| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹30.7 L+₹1.4 L (4.80%)Rejected-Finance PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹32.7 L+₹3.5 L (11.9%)Rejected-Finance 12 NO 12 IRATTAI PILLAYAR KOVIL STREET NEAR REAL VALUE FLAT VELACHERY 733 CHENNAI TAMIL NADU 600042 | CHENNAI | TAMIL NADU | 600042 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | L4₹33.5 L+₹4.3 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Being L4 bidder | |
| 5 | L5₹33.6 L+₹4.3 L (14.7%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L5 | Rejected-Finance Being L5 bidder |
Tender Value
₹32.8 L
EMD Value
₹65,680
Closing Date
26 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Avinash Mishra IDSE EE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
PROVISION OF AC SOCKET OUTLETS 15 AMPS 2000 WATT
2024_MES_638573_1
8444/BBSR/05/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
Paradip
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) (CG) Bhubaneswar
₹65,680
Yes
26 Mar 2024
22 Jan 2024
2 Mar 2024
22 Jan 2024
26 Feb 2024
8 Feb 2024
Amount
Supply and fixing Factory made sheet metal enclosure for DBs Double door (Fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified and directed.
Supply and fix MCB DP, 240 volts, 40 amps breaking capacity 10KA, ‘C’ Series complete all as specified and directed.
Supply and fix MCB single pole 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘C’ series complete all as specified and directed.
Material and Labour for sub main wiring complete with 2 single core multi stranded copper conductor 4 sqmm (Nominal area) PVC insulated unsheathed cable drawn in and including medium grade PVC conduit/Casing Caping ISI Marked not less than 25 mm dia in surface/recessed, including making good distrubed surface, of wall, including single core multi stranded copper conductor 4 sqmm size as earth wire drawn in same conduit/Casing Caping complete all as specified and directed . Note : 2 Nos of Single core cable alongwith earthwire and PVC conduit shall be measured as one length.
Supply and fix MCB single pole and neutral enclosure with a two pin and earth plug and socket modular Type complete with and including one MCB single pole 20 amps, 240 volts C series complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including taking down old unserviceable cable of any size, brick protection etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out in soft soil for laying of cables, foundation of poles, and stay assembly complete all as specified and directed.
Supply and filling Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness complete all as specified and directed. Note : Punned thickness will be measured and paid.
S&L well burnt sub class ‘B’ bricks (using old size brick) laid in trenches above sand cushioning for cable protection complete all as specified and directed.
Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 Mtr depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed.
Supply and Fix MCB 415 Volt 4 Pole, 15KA 100 Amps in existing panel as outgoing complete all as specified and directed.
Taking Down Old Unserviceable MCB 63 Amps complete all as specified and directed.
Supply and laying of GI tubing Medium grade 50 mm dia with all fittings laid in trenches/road crossing/along the pole for protection of cable complete all as specified and directed.
Cutting Bituminous road in,making good with facing where required and pointing exc.30 cm. but not exc.1.0 mtr. girth to ends or edges and cutting chases for concealed water tubing and making good with old shape and size complete all as specified and directed.
SMART ENERGY SOLUTIONS
Elite Enterprises
Rekha Enterprises
M/S SOMANATH ENTERPRISES
Shree Mahavir Associates
PABITRA MOHAN PARIDA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .