Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC D NO 03 52 NEHRU NAGAR COLLECTORATE PO DHARMAPURI 636 705 | DHARMAPURI | TAMIL NADU | 636705 | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.2 L+₹75,073.90 (2.01%)Rejected-Finance KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | L2 | Rejected-Finance L2 | |
| 3 | L3₹38.5 L+₹1.1 L (2.96%)Rejected-Finance 1 8 373 FLAT NO 704 KRISHE GARDEN BEGUMPET BEGUMPET HYDERABAD TELANGANA 500016 | MEDCHAL MALKAJGIRI | TELANGANA | 500016 | L3 | Rejected-Finance L3 | |
| 4 | L4₹38.6 L+₹1.2 L (3.32%)Rejected-Finance D NO 1 71 48 NANDAGOKULA MSEZ COLONY ROAD NO 20 KODIKERE KULAI DAKSHINA KANNADA KARNATAKA 575019 | DAKSHINA KANNADA | KARNATAKA | 575019 | L4 | Rejected-Finance L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Technically Disualified |
Tender Value
₹39.2 L
EMD Value
₹78,390
Closing Date
3 Nov 2022, 4:00 pmClosed
Director of Lighthouses and Lightships, Goa
Deepbhavan, Near GMC Stadium, Bambolim-403202
Re-wiring of Lighthouse Tower, Power house, Staff Quarters, Inspection Quarter, Supply and installation of street lights poles in staff quarters compound and LH Rock and ESE Lighting Arrestor for Kaup Lighthouse under Goa.
2022_DGLL_715098_2
EM-Goa-01001(16)/1/2022-Em
Open Tender
Electrical Works
Works
90 days
Kaup Lighthouse
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
The Director of Lighthouses and Lightships, Goa
₹78,390
Yes
Directorate of Lighthouses and Lightships, Goa
24 May 2023
14 Oct 2022
4 Nov 2022
14 Oct 2022
3 Nov 2022
14 Oct 2022
14 Oct 2022 - 18 Oct 2022
31 Oct 2022
Amount
Re-wiring of Lighthouse Tower at Kaup Lighthouse - ANNEXURE – I Moduler Switche Boxes Sockets & Switches
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. Mm (for fan and light points in service room and tower bottom)
3 x 2.5 sq. mm(From DB to Switch Board)
4 x 1.5 sq. mm(for staircase wiring From LH tower bottom to service room)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm) (PVC) (for Wall mounted fan)
3 Module (100mm * 75mm) (PVC)
12 Module (200mm * 150mm) (PVC)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation, testing and commissioning of ceiling fan/wall mounting fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing PVC batten / angle holder including connections etc. as required. (1 for lantern room)
Switch Gear and DB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 6A(4 Nos for service room)(2 Nos for LH bottom)
Single pole 16A (LH bottom)
Double pole (6A)(LH Service room)
Supplying and fixing following rating, double pole, 240 V, isolator in the commissioning etc. as required. existing MCB DB complete with connections, testing and and commissioning etc. as required. (at service room and LH bottom)
40 A (1 No for Service room, 1 No for LH bottom stair case)
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (at service room and LH bottom)
40 A (1 No for Service room, 1 No for LH bottom stair case)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.
8 way, Double door (2 Nos LH tower Service room)(1 No for LH bottom)
Supply of Indoor Industrial Tube Light Battens, with LED Tube (inclusive), LED Batten with Essential 4' 22W LED tube. (refer Sl No.1.035 for installation)
Supply of 10W LED Bulk Head Luminaries IP65/66/67 LED Light source (inclusive) with integrated LED source.
Supply of LED LAMP 12W(Base B22 12-Watt LED Bulb)dimmable Master LED Glass Bulb (refer Sl No.1.035 for installation)
Supply of Wall Mounting Fan, 400 millimetre Bracket mounted fan for Wall mounting (Mist Air Duos) Hi-Speed,
Supply of Cable ducting (base+cover) Transcab - 60 X 80 mm - PVC cable management duct for laying cable from tower bottom to Top. ( Each duct 2 mtre length.)
Supply of 1 inch (25X16mm) U-PVC mini trucking system each 2 mtr length (for staircase light wiring)
Supply and laying of 3core X 2.5 Sqmm Copper armoured PVC insulated/PVC sheathed XLPE power cable as required.(from Power house to Lighthouse service room top 65 meter to main light )+(25 for stair case Light fro PH to Lh Bottom )+ (25 for NAIS from PH to LH bottom)
Supply of Bare Copper wire, 8 SWG
Laying of 8 SWG copper wire in cable duct from power house to service room DB & LH tower bottom DB.
Laying & fixing of cable duct (for vertical run) and re-routing of Old NAIS, other cables and New cable in cable duct from Tower bottom to lighthouse tower top (service room) (35meter height tower)
Miscellaneous items for the purchase of S.S screws and washer(for fixing cable duct), drill bits, fishers(heavy wall plugs) 250mm cable ties, SS 'U' Clamps, flexible pipes, etc.,
Re-wiring of Power House, Staff Quarters and Inspection Quarter at Kaup Lighthouse -ANNEXURE – II
MODULAR SWITCH BOXES, SWITCHES AND SOCKETS
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mm * 75mm)
3 Module (100mm * 75mm)
6 Module (125mm * 125mm)
8 Module (125mm * 125mm)
12 Module (200mmX150mm)
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Bell push
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required. (fancy type)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
CONDUIT AND CABLE
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm(for Lamp Holder)
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
SWITCH GEAR
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted\ including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way, Double door
12 way, Double door
16 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 10A
Single pole 16A
25 A Triple pole and neutral (for LH power house)
Supplying and fixing following rating, double pole, 240 V, isolator in the commissioning etc. as required. existing MCB DB complete with connections, testing and Commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.(for LH power house Genset body & neutral earthing) in beach area.
Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required. (For Genset Body & Neutral Earthing) from earth pit Power house)(LH power house situated in Rock above beach ground level to PH 100 meterX2)
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.(NA-Qtrs - 3 Nos No, IQ-1 No, LHA qtrs - 2 No, Pump House - 1 No,staff quarters compound power house - 1 No)
Supply of Indoor Industrial Tube Light Battens, with LED Tube (inclusive), LED Batten with Essential 4' 22W LED tube. (refer Sl No. 2.031 for installation)
Supply of Bulk Head Luminaries IP65/66/67 IK09/10 LED Light source (inclusive) with integrated LED source.
Supply of LED LAMP 12W(Base B22 12-Watt LED Bulb)dimmable Master LED Glass Bulb
Supply of Wall Mounting Luminaries, 7W Full Glass LED lamp B22/E27 (Non Dimmable) (refer Sl No.2.031 for installation)
Supply of Ceiling Fan, Electro-phonetic lacquered/ Electroplated surface for anti-rusting, High speed fan with wider tip blade for effective air circulation with Sweep 1200mm and Hight performance even at low voltage. (refer Sl No.2.030 for installation)
Supply of Outdoor 25Watt LED COB street light fitting (Die cast powder coated enclosure with structured LED arrays and IP65/66 protection and)
Providing and fixing of street light bend pipe 1"(inch) GI class "C" pipe including clamp/SS screws etc.,
Supply of Bare Copper wire, 8 SWG earth wire (for all quarters)
Labour charge for laying 8 SWG wire from ground level to Distribution box through pvc pipe with clamp.
Supply and Fixing of PVC Energy meter box with necessary holes.(suitable for existing energy meter with kitkat 32 A fuse and neutral link)
Supply and Fixing kitkat 32 A fuse and neutral link.
Supply and laying of Electricity Service wire 2 run X 6 sqmm copper cable with necessary insulated support wire from Electric pole to Energy meter(LHA twin qtrs - (60+60) 120, NA Qtrs 3 Nos - (80+50+80) mtrs, including all accessories, like screws, clamps, bolt and nut etc.,)
Providing and fixing of 25 mm GI pipe Class C ("U"bend pipe) for to laying service wire from pole to energy meter (including all accessories like, GI nipple, GI bend, copper clamp, ss bolt and but, etc.,)(for Na qtrs 3 Nos, LHA qtrs - 2 Nos)
Supply and laying of 3core X 4 sqmm Copper armoured PVC insulated/PVC sheathed XLPE power cable as required. (Power house to pump House)
Supply and laying of 2 core X 10 sqmm Copper armoured PVC insulated/PVC sheathed XLPE power cable as required. (Power house to IQ)
Supply and Installation of 100A Triple Pole Neutral Link with HBC Cum Rewireable Porcelein Fuse Unit(for LH power house)
Supplying of 4Core X 16Sqmm copper armoured PVC insulated/PVC Sheathed XLPE power cable as required(from Staff quarters compound to LH tower)(Staff qtrs compound situated other location LH tower situated other location)
Laying and fixing of 4Core X 16Sqmm copper armoured cable through over head in GI pole from staff quarters compound to LH tower (Staff qtrs compound situated other location LH tower situated other location) (Drawing enclosed)
Supply and fixing of Porcelain Pin Insulator, 400V-33kv with necessary GI clamp, Angular, SS bolt and nut etc., in GI Pole.
Applying wall white putty and painting in wherever plastering work done in all quarters.
Labour charge for Dismantling of old wiring, fans, cables, switch board and electrical fittings etc., at NA Qtrs 3 No, LHA qtrs 2 Nos, IQ and power house and dismantling of Old panel Board etc., handed over to Station incharge.
Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, 25mm PVC bends, tees, 1,2,3,4 way junction boxes, Cutting plates, 12 mm Fan hooks, Fan rod for extension, wire strippers, steel spring, pvc junctions boxes, SS Clamp etc., Wall white putty and paints.(for Na qtrs 3 Nos, IQ - 1 No,LHA qtrs - 2 Nos, PH - 1No)
Making earth pit charges(additional) refer Sl No.2.054 (for earthing) Lighthouse located beach area difficult to digging earth pit(take out water and labour charges) beach side (for plate earthing)
Supply and fixing 11/2" PVC HDPE flexible(Hard) pipe Thickness aprox 3mm hard pipe I Rock/stone (for laying 25X3mm copper strip from earth pit to power house)
Making earth pit charges(additional) of Sl No.12.056 for Lighthouse located at hill & rocky area difficult to digging earth pit(take out water and labour charges)
Black stone cutting charges for concealed wiring and making hole 600 mm wall for cable entry As buildings are constructed by black stone.
Supply of 16 Sqmm, 4 core Pvc Ins Copper Flexible Cable (for internal loop wiring in power house)
Supply and Installation of Street light poles with LED fitting for staff quarters compound at Kaup Lighthouse-ANNEXURE – III
Electrical Fittings /Cables/
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double pole (6A)
Providing, laying and fixing 80mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required (for CC paver block crossing)
Supply of Outdoor 25Watt LED COB(chip on board) street light fitting (Die cast powder coated enclosure with structured LED arrays and IP65/66 protection and)
Supply of Outdoor IP65 Wall Mounting Gate Light Luminaries, 20W LED with Big doom
Supply and laying of 3core X 2.5sqmm Copper armoured PVC insulated/PVC sheathed XLPE power cable as required.
Supply of 2.5 Sqmm Cable gland
Supply and Installation 3" Dia Class "C" GI pipe 4 meter Length (as per drawing) along with applying 1 coat primer and 2 coat aluminium paint.
Supply and Installation of 1" threaded 45 degree bend pipe 1 meter length along with applying 1 coat primer and 2 coat aluminium paint.
Supply and Installation of 3" to 1" GI reducer alongwith applying 1 coat primer and 2 coat aluminium paint.
Supply and fixing of SMC Pole mounted Junction Box (200X140X95mm)with side hinged door, IP55 with necessary clamps/ Strip, SS screws/Nut and blot, etc.,
Supplying and laying of 3 Core 1.5 Sqmm PVC Copper cable (from street light fitting to jn box)
Supply and fixing 11/2" PVC HDPE flexible(Hard) pipe Thickness aprox 3mm hard pipe (To fixing foundation for laying cable from under ground to junction box)
Supply of 1 Phase street light timer
Supply of PVC enclosure for fixing street light timer
Making cable trench for laying cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (street light cable, IQ Cable and pump house cable)
Electrician (Labour) Charges for wiring of streetlights, and fitting luminaries, timer, etc.,
Foundation and base work for Streetlights
Base of Streetlights: Earthwork Excavation in beach area(staff Qtrs compound) and take out water during excavation (0.6 x 0.6 x 0.5m) for the foundation of steettlight, 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Concrete Work (0.6 x 0.6 x 0.5m) for the foundation with Post pipe placed in concrete inclusive of materials, Brick Work (0.45 x 0.45 x 0.45m) for post base and placing of pipes for cable entry, Plastering Work (4 x 0.45 x 0.45) +(0.45 x 0.45) for post base and Painting Work applying 1 coat White primer Paint and 2 coat Synthetic enamel Red Paint.(4 x 0.45 x 0.45)+(0.45x 0.45)
Labour charge for dismantaling of old street lights
Miscellaneous items for the purchase of SS bolt and nut etc.,
Supply and Installation of Street light poles in Hill/Rock at Kaup Lighthouse -ANNEXURE – IV
Electrical Fittings /Cables/
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double pole (6A)
Supply of Outdoor 50 Watt LED COB(chip on board) street light fitting (Die cast powder coated enclosure with structured LED arrays and IP65/66 protection and)(11 pole X2 = 22)(For tourism purpose)
Supply of 3core X 4sqmm Copper armoured PVC insulated/PVC sheathed XLPE power cable as required (from power house to street light point in LH rock street light pole)
Laying of 3core X 4sqmm Copper armoured cable through HDPE pipe from power house to street light point in LH rock street light pole)
Supply of 2.5 Sqmm Cable gland
Supply of 3" Dia Class "C" GI pipe 6 meter Length Octagonal pole with inbuilt JB arrangement (Top 50mm bottom 100mm thickness 3mm base plate 220X220X12mm, 220mm PCD along with applying 1 coat primer and 2 coat aluminium paint.(For LH pathway)
Supply of 3" Dia Class "C" GI pipe 4 meter Length Octagonal pole with inbuilt JB arrangement (Top 50mm bottom 100mm thickness 3mm base plate 220X220X12mm, 220mm PCD along with applying 1 coat primer and 2 coat aluminium paint.(For LH Rock)
Supply and Installation of 2 arm Street light bracket alongwith applying 1 coat primer and 2 coat aluminium paint.
Supply of 1 feet "L" type GI bolt and nut(For concrete base bolt and nut)(4 bolt and nut for 1 set)
Supply of wooden template
Supply and fixing of SMC Pole mounted Junction Box (200X140X95mm)with side hinged door, IP55 with necessary clamps/ Strip, SS screws/Nut and blot, etc.,
Supplying and laying of 3 Core 2.5 Sqmm PVC Copper cable (from street light fitting to jn box)
Supply of 2.5 sqmm copper flat submersible cable in air from LH rock street light pole to pay way of LH street light pole
Laying of 2.5 sqmm copper flexible cable in air from LH rock street light pole to pay way of LH street light pole
Installation of 4/6 meter Street light pole, 2 Arm bracket, junction box, streetlight fittings, mcb, etc.,(including necessary clamps/ Strip, SS screws/Nut and blot, etc.,)
Supply 1FtX1ftX1ft RCC ring
Supply and fixing 11/2" PVC HDPE flexible(Hard) pipe Thickness aprox 3mm hard pipe (from power house to LH rock street light pole) Clamping and concrete on HDPE pipe.
Supply of 1 Phase street light timer
Supply of PVC enclosure for fixing street light timer
Foundation and base work for Streetlights
Base of Streetlights: Earthwork Excavation in beach area (Path way of lighthouse from staff qtrs to LH) (0.6 x 0.6 x1.5m) and take out water during excavation for the foundation of streetlight, laying 1.5 feetX1.5feet RCC ring from earth pit ground level to 2 meter height & 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Concrete Work in RCC ring (0.60 x 0.60 x 2m) for the foundation with Post pipe placed in concrete inclusive of materials, Plastering Work (4 x 0.45 x 0.45) +(0.45 x 0.45) for post base and Painting Work applying 1 coat White primer Paint and 2 coat Synthetic enamel Red Paint.(4 x 0.45 x 0.45)+(0.45x 0.45)
Stone dressing for pit making size of 0.45(L)X0.45(W)X 0.6(D) meter (in Rock) and RCC block making with reinforcing of GI anchor type structure welded with pole base plate(12mm GI Plate to hold the street light poles on stone in 100km/hr wind speed (including all accessories, like heavy drilling machinary, etc)
Miscellaneous items for the purchase of SS Screws, bolt and but washer etc.,
Supply and Installation of ESE Lightning arrester at Kaup Lighthouse-ANNEXURE – V
Lightning arrester
Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required. (For Lightning arrester)(from Earth bit to Lightning arrester)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.(For Lightning arrester) IS 2309 1969: Code of practice for the protection of building and allied structures against lightning.(Two earthing)
Supply of Early Streamer Emission (ESE) lightning conductor. Equipped with Stainless central pick up rod. Full electrical continuity between the tip and the earth point. Fully autonomous (no battery, no external power supply required) Collect energy through streamer emission controlled with detects the lightning and trigger a streamer (3,5KV and 20A). The ESE shall cover the area of 60 mtrs. Radius. Manufactured as per CPRI Requirements & as per Indian standard.
Supply of 6 mtr. single length elevation pole (Lightning arrester mast) made of GI “C” Class 40mm dia. with a M20 thread at the top to fix the ESE unit. Necessary provisions shall be provided for stay wire termination, fixing of insulated copper flat laying from the top (ESE unit) of the mast to bottom of the mast. The bottom of the mast shall be welded with 300 x 300 x 10mm GI plate and supported gazette plate with 4 nos. of 22mm hole suitable for making foundation bolt for fixing the mast. The stay wires shall be made of 6mm SS in the grade of 304 with suitable SS wire rope clamp which withstand salty atmosphere and wind speed of 150km/hr.
Providing and fixing of additional 6 feet Triangle GI support to the mast pipe with hand rail using 40mm GI ‘C’ class pipe by using copper clamp with SS bolt and nut.
Supply of Lighning flash counter
Supply of 40mm insulator pipe for fixing ESE lightning arrester pipe with basement of mast pipe.
Supply of Test link box(GI)(Test link point should be copper strip with brace bolt and nut)
Installation of ESE Lightning arrester, insulator pipe, lightning mast Pipe, flash counter, Test link, etc.,
Supply and fixing 11/2" PVC HDPE flexible(Hard) pipe Thickness aprox 3mm hard pipe in Rock/stone (for laying 25X3mm copper strip from LH bottom to earth pit)
Making earth pit charges(additional) refer Sl No.5.012 (for earthing) Lighthouse located beach area difficult to digging earth pit(take out water and labour charges) (for plate earthing)
(refer Sl No 5.011) (Additional + risk charge) Laying of 25X3mm copper strip (For vertical run) at the out side of LH tower on surface of wall from Lighthouse tower top (lightning arrester) to LH bottom earth pit by clamping the tape at the distance of 2 feet using insulator, fisheres(wall plug), ss screws tools.(including all accessories like, Nylon rope, safety belt etc.,)(35 meter height)
Miscellaneous items for the purchase of S.S screws, SS washer, bolt & nut, Ceramic Strip Insulator- 80 Nos, insulation tape, Insulation sleeve, Fishers(wall plug) etc.,
Power Care Electrical
Abacus Infrastructures Pvt Ltd
Raaj power solutions and facilities
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .