| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11,219Accepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹12.5 L+₹1.2 L (10.4%)Rejected-Finance 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹13.7 L+₹2.4 L (21.1%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
20 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT , LUCKNOW
REPAIR/MAINT TO LT EQUIPMENTS PANELS AND OTHER ASSOCIATED WORKS AT AF STN BKT
2023_MES_605186_1
8725/BKT/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) BKT
₹40,000
Yes
28 Mar 2024
23 Jun 2023
22 Jul 2023
23 Jun 2023
20 Jul 2023
6 Jul 2023
Amount
Draw out & dismantling Air circuit breaker 415 Volts, AC 3 Phase 1250 Amps, carring out servicing and replacement of defective parts as mentioned below and refitting in same position and testing complete. (i) Carring out servicing of electrical and mechanical mechanism by manufacture rep of ACB by cleaning lubricating, grinding and tightening and making the system functional and testing functionality complete in all respect. (ii) Replacement of unserviceable parts in ACB:-- Electronic triping coil,closing spring, breaker coil, Under voltage relayand charging indicator. Note :- Major spare will be measured & priced seperately
Triping Coil
Closing Coil
LED Charging indicator
Under voltage relay
closing spring
Fixed copper conductor
Moving copper conductor
Taking out old serviceable /unserviceable under ground cable from trenches/poles /pipe/floor of size 16 Sqmm 3.5/4 core to 35 Sqmm 3.5/4 core complete all as directed.
Ditto- to item No 10 above but of size 50 Sqmm 3.5/4 core to 120 sqmm 3.5/4 core
Reuse and laying only old cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm to 35 Sqmm 3.5/4 Core all as specified and directed.
Reuse and laying only old cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm to 120 sqmm 3.5 Core all as specified and directed.
Supplying , laying in trenches/fixed to wall/ drawn in pipe/duct/laid in floor connecting and testing UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade (Note:- Excavation , Earth Work pipe etc will be measured and paid sepretaly) XLPE Cable of size 35 Sqmm,3.5 Core complete all as directed.
Ditto- to item No 9 above but XLPE Cable of size 95 Sqmm, 3½ Core .
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc complete all as sepecified and directed.
Returning filling in, soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm.
Removing surplus excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and directed. (Note:- punned thickness shall be measured only)
Supply and laying well burnt sub class ‘B’ bricks, locally best available laid in trenches for protection of underground cable complete all as specified and directed.
M&L for drilling hole under hard standing /road in different locations as per site requirement (between 03 mtr to 12mtr maximum) for laying of pipe, for protection of cable etc by means of mannual bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified.
Supply and laying GI tube light grade 80 mm bore (ISI marked) complete for protection of cables etc complete all as specified and directed.
M&L for heat shrinkable jointing kit of 1.1 KV grade 25 Sqmm to 50 Sqmm x3.5 core XLPE cable including suitable size of connector complete all as per directed by Engr-in-charge. including necessary excavation and earth work , labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault location all as specified and directed. MAKE:- M-seal, Raychem, CAB Seal, Denson.
All as per item No 16 above but for XLPE Cable of size 70 sqmm to 120 Sqmm x 3.5/4 core
M&L for load balancing of Single/three phase system at LT Panel upto Distribution box of any size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium tube terminal of any size and capacity all as specified and as directed by Engr-in-charge.Note : (i) Necessary equipment and safety measures reqd for load balancing shall be arranged by the contractor without any extra cost. (ii) Cost of New aluminium tube terminal of any size as per site requirement under the job shall deemed to be included in the quoted rate
Servicing and repair / maintenance of LT panel Board including checking of MCCB,s, Bus bar , cable lugs, voltmeter, ammeter and CTcoil etc for healthy operation and repairs / replacement of MCCB, BUS bar, Voltmeter, Ammeter ,Current Transformers (CTs) and replacing of defective control wiring if any replacement of defective cable lugs and complete for Indoor type / Outdoor type LT Panel of various capacity including necessary addition/ alternation of panel including cutting/welding/hinges of front and back side of panel board /feeder to match the existing panel board/feeder Note:- Major spares like MCCB, Volt meter, Ammeter, Busbar and CT's, Epoxy insulator will be measured and paid seperately.
S&F in repair of MCCBs thermal magnetic including necessery fixing arrangement complete all as specified and directed, of capacity 100 Amps, 4 Pole, breaking capacity 25KA .
All as per item No 29 above but 160 Amps, 4 Pole, breaking capacity 36 KA .
All as per item No 29 above but 200 Amps 4 Pole breaking capasity 36 KA .
All as per item No 29 above but 250 Amps, 4 Pole, breaking capacity 36 KA .
All as per item No 29 above but 400 Amps, 4 Pole, breaking capacity 50 KA .
All as per item No 29 above but 630 Amps, 4 Pole, breaking capacity 50 KA .
S&F LT volt meter (0-500) digital square, flush type of size 96x96 mm including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable Volt meter complete all as specified and directed. MAKE:- AE/L&T/Havells/Crompton.
S&F 1100 Volts grade LT Ammeter (0 - 500 A) digital square, flush & CT type including necessary addition/ alternation of panel including cutting/welding/hinges of front and back side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete all as specified and directed. MAKE:- AE/L&T/Havells/Crompton.
S & F of LT epoxy insulator for suitable on load of busbar including nut and bolts complete all as specified and directed
Supply and fixing of CT coil (100/5 Amp rating)
Supply and fixing complete with 1100volt grade PVC insulated unsheathed multistranded 4 sqmm single core copper conductor cable confirming to IS 694 FRLS fixed on control wiring of LT panel/ACB including provision of copper/Aluminium lugs, Copper brass,nut bolts etc all as specified and directed.
Supply and fixing of indicator lamp
Supply and fixing of copper strip of any size for earth conductor, bus bar conductor fixed with on insulator
PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates as in foundation filling land mass concerte for poles and stay/installation paths complete all as specified and directed.
M&L for Spray painting to existing LT panel board/Feeder pillar with two coats of synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces all as specified and directed.
M&L for Earthing complete for machinary/Equipment installed at power house/sub station with galvanised iron earth plate 600 x 600 x 6mm thick burried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5mr below normal ground level connected to galvanised iron strip of size 25 x 4mm by means GI welding after tighten by bolts, nuts, check nuts and washers from earth pit to test point including protection GI pipe of size 40mm bore light grade and providing masonry enclosure and watering pipe of dia 40mm bore light grade including wiremesh steel funnel, including watering arrangement 200 ltrs for each earth pit complete all as shown in electrical No 3 of SSR Part-I connected to main board/ distribution board as specifed and directed. Make of GI Pipe:- TATA/JINDAL/ZENITH (Note : GI strip and G.I protection pipe 7.5 mtr length is included in the quoted rate.)
M&L for GI strip of size 25 x 4 mm for Earth continuity conductor or main earthing lead fixed on wall on insulator or PVC pipe or chases or burried in ground or fixed to poles or any other indicated situation for loop earthing etc as directed .
M&L for painting of existing LT/HT pole upto 9 / 11 meter height with two coat of aluminium paint complete including preparation of old painted surfaces and including making blue / black colour paint strip of 15 cm width including writing the Pole Nos. complete all as specified and directed.
M&L for Angle iron with MS sheet cable route indicator of suitable size angle iron height 50cm and size of ms sheet 20cm x10cmx 3mm thick with written of cable size and fixing below ground level 20 cm including necessary cutting, welding, excavation & earth work . Note:- PCC 1:3:6 will be measured and paid separately
Labour only for removing all vegetation for LT Panel/Feeder Pillar near of 2 Mtr all around and all as specified and directed.
Detection of pin point fault in LT cable (burried in ground/under road/path up to depth of 1.5 m) by cable fault locating machine comprising impulse generator,acoustic fault locator and reflectometer (laptop based) complete all as specified and as directed by Engr-in-Charge. Notes-(1) Cable fault locating machine to be arranged at site with in 12 hrs after intimation (2) Earth work will be measured seperatly.(3) Cost of transpotation in unit rate is deemed to be included. Location:-AF stn BKT.
Industrial Traders
Ajanta Motor Store
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .