Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹12.7 L+₹3.2 L (33.7%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹13.3 L+₹3.8 L (40.0%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹14.6 L+₹5.1 L (53.3%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹14.8 L+₹5.3 L (55.4%)Rejected-Finance 1040 12 3 BABA KARAM CHAND STREET NEAR MAHANTA DI KOTHI DORAHA 141421 DISTT LUDHIANA PB | DORAHA | LUDHIANA | PUNJAB | 141421 | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
1 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
COMPREHENSIVE REPAIR AND MAINT OF ELECTRICAL INTERNAL SERVICES OF MES INSTALLATION AT ZONE D AT LGJ MIL STN
2022_MES_549253_1
8933-34/22-23
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹36,000
Yes
5 Nov 2022
1 Sept 2022
4 Oct 2022
1 Sept 2022
1 Oct 2022
16 Sept 2022
Amount
Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/cable etc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth all as specified and directed by Engr-in-Charge
Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed by Engr-in-Charge
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge
M&L sand cushioning, with dry and clean fine locally available sand for underground cable 8 cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge. Note : Punned thickness shall be considered for payment purpose.
Supply and laying best quality locally availble Sub class 'B' bricks(old size) for cable protection cover, laid flat and lay in trenches over the cable complete all as specified and directed.
Supply and laying in replacement LT XLPE cable 1100 Volt grade 25 Sqmm 4 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct complete including taking out and deposit at MES store for further disposal all as specified and directred.
Supply and laying in replacement LT XLPE cable 1100 Volt grade 35 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct complete including taking out and deposit at MES store for further disposal all as specified and directred.
Supply and laying in replacement LT XLPE cable 1100 Volt grade 50 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct complete including taking out and deposit at MES store for further disposal all as specified and directred.
Supply and laying in replacement LT XLPE cable 1100 Volt grade 70 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct complete including taking out and deposit at MES store for further disposal all as specified and directred.
S&F in replacement of cross arms, bracings, supports, clamps, back plates, angle iron/ flat in any size fabricated from structural steel section, including nuts, bolts, washers, welding (incl wleding at site), bending cold or hot, drilling hole for botls, in any shape or size including two coats of aluminium paint over a coat of red oxide primer after preparation of steel surfaces all as specified and directed
M&L for Painting of pole, flat iron clamps, Junction boxes of security lights on poles fabricated from mild steel including nuts, bolts, washers, with two coats of aluminium paint over a coat of red oxide primer after cleaning/ removal of dust etc. for preparation of steel surfaces all as specified and directed.
M&L PCC (1:2:4) type B1 using 20mm graded stone aggregates as in coping of poles etc including weathering slightly roundded or chamfered angle and throating necessary form work finishing all exposed faces of concrete etc complete all as specified and directed. Note :( Volume of poles/struts embedded in concrete shall be deducted. )
M&L PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation of electric poles/struts etc including necessary form work and fair finish to exposed surface without using extra cement complete all as specified and directed. Note :( Volume of poles/struts embedded in concrete shall be deducted. )
Material and labour for pre stressed concrete poles LT 9 Mtr long 102mmx 172mm at top and 102 mmx279 mm at bottom class-10 complying with reqirement of 15 1678-1978 including painting of pole with two coat of synthetic enamel paint with black and white strips of 30 cm each upto 1.5 Mtr height from the top of PCC coping and numberintg of poles all as specified and directed
S & F in repair factory made sheet metal distribution boards, SPN, 4 way; double door, protection class IP-30 suitable for mounting MCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed
Supply and fix sheet metal enclosure, DBs for MCBs, 2 way, 240 volt double door protection class IP-30 all as specified and Directed
S & F in repair MCB SPN 6 to 32 Amp, 240 Volts, rupturing capacity 9 KA confirm to IS- 8828-1996, IEC - 60898 complete all as specified and directed
S & F in repair MCB SP 6 to 32 Amp, 240 Volts, rupturing capacity 9 KA confirm to IS- 8828- 1996, IEC - 60898 complete all as specified & directed
M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled, white, with letters, figures and conventional skull and bones in signal Red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20x15 cm size complete all as specified and directed
M & L for galvanised iron strip 32x6 mm burried in ground for connection of earthing pit to LT panel and testing point complete all as specified and directed by Engineer-in-Charge.
S&F guard craddle, made to shape hexagonal/rectangular or any other shape as required and directed, fabricated out of galvanised steel wire 4mm dia incl binding wire all as specified and directed.
M&L for 40mm bore GI pipe light grade with all fittings and fixtures fixed to pole and laid to floor/ground for mechanical protection of cable of the following sizes:-
,---ditto--- as per srl item No 22 above but 50 mm bore pipe.
,---ditto--- as per srl item No 22 above but 80 mm bore pipe.
Dismantling of existing LT pole any size/type from foundation in necessary earth work including dismentling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed.
Dismantling of existing stay assembly any type/size from its stay rod, putting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed.
Dismantling / taking out old ACSR/copper conductor/GI earth wire anyu size from existing over head lines incl disconnection all as specified and directed.
Dismantling /taking out insulator of any size/type from existing electric LT lines all as specified and directed.
Dismantling /taking out service connection/cable any type/size removing connection from existing over head lines complete all as specified and directed.
Dismantling /taking out old mild steel channel/agnle iron as in cross arms fixed to electric poles complete all as specified and directed.
Supply & Fix in replacement MCCB TP with thermal Megnatic release, breaking capacity 16 KA, rating 100 Amp, 3 pole, 415 volts all as specified and directed.
Supply & Fix in replacement MCCB TP with thermal Megnatic release, breaking capacity 35 KA, rating 200 Amp, 3 pole,415 volts all as specified and directed.
Supply & Fix in replacement MCCB TP with thermal Megnaic release, breaking capacity 35 KA, rating 400 Amp, 3 pole,415 volts all as specified and directed.
Supply & Fix in replacement of MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 25 KA all as specified and directed
Supply & Fix in replacement of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA all as specified and directed
Supply & Fix in replacement of MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 25 KA all as specified and directed
Supply & Fix in replacement of MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 25 KA all as specified and directed
Supply & Fix F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA all as specified and directed
M & L for danger notice plate of 1.6mm thick mild steel sheet ,vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with M.S clamps , bolts and nuts of approved size for HT 25x15 cm size complete all as specified and as directed including taking down old u/s one.
M&L heat shrinkable straight through XLPE/ PVC cable joint LT of size 25 sqmm to 70sqmm 3.5 core after dismantling unserviceable one.
,---ditto--- as per srl item No 40 above but of 95 sqmm to 120 sqmm 3.5 core.
,---ditto--- as per srl item No 40 above but of 150sqmm to 185/225sqmm 3.5 core
Cleaning and maintenance of existing earth pit by removing the muck from the earth pit, cleaning the funnel wiremess, watering, the earth pit with salt and coal and making the good surface of earth pit and cover by plastering with CM 1:4 and connecting the earth from earth pit to testing point with GI strip 32x6mm. Note GI strip shall be measured and paid separatley under respective item of BOQ.
Supply and fixing cable route indicator made out of precast RCC 1:2:4 type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia MS bars of semicercular shape 15 cm dia 10 mm thick duly engraved MES LT cable having RCC piller of size 10 cm x 10 cm x 60 cm embedded 45 cm below ground level and 15 cm above ground level and painted with two coats of synthetic enamel paint aboe ground level including necessary excavation and earth work complete all as specified and directed by Engr-in-Charge
Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6.0 mm thick burried directly in ground earth pit not less than 2.25 Mtr deep below normal ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron earth Lead wire 4 mm dia as earthing lead by means of bolts, nuts, checknuts and washers of galvanised iron all as shown in electrical plate No 3 of SSR Part-I, connected to GODO / Lightening arrester / LT panel all as specified including GI pipe 20 mm bore medium grade for watering, PCC chamber using PCC 1:3:6 type C-2 CI frame and cover, funnel and wiremesh, all excavation and earth work etc complete all as specified and directed by Engr-in-Charge Note : (i) PCC chamber shall beconstructed 1 m away from the earth pit and pipe for watering shall be provided in a slanting manner. (ii) The portion of GI strip burried in ground shall be protected by providing GI pipe 40 mm dia medium grade, the cost of which is deemed to be included in the quoted rates
M&L for repairing LT panel board by necessary welding to door hinges, and fixing the sliding bolt for proper locking arrangement and making all electical connection including replacement of rubber beading spray painting to the electrical panel by scraping old paint over a coat of red oxide complete all as specified and as directed.
Supply & fixing switch piano type flush button single pole one way 5/6 Amps, 230 volts all as specified & directed by Engineer-in- charge.
M&L in repair switch piano type flush button single pole one way 5/6 Amps, 230 volts inc taking down old one all as specified & directed by Engineer-in- charge.
Supply & fixing switch piano type flush button double pole two way 15 Amps, 230 volts inc taking down old one all as specified & directed by Engineer-in- charge.
Supply & fixing socket outlet 2 in 1, 3 pin 5 Amp,flush type inc taking down old one all as specified & directed by Engineer-in- charge.
M& L in repair socket outlet 2 in 1, 3 pin 5 Amp,flush type inc taking down old one all as specified & directed by Engineer-in- charge.
Supply & fixing bell push flush button 5/6 Amps, 230 volts all as specified & directed by Engineer-in- charge.
Supply & fixing switch piano type flush button single pole one way 15/16 Amps 230 volts all as specified & directed by Engineer-in- charge.
M&L in repair switch piano type flush button single pole one way 15/16 Amps 230 volts all as specified & directed by Engineer-in- charge.
Supply & fixing socket outlet two in one, 6 pin 5 Amp and 15 Amp flush type all as specified & directed by Engineer-in- charge.
M & L in reapir socket outlet two in one, 6 pin 5 Amp and 15 Amp flush type all as specified & directed by Engineer-in- charge.
S & F Lamp holder incl LED lamp 9 watt, insulated body with back plate etc all as specified and as directed by Engr-in-Charge.
Supply & fixing ceiling rose surface bakelite 65 mm x 50 mm size, 3 terminals complete all as specified and directed by Engineer-in-Charge.
S & F fan regulator electronic socket type 80/100 watt all as specified and as directed by Engr-in-charge.
M & L in repair fan regulator electronic socket type 80/100 watt including taking down old one complete all as specified and as directed by Engr-in-charge.
Supply & fixing electric bell ding dong 230 volts AC supply all as specified and directed by Engineer-in-Charge.
Supply and fix switch socket outlet 3 pin 5 amp' flush type all as specified and directed .
Supply and fix in repair Switch socket combination 2 in 1, 5 A flush type inc taking down old onecomplete all as specified and as directed.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1 inc taking down old one complete all as specified and as directed.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Singla Electricals
Soma Enterprises
NATIONAL ENTERPRISES
M/s R.N Construction Co.
DASHMESH ENTERPRISES
Lalgarhia Enterprises
M/s JUGAL KISHORE MISHRA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .