Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹41.0 L+₹82,988.50 (2.06%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | L2 | Rejected-Finance Other than Lowest tenderer | |
| 3 | L3₹44.8 L+₹4.6 L (11.3%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance Other than Lowest tenderer | |
| 4 | L4₹48.2 L+₹8.0 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest tenderer | |
| 5 | L5₹48.7 L+₹8.5 L (21.1%)Rejected-Finance 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-Finance Other than Lowest tenderer |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
31 Oct 2023, 6:00 pmClosed
Vipin Chandra Rai
GE Utility Bathinda Mil Stn
REPAIR /REPLACEMENT OF STREET LIGHT, SECURITY LIGHT IN ZONE 1 UNDER GE UTILITY BATHINDA.
2023_MES_619584_2
8739/2023-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
Class D cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility Bathinda
₹1 L
Yes
24 Nov 2023
16 Oct 2023
2 Nov 2023
16 Oct 2023
31 Oct 2023
24 Oct 2023
Amount
Comprehensive maintenance of street light consisting of repair,maintenance and attending of day to day complaint of street / security light of any type, any wattage & any make , complaints received through telephone or in person as directed by site engineer or Engineer in charge at any place in bathinda cantt. under GE(U) includes:- (a) Lugs,insulation tape, cable connector (PVC) and disposable items required on site. (b) Ladders, Tools and safety equipment as required to be provided by contractor. (c) contractor manpower shall attend daily to receive complaints at complaint cell at 9.00 AM failing which Rs 100.00 per day fine will be charged. (d) Daily Complain will be fwd by site engineer to concerned designated supervisor/ contractor/ electrician. If not resolved with in 24hrs extra Rs100.00 per complaints fine will be charge. (e) New light fittings/ driver/ MCB/MCCB/ contactor/bracket/service wire will be measured seprately under supply only items
Supply Only GI pipe bracket, made out of 35/40 mm dia light grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with 02 Nos. MS clamp of MS flat iron 40 x 6 mm with bolts, nuts and washer complete all as directed by Engineer-in-Charge.
Supply Only 4 sqmm 2 core, LT 1100 volts grade , PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt for service connections complete all as directed.
Supply Only 6 sqmm 2 core, LT 1100 volts grade , PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt for service connections etc all as directed.
Supply Only 10 sqmm 2 core,LT 1100 volts grade , PVC insulated and PVC sheathed, solid aluminium conductor cable, flat type, 1100 volt for service connections etc all as directed.
Supply only constant current electric potted driver suitable for LED type fitting up to 50 Watt 350MA/700MA/1050MA/1150MA Driver complete all as directed.
Supply only constant current electric potted driver suitable for LED type fitting from 50 Watt to 75 Watt 350MA/700MA/1050MA/1150MA Driver complete all as directed.
Supply only constant current electric potted driver suitable for LED type fitting from 75 Watt to 120 Watt 350MA/700MA/1050MA/1150MADriver
Supply only energy efficient LED street light fitting of 70 Watt capacity with toughened clear glass , LED chip efficacy > 130 lumen / watt, system efficacy > 120 lumen / watt, luminarie shall be mandatory brand embossed on luminaries, potted antivibration driver. The driver shall be able to withstand for indoor at 440V for 8 hours . The driver should have fascility and cut off voltage. Input over voltage protection will be > 300 Volt AC and for cut off the luminaires should withstand for 48 hours at 100 Volt AC. The LED efficacy shall be more than 85% at a junction temperature of 85 degree centigrade. All screws of the luminaires should be SS304. Luminaires pressure dicast aluminium housing with mendatory secondary optics, CCT: 5700K ANSIBIN, CRI > 70, LED source : 1-5 Watt high power type , driver of luminaire shall be preferably in separate compartment another optical compartment .The LED driver shall be constant current type fully potted. Driver shall be provided for all luminaires. It should be moiture resistant and fire reterdant. At least industrial grade or higher grade component should be used for manufacturing of driver. The driver shall be able to withstand surge (EFT+ESD interference) of minimum 4 KV. Luminaire shall have surge protection device of minimum 10 KV inside the driver compertment. The driver shall have under voltage, over voltage and short circuit protection and auto recovery mode. Total harmonic distortion shall be < 10% with power factor minimum 0.95. It should give consistent performance in the input voltage range of 120 V - 270 V at 50 Hz. Luminaires shall be mandatory brand embossed of luminaries and including all electric connection and accessories complete all as directed.
All as per serial item No. 09 above but for LED light fitting 90 Watt.
Supply only energy efficient LED flood light fitting of 150 Watt capacity with toughened clear glass , LED chip efficacy > 130 lumen / watt, system efficacy > 120 lumen / watt, luminarie shall be mandatory brand embossed on luminaries, potted antivibration driver. The driver shall be able to withstand for indoor at 440V for 8 hours . The driver should have fascility and cut off voltage. Input over voltage protection will be > 300 Volt AC and for cut off the luminaires should withstand for 48 hours at 100 Volt AC. The LED efficacy shall be more than 85% at a junction temperature of 85 degree centigrade. All screws of the luminaires should be SS304. Luminaires pressure dicast aluminium housing with mendatory secondary optics, CCT: 5700K ANSIBIN, CRI > 70, LED source : 1-5 Watt high power type , driver of luminaire shall be preferably in separate compartment another optical compartment .The LED driver shall be constant current type fully potted. Driver shall be provided for all luminaires. It should be moiture resistant and fire reterdant. At least industrial grade or higher grade component should be used for manufacturing of driver. The driver shall be able to withstand surge (EFT+ESD interference) of minimum 4 KV. Luminaire shall have surge protection device of minimum 10 KV inside the driver compertment. The driver shall have under voltage, over voltage and short circuit protection and auto recovery mode. Total harmonic distortion shall be < 10% with power factor minimum 0.95. It should give consistent performance in the input voltage range of 120 V - 270 V at 50 Hz. Luminaires shall be mandatory brand embossed of luminaries and including all electric connection and accessories complete all as directed.
Supply and erecting in repair of 7.00 meter long hot dip galvanized iron street light octagonal pole with foundation type base plate and foundation bolts (Dimensions for pole as top diameter 70 mm, bottom diameter 130 mm, Section Length- 7000 mm, Thickness-3 mm, Foundation type base plate (220 mm X 220 mm X 12 mm), Foundation bolts 04 Nos (M20 X 600 mm) including single bracket arm of 1.5 meter long, 6 Amp MCB SP and RCC foundation as shown as on drawing as attached complete all as specified and directed. Note:- (i) The cost of necessary earthwork , RCC concrete work with reinforcement , required form work, foundation bolts and bracket deemed to be included in the quoted rates. . (ii) The T&P vehicles will be arranged by the contractor for transporting the pole and the cost deemed to be included in the quoted rates.
Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 16 Sqmm 4 Core complete all as directed by Engineer-in-Charge.
All as per serial item No. 14 above but for size of cable 25 Sqmm 4 core. Note for serial item No. 14 & 15: (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, laying of cables or pipes (where provided) for protection of cable and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed .
Returning, filling in, approved soft/loose soil, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all specified and as directed by Engineer-in-Charge.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all specified and directed by Engineer-in-Charge.
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150 mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified and directed.
Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size any core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junctionbox/LT panel/O/H line etc all as directed. Note:- (I) the cost of required earth work ie excavation,returning filling,relaying of sand/bricks and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid seperatly.
S&F in repair PVC cable Junction box for street light including 6 to 32 Amp MCB SP with aluminium bus bar TPN for controlling the Street Lights with pole mounting type size 250x200x105mm with 02 Nos. MS clamp of MS flat iron 40 x 6 mm with bolts, nuts and washer fixed on poles/walls complete all as directed by Engineer-in-Charge.
S&F in repair MCB TPN, 415 volt of capacity 63 Amp, short circuit, breaking capacity not less than 16 KA , including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .
S&F in repair MCB 'C' Curve, SP ,240Volt, 6 Amp to 20 Amp 10 KA complete all as specified and directed by Engr-in-Charge.
S&F in repair of MCB 'C' Curve, SPN ,240Volt, 20Amp 10KA complete all as specified and directed by Engr-in-Charge.
S&F in repair three Pole Contactor 25/50Amp 240V AC complete all as specified and directed by engr-in-charge.
Cutting/trimming of tree branches upto 1.50 mtr distance on both sides of LT over head lines including collection and removal from road complete all as directed by Engineer-in-Charhge.
M&L for making the hole under road and hard standing suitable for laying and inserting pipe upto 80 mm dia any length by mechanical drill system or Auger system and making the surface good as existing surface complete all as specified and directed by Engineer-in-Charge. Note: GI pipe shall be measured and paid separately under respective item.
Supply and laying in repair GI tubing, light grade, 50 mm bore with all fittings for cable and earth continuity strip protection laid in trenches/fixed to poles/along wall/under road/across the drain complete all as specified and as directed by Engineer-in-Charge.
Material & labour for Attending of complaint of existing 16 meter long High Mast light of any type, any wattage & any make , complaints received through telephone or in person and identification of defects , bringing down the system upto a normal heigt be manual/motorized & fixing at the same position after rectify the defect including flexible wire of required size, cleaning of light Fittings for clear reflection of light, as required to make the light fitting functional (vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement). Note : - (i) Contractor shall be provide / depute sufficient number of electricians and helpers ( as directed by Engineer-in-charge) to attend the complaints and rectified/replacement of parts, and the complaint shall be resolve within 24hours of receipt of complaints.If Contractor fails to attend & resolve the complaint within 24hours an recovery of Rs.100.00 per complaint shall be recovered from contractor dues. (ii) contractor manpower shall attend daily to receive complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes
M&L for repair of mechanism of High mast and rewinding of three phase tower motor 440volt AC if burnt and incl. dismantling from high mast transport to workshop for rewinding with existing size of super enameled copper wire, replacing of gear, bearing bush etc for running of rope at satisfoctory level and reinstallation complete all as specified and directed.
S&F in repair Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed . Note : The rate of one primer coat, one under coat and one finishing coat of paint are included in this item.The payment shall be made as per actual weight of steel used only.
Supply , fixing and stretching in repair ACSR of any size as per site requirement on existing HT/LT poles including binding on existing insulator with aluminium binding wire 2 mm dia complete all as specified and directed by Engineer-in-charge. Note :- 1. For measurement and payment purpose only the weight of ACSR shall be considered .The weight of aluminium binding wire 2.00 mm shall not be considered. 2. The rate of aluminium binding wire 2.00 mm is included in this item and nothing shall be paid extra on this account.
Un binding from old insulators and taking down old unservicable insulators and re–stretching the existing ACSR of any size on LT poles including binding the ACSR with new insulators and including aluminium binding wire 2 mm dia complete all as specified and as directed by Engineer-in-charge. Note :- The rate of aluminium binding wire 2mm dia is included in this item and nothing shall be paid extra on this account.
Supply and connecting in repair three core cord flexible wire copper conductor multistranded PVC insulated and overall PVC sheathed of size 1.5 sqmm 1100V connection to street light from junction box as directed by Engr-in charge .
Vardhman Airport Solutions Pvt Ltd
M/s Rohit Construction Co.
M/s NIRMAN BUILDERS
MAHESH KUMAR SINGLA CONTRACTOR
DIAMOND SALES COROPORATION
M/s Kataria Construction Company
B K CONTRACTORS
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .