz complete all as specifed and directed.
S&F MCCB 3 pole 415 V 125 A Hz with rupturing capacity 25KA.
Supply & Fix MCB SPN 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.
Supply & Fix MCB SP 6 to 32 Amps current rating 'C' series 10 KA breaking capacitycomplete all as specified and directed.
Supply and fixing TV socket outlet complete all as specified and as directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq. mm nominal area and drawing into suitable size of PVC FRLS non metallic rigid heavy duty conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 Sqmm cable, one run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq. mm nominal area and drawing into suitable size of PVC FRLS non metallic rigid heavy duty conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 Sqmm cable, one run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit
S&F exhaust fan non metalic single phase 230 volt of size 250 mm sweep with louver all as specified and as directed.
M&L for painting of ceiling fan 1200 mm sweep complete with synthetic enamel paint by spraying , filling cavities with filler, one coat after cleaning all dust incl hanging into its original position, changing of conopies,connection wires ,round plates all as directed.
S&F in replacement of exhaust fan , steel body AC single phase 230 volt of size 300 mm mm sweep complete with blade, frame and louvers all as specified and directed incl making/alteration of hole wherever necessary making good disturbed surface, painting to match with existing surfaces.
Supply , fixing rigid non metallic PVC conduit fixed conceiled/on wall wherever necessary with all connected accessories 20 mm dia for cable TV connections complete all as specified and as directed
S&F fan regulator stepped electronic, modular type 02 module as specifed and directed.
M&L for Single pole and neutral enclosure with a two pin and earth plug and socket 240 Volts complete with one single pole MCB 20 Amps conceiled all as specified and directed
M&L for Triple pole and earth enclosure with a three pin and earth plug with socket 415 Volts, 50 Hz complete with one triple pole MCB TP 32 Amps, and of the same make as above item complete all as specified and directed.
Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 3, connected to earthing test point complete including testing on completion all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cable etc. n exc 1.5 m in depth and getting out
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm
Supply and laying river sand for cable protection in layers incl punning all as specified and directed. Note : Thickness after punning down shall only be measured.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core in trenches / under PCC/interlocking tiles incl making good of surface with PCC/ cementing incl connecting to existing LT panel board and VTPN DBs all as as directed at site
M&L for Tubes, 'light grade,galvanised, with all fitting of size 40 mm ;laid in trenches for cale protection all as specified and directed
J B CONSTRUCTION AND DEVLOPERS (BID ID -3123657)
RK CONSTRUCTION (BID ID -3131967)
sunway associates (BID ID -3131966)
APconstruction (BID ID -3132658)
Ms Ajay Builders (BID ID -3122616)
Goyal Construction (BID ID -3132870)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .