The tenderer must have minimum average annual contractualturnoverof[V/N or 'V' whichever is less; where V = Advertised value ofthe tenderincrores of Rupees N= Number of years prescribed forcompletion ofworkfor which bids have been invited. The averageannualcontractualturnover shall be calculated as an average of"totalcontractualpayments" in the previous three financial years, as pertheauditedbalance sheet. However, in case balance sheet of thepreviousyear isyet to be prepared/ audited, the audited balance sheet ofthefourthprevious year shall be considered for calculatingaverageannualcontractual turnover. The tenderers shall submitrequisiteinformation asper Annexure-VIB, along with copies of AuditedBalanceSheets dulycertified by the Chartered Accountant/ CertificatefromCharteredAccountant duly supported by Audited Balance Sheet.
The tenderer must have to submit valid electrical contractor licences.per Indian Electricity Rules for the respective category of works issuedby the Government Electrical License Board on or before the closing dateoftender. A copy of the electrical contractor licence should besubmitted along with the tender offer; otherwise, the tender will besummarily rejected.
Experience in similar nature of work:- a) The tenderermusthavesuccessfully completed any of the following during last07(seven)years,ending last day of month previous to the one in whichtender isinvited:Three similar nature of works each costing not less thantheamountequal to 30% of the advertised value of the tender, or Twosimilarnatureof works each costing not less than the amount equal to40% oftheadvertised value of the tender, or One similar nature ofworkeachcosting not less than the amount equal to 60% of theadvertisedvalue ofthe tender. (b) (i) In case of tenders for compositeworks (e.g.worksinvolving more than one distinct component, such asCivilEngineeringworks, S&T works, Electrical works, OHE works etc. Andin thecase ofmajor bridges - substructure, superstructure etc.), thetenderermusthave successfully completed any of the following duringlast 07(seven)years, ending the last day of the month previous to the oneinwhichtender is invited: Three similar nature of works each costingnotlessthan the an amount equal to 30% of the advertised valueofeachcomponent of the tender, or Two similar nature of workseachcosting notless than the amount equal to 40% of the advertisedvalue ofeachcomponent of tender, or One similar nature of work eachcosting notlessthan the amount equal to 60 % of the advertised valueofeachcomponent of the tender. Note for b(i): Separate completedworksofminimum required values for each component shall alsobeconsideredfor fulfillment of technical eligibility criteria. (b) (ii) Insuchcases, whatconstitutes a component in a composite work shall beclearlypredefinedwith estimated tender cost of it, as part of thetenderdocuments withoutany ambiguity. (b) (iii) To evaluate thetechnicaleligibility of thetenderer, only components of work as stipulatedintender documents forevaluation of technical eligibility shallbeconsidered. The scope of workcovered in other remainingcomponentsshall be either executed by thetenderer himself if he hasworkexperience as mentioned in clause 7 (a)(ii) of Part-II of GCC orthroughsubcontractor fulfilling the requirementsas per clause 7 of Part- IIof GCCor jointly i.e., partly himself andremaining through subcontractor,withprior approval of Chief Engineerin writing. However, if required intenderdocuments by way of SpecialConditions, a formal agreementdulynotarised, legally enforceable in thecourt of law, shall be executedby themain contractor with thesubcontractor for the component(s) ofworkproposed to be executed bythe subcontractor(s), and shall besubmittedalong with the offer forconsidering subletting of that scope ofworktowards fulfillment oftechnical eligibility. In case after the award ofthecontract or during theexecution of work it becomes necessary forthecontractor to changesubcontractor, the same shall be donewithsubcontractor(s) fulfilling therequirements as per clause 7 of Part-IIofGCC, with prior approval of theChief Engineer in writing.
The Similar nature of works for this instant tender shall be"Supply,installation, testing and commissioning of any LT/HT electricalwork"
51 conditions · 5 needing a document upload
Whether the cost of earnest money deposited
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
A) Provision of overhead tank,deep tube well,iron removal plant in the section PHI- BRLF under the jurisdiction of Sr.DEN/I/LMG (Electrical Portion). B) At BPB: Construction of staff quarters (Type-II: 15 units) in replacement of dilapidated old MG quarters of Hill Colony under SSE/W/BPB (electrical portion). C) At BPB: Construction of staff quarters (Type-II: 15 nos) in replacement of dilapidated old MG quarters of Buddha Colony under SSE/W/BPB (electrical portion) .
EL-LM-26-27-28~NFR
EL-LM-26-27-28
Open
Works - General
120 Days
Hojai, Assam
₹0
₹1.4 L
16 Sept 2026
16 Sept 2026
25 Sept 2026
151 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 44,67,507.42 | ||
| — | 3.00 | — | — | ||
| Supply, Installation, Testing and Commissioning (SITC) of ISI-marked 3-phase submersible pump set suitable for bore-well application, complete in all respects, having 7.5 HP/5.5 kW capacity, suitable for operation on 3-phase, 415 V ±10%, 50 Hz AC supply, with maximum current rating of 14.5 A, discharge capacity of 3.33 LPS at rated head of 100 m, 12 stages and rated speed of 2880 RPM. The pump shall be 5-Star rated energy-efficient, suitable for installation in bore wells of minimum 150 mm internal diameter, with 50 mm outlet, and suitable for pumping clear, cold water. The pump shall conform to IS 8034 (latest applicable edition) and be ISI marked, while the submersible motor shall conform to IS 9283 (latest applicable edition), of wet-type construction, suitable for continuous duty (S1), with Category-B insulation. The pump set shall be installed strictly as per manufacturer's recommendations and directions of the Engineer-in-Charge, including necessary trial run, testing and performance verification to ensure satisfactory operation and achievement of rated discharge and head. All materials, accessories, fittings, cables, terminations, supports, fasteners and any other components essential for safe, reliable and efficient operation, though not specifically mentioned, shall be deemed included in the scope of work. The quoted rate shall be inclusive of all materials, labour, transportation, tools & plants, testing, installation, commissioning and incidental charges required for complete and satisfactory execution, with no extra payment admissible on this account. | — | — | — | 1,64,071.41 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Testing and Commissioning (SITC) of fully automatic Star-Delta starter suitable for 7.5 HP pump motor, complete in all respects, suitable for operation on 3-phase, 415 V ±10%, 50 Hz AC supply, designed for reliable starting, protection and control of the submersible pump motor. The starter shall incorporate necessary control and protection features including thermal overload relay, short-circuit protection through MCCB/HRC fuse, single- phasing/phase-failure protection, under-voltage/over-voltage protection, dry-run protection wherever applicable, and adjustable timer for Star-Delta changeover. The starter shall be provided with ammeter and voltmeter with selector switch for phase selection and a 3-position Auto-Manual-Off selector switch for operational flexibility. The panel enclosure shall be of stainless-steel (SS) construction, weatherproof, dust and vermin proof, suitable for outdoor installation with minimum IP- 54 protection, and shall be mounted on a suitable MS frame/wall-mounting arrangement as required at site. The work shall include fixing of the starter panel, power and control cable termination, earthing, functional testing and trial operation of the pump motor through the starter, and complete commissioning as directed by the Engineer-in-Charge. | — | — | — | 40,247.85 | |
| — | 900.00 | — | — | ||
| Supply of 2 inch dia CPVC pipe suitable for use as delivery/column pipe for submersible pump application, conforming to relevant IS standards, complete with necessary sockets/couplers, capable of withstanding the required working pressure. The pipe shall be corrosion-resistant, having smooth internal finish, suitable for potable/clear water application, and shall be supplied in standard lengths as approved by the Engineer-in-Charge. | — | — | — | 1,59,930 | |
| — | 1000.00 | — | — | ||
| Supply, erection and commissioning of 12 mm dia steel wire rope with PVC insulation coating, suitable for suspension and safety protection of the submersible pump against accidental falling inside the bore well, complete in all respects. The wire rope shall have adequate tensile strength, be corrosion-resistant and suitable for submersible pump lowering applications, and shall be provided with all necessary clamps, thimbles, fasteners and fixing arrangements for secure attachment to the pump and top support. The scope shall include cutting to required length, lowering, fixing, securing and testing of the complete arrangement as per site requirements and directions of the Engineer-in-Charge. | — | — | — | 3,09,560 | |
| — | 1000.00 | — | — | ||
| Supply, laying, testing and commissioning of 3 Core x 10 Sq.mm flat copper cable, PVC insulated and PVC sheathed, suitable for submersible pump/power supply application, of 1100 V (1.1 kV) grade, conforming to IS 694 (latest applicable revision), complete in all respects. The scope shall include laying of cable in bore well, trench or on surface as required, proper dressing and securing, termination with suitable cable glands, lugs and ferrules, insulation resistance testing, continuity testing and commissioning, all as per manufacturer's recommendations and directions of the Engineer-in-Charge at site. | — | — | — | 5,55,860 | |
| — | 6.00 | — | — | ||
| Supply, installation, wiring,testing and commissioningof light point complete withsurface wiring carried outthrough good quality hardPVC casing-capping ofsuitable size including allaccessories such as bends,tees, couplers etc., using1.5 sq.mm single core PVCinsulated flexible copperconductor cable of approvedmake. The point shallinclude provision and fixingof flush type 5/6 Ampcontrolling switch mountedon suitable hard plasticmoulded board. The casing-capping shall be fixed onwall / ceiling with MS screws(6x40 mm) at intervals notexceeding 300 mm. Thework shall include propertermination, dressing ofwiring, connectors / ceilingrose (if required), trial operation and testingcomplete in all respects tothe satisfaction of theEngineer-in-Charge. | — | — | — | 1,016.16 | |
| — | 3.00 | — | — | ||
| Supply and wiring of ceilingfan point through goodquality hard PVC casing withassociated accessories forsurface type wiring by 1.5mm sq single core PVCinsulated flexible coppercable with earth continuityby 16SWG bare copper wireand flush type 5/6 ampcontrolling switch to beprovided on hard plasticmoulded board including300W box type steppedelectronic fanregulator.Ceiling fanconnection shall be donethrough ceiling rose. Casingshall be fixed on the wall /ceiling by MS (6x40 mm)screw at an interval notmore than 300mm.Workincludes proper termination,dressing of wires, continuityand insulation testing, andmaking the point fullyfunctional complete asdirected by the Engineer-in-Charge and conforming torelevant IS specifications | — | — | — | 885.51 | |
| — | 6.00 | — | — | ||
| Supply, fitting, fixing,connection & commissioning of 18/20 watt LED indoor fitting complete set with LED tube and other accessories. The fitting shall be connected by 1.5sq mm flexible copper wire through pvc pipes/casing as required at site. | — | — | — | 1,868.22 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of ceiling fan 1200 mm with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value 6.0 CM/Min/Watt(minomum), air delivery 210 CM/Min (Minimum), 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required | — | — | — | 8,085 | |
| — | 3.00 | — | — | ||
| Supply and erection of earthing made of B class GI pipe of 4000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip(50x6)mm should be welded with the earth pipe. The pipe is provided with tapered casing at the lowerend in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil.Where soil restivity is high,earth restivity enhancing material may be used,Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. This will supersedes the earlier drawing no. PCEE/ELG/DRG/2024/1 dated 30.09.24 & CEE/STD/1 As per Drg.No.: PCEE/ELG/DRG/2024/1/Rev-1 dated 28.07.2025 & as per Technical circular no.EL/PS/2025/1 (Pipe Earthing arrangements) | — | — | — | 4,337.61 | |
| — | 3.00 | — | — | ||
| Supply, installation, testingand commissioning ofexhaust fan point completewith surface wiring carriedout through good qualityhard PVC casing-capping ofsuitable size including allaccessories such as bends,tees, couplers etc., using1.5 sq.mm FRLSHR single core PVC insulated flexible copperconductor cable of approvedmake along with earthcontinuity provided by 16SWG bare copper wire. Thepoint shall include provisionand fixing of flush type 5/6Amp controlling switchmounted on hard plasticmoulded board. Connectionto exhaust fan shall bemade through ceiling rosecomplete. The casing-capping shall be fixed onwall/ceiling using MS screws(6x40 mm) at intervals notexceeding 300 mm. Thework shall be complete in allrespects to the satisfactionof Engineer-in-Charge. | — | — | — | 880.02 | |
| — | 3.00 | — | — | ||
| Supply, installation, fitting,fixing, connection, testing and commissioning of 300mm sweep heavy dutyexhaust fan of approvedmake, suitable for operationon 230 V, 50 Hz AC supply,complete with mountingarrangement, necessaryclamps / brackets, nuts &bolts, rawl plugs and allfixing materials. The workshall include makingelectrical connection fromexisting exhaust fan point,proper alignment, smoothoperation testing andcommissioning. Allconsumables required forproper fixing and installationshall be supplied by thecontractor as per siterequirement and as directedby the Engineer-in-Charge. | — | — | — | 4,188.12 | |
| — | 6.00 | — | — | ||
| Supply and wiring of 5/6amp, 5 pin plug point through good quality hard PVC casing with associated accessories for surface type wiring by 1.5 mm sq FRLSHR single core PVC insulated flexiblecopper cable with earthcontinuity by 16 SWG bare copper wire and flush type5/6 amp controlling switch to be provided on hard plastic moulded board. Casing shall be fixed on the wall / ceiling by MS (6x40 mm) screw at an interval not more than 300mm. Work includes proper termination, dressing of wires, continuity and insulation testing, and making the point fully functional complete as directed by the Engineer-in-Charge and conforming to relevant IS specifications. | — | — | — | 1,081.5 | |
| — | 6.00 | — | — | ||
| Supply and wiring of 15/16amp, 6 pin plug pointthrough good quality hardPVC casing with associated accessories for surface typewiring by 4 mm sq singlecore PVC insulatedflexiblecopper cable with earthcontinuity by16 SWG barecopper wire and flushtype15/16 amp controllingswitch to be provided onhard plastic moulded board.Casing shallbe fixed on thewall / ceiling by MS(6x40mm) screw at aninterval not morethan300mm .Work includesproper termination, dressingof wires, continuity andinsulation testing, andmaking the point fullyfunctional complete asdirected by the Engineer-in-Charge and conforming torelevant IS specifications | — | — | — | 1,915.2 | |
| — | 200.00 | — | — | ||
| Laying, fitting, fixing and commissioning of LT/HT XLPE insulated, armoured power cables with aluminium conductors of different sizes, suitable for the required voltage grade, including proper dressing, clamping and securing of cables partly along poles/structures and partly in ground cable trenches as per site requirement. The work shall include excavation of trenches, sand bedding, protective covering with bricks/tiles, refilling and compaction, ensuring proper route marking and safety precautions as per relevant IS standards (IS:1255/IS:7098 or latest). It also includes loading, unloading, safe transportation and carrying of cables to site by contractor's own arrangement as directed by the Engineer-in-Charge. Termination and jointing shall be carried out using approved kits with proper crimping, sealing and ferruling to ensure reliable performance. Necessary testing such as insulation resistance, continuity and phase identification shall be done before commissioning, and the entire work shall be executed as per relevant IS specifications and instructions of the Engineer-in-Charge at site. | — | — | — | 8,742 | |
| — | 200.00 | — | — | ||
| — | 140.00 | — | — | ||
| — | Breakup | for details. | — | ||
| Under SSE/P/CPK | — | — | — | 31,78,191.02 | |
| — | — | — | 11,89,573.91 | ||
| — | 154.00 | — | — | ||
| Supply of materials and wiring of light point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper conductor through PVC conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with glowing indicator type) to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed concrete portion will be painted by contractor as per site colour of the surface. Make - Cable- Finolex, Havells, KEI, Polycab, Casing & Capping/Conduit pipe- Diamond, Presto Plast, Richa Ceiling/Rose & Switch - Crabtree, Anchor, Legrand. The whole work shall be executed as per direction of site engineer. | — | — | — | 70,122.36 | |
| — | 60.00 | — | — | ||
| Supply, fitting, fixing,connection & commissioning of 18/20 watt, 230V, 50Hz LED indoor fitting complete set with LED tube and other accessories. The fitting shall be connected by 1.5sq mm flexible copper wire through pvc pipes/casing as required at site. | — | — | — | 18,682.2 | |
| — | 55.00 | — | — | ||
| Supply and fitting of 9 WLED bulb, 6500 K (coolwhite), complete with lampholder, connector, and allnecessary accessories forinstallation. The work shallinclude proper fixing,connection to the existingpower supply, testing forillumination, andcommissioning to thesatisfaction of the Engineer-in-Charge.(45 nos. for Qtrs. and 10 nos. for Stair case light) | — | — | — | 6,971.25 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-28.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .