| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹14.9 L+₹78,663.20 (5.57%)Rejected-Finance WZ 61A 14 PANKHA ROAD VASHIST PARK NEW DELHI SOUTH WEST DELHI DELHI 110046 | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹15.7 L+₹1.6 L (11.4%)Rejected-Finance GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹15.8 L+₹1.7 L (11.7%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹16.8 L+₹2.7 L (18.9%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
18 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
MAINT AND REPAIR OF INTERNAL ELECTRIC SUPPLY AND CERTAIN ELECTRIC WORKS OF DAV JCDA AREA UNDER GE AF SUBROTO PARK
2024_MES_656776_1
GE/SP/TOKEN-96/2023-24
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Subroto Park
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹70,000
Yes
25 Jul 2024
30 May 2024
20 Jun 2024
30 May 2024
18 Jun 2024
13 Jun 2024
Amount
Taking down carefully copper/aluminium point wiring( light ,fan, socket or power) complete, fitting such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20 mm including conduit fittings and accessories concealed in wall / ceiling wiring on ceiling /wall terminated in flush metal box alongwith outer cover plate for mounting modular/piano switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. For One light point controlled by one switch one way.
All as per srl item 2 above but for one ceiling fan / Exhaust fan point controlled by one switch regulator.
All as per item No 2 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
All as per item No 2 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 2 above but for Call bell controled by one push button in indipendent board .
All as per item No 2 above but with 2.5 Sq mm cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
M&L for point wiring for one light fitting / one fan point controled by one switch with 1.5 Sq mm PVC insulated copper conductor cable drawing in and including PVC Casing/capping or surface conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly with 3mm thick plastic laminated sheet cover complete for one light point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 8 above but for one fan point controlled by one switch through regulator.
All as per srl item 8 above but for one 5 pin 5 amps socket outlet on the independent board.
All as per item No 8 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 8 above but with 2.5 Sqmm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
M&L for point wiring with 1.5sqmm PVC insulated unsheathed multi stranded copper conductor cable drawing in existing steel/PVC conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly excluding 3mm sheet metal box and hylam sheet complete for one light point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 14 above but for one fan point controlled by one switch through regulator.
All as per srl item 14 above but for one 5 pin 5 amps socket outlet on the independent board.
All as per item No 14 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 14 above but with 2.5 Sq mm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
S&F in replacement switch piano, flush type single pole, one way, 6 Amps, 240 volts all as specified and directed by Eng-in-charge.
S&F in replacement Socket outlet 2 in 1, 3 pin,6 A, 240 volts all as specified and directed by Eng-in-charge.
S&F in replacement switch piano, flush type single pole, one way, 16 Amps, 240 volts all as specified and directed by Eng-in-charge.
S&F in replacement socket 16 Amps, 2 in 1, flush type all as specified and directed by Eng-in-charge.
S&F in replacement Fan Regulator step type 120 watt, 240 volt complete.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular switch 2 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 16A 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular bell push 1 Module 5 Amps suitable for 240 volt Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,2 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,3 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,4 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,8 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 3 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 4 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed by Eng-in charge
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. complete With all accessories all as specified and directed by engineer-in-charge.
Supply & fix in replacement of Casing capping double lock type supper quality size 20 mm width ISI marked with fixing accessories complete all as specified and directed by Engineer in Charge.
Cutting grooves in brick wall, 75 mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3
Taking down of LED/Tube light fitting of any type of make and removing material to store for keeping in safe costudy or for reuse or taking credit and making good distrub surface of walls,floor etc complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fix in repair/replacement of old poles with new designer poles for Garden/street light made of cast iron pole with galvinised steel tube in polyster/PU paint with bracket of 3.5 Mtr height double arm of make halonix model no HOP-CID-3.5M including cement concrete 1:2:4 type B1 for Foundations up of size 1'x1'x1' PCC from ground level with proper fixing arrangements such as Nut/bolts/washers over PCC work all as specified and directed by Engineer-in-Charge.
Supply and fix 1x50Watt 22 Cool white LED bulb suitable for decorative cast iron pole of make Halonix 50W B22D LED Cool White bulb model No (F4IMNB5P9000000) all as specified and directed by Engineer-in-Charge.
Supply and fix 1x40Watt 22 Cool white LED bulb suitable for decorative cast iron pole of make Halonix 50W B22D LED Cool White bulb model No (F2MMNN4EP9000000) all as specified and directed by Engineer-in-Charge.
M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 1000 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories:- INCOMING (a) ACB 800 Amps, 400Amps, 50KA drowout version of cat No 669540 - 01 Nos (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01. (d) LED type indicator lamp set of red , yellow and blue - set 01 OUT GOING (a) MCCB 320 Amps, 4 pole, 36 KA - 02 Nos (b) MCB 250 Amps, 4 pole, 36 KA - 02 Nos (c) MCB 200 Amps, 2 pole, 36 KA DPX3 63 - 01 Nos (d) MCB 160 Amps, 2 pole, 36 KA DPX3 63 - 01 Nos
M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 300 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories:- INCOMING (a) MCCB 400 Amps, 4 pole,36 - 01 Nos (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 OUT GOING (b) MCCB 200 Amps, 4 pole, 36 KA - 3 Nos (c) MCCB 200 Amps, 4 pole,25 KA - 02 Nos
M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 400 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories:- INCOMING (a) MCCB 400 Amps, 4 pole,50Hz, 415 volt with rupturing capacity 36ka - 01 Nos (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 (e) Mannual 320 Amps change over - set 01 OUT GOING (a) Timer switch 3 pahse of make Havells/ swadeep/C&S etc - 01 Nos (b) MCCB 125 Amps, 4 pole, 16 KA - 3 Nos (c) MCCB 100 Amps, 4 pole,35 KA - 03 Nos
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
S&F in repair 4mm dia GI wire completed all as specified and directed by Engr-in-charge.
Material and labour for galvanised iron strip 25 X 4 mm with saddles and fixing screws and connected as per site requirement comlete all as specified and as directed by Engineer-in-Charge.
Disconnecting,removing & taking out faulty U/G cable off sizes from trenches,wall and ducts complete all specified and as directed
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 300 sqmm x 3.5 core copmlete all as directed by engineer-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core comlete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out copmlete all as directed by engineer-in-charge.
Returning filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm in hard/dense soil copmlete all as directed by engineer-in-charge..
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point copmlete all as directed by engineer-in-charge.
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable copmlete all as directed by engineer-in-charge.
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable copmlete all as directed by engineer-in-charge.
M&L for providing cement concrete type B1, 1:2:4 using 20 mm stone aggrigate in foundation, roof,kerb or mud stops, rounded or chamfered on edges complete all as specified.
Material and labour for cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge.
S&F wall mounting fan 400 mm sweep 230 Volt, rated motor speed not more than 1400 RPM, pull cord type 3 step regulator, pull cord type oscillation and mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified.
S&F wall mounting fan 250 mm sweep 230 Volt, rated motor speed not more than 1200 RPM, pull cord type 3 step regulator, pull cord type oscillation and mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified.
S&F Exhaust fan steel body AC single 300 mm sweep 230 Volt, 1400 RPM with louver including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling fan heavy duty 1200 mm sweep, 230 Volt including necessary fixing arrangement for proper fixing/hanging as per site requirement complete all as specified and as directed by Engineer-in-Charge.
M & L for submain wiring with two run of single core 10.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 10.0 Sqmm single core and one run of 6.0 sqmm single core cable.
M & L for submain wiring with two run of single core 6.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 6.0 Sqmm single core and one run of 4.0 sqmm single core cable.
M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 6.0 Sqmm single core and one run of 2.5 sqmm single core cable.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'A' frame MCCB of 250 Amps =01 No and MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge. Make - Havells, pollycab/Indoasian.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing 415V 10KA 'C' curve TPN 16 To 32 AMP miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Taking down unserviceable SP/SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply,complete all as specified.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
R C Sharma and Co
AMIT ENTERPRISES
Laxmi traders
M/S MG GROUP
J.P. Enterprises
Vijeta Solutions
M/S ANIL KUMAR
Ashish Sehgal and Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .