Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-Finance | L1 | Accepted-Finance Lowest and reasonable bid | |
| 2 | L2₹20.6 L+₹22,327 (1.10%)Rejected-Finance BOOTH NO 15 SHOPPING COMPLEX URBAN ESTATE PHASE II JALANDHAR CITY PIN 144022 | JALANDHAR | PUNJAB | 144022 | L2 | Rejected-Finance Other than the lowest bid |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (WEST)
KABIR ROAD JALANDHAR CANTT
REPAIR AND MAINTENANCE OF WINTER APPLIANCES AND AC PLANTS UNDER GE (W) JRC
2023_MES_619242_2
GE/JAL(W)-55/2023-24
Open Tender
Civil Works
Item Rate
240 days
JALANDHAR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER (WEST)
₹50,000
Yes
26 Oct 2023
28 Sept 2023
24 Oct 2023
28 Sept 2023
17 Oct 2023
5 Oct 2023
Amount
Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors
M&L for taking down unserviceable geyser of capacity 25 litre storage type, disconnecting necessary connection for repairing including re-fixing the same after repair & reconnection & testing as directed. Note :Thermostat switch, Geyser assembly, Geyser elements, bottom cover etc. if replaced shall be measured and paid separately under respective items.
All as per srl item No 02 here-in-before but geyser of capacity 50 litres complete all as specified and as directed.
Attending complaint for rectification of defects of Geyser and making the Geyser ready for re-use (All spare parts, wire, plug etc.) will be measured and paid for separately under respective items here-in- after all as specified and as directed. NOTES:-(i) Rate quoted deemed to be inclusive of necessary T&P, ladder, Vehicle and desired numbers of well qualified persons with attendant having sufficient experience of work for electrical equipment’s fittings and fixture. (ii) The safety of persons/helpers engaged in execution of this item shall be solely responsibility of the contractor and necessary insurance of these persons should be done and copy of same should be submitted to GE. iii) All measurements shall be recorded indicating Complaint No., date, Location, Date of redressal with regard to Quantity. (iv) Contractor shall employ minimum 02 x Elect with Helper to attend complaints of married & OTM accn from 0900 hrs to 1730 hrs including sunday & holiday. (v) In case of failure on the part of contractor for attending any complaint within 48 hours, a penalty shall be imposed @ Rs 100/- per complaint per day and recovered from his dues.
Repair to steel inner tank of capacity 200 litre to 500 litre capacity after removal from solar heater and further disconnecting off aluminium foil and glass wool and re-assembling the same after repair and re-fixing in position complete all as specified and as directed.
Providing labour for servicing and maintenance of complete solar water heater of various capacities installed at single/double/triple storey bldgs. for plugging leakages, by gas welding, brazing’s, Copper plates, tubes, trays and hot water tank , cleaning of flat plate collector glass & cleaning of Water storage tank and make up tank, including dismantling inlet and out let connections and re-fixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified and as directed. Note : All nessary minor items such as Tee, elbow, Nipple, union, piece of rubber pipe etc. shall be included in item rate quoted by the contractor.
Supply and fix in replacement 15mm bore steel water tubes medium grade galvanized with and including all fittings , guties/saddles etc. including making connections mixing arrangement of hot/cold water and fixed to wall and ceiling or laid in floor with all fittings complete all as specified and as directed.
Supply and fix in replacement 20mm bore steel water tubes medium grade galvanized with and including fittins with guties/saddles etc. including making connections mixing arrangement of hot/cold water and fixed to wall and ceiling or laid in floor with all fittings complete all as specified and as directed.
Supply and fix in replacement 20 mm bore gun metal gate valve both end screwed for pipe fixing with brass spindle and crutch/butterfly handle at top complete all as specified and directed.
Supply and fix in replacement temperature gauge range 0 to 100 as per existing size all as specified and directed by Engr-in-Charge. Make : AMCO/YENKAY
Supply and fix in replacement; toughed glass of collector of size 4mm thick and of size 6' x 4' as per existing arrangement complete all as specified.
Supply and fix in replacement float valve assembly made out of gun metal for 15mm dia pipe complete all as specified.
Supply and fix in replacement float valve assembly made out of gun metal for 20mm dia pipe complete all as specified.
Supply and fix in replacement Geysers assembly of stainless steel along with PVC rubber washer suitable for Geyser of Capacity 25 litres any make as required including taking out the old unserviceable assembly from the geysers complete all as specified and as directed.
Supply and fix in replacement Geysers assembly of stainless steel along with PVC rubber washer suitable for Geyser of Capacity 50 litres any make as required including taking out the old unserviceable assembly from the geysers complete all as specified and as directed.
Supply and fix in replacement heating element 2000 watts of suitable shape/size (cup type/traingle type/Threaded type) with PVC/ rubber washer & clamp including taking out the old unserviceable heating element from the geysers complete all as specified and directed. Make: Thermo king/Theeta/Daspass/ Lazer.
Supply and fix in replacement Geyser assembly along with heating element 2000W & Thermostat as required for Geyser of capacity 25 Ltr and Make : Bajaj / as per Sample complete all as specified and directed.
Supply and fix in replacement; anchor fastner of size 75mm long 8mm dia complete with nut and washers for fixing geyser’s complete all as specified and as directed.
Supply and fix in replacement; thermostat switch suitable for storage type Geysers 25/50 ltr as required shape and size complete including taking out the old unserviceable switch from the geysers complete all as specified and as directed. Make: Bajaj / Recold / Ditz /Sphere top.
Supply and fix in replacement Neon lamp indicator red/green colour of circular/rectangular shape as suitable and as per sample including taking out the old unserviceable lamps from the geysers complete all as specified and as directed.
Supply and fix in replacement non-return valve 15mm dia of brass including taking out the old unserviceable valve from the geysers complete all as specified and as directed.
Supply and fix in replacement PVC connection 45cm (confirming to ISI) long wire woven with nickel plated brass adopter, both side threaded in standard length to suit the geyser assembly for 15mm bore including taking out the old unserviceable connection complete all as specified and as directed.
Supply, hoist and fix in position 500 litres capacity rotational moulded polythene water storage tank (cylindrical, vertical with closed top) ISI marked (Name of firm embossed or engraved on the body of tank) conforming to IS 12701, triple layered complete all as specified.
Material and Labour for Point wiring with 2.5 Sq.mm (nominal area) single core PVC insulated unsheathed FRLS cable, multi-stranded, copper conductor, with universal colour code in existing conduit with existing sunk pressed steel terminal boxes providing 3 mm thick plastic laminated sheet top cover or as existing including PVC insulated copper conductor earth wire of 2.5 Sq.mm size in green colour, cutting chases and making good the disturbed surfaces in cement mortar 1 : 3 complete all as specified & directed by the Engineer-in-Charge. (Switch/ Socket are to be measured and paid separately)
Supply and fix in replacement; sheet metal enclosure with socket plug top, single pole and neutral with a two pin earth plug and socket complete with one single pole MCB-20 Amps 240 Volts including taking out the old unserviceable sheet metal enclosure complete all as specified and as directed.
Supply and fix in replacement; socket outlet flush type 2-in-1, 6 pins, 15 Amps multipurpose including taking down old unserviceable socket from the existing board complete all as specified and directed.
Supply and fix in replacement; top plug, 3 Pin, 15 Amps including taking down old unserviceable top plug complete all as specified. Make : Havells/ SSK/ Anchor
Supply and fix in replacement switch piano flush type 15 Amps, single pole one-way, including taking down old unserviceable switch from the existing board complete all as specified and directed.
Supply and fixing in replacement; 3 core flexible copper conductor cable of size 2.5 Sq.mm ISI marked including taking out the old unserviceable cable complete all as specified and directed.
Supply and fixing in replacement; solar water heating element, cup type 3000 watts of suitable shape/size conforming to ISI with PVC/ rubber washer & clamp including taking out the old unserviceable heating element from the solar water heater complete all as specified and directed. Make : Thermo king/ Theeta/Daspass /Lazer
Supply and fixing socket plug top suitable for metal socket 20 Amps including taking down old one omplete all as specified and as directed. Make : Havells/ Indo Asian/ Anchor
Supply and fixing aluminium service cable PVC insulated flat or circular of size 10 Sqmm 2 Core complete all as specified and directed.
Material and labour for de-scaling of condenser unit 37.5 TR AC central type with copper tubes by removing nuts & bolts, side cover plates, water connection and filling up of de-scaling chemical in condenser and manually cleaning of copper tubes with using Nylon brush of superior quality, iron rod for removing of complete scaling from tubes and water circulation through condenser including replacement of rubber gasket, tightening side cover plates and making necessary connections complete all as specified and as directed. (UG Ops HQ 11 Corps AC Plant )
M&L for servicing of Air handling unit of central AC plant 37.5 TR by removing filters, assembling filters and testing for the following parts. (a) Inspect filters, removing and cleaning by using vaccum cleaner and refix same. (b) Clean cooling coil, fins by using caustic soda and water pressure method and applying Grease for all motors, check and adjust belt tension if required, check condition of blower shaft, impeller and bearings, check tightness of all electrical terminations, clean water line strainers, check proper balancing system , check for noise and vibration. (c) Check healthy operation of controls and safety devices.
Attending breakdown (except periodical maintenace) by skilled Ref Mechanic from OEM/authorised dealer for any type AC plant/cold store of capacity 5 TR to 37.5 TR, diagonising the fault, repair/replacement of unserviceable parts including carrying out minor repairs such as changing of small pieces of wires, tightening of loosen electric connections ,nuts, bolts screws, or switches, disconnecting and refixing of LT cables etc as required to make the system functional in any time by deploying sufficient technician alongwith with helper incl necessay T & P complete all as specified and directed. Note: (a) Replacement of major items shall be measured and paid for separately under respective items. b) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly. (c) Breakdown comlplaints shall be collected from complaint cell or by telephonically from duty staff / JE E/M / Engr-in-Charge. (d) In case of failure on the part of contractor for attending any breakdown within 4 hours a penalty shall be imposed @ Rs.2000/- per complaints per day and recovered from his dues.
Taking down the old discharge/suction/oil pressure sensor and Supply and fix new discharge pressure sensor testing and commissioning 0-5 PSI 37.5 TR compresor
M&L for disconnecting electric motor 7.5 HP and transporting to workshop, dismantling the same and taking out rotor assembly removing burnt winding coil of stator, cleaning the complete stator and rotor with carbon tetra chloride solution, rewinding the stator coil with super enameled copper conductor of proper size/gauge as per existing, inserting the new re-winded coils of stator duly varnishing and insulated with superior quality insulation material, replacement of old connection lead with superior quality PVC copper cable with stranded copper conductor from motor to connection plate, replacement of ball bearing, reassembling the motor, shifting to work site and connecting with the system, testing on full load complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 37 here-in-before but of 0.335 to 0.67 HP (250 to 500 watt), single phase electric condensor fan motor.
Dismantling the mono block pump set with motor any make, upto7.5 HP capacity servicing by cleaning lubricating and by replacing of ball bearing gland bolt, nut and washers, terminal connector, machining of shaft, gasket, gland rope, mounting bolts, reassembling, refixing with bed and testing.
Taking down blower with motor of AHU/Package type AC any capacity, servicing by cleaning , lubricating , machining of shaft, replacement of ball bearing mounting bolts, reassembling and testing complete all as specified and directed.
Taking down condensor fan motor from outdoor condensor unit of any capacity, servicing by cleaning , lubricating , machining of shaft, replacement of ball bearing mounting bolts, reassembling and testing complete all as specified and directed.
Replacement of Fan blade of condensor fan motor of suitable size all as specified and directed.
Supply and fixing in replacement of water pressure gauge 4” dia, range 0 to 100 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
Supply and fixing in replacement of V- belt heavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Dunlop or equivalent
Supply and fixing in replacement of thermostat expansion valve suitable for AC plant 37.5 TR capacity complete all as specified and directed. Make:- Sporlan/ Danfoss/ Renutrol
Supply and fix in replacement Finned strip heater made of GP sheathing having terminals at one end and two holes for horizontal installation of capacity 3 KW in Air Conditioning plant installed at various locations complete all as specified or as directed. Make:- Daspass/Lazer/Usha
Servicing/Maintenance of packaged type AC of capacity 2x17TR TR such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of packaged type AC of capacity 3x11 and 1x5.5 TR such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of packaged type AC of capacity 2x11 such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of packaged type AC of capacity 3x8.75 such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Servicing/Maintenance of VRF packaged type AC of capacity 1x12 and 2x13 TR with 10 Nos cassette indoor units complete such as cleaning of fine filter with water, checking Gas and gas leakage, cleaning of condensing coil/cooling with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor, cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
Replacement of PVC honey comb fills (drift eliminators) suitable size of central type AC plant all as specified and directed.
Supply and fix Single phase preventor having voltage unbalance and phase reversal protection. Make GIC/L&T or other equivalent approved make.
Replacement of electronic timer 240v, 50 Hz, 3-30 sec for star delta starter. Make L & Tor equivalent.
Supply and fixing in replacement of PCB in the existing Packed unit/ Cold room AC Plant including necessary control wiring as required. Make - Softhard Automation Pvt Ltd or in equivalent.
Supply and fixing in replacement Contactor MNX, 32 amp 3 pole, coil voltage as per existing complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing in replacement Contactor MNX, 45 amp 3 pole, coil voltage as per existing complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing in replacement Contactor MNX, 25 amp 3 pole, coil voltage as per existing complete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
Supply and fixing in replacement toggle 5 Amp switch two way brass handle as per sample.
Supply and fixing in replacement of pressure switch LP/HP cut out M15 as per sample. Make- Danfoss/indfoss
Servicing of cooling tower of capacity 100 TR plant by replacement of blocked/broken nozzles, Cooling tower fan and motor, cleaning descaling of complete fins including replacement of broken fin, cleaning water tray, valves, piping etc and testing complete all as per specified and directed.
Supply and fixing in replacement over load Relay 6 to 10 Amp Make -Siemens/BCH/L&T/Schneider.
Supply, fixing, connecting, and testing condenser fan motor of outdoor air-cooled condensers of AC plant/cold store capacity 5.5 TR/7.5TR/11TR as per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
Supply, fixing, connecting, and testing evaporator fan motor of cold store capacity 5.5TR/8.5 TR as per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
Supply, fixing, connecting, and testing molecular drier cum strainer on line type of size 3/8" x 3/8" make Danfoss in AC plant capacity 5.5/7.5/11/12/13/17 TR as per existing type and size including taking out of unserviceable drier complete all as per specified and directed.
Supply and lay electrical insulating rubber mat class ‘B’ conforming to IS 5424 (ISI marked) of 15 mm thick of size 1mx2m, suitable for HT/LT switch gears complete all as specified and directed. Make : Jyoti/Vardhman or equivalent.
Supply and fixing informatory board of size 1200x900 mm frame made out of MS square tube of size 25mmx25mm, 1.6 mm thick and front side covered with coloured flex sheet duly printed with required information all as specified and directed. Dept will provide the details of writing letter and colour of sheet and letters to board.
M & L Check for any refrigerant leaks through flare joints, valve glandsor any of the loc in refrigerant system which requires leak detector device, soap solution,halide torch or electronic leak detector and arresting leakages including necessary welding, brazing works binding with teflon tape as required at site and topping up the gas for required suction & discharge pressure for 37.5 TR central type AC Plant. Note : Refrigerant shall be measured and paid seperately.
Material and labour for charging Nitrogen Gas in 37.5 TR capacity central AC plant maintaining pressure 350 Psi for checking of Gas leakage and removing water vapour choked in line, flushing out the complete system including gas leakage and detection with halide torch/ soap foam solution in system including gas welding flushing and making good the pipe line to make the system leak proof complete all as specified and as directed.
M&L for vaccumising the plant by using vaccum pump up to (-) 30 PSIG pressure and hold the same under vaccum pressure upto 24 hours including necessary welding and brazing if required complete all as specified and directed for 37.5 TR AC plant .
Supply and charging refrigerant Gas R-407 AC plant of various capacities including maintaining proper pressure after filling of Gas complete all as specified or as directed by Engineer-in-Charge.
Supply, install, testing and commisioning of Chiller control unit with display board complete set suitable for 37.5 TR central type AC plant as per existing pattern and make it functional all as directed. Make : Softhard or equivalent as approved by GE.
Supply and fixing of sign board as mentioned words (As per sample) Location and GE (West), front display made out of flex board mounted on cuboid shaped frame of required size made out of MS angle 50x50x3mm and other five sides covered with aluminium composite panel sheet 1.16 mm thick (as per sample) of size 0.15Mx 3.0Mx0.45M . The display board totally enclosed with stainless steel 304 graded pipe 25 mm bore frame and mounted on and including provision of LED Tube light fitting as required for effective illumination and connecting with nearest light point by providing PVC insulated 2 core 1.5 sqmm copper cable of required length all as directed.
S& F (in replacement) Vaccum control damper of existing size suitable for AC plant capacity 5.5/7.5/11/12/13/17 TR including taking out of unserviceable damper complete all as per specified and directed.
Supply, install, testing and commisioning of Package type AC control unit with display board complete set suitable for 5.5/7.5/11/12/13/17 TR multiunit AC plant as per existing pattern and make it functional all as directed.
B.P CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .