Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹19.9 L+₹2.8 L (16.8%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹22.7 L+₹5.7 L (33.8%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹24.2 L+₹7.2 L (42.4%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹26.7 L+₹9.7 L (57.0%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
8 Nov 2022, 6:00 pmClosed
GE MH and RH KIRKEE
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Kirkee Pune 411003
REPAIR RENEWAL MAINTENANCE OF INTERNAL ELECTRIC WIRING AND CERTAIN CONNECTED WORKS AT PHASE II AND OTM AREA OF MH KIRKEE UNDER GE MH AND RH KIRKEE
2022_MES_557141_1
8358/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE MH and RH KIRKEE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH and RH KIRKEE
₹60,000
9 Jan 2023
11 Oct 2022
10 Nov 2022
11 Oct 2022
8 Nov 2022
27 Oct 2022
11 Oct 2022 - 1 Nov 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc and making good disturbed surfaces of walls, floors, all as specified.
M & L for point wiring complete with and including 1.5 sqmm (nominal area) single core multi stranded copper conductor PVC insulated but unsheated FRLS cable 1100 Volts drawn in to and including ISI marked of suitable size of PVC conduit with accessories such as tee, bend ,elbow, socket and and also including 1.5 sqmm PVC insulated and PVC unsheathed single core multistranded copper conductor FRLS cable 1100 V grade as earth wire including concealed MS terminal box ISI marked of suitable size / 3 mm thick hylam sheet on MS terminal box for housing switch, socket, regulators etc complete for the following:-
One light point controlled by one switch
One Fan point controlled by one switch
One 5 pin 6 Amps socket outlet on independent board.
One 5 pin 6 Amps socket outlet on same board.
Bell /buzzer point controlled by one push button on the same board with other switches or indipendent with cables 1.5 sqmm size.
One light point controlled by two way switch.
All as per item No 01 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 Volts grade PVC insulated but unsheheted copper conductorFRLS cable 1100 volts grade and 2.5 sqmm PVC insulated but unsheathed FRLS cable as earthwire for 16 Amps power point on independent board complete all as specified and directed by Engr-in-charge.
Supply and fix in repair day to day maintenance switch piano flush type one way 6 Amps complete all as specified and directed.
Supply and fix in repair day to day maintenance switch piano flush type one way 16 Amps complete all as specified and directed.
S & F in repair day to day maintenance electronic step type dimmer scoket type of capacity 120 W 16 Amps all as specified and directed by Engr-in-Charge.
S&F in repair day to day maintenance Bell push, flush type, inreplacement/ repair 6 Amp all as specified and directed by Engr-in-Charge.
S & F in repair day to day maintenance switch piano type two way 6 Amps all as specified and directed by Engr-in-Charge.
S&F Bell push, inreplacement/ repair 6 Amp all as specified and directed by Engr-in-Charge.
S & F in repair day to day maintenance socket outlet 2 in1,3 pin 5 Amps all as specified and directed by Engr-in-Charge.
S & F in reapair day to day maintenance socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type all as specified and directed by Engr-in-Charge.
S & F in repair day to day maintenance switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type all as specified and directed by Engr-in-Charge.
S & F in repair day to day maintenance switch socket combination 2 in 1, 3 pin, 5 Amps flush type all as specified and directed by Engr-in-Charge.
S & F in repair day to day maintenance switch socket combination 2 in 1, 3 pin, 5 and 15 Amps Box type all as specified and directed by Engr-in-Charge.
S & F in repair day to day maintenance switch socket combination 2 in 1, 3 pin, 5 Amps Box type all as specified and directed by Engr-in-Charge.
S&F in repair socket out let 2-in-1,3 pin 6 /16Amps Modular Flush type, (make shall be as per existing) all as directed by Engr- in- Charge.
S&F in repair Switch 16 Amps Modular one Way (make shall be as per existing) all as directed by Engr- in- Charge.
S&F in repair Switch 6 Amps Modular one Way (make shall be as per existing) all as directed by Engr- in- Charge.
S&F in repair scoket 16 Amps Modular Flush type, (make shall be as per existing) all as directed by Engr- in- Charge.
S&F in repair scoket 6 Amps Modular Flush type, (make shall be as per existing) all as directed by Engr- in- Charge.
S&F in repair Fan step regulator, 120W - 2 module Modular (make shall be as per existing) all as directed by Engr- in- Charge.
S & F for sheet metal enclosure MCB DB of following way with 200 Amps rated bus bar 240 volts Double door with magnitic locking system complete all as specified and as directed of following Size. Make : Indo Asian / Standard / L & T
SPN DB 8 way
SPN DB 4 way
SPN DB 12 way
TP DB 6 way with double door
VTP DB 8 Way with Incomer 63-100 Amps 4 pole MCCB
VTP DB 4 Way with Incomer 63-100 Amps 4 pole MCCB
S & F in repairs Single pole and neutral enclosure with a metal two pin and earth plug and metal clad socket complete with one single pole MCB 20 Amps
S & F PVC ceiling rose surface type three terminals type inreplacement/ repair all as specified and directed by Engr-in-Charge.
S & F Buzzer / ding dong AC 230 volts, 6 Amp single Phase in white /Ivory colour finish inreplacement/ repair all as specified and directed
S & F square 600 mm X 600 mm, 36 W - 42 W surface mounted bottom opening LED fitting including, LED Lamp with powder coated CRCA housing and polycarbonate diffuser, LED Fixture system wattage 36 -42 w,140V -260 V AC ,System lumen out put min 3600 lumen in 36 w and 4200 lumen in 42 w with 5700-6500 K CCT with PF>0.95 CRI>=80 and with <=10 % THD, with Min 2.5 KV surge protection in Built complete LED fixture with BIS Mark and R Registration no. Make : Havells / Philips / Surya
S & F 100 Watt LED high bay energy saving environment friendly and robust high bay LED luminaire with high efficiency with toughened glass LED fitting Pressure die cast aluminium alloy for housing (heat sink) for effective thermal management with LED PC lens LED High Bay LED system wattage consist of 100 Watt ,140-260 V AC, System Lumen Out put min 10000-12000 Lumen in 100 w with 5700-6500 K CCT with PF >0.95 CRI >=70 and with <=10 % THD, with Min 2.5 KV Surge protection in Built and LED high Light and BIS R Registration number and necessary brackets , including provision of clamps of suitable size all as specified and diretced. Make : Havells / Wipro / Philips
S & F LED tube along with CRCA LED Batten complete LED light fitting fixture including LED Tube Rod and Batten, LED Tube fitting consist of Polycarbonate housing with extruded aluminium heatsink for mounting LED chip, LED tube system wattage consist of 20 / 22 W, 140-260V AC, system Lumen output min 2000 Lumen in 20 W and 2200 lumen in 22 W with 5700-6500 K CCT with PF>0.95 CRI>=80 and with <=10 % THD, with Min 2.5 KV Surge protection in Built LED Batten consist of powder coated CRCA box type batten with decorative end caps should be supplied for installing above LED tubes Make : Havells / Wipro / Philips
S&F in repair surface and wall mounted LED T5 integrated batten Batten with integrated electronic driver energy efficient 10W LED (Two feet) decorative with working voltage 140-260V AC, system Lumen output min 1100 Lumen in 10 W in 5700-6500 K CCT with PF>0.95 CRI>=80 and with <=10 % THD, with Min 2.5 KV Surge protection in Built LED complete all as specified & directed. Make : Havells / Wipro / Philips
S & F in repairs wall mounted extruded aluminium housing high quality indoor batten LED tube 20 watt colour temperature 6500 K (4' long) lumen 2000 - 3000, PF> 0.9, THD less 15% diffused connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement complete all as directed by Engr-in-charge. Make : Havells / Wipro / Philips
S & F in repairs 20 W ultra bright glass LEDTube Rod of size 4 ft with lumen 2000 to 2200, PF>0.95 , colour temperature 6500 K suitable working in existing batten complete all as specified and directed. Make : Havells / Wipro / Philips
S&F in repairs surface cum recessed mounted down light with white powder coated polycarbonate housing and PC diffuser in white powder coated finish with built in electronic driver. PC diffuser in white powder coated finish with integral electronic of capacity 18 W in size of 292 mm X 292 mm X 15 mm with 6500K PF>/= 0.90 LED THD<20% light fitting complete all as specified and directed. Make : Havells / Wipro / Philips
S&F in repairs surface cum recessed mounted down light with white powder coated polycarbonate housing and PC diffuser in white powder coated finish with built in electronic driver. PC diffuser in white powder coated finish with integral electronic of capacity 12 W in size of 217 mm X 217 mm X 15 mm with 6500K PF>/= 0.90 LED THD<20% light fitting complete all as specified and directed. Make : Havells / Wipro / Philips
Supply and fix in repair ultra bright LED PLL with very high efficacy suited for installation in existing 2G11 lamp holder to give glare free light of capacity 18 watt, 4 pin suitable for existing fitting and complete all as specified and directed Make : HPL / Wipro / Havells
Supply and fix in repair of Driver for 18 W 6500K LED lighting fitting
Supply and fix in repair of Driver for 12 W 6500K LED lighting fitting
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 1.5 sqmm 1100 volt grade drawn into PVC casing caping of size 32 mm including 1.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note : Two runs of 1.5 Sqmm cable, one run of 1.5 Sqmm earth cable and one run of PVC casing caping shall be measured as one unit length Make : Polycab / Anchor / Havells
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 2.5 sqmm 1100 volt grade drawn into PVC casing caping of size 32 mm including 2.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth cable and one run of PVC casing caping shall be measured as one unit length. Make : Polycab / Anchor / Havells
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 1.5 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 1.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note : Two runs of 1.5 Sqmm cable, one run of 1.5 Sqmm earth cable and one run of PVC conduit shall be measured as one unit length. Make : Polycab / Anchor / Havells
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 2.5 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 2.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note : Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth cable and one run of PVC conduit shall be measured as one unit length. Make : Polycab / Anchor / Havells
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 4 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth cable and one run of PVC conduit shall be measured as one unit length. Make : Polycab / Anchor / Havells
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 6 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth cable and one run of PVC conduit shall be measured as one unit length. Make : Polycab / Anchor / Havells
Taking down old submain wiring and M&L for sub main wiring with four single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC conduit of size 25 mm dia including 4 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note: Four single core cable 4 Sqmm, 4 Sqmm earth wire and PVC conduit shall be measured as one length. Make : Polycab / Anchor / Havells
Taking down old submain wiring and M&L for sub main wiring with four single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC conduit size 32mm of suitable size including 6 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Make : Polycab / Anchor / Havells Note: Four single core cable 6 Sqmm, 6 Sqmm earth wire and PVC conduit shall be measured as one unit length.
S&F in repair/replacement in day to day maintenance MCBs /isolators of following capacity. Make : Indo Asian / Standard / L & T
MCB SP 5 to 32 amps,
MCB SPN 10 to 32 Amps
MCB SPN 40 to 63 Amps
TPN 16 To 32 AMP
MCB TPN 40 to 100 Amps
MCCB 3 Pole .415 V. fixed type, 25 to 100 Amps with breaking capacity 16 KA
S &F in replacement lamp holder, Insulated body with back plate for batten fitting
Taking down carefully electric geysers of any make type and capacity after disconnecting of electrical and water connections, opening of bottom cover, checking of all parts and taking out copper/ Stainless steel tank, checking of its leakage and removing the dust, brazing the leakage and painting of geysers with two coats of synthetic enamel painting replacement of worn out spares and reassembling complete , geyser and re-fixing back its position all as directed Note : Spares shall be measured and paid seperately under the relavant items of schedule as supply only.
Supply only thermostats ISI marked as required at site for geyser of capacity 25/35/50 Ltr of any make all as directed by Engr-in-charge
Supply only safety valve/high pressure valve ISI marked as per site requirement or all as per directed by Engineer-in-Charge.
Supply only heating element of rating 1/1.5 KW as required at site including rubber washers all as specified and directed by Engr-in-charge.
S & F in repairs heating element of rating 2 KW as required at site including rubber washers all as specified and directed by Engr-in-charge..
S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection all as specified and directed by Engineer-in-charge.
S & F in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 CM long for hot water connection all as specified and directed by Engineer-in-charge.
S & F in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
S&F in repairs plug top 16 Amps flush type, Complte all as specified by
M & L stop valve, cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore
Taking down carefully ceiling fan of any make, size from its location, dismantling complete fan, examine complete parts thoroughly, servicing, oiling, greasing all parts and complete overhauling of fan including checking of winding, replacement of small parts such as split pin, nut bolt, screw and assembling complete fan and make fully functional with replacemnt of old unsv rewinding with new rewinding of fan , re-fixing the fan to its original position including replacement of three core PVC insulated multi stranded copper wire 0.5 sq mm 1100 Volts grade from fan connector to ceiling rose complete all as directed Note : Ball bearing, bush fan blade etc will be measured and paid seperately under relevant item of schedule as supply only.
Supply only ball bearing(DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-charge. Make : SKF/NBC or equivalent
Supply only capacitor 2.5 mfd for ceiling fan all as specified and as directed by Engr-in-charge Make:Havells/Epcos)
All as per item No 54 above but Exhaust Fan of sweep 275-450 mm
Supply only ball bearing to match the existing make suitable for 275-450 mm exhaust fan inclduing greasing. Make : SKF/NBC or equivalent
Supply only capacitor 4 mfd for exhaust fan all as specified and as directed (Make:Havells/Epcos)
Supply & fix in repairs Aluminium strip 25 mm x 3 mm complete with saddles and fixing screws for fitting the strip all as specified and directed by Engr In Charge.
Supply & fix in repair Aluminium strip/GI 25 mm x 3 mm complete with saddles and fixing screws for fitting the strip all as specified and directed by Engr In Charge.
Supply & fix in replacement /repair Aluminium strip/Galvanised iron strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip all as specified and directed by Engr In Charge.
Fixing in repair aluminium/GI strip 25 mm x 3mm complete with saddles and screws for fitting the strip.
Fixing in repair GI/Aluminium/Copper 20 mm x 3 mm complete with saddles and screws for fitting the strip.
Fixing in repair GI 32 mm x 6 mm complete with saddles and screws for fitting the strip.
M&L for Air terminations single pointed Aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof including taking down old all as directed.
Supply and fix test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. head screw including taking down old all as spcified and directed by Engr- in - Charge.
Material & labour for fixing of 50mm bore GI Pipe medium grade galvanised 1.5 mrt. long fixed on wall with proper fixing and clamping of strip & 1.5 mtr to 300mm long copper/Aluminium lightening arrester rod with all fitting and fixed complete to wall or roof top of bldg. Note: Joints shall be made with welding to get proper conductivity
Material and labour for earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete.
metro electrical services
ONKAR ELECTRIC AND GENERAL STORE
ASHWAMEDH ENGINEERS
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .