Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 241 2ND MAIN STREET LAKSHMIPURAM PALANI DINDIGUL DISTRICT 624 601 | DINDIGUL | TAMIL NADU | 624601 | ₹1.7 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC ok |
| 2 | L2₹1.4 Cr+₹16,744.80 (0.12%)Rejected-AOC DISTT SIKAR | SIKAR | RAJASTHAN | ₹1.4 Cr+₹16,744.80 (0.12%) | L2 | Rejected-AOC Reject |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
16 Aug 2023, 3:00 pmClosed
Executive Officer, Kariapatti Town Panchayat
Town Panchayat Office, Kariapatti Town Panchayat
Construction of Shops in Existing Bus Stand Survey No.50/1 in Kariapatti Town Panchayat
2023_DTP_348716_2
123/2023
Open Tender
Civil Works
Works
360 days
Kariapatti
Contractor Class - I
4 documents required · 4 mandatory
₹0
₹1.7 L
Kariapatti
22 Sept 2023
5 Aug 2023
17 Aug 2023
5 Aug 2023
16 Aug 2023
5 Aug 2023
10 Aug 2023
Amount
Earth work excavation for foundation and depositing on bank for refilling within an initial lead of 10.00 m and an initial lift of 2.00 in hard stiff clay. Stiff black cotton soil, hard red earth, sales, murrams, gravel, stoney earth, earth mixed with small sized boulders and hard gravelly soil and except hard rock requiring blasting including shoring, strutting, bailing water wherever necessary and all other incidental charges etc., complete as directed by departmental officers as per S.S.20B
Plain Cement Concrete 1:4:8 mix, (one part of cement, four part of M. sand and eight part of aggregate) mix using 40mm ISS HBG metal from approved Quarry including cost and conveyance of all materials and all labour charges for mixing, laying, compacting and curing the concrete and other incidental charges etc., complete. as per standard specification 28 V,VI S25
Supplying and filling with well gravel Dust from approved quarry including cost and conveyance of all materials and all labour charges for filling, watering & consolidation etc., complete as per standard specification
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Basement
Ground Floor
First Floor
Supply and fabrication of steel using TMT rods for all Reinforced cement concrete works including cost and conveyance of all materials and all labour charges for cutting, bending and placing the rod in position and tying up the rods with binding wire and other incidental charges etc., complete. as per standard specification SS 86 & 86A V,VI, VII (S6) 7,3
Supply and erection of steel centering, shuttering for soffits and sides including necessary support strutting for all RCC works using MS sheets of suitable size of BG 10 stiffened with MS angle of size 25x25x3mm for boarding laid over Silver Oak joists of size 10cmx6.5cm space at 10cm c/cand supported by Casurino Prop 10cm-13cm spaced at 75cm c/c etc., complete and as directed by Departmental Officers.
Column Surface
Plain Surface
Shuttering
Brick Work in Cement Mortor 1:5 Mix (one cement, five M.sand) using new best II Class Bricks of size 9 ” x 4 3/8 “x 2 3/4 ” from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications
Basement
Ground Floor
First Floor
Plastering in C.M. 1:3mix (one part of cement and three part of M.Sand) 10 mm tk including mixing and finishing to a well smoothened surface, watering cost and conveyance all materials and all labour and other incidental charges and other incidental charges etc., complete. as per standard specification TNBPSS 56,57
Plastering in C.M. 1:5 mix (one part of cement and five part of M.Sand) 12mm tk including mixing and finishing to a well smoothened surface, watering cost and conveyance all materials and all labour and other incidental charges and other incidental charges etc., complete. as per standard specification TNBPSS 56,57
Supply and Fixing of Rolling Shutter of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification .
Supplying and fixing over the floors best quality of Kota Stone of approved colour laying with cement mortor 1:3 mix pointing the joints with colour pigments including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification .
Weathering course with concrete of broken Brick jelly in pure slacked lime over roof slab the proportion of brick jelly to lime being 32 to 12.5 well beated with wooden beaters for giving required slope & thickness including cost and conveyance of all materials and labour charges and other incidental charges etc., complete as per standard specification
Finishing with top of roof with one course of machine pressed tiles of size 20cm x 20cm x 20cm of approved quality laid in cement mortar 1:3 (One cement and three sand) 12mm thick mixed with water proofing compound conforming to ISS by 2% weight of cement used and the joint pointed neatly to full depth of tiles with same water proofing compound mixed with cement motar ,red oxide, including cost and conveyance of all materials and labour charges and other incidental charges etc., complete as per standard specification
Supplying and fixing of Mild Steel Grill work of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification
Wiring with 2x1.5sqmm (22/0.3) PVC insulated unsheathed SC Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A F.T. switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (For electronic regulator)(SD.No.24)
Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3 mm thick Hylem sheet cover for 5 A 3 pin non inter lockingWall socket with 5A Flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. (SD No.38)
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15A 3 pin non inter locking wall socket with 15A flush type switch with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed power plug point (SD 40)
Supply and fixing of 4'40 W LED fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification (SD 88)
Supply and fixing of 32 Amps DP Switch of 500V with metal clad with fuse and neutral (Side Handle) on suitable TW Board with PWD Earthingincluding cost and conveyance of all materials to site and all labour charges etc complete asper std. specifications. (SD 143)
Supply and run of 4 x 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification (SD 68)
Supply and fixing of 1200 mm (48') AC Ceiling Fan complete with stepped electronic 300 W Regulator with 1 m down rod on existing Clamp of approved quality including cost and conveyance of all materials and labour charges and other incidental charges etc., complete as per standard specification (SD 107)
Painting two coats with Emulsion paint of approved colour and quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification
Painting two coats over new iron works with Enamel paint of approved colour and quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification
Supply and fixing of Stainless Steel Handrails for Staircase using 50 mm dia 304 L Grade Stainless Steel pipe of 1.60 mm thick at requied locations to a height of 900 mm from finished floor level welded to 38 mm dia Stainless Steel pipe post of 1.00 mm thick as vertical at 900 mm centre with 2 Nos of 25 mm dia intermediate horizontal stainless steel pipe of 1.60 mm thick between. The vertical pipe has to be welded to the 100x 100x 6mm MS base plate encased in the base concrete. The rate inclusive of the charges for cutting, bending, welding,grinding, polishing, conveyance, electrical charges etc., complete. (Item No.M-0651)
Supply and Fixing 110 mm dia PVC Pipe of approved quality for rain water including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification
M/s. RK AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .