Tender Value
₹8.6 L
EMD Value
₹17,160
Closing Date
15 Jul 2020, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2020_PWDJK_99226_1
e-NIT No.EDJ/27 of 2020-21 Dated 29-06-2020
Open Tender
Electrical Works
Item Rate
42 days
SAMAGRA Shiksha at Arnas
please refer to NIT
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹17,160
Yes
4 Aug 2020
30 Jun 2020
16 Jul 2020
1 Jul 2020
15 Jul 2020
1 Jul 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed conduit as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 Sq.mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Bell push
Supplying and fixing following sizes/ Modules, GI box along with modular base and cover platefor modular switches in recess etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
12 Module
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Single Pole and Neutral
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing of L.T switch gear power control panel floor/Wall mounted Indoor type totally enclosed, compartmentalized, cubical made of 2mm thick sheet duly powder coated free from dents, dust uneven surfaces and vermin proof (as per technical specifications suitable for 415 volts 3 phase 4 wire 50 HZ AC supply complete with hinged doors having looking arrangment with provision of space for MCCB. COS, Bus Bar etc as required. The job includes interconnections testing, commissioning and providing earthing connection to panel. (Design of panel has to take from XEN/AEE. The size of panel can be change as per required design.).
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
MCCB FP 160 Amp. 36 KA ICU=ICS=100%
Aluminium Bus bar 500 amp 4 strip.
Change Over Switch 100 A FP MCCB Type
Supplying installation testing and commissioning of XLPE insulated and PVC sheathed / power cable of 1.1 KV grade of following size in ground.cable tray as per site conditions as required.
95 sq. mm x 3.5 core Armoured.
Supplying and fixing of Electrical items.
MCB 63 Amp
Round Sheet
Fan Sheet
Angel/Batten Holder.
LED Bulb 15 watt
LED Bulb 9 watt
Supplying and fixing of 20/22 watt LED 4 feet tube light fitting/fixture CRCA housing with 2000 Lumens and min lumens efficiency 100 Lumens/watt P.F 70.95 THD < 16% & voltage input range 140-270 V with Shot circuit & overloading protection circuit off
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply.
Ceiling fan 1200 mm sweep along-with rod up-to 1'-6" long as required.
Exhaust fan 300 mm sweep metalic
Supplying and fixing of (90 + 5) watt LED Street Light complete with M.S/GI pipe bracket duly embeded along the parapet /wall including complete connections as required.
Supply, installation, testing & commissioning of inverter (900 ± 50) VA alongwith tubular battery 150AH (36 months Warranty) and plastic trolley for inverter & trolley (complete set)
M/S UNIQUE ENGINEERS AND SUPPLIERS
joydeep wali
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .