Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance A 245 OKHLA INDUSTRIAL AREA PHASE I DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Admitted-Finance |
| 3 | Admitted-Finance 10 DR RADHAKRISHNAN NAGAR ARUMBAKKAM CHENNAI TAMILNADU 600106 | CHENNAI | TAMIL NADU | 600106 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
29 Feb 2024, 6:00 pmClosed
The Director, JIPMER
The Director, JIPMER
RATE CONTRACT for supply of CONSUMABLES/NON-CONSUMABLES for the Department of CTVS
2024_JIPMP_791285_1
JIP/Pur.6(1)/OeT/CTVS/2023-25
Open Tender
Consumables (Hospital / Lab)
Supply
45 days
The Director, Puducherry JIPMER
As per Tender Document
14 documents required · 14 mandatory
₹590
Payable To The Director, JIPMER
₹5,000
Yes
18 Nov 2024
19 Jan 2024
1 Mar 2024
19 Jan 2024
29 Feb 2024
31 Jan 2024
19 Jan 2024 - 24 Jan 2024
CONSUMABLES Note: For items mentioning 'SPR' (Sample Product Required) sample should be submitted. For addition clarification follow the link mentioned below in Instruct No. 6 General instructions: 1. All the consumable items in the list are meant for disposable usage unless specifically mentioned as for 'multiple use' or 'Reusable'. Hence should be supplied in doubly sealed sterile pack 2. The brand name of the item quoted should be mentioned on the pack as well as on the item. 3. The price quoted will be assumed to be only for a sinlge unit of the item. In case the item is available only in a pack of in multiple units, the cost should be clearly mentioned whether it is the cost of the pack or that of a single unit in the pack. 4. The SPR items - if needs to be used for clinical procedure the item can not be returned. If the samples are only for demonstration and needs to be returned, the firm should bring the sample on a specific day for display. 5. The annual quantity requirement mentioned below is only tentative and may change based on the clinical requirement. 6. For the figures mentioned enter the link provided in the next row or copy and paste the following addres.. https://docs.google.com/presentation/d/1eOTc3lgusgBkTstXiIPgE0Y6YZzGVqHqkBR7cjM_IN4/edit?usp=sharing// ABBREVIATIONS: Perfusion Technological Consumables-Abbreviations Used MSA - Membrane surface Area, BFR - Blood Flow rate SPV - Static Priming Volume, CVR - Cardiotomy venous reservoir. PV - Priming volume, BHPSC - Biocompatible hydrophilic polymer surface coating, HE - Heat Exchanger. SS - Stainless Steel SPR - Sample Product required (for wither clinical use or for demo) -
Membrane Oxygenator- Large Adult - Type A MSA = 1.7 to1.8m², Max. BFR = 8L/min, SPV≤ 220ml, CVR ≥ 4500ml, Surface must be coated, Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator- Large Adult - Type B MSA = 1.4 to 1.8m², Max BFR =6 L/min, SPV ≤ 185ml, CVR ≥ 4500ml Coated Surface -Polyurethane HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator- Large Adult - Type C MSA = 1.4 to1.8m², Max BFR = 6 L/min, SPV ≤ 185ml, CVR ≥ 4500ml, Integrated Arterial filter, Surface must be coated, Polyurethane HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator- Small Adult - Type A MSA=1.3 to 1.5 m², Max BFR= 5 L/min, SPV ≤ 175ml, CVR ≥ 4000ml. Biocompatible surface coating preferable. Stainles Steel HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator- Small Adult - Type B MSA = 1.3 to1.5 m², Max BFR =5L /min,SPV ≤ 295ml, CVR ≥ 4000ml. Integrated arterial filter, SS-HE, Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator- Small Adult - Type C MSA= 1.5m², Max BFR= 4 L/min, SPV ≤ 135 ml, Hard shell reservoir capacity 3000-3200ml, Metal HE. Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator- Pediatric - Type A MSA ≤ 1.1m², Max. BFR 2.8 to3.5L/min, SPV ≤ 130ml, CVR ≥ 2500ml, SS- HE integrated with oxygenator. Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator - Pediatric - Type B MSA ≤ 0.8m², Max BFR 2.1 -2.8 L /min, SPV≤ 100ml, CVR ≤ 1500ml, SS-HE integrated with oxygenator. Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator-Pediatric - Type C MSA ≤ 0.67m², Max BFR = 2 L/min, SPV ≤ 48ml. Integrated HE of Terephthalate (PET) Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator- Infant MSA ≤ 0.5m², Max BFR = 1.5 L /min, SPV ≤ 43ml, Integrated SS-HE. Biocompatible hydrophilic polymer surface coating . Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator- Neonate MSA ≤ 0.35m², Max BFR= 1 L /min, SPV ≤ 38ml, integrated SS-HE , Coated surface. Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
Membrane Oxygenator-Dual Chamber CVR integrated with arterial filter MSA = 1.6 to 1.85m², Max BFR -7 L/min, SPV ≤ 350ml, Coated surface, Two-step lipid-leukocytes depletion CVR, Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
ADULT CPB PACK:- a) Membrane Oxygenator with hard shell reservoir – Adult. MSA = 1.4 to1.8m², Max BFR = 8L/min, SPV ≤ 220ml, CVR ≥ 4500ml, Integrated Arterial filter, Polyurethane HE. b) Custom tubing pack –Adult as per JIPMER 2020 Adult Circuit.(DIAGRAM will be Provided) c).Cardioplegia delivery system - 4:1 type PV ≤ 30ml, Max BFR ≥ 2.5 L/min d).Hemofilter- Adult MSA ≤ 0.71m², PV ≤ 65 ml, to be supplied with tubing set & collection bag e).Pressure transducers -Single type for heart lung machine
SMALL ADULT CPB PACK:- a) Membrane Oxygenator with hard shell reservoir –Small adult MSA = 1.3 to1.8m², Max BFR = 6L/min, SPV ≤ 190ml, CVR ≥ 4500ml, Stainless Steel HE. b) Custom tubing pack –Small adult as per JIPMER 2020 Small Adult Circuit.(DIAGRAM will be Provided) c) Cardioplegia delivery system - 4:1 type PV ≤ 30ml, Max BFR ≥ 2.5 L/min d) Hemofilter- Small Adult MSA ≤ 0.71m², PV ≤ 65 ml, To be supplied with tubing set & Collection bag .
PEDIATRIC CPB PACK :- a) Membrane Oxygenator with hard shell reservoir –Pediatric MSA ≤ 0.65m², Max BFR 2 -3 L /min, SPV≤ 130ml, CVR ≤ 1800ml, Stainless Steel HE. b) Pre connected Custom tubing pack –Pediatric As per JIPMER 2020 Paediatric Circuit..(DIAGRAM will be Provided) c) Online Cardioplegia delivery system - 4:1 type PV ≤ 30ml, Max BFR ≥ 2.5 L/min d) Hemofilter- Paediatric- MSA ≤ 0.3m², PV ≤ 35 ml, To be supplied with tubing set & collection bag
NEONATE CPB PACK:- a) Membrane Oxygenator with hard shell reservoir –Neonate MSA ≤ 0.6m², Max BFR 0.5- 1.5 L /min, SPV ≤ 100ml, Integrated Polyurethane HE b) Pre connected Custom tubing pack –Neonate As per JIPMER 2020 Neonatal Circuit. .(DIAGRAM will be Provided) c).Online Cardioplegia delivery system - 4:1 type PV ≤ 30ml, Max BFR ≥ 2.5 L/min with 3-way with purge line. d).Hemofilter- neonate MSA ≤0.1m², PV ≤ 20 ml, To be supplied with tubing set & collection bag
ECMO (ExtaCorporeal Membrane oxygenator) with circuit - Adult: for multipurpose use. MSA ≥1.8m², Max BFR= 7L/min , SPV ≤ 250 ml, RF-32 or Flo Pump32 centrifugal Pump Head, Diiffusion membrane of Polymethylpentene. Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
ECMO oxygenator with circuit - Pediatric- for multipurpose use - MSA ≥1,35m², Max BFR = 3L/min, SPV ≤200 ml. 'RF-32 or FloPump32' centrifugal Pump Head, Polymethylpentene membrane, Primary Pack should be labelled. Holder & Temperature probe to be supplied. Provide the brochure containing the details
ECMO oxygenator with circuit - Neonatal -for multipurpose use MSA ≥ 0.69m², Max BFR= 1.5L/min, SPV ≤90 ml. Polymethyl pentene membrane, 'RF-32 or FloPump32' 3/8 or 1/4 inch inlet & outlet, Holder & Temperature probe to be supplied. Provide the brochure containing the details
Hemofilter- Large Adult MSA ≤ 1.4m², PV ≤ 80 ml, To be supplied with tubing set & collection bag & a suitable holder Primary Pack should be labelled. Provide the brochure containing the details
Hemofilter- Medium Adult MSA = 1.1m², PV ≤ 71 ml, To be supplied with tubing set & collection bag & a suitable holder Primary Pack should be labelled. Provide the brochure containing the details
Hemofilter- Small Adult MSA ≤ 0.71m², PV ≤ 65 ml,To be supplied with tubing set & collection bag & a suitable holder Primary Pack should be labelled. Provide the brochure containing the details
Hemofilter -Pediatric MSA ≤ 0.3m², PV ≤ 35 ml, To be supplied with tubing set & collection bag & a suitable holder. Primary Pack should be labelled. Provide the brochure containing the details
Hemofilter-Infant MSA ≤0.1m², PV ≤ 20 ml, to be supplied with tubing set & collection bag & a suitable holder . Primary Pack should be labelled. Provide the brochure containing the details
Custom pack -Adult - tubing set for CPB as per JIPMER 2023 Circuit. (contact CTVS dept for Figures)
Custom pack -Small Adult -tubing set for CPB as per JIPMER 2023 Circuit. (contact CTVS dept for Figures)
Custom pack -Pediatric tubing set for CPB as per JIPMER 2023 Circuit. (contact CTVS dept for Figures)
Custom pack -Neonatal tubing set for CPB as per JIPMER 2023 Circuit. (contact CTVS dept for circuit diagram)
Cardio plegia delivery system (CPDS) - Reservoir Type with a minimum Reservoir capacity of 2 L with at least 4 x 1/4” ports & holder. Primary Pack should be labelled. Provide the brochure containing the details
Cardio plegia delivery system (CPDS) - 4:1 type PV ≤ 30ml, Max BFR ≥ 2.5 L/min with 3-way with purge line. Preferably with groved stainless steel HE & 150 µm polyester screen filter. Primary Pack should be labelled. Holder to be supplied. Provide the brochure containing the details
Centrifugal pump head - Adult type 1 Vaned Impeller design, 3/8 "inlet & outlet with housing to fit the centrifugal console of heart lung machine of APS-I (Terumo – Sarns) & SORIN S5 (CP5).SPR
Centrifugal pump head - Adult Type 2 Priming Volume ≤ 32ml, 3/8 inch inlet & outlet with housing to fit the centrifugal console of Rotaflow (Maquet). The pump head should be without a metal shaft or seal.SPR
Centrifugal pump head - Pediatric Vaned Impeller design, 1/4" inlet & outlet with housing to fit the centrifugal console of heart lung machine SORIN S5 (CP5). SPR
Intra Aortic balloon (compatible with Arrow IABP machine) 30 to 35 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
Intra Aortic balloon (compatible with Arrow IABP machine)- 40 cc To be supplied with suitable conectors and the kit for femoral insertion of the balloon.
Pressure transducers -Single type for heart lung machine (Sarns & APS-I with 200 cm pressure line & a pressure cable suitable for the device and the machine has to be supplied free of cost with every 100 transducers purchased - Provide the brochure containing the details
Pressure transducers Twin type for anesthesia monitors with 200 cm pressure line, transducer and flush device with a pressure cable (for the pruchase of every 50 transducers) suitable to be connected to GE monitor, SS Med L & T Star 55 monitors. Provide the brochure containing the details
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size A - 3/16" x 3/16".
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size B - 1/4" x 1/4".
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size C - 3/8" x 3/8".
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size D - 1/4" x 3/8".
Straight connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size E - 3/8" x 1/2".
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size A - 1/4" x 1/4" x 1/4"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size B - 1/4" x 1/4" x 3/8"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size C - 3/8" x 3/8" x 3/8"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size D - 3/8" x 3/8" x 1/4"
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size E - 1/2''x 3/8''x 3/8''
Y connectors with female luer lock - Disposable, Sterile, transparent - made up of high quality plastic suitable for cardio- pulmonary bypass circuit with female luer lock. SPR Size F - 1/2''x 1/2''x 3/8''
HTK type - single shot cardioplegia. Histidine – Tryptophan – Ketoglutarate (HTK) type. cardioplegic solution for myocardial protection for at least 3 hours after a single shot of cardioplegia. 1 litre
HTK type - single shot cardioplegia Histidine – Tryptophan – Ketoglutarate (HTK) type. cardioplegic solution for myocardial protection for at least 3 hours after a single shot of cardioplegia. 0.5 litre
Aortic / arterial Perfusion Cannula plain type with Straight tip 8F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 10F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 12F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 14F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 16F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 18F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 20F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 22F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Aortic / arterial Perfusion Cannula plain type with Straight tip 24F Overall length of at least 7 inches with transparent body with tapering contour, tip orientation line and tip guard preferably with vented type connector - SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 6F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 8F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 10F - With elongated thin walled tip - vented type - depth markings -overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 12F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 14F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Pediatric Size 16F - With elongated thin walled tip - vented type - depth markings - overal at least 9 inch long with introducer preferably with guide wire -SPR
Elongated Aortic /arterial Perfusion Cannula - Adult Size 18F - with thin walled vented type tip, introducer & depth markings, radio-opaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire. SPR
Elongated Aortic /arterial Perfusion Cannula - Adult Size 20F - with thin walled vented type tip, introducer & depth markings, radio-opaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire. SPR
Elongated Aortic /arterial Perfusion Cannula - Adult Size 22F - with thin walled vented type tip, introducer & depth markings, radio-opaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire. SPR
Elongated Aortic /arterial Perfusion Cannula - Adult Size 24F - with thin walled vented type tip, introducer & depth markings, radio-opaque adjustable suture collar -overal length of at least 12 inch long preferably with guidewire. SPR
Venous Return Cannula- single stage- straight 12F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 14F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 16F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 18F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 20F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 22F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 24F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 26F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 28F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 30F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula- single stage- straight 32F multiport tapered tip & kink resistant wirewound body- length of at least 12 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 10F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 12F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 14F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 16F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 18F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 20F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 22F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 24F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 26F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula - single stage -- right angled metal 28F multiport tip with kink resistant wirewound body- tip orientation line over all length of at least 14 inch long - SPR
Venous Return Cannula-Cuffed single stage - 37F - wirewound body at least 35 cm long with inflatable cuff - SPR
Venous return cannula -Two Stage flat body- 28/36F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 29/37F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 32/40F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 36/46F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 34/46F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Venous return cannula -Two Stage flat body- 36/51F - thin walled - with multi-ported tips & atrial basket - wirewound with depth markings with overall length of at least 38 cm - SPR
Femoral Arterial Perfusion cannula (Pediatric) - 8F with depth marking, introducer with central lumen - SPR
Femoral Arterial Perfusion cannula (Pediatric) - 10F with depth marking, introducer with central lumen - SPR
Femoral Arterial Perfusion cannula (Pediatric) - 12F with depth marking, introducer with central lumen - SPR
Femoral Arterial Perfusion cannula (Pediatric) - 14F with depth marking, introducer with central lumen - SPR
Femoral Arterial Perfusion cannula (Adult) - 15F or 16F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 17F or 18F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 19F or 20F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 21F or 22F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 23F or 24F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Arterial Perfusion cannula (Adult) - 25F or 26F - with overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire ( .038“ ) and vented connector - SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 8F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 10F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 12F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 14F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 15F or 16F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 17F or 18F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 19F or 20F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 21F or 22F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 23F or 24F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 25F or 26F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 27F or 28F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Single-stage Drainage cannula (Pediatric) - 29F or 30F -with wire wound body & depth markings - overal length of at least 19 cm - with an introducerand preferably with a guidewire SPR
Femoral Venous Dual Stage Drainage cannula (Adult) 21F of Carpentier type of at least 65 cm with depth marking- -with two sets of bicaval side ports with an intervening transition zone - Should also have an introducer with an elongated tapered tip and preferably with a guide wire. - SPR
Femoral Venous Dual Stage Drainage cannula (Adult) 23F of Carpentier type of at least 65 cm with depth marking- -with two sets of bicaval side ports with an intervening transition zone - Should also have an introducer with an elongated tapered tip and preferably with a guide wire. - SPR
Femoral Venous Dual Stage Drainage cannula (Adult) 25F of Carpentier type of at least 65 cm with depth marking- -with two sets of bicaval side ports with an intervening transition zone - Should also have an introducer with an elongated tapered tip and preferably with a guide wire. - SPR
Femoral Venous Dual Stage Drainage cannula (Adult) 27F of Carpentier type of at least 65 cm with depth marking- -with two sets of bicaval side ports with an intervening transition zone - Should also have an introducer with an elongated tapered tip and preferably with a guide wire. - SPR
Dual lumen Venous Cannula sizes from 19 F to 31 F for venovenous ECMO. Only one set of different sizes will be purchased initially and the subsequent sets will be purchased based on S.O.S.
Minimally invasive vascular access Kit for femoral arterial cannulation for CPB or ECMO with Scalpel (#11), Seldinger Needle (18G) Stepped vessel dilator - 8 F/10 F, 12 F/14 F & 16 F/18 F, Guidewire - 0.038" (0.965-mm) -100 cm long -for cannulation - SPR
Minimally invasive vascular access kit for femoral venous Cannulation for CPB or ECMO With Scalpel (#11), Seldinger Needle (18G) Stepped vessel dilator - 8 F/10 F, 12 F/14 F and 16 F/18 F, Guidewire - 0.038" (0.965-mm) -180 cm long- SPR
Guidewire -about 0.02 inch ( 0.5 mm) in diameter at least 30 cm long - to pass through 18G needle
Guidewire about - 0.043 inch (1.1 mm) in diameter at least 40 cm long - to pass through 16G needle
Multiple perfusion adapter set with 4 legs with individual tubing clamps for simultaneous perfusion of venous grafts and aortic root - with female luer inlet & male luer outlets preferably with length of- at least 10" (Contact CTVS dept for fig.) SPR.
Cardio-plegic Cannula-Antegrade 3F (18G) with introducer needle, standard tip preferably with side holes Length 5-8cm SPR
Cardio-plegic Cannula-Antegrade 4F with introducer needle, standard tip preferably with side holes Length 5-8cm - SPR
Cardio-plegic Cannula-Antegrade 5F (16G) with introducer needle, standard tip preferably with side holes - SPR
Cardio-plegic Cannula-Antegrade 6F or 7F (14G) with introducer needle, standard tip preferably with side holes - SPR
Cardio-plegic Cannula-Antegrade 8F or 9F (12G) with introducer needle, standard tip preferably with side holes - SPR
Cardioplegic Cannula-Antegrade with side limb - 4F with introducer needle, standard tip preferably with side holes and a side limb for venting - SPR
Cardioplegic Cannula-Antegrade with side limb - 5F (16G) with introducer needle, standard tip preferably with side holes and a side limb for venting - SPR
Cardioplegic Cannula-Antegrade with side limb - 6F or 7F (14G) with introducer needle, standard tip preferably with side holes and a side limb for venting - SPR
Cardioplegic Cannula-Antegrade with side limb - 8F or 9F (12G) with introducer needle, standard tip preferably with side holes and a side limb for venting - SPR
Cardioplegia cannula -Minimally Invasive Antegrade type with long body of at least 30 cm and an introducer needle with standard tip length
Cardioplegia cannula - Flexible Coronary Ostial straight tip about 2 mm with soft silicone bulb /balloon of 12F (4mm) near the end -SPR
Cardioplegia cannula - Flexible Coronary Ostial straight tip about 2 mm with soft silicone bulb /balloon of 15F (5mm) near the end -SPR
Cardioplegia cannula - Flexible Coronary Ostial straight tip about 3 mm with soft silicone bulb /balloon of 18F (6mm) near the end -SPR
Cardioplegia cannula - Flexible Coronary Ostial straight tip about 3 mm with soft silicone bulb /balloon of 21F (7mm) near the end -SPR
Cardioplegia cannula - Flexible Coronary Ostial straight tip about 3.5 mm with soft silicone bulb /balloon of 24F (8mm) near the end -SPR
Cardioplegia cannula - Flexible Coronary Ostial Tapering tip with soft self-inflating ballooon -tip tapering from 27F (9mm) to 8F (2.7mm) and body encapsulated with malleable wire- SPR
Cardioplegia cannula - Rigid 45º angled Left Coronary Ostial type with basket tip -10F (3.3mm) SPR
Cardioplegia cannula - Rigid 45º angled Left Coronary Ostial type with basket tip -12F (4 mm) SPR
Cardioplegia cannula - Rigid 45º angled Left Coronary Ostial type with basket tip -14F (4.7 mm) SPR
Cardioplegia cannula - Rigid 80-90º angled Right Coronary Ostial type with basket tip -10F (3.3 mm) SPR
Cardioplegia cannula - Rigid 80-90º angled Right Coronary Ostial type with basket tip -12F (4 mm) SPR
Cardioplegia cannula - Rigid 80-90º angled Right Coronary Ostial type with basket tip -14F (4.7 mm) SPR
Retrograde cardioplegia cannula 6F ( for Coronary sinus) with silicone bodies and manually inflatable cuffs with pressure monitoring line , smooth cuff SPR
Retrograde cardioplegia cannula 9-10F ( for Coronary sinus) with silicone bodies and manually inflatable cuffs with pressure monitoring line , smooth cuff and preferably with a guidewire stylet. -SPR
Retrograde cardioplegia cannula 13F (for Coronary sinus) with auto-inflatable cuff with Solid Stylet & integral stop cock for pressure monitoring - Preferably with wirewound body - SPR
Retrograde cardioplegia cannula 15F (for Coronary sinus) with auto-inflatable cuff with Solid Stylet & integral stop cock for pressure monitoring - Preferably with wirewound body - SPR
Cardiac suction tip- (Mini sucker) soft flexible tapered tip 9F (3mm) - with angled shaft - SPR
Cardiac suction tip- (Mini sucker) soft flexible tapered tip - 12F (4mm) - with angled shaft - SPR
Intra-cardiac suction tip- Rigid - 20F (6.7mm) fluted pool tip - with 16F (5.3mm) - angled metal shaft at least 15 cm long - SPR
Frazier tip- suction1:small & short 6F tip & shaft about 7.5cm long-SPR
Frazier tip- suction 2:small & long 6F tip & shaft - about 15cm long - SPR
Frazier tip- suction 3 - Large -10 F tip & shaft - about 10 cm long - SPR
Intracardiac / pericardial sump suction Type 1: 20 F tip with metal weighted perforated pool tip & flexible tubing at least 30 cm long - SPR
Intracardiac / pericardial sump suction Type 2: 12 F tip with metal weighted perforated pool tip & flexible tubing at least 20 cm long - SPR
Intracardiac / pericardial sump suction Type 3: 12 to 15 F tip with spring encased fluted pool tip & flexible tubing at least 20 cm long terminating into a 1/4" connector - SPR
Intracardiac / pericardial sump suction Type 4: 20 F tip with spring encased fluted pool tip & flexible tubing at least 30 cm long terminating into a 1/4" connector - SPR
Disposable Yankur suction cannula with transparent connecting tube of at least 1 meter long - SPR
Left Heart Vent Catheter (type 1) PVC tip with malleable body 10F (3.3 mm) with vented connector - SPR
Left Heart Vent Catheter (type 1) PVC tip with malleable body 13F (4.3 mm) with vented connector - SPR
Left Heart Vent Catheter (type 1) PVC tip with malleable body 15F (5 mm) with vented connector - SPR
Left Heart Vent Catheter (type2) Silicone tip with malleable introducer 16F (5.3 mm)- SPR
Left Heart Vent Catheter (type2) Silicone tip with malleable introducer 20F (6.7 mm)- SPR
Left atrial pressure monitoring catheter - 3F (1mm) = 20 G set of at least 50 cm long with depth markings, attached to a female luer, peelaway needle tip and a self adhesive anchoring collar for securing the catheter at the desired location - SPR.
Left atrial pressure monitoring catheter - 4F (1.43mm) = 17 G set of at least 50 cm long with depth markings, attached to a female luer, peelaway needle tip and a self adhesive anchoring collar for securing the catheter at the desired location - SPR.
Left atrial pressure monitoring catheter - 5F (1.7mm) = 15 G set of at least 50 cm long with depth markings, attached to a female luer, peelaway needle tip and a self adhesive anchoring collar for securing the catheter at the desired location - SPR.
Red rubber latex catheters - 8F/3F for vessel snugging - High quality and tension resistant body - at least 16" long overall. -SPR
Vascular tourniquet (Snugger) set Adult (7" long) for open heart surgery - color coded 4 tubes with one snare- for snugging the purse string sutures during open heart procedures - SPR
Vascular tourniquet (Snugger) set Pediatric (6" long) for open heart surgery - color coded 4 tubes with one snare- for snugging the purse string sutures during open heart procedures - SPR
Silicone vessel (vascular) loop Large size - -2 to 2.5 mm wide & < 1.2 mm at least 40 cm long - medical grade radioopaque silicone loop . for encircling the blood vessels during dissection. -SPR
Silicone vessel (vascular) loop Large size - 1 to 1.3 mm wide & < 1 mm at least 40 cm long - medical grade radioopaque silicone loop . for encircling the blood vessels during dissection. -SPR
Silicone vessel (vascular) loop Large size - 0.5 mm wide & < 0.4 mm at least 40 cm long - medical grade radioopaque silicone loop . for encircling the blood vessels during dissection. -SPR
Air-cushioned - Silicone vessel (vascular) loop with needle - medical grade silicone loop with hollow interior for the air-cushion effect - with the maximum diameter of the loop <1.3 mm (thickness) and at least 25 cm long- SPR
Temporary Epi-myocardial Pacing wire - Adult type - at least 60 cm long for intraoperative placement during cardiac surgery- Incorporating a straight cutting needle of at least 60 mm long with ‘breakaway’ feature enabling the remaining butt to be used as a connecting plug to the Pace maker. The other end of the wire should have 25 to 27 mm tapercut 1/2 circle needle -SPR
Temporary Epi-myocardial Pacing wire - Pediatric type - at least 60 cm long for intraoperative placement during cardiac surgery- Incorporating a straight cutting needle of at least 60 mm long with ‘breakaway’ feature enabling the remaining butt to be used as a connecting plug to the Pace maker. The other end of the wire should have 16 to 18 mm tapercut 1/2 circle needle -SPR
Coronary shunts (silicon type) 1 mmm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Coronary shunts (silicon type) 1.25 mmm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Coronary shunts (silicon type) 1.5 mmm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Coronary shunts (silicon type) 1.75 mmm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Coronary shunts (silicon type) 2 mm - for intra-operative use for CABG (Coronary Artery Bypass Graft) – with beveled & bulbed tips –with 14 mm long & clear shaft. SPR
Aortic -Vascular Punch 3 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
Aortic -Vascular Punch 3.5 mm - with smooth telescoping movement & adequate finger grip mechanism. SPR
Angled Disposable Bull Dog Type Vascular clamp- Type A with clamping pressure of 10-15G used for CABG. . Should be radiopaque & light weight with atraumatic jaw types - SPR .
Angled Disposable Bull Dog Type Vascular clamp- Type B with clamping pressure of 20-25G used for CABG. . Should be radiopaque & light weight with atraumatic jaw types - SPR .
Angled Disposable Bull Dog Type Vascular clamp- Type C with clamping pressure of 75-80G used for CABG. . Should be radiopaque & light weight with atraumatic jaw types - SPR .
Angled Disposable Bull Dog Type Vascular clamp- Type D with clamping pressure of 165-175G used for CABG. Should be radiopaque & light weight with atraumatic jaw types - SPR .
Suction based Cardiac Stabilizer - Retracting arm unit type (Octopus like) for OPCAB (off pump coronary artery bypass). The retracting arms unit should have surgeon controlled pod-spread, allowance for multiple device positions including pods-up, pods-down and pods-to-the-side applications, one-handed engagement of clamp and turret assembly.
Suction based Cardiac Stabilizer - Apex positioner (Starfish like) for OPCAB (off pump coronary artery bypass). Should enhance lifting the apex of the heart and fixing to any positon.
Mist blowing device for OPCAB (off pump coronary artery bypass). With fluid/gas mixing technology creating a consistent, predictable blood clearing mist. On/off control in hand-piece - Malleable shaft - Specialized nozzle, utilizing a micro-orifice for fluid delivery and a separate orifice for gas delivery - Brochure with details and figure to be submitted.
Vessel cannula - 3 mm tip - with stepped contour - transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm SPR. transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm SPR.
Vessel cannula - 2 mm tip - with stepped contour - transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm SPR. transparent body & a female luer at one end for checking the patency and leak in the harvested grafts - length about 5 cm SPR.
IMA (Internal Mammary Arterial) cannula -1mm - with bulb shaped tip for checking patency of the artery
Arteriotomy cannula - 2 mm with polyurethane tube with a bulb shaped tip connected to a winged female luer about 5 cm long - SPR
Arteriotomy cannula - 3 mm with polyurethane tube with a bulb shaped tip connected to a winged female luer about 5 to 8cm long - SPR
Arteriotomy cannula - 4 mm with polyurethane tube with a bulb shaped tip connected to a winged female luer about 5 to 8 cm long - SPR
Arteriotomy cannula - 5 mm with polyurethane tube with a bulb shaped tip connected to a winged female luer about 5 to 8 cm long - SPR
Tilting Disc Aortic valve 18/19 mm. The valve should be rotatable after seating. Valve to be supplied with a suitable holder. (Two sets of reusable valve sizer & valve tester have to be suppied with suitable trays irrespective of the number of valves purchased for the year)
Tilting Disc Aortic valve 20/21 mm. The valve should be rotatable after seating. Valve to be supplied with a suitable holder. (Two sets of reusable valve sizer & valve tester have to be suppied with suitable trays irrespective of the number of valves purchased for the year)
Tilting Disc Aortic valve 22/23 mm. The valve should be rotatable after seating. Valve to be supplied with a suitable holder. (Two sets of reusable valve sizer & valve tester have to be suppied with suitable trays irrespective of the number of valves purchased for the year)
Tilting Disc Aortic valve 24/25 mm. The valve should be rotatable after seating. Valve to be supplied with a suitable holder. (Two sets of reusable valve sizer & valve tester have to be suppied with suitable trays irrespective of the number of valves purchased for the year)
Tilting Disc Mitral valve 25/26 mm. The valve should be rotatable after seating. Valve to be supplied with a suitable holder. (Two sets of reusable valve sizer & valve tester have to be suppied with suitable trays irrespective of the number of valves purchased for the year)
Tilting Disc Mitral valve 27/28 mm. The valve should be rotatable after seating. Valve to be supplied with a suitable holder. (Two sets of reusable valve sizer & valve tester have to be suppied with suitable trays irrespective of the number of valves purchased for the year)
Tilting Disc Mitral valve 29/30 mm. The valve should be rotatable after seating. Valve to be supplied with a suitable holder. (Two sets of reusable valve sizer & valve tester have to be suppied with suitable trays irrespective of the number of valves purchased for the year)
Tilting Disc Mitral valve 31/32 mm. The valve should be rotatable after seating. Valve to be supplied with a suitable holder. (Two sets of reusable valve sizer & valve tester have to be suppied with suitable trays irrespective of the number of valves purchased for the year)
Bileaflet Aortic valve 16/17 mm To be supplied with a suitable holder, sizer and leaflet tester have to be suppied along with the valve.
Bileaflet Aortic valve 18/19 mm To be supplied with a suitable holder, sizer and leaflet tester have to be suppied along with the valve.
Bileaflet Aortic valve 20/21 mm To be supplied with a suitable holder, sizer and leaflet tester
Bileaflet Aortic valve 22/23 mm To be supplied with a suitable holder, sizer and leaflet tester
Bileaflet Aortic valve 24/25 mm To be supplied with a suitable holder, sizer and leaflet tester
Bileaflet Aortic valve 26/27 mm To be supplied with a suitable holder, sizer and leaflet tester
Bileaflet Mitral valve 15/16/17 mm To be supplied with the suitable holder, sizer and leaflet tester.
Bileaflet Mitral valve 18/19 mm To be supplied with the suitable holder, sizer and leaflet tester.
Bileaflet Mitral valve 20/21 mm To be supplied with the suitable holder, sizer and leaflet tester.
Bileaflet Mitral valve 22/23 mm To be supplied with the suitable holder, sizer and leaflet tester.
Bileaflet Mitral valve 24/25 mm To be supplied with the suitable holder, sizer and leaflet tester.
Bileaflet Mitral valve 26/27 mm To be supplied with the suitable holder, sizer and leaflet tester.
Bileaflet Mitral valve 28/29 mm To be supplied with the suitable holder, sizer and leaflet tester.
Bileaflet Mitral valve 30/31 mm To be supplied with the suitable holder, sizer and leaflet tester.
Bovine pericardial stented bioprosthetic aortic valve 19/20 mm with lowest profile height & lowest stent base. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 21/22 mm with lowest profile height & lowest stent base. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 23/24 mm with lowest profile height & lowest stent base. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 25/26 mm with lowest profile height & lowest stent base. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 27/28 mm with lowest profile height & lowest stent base. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic aortic valve 29/30 mm with lowest profile height & lowest stent base. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic mitral valve 25/26 mm with lowest profile height & lowest stent base -with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic mitral valve 27/28 mm with lowest profile height & lowest stent base -with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic mitral valve 29/30 mm with lowest profile height & lowest stent base -with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic mitral valve 31/32 mm with lowest profile height & lowest stent base -with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine pericardial stented bioprosthetic mitral valve 33/34 mm with lowest profile height & lowest stent base -with asymmetric design to position the posterior strut away from LV wall. To be supplied with holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 19/20 mm of the with lowest profile height & lowest stent base. To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 21/22 mm of the with lowest profile height & lowest stent base. To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 23/24 mm of the with lowest profile height & lowest stent base. To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 25/26 mm of the with lowest profile height & lowest stent base. To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 27/28 mm of the with lowest profile height & lowest stent base. To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic aortic valve 29/30 mm of the with lowest profile height & lowest stent base. To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic mitral valve 25/26 mm of the with lowest profile height & lowest stent base with asymmetric design to position the posterior strut away from LV wall To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic mitral valve 27/28 mm of the with lowest profile height & lowest stent base with asymmetric design to position the posterior strut away from LV wall To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic mitral valve 29/30 mm of the with lowest profile height & lowest stent base with asymmetric design to position the posterior strut away from LV wall To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic mitral valve 31/32 mm of the with lowest profile height & lowest stent base with asymmetric design to position the posterior strut away from LV wall To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Porcine stented bioprosthetic mitral valve 33/34 mm of the with lowest profile height & lowest stent base with asymmetric design to position the posterior strut away from LV wall To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic vavled conduit 19/20 mm for Aortic Root and valve replacement (Bentall Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic vavled conduit 21/22 mm for Aortic Root and valve replacement (Bentall Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic vavled conduit 23/24 mm for Aortic Root and valve replacement (Bentall Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic vavled conduit 25/26 mm for Aortic Root and valve replacement (Bentall Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic vavled conduit 27/28 mm for Aortic Root and valve replacement (Bentall Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Stentless bioprosthetic vavled conduit 29/30 mm for Aortic Root and valve replacement (Bentall Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine Jugular Bioprosthetic Valved conduit 12/13 mm for Right ventricle to pulmonary arterial connection (Rastelli Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine Jugular Bioprosthetic Valved conduit 14/15 mm for Right ventricle to pulmonary arterial connection (Rastelli Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine Jugular Bioprosthetic Valved conduit 16/17 mm for Right ventricle to pulmonary arterial connection (Rastelli Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine Jugular Bioprosthetic Valved conduit 18/19 mm for Right ventricle to pulmonary arterial connection (Rastelli Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Bovine Jugular Bioprosthetic Valved conduit 20/21 mm for Right ventricle to pulmonary arterial connection (Rastelli Operation) To be supplied with a holder & sizer set. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned)
Prosthetic Composite Aortic Valved Conduit (for Bentall operation) - with 18/19 mm bileaflet valve mounted on to a collagen impregnated woven polyester (or other synthetic) tube grafts. Should be supplied with a valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned) Only 1 number in each size will be in the shelf and purchased as a set during the first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduit (for Bentall operation) - with 20/21 mm bileaflet valve mounted on to a collagen impregnated woven polyester (or other synthetic) tube grafts. Should be supplied with a valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned) Only 1 number in each size will be in the shelf and purchased as a set during the first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduit (for Bentall operation) - with 22/23 mm bileaflet valve mounted on to a collagen impregnated woven polyester (or other synthetic) tube grafts. Should be supplied with a valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned) Only 1 number in each size will be in the shelf and purchased as a set during the first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduit (for Bentall operation) - with 24/25 mm bileaflet valve mounted on to a collagen impregnated woven polyester (or other synthetic) tube grafts. Should be supplied with a valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned) Only 1 number in each size will be in the shelf and purchased as a set during the first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduit (for Bentall operation) - with 26/27 mm bileaflet valve mounted on to a collagen impregnated woven polyester (or other synthetic) tube grafts. Should be supplied with a valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned) Only 1 number in each size will be in the shelf and purchased as a set during the first purchase - as a stock for emergency
Prosthetic Composite Aortic Valved Conduit (for Bentall operation) - with 28/29 mm bileaflet valve mounted on to a collagen impregnated woven polyester (or other synthetic) tube grafts. Should be supplied with a valve holder, valve sizer & cauterizing loop for creating perforation in the graft. Purchase will be made on the day of surgery - i.e. S.O.S. on consignment basis (different sizes are brought for a procedure - payment will be effected for the size utilized - the other size valves will be returned) Only 1 number in each size will be in the shelf and purchased as a set during the first purchase - as a stock for emergency
Ophthalmic cautery pen - sterile , disposable & battery operated for making perfect holes in the prosthetic vascular grafts
Annuloplasty complete ring for mitral valve. Size : 23/24 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary. A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 25/26 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary. A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 27/28 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary. A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 29/30mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary . A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 31/32 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary. A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 33/34 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary . A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty complete ring for mitral valve. Size : 35/36 mm Near anatomical contour with asymmetric remodelling design. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary. A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 25/26 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 27/28 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 29/30 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 31/32 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 33/34 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 35/36 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 37/38 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Annuloplasty ring for Tricuspid valve incomplete ring type - (largest inner diameter being: 39/40 mm. Near anatomical contour with downward angle at septal end. Should be supplied with suitable holder & sizer. Purchase will be made individually whenever necessary - S.O.S. on consignment basis (i.e different sizes are brought for a procedure - payment will be effected for the size utilized - the other size will be returned) A set of one number in each size will be purchase at first and remain in the shelf for emergency.
Valve Suture guide / Suture-grip / Suture-organizer of Gabbay Frater mechanism for heart valve operations. Curved profile with capacity to hold at least 8 paired sutures with positional numbering labelled in a guide with fixation ports. Each sterile pack should contain 3 such guides.
Arterial embolectomy catheter 2Fx60 cm enclosed in a rigid case-SPR
Arterial embolectomy catheter 3Fx80 cm enclosed in a rigid case-SPR
Arterial embolectomy catheter 5Fx80 cm enclosed in a rigid case-SPR
Arterial embolectomy catheter 7Fx80 cm enclosed in a rigid case-SPR
PTFE vascular tube grafts 3 mm x 10 cm - thin walled
PTFE vascular tube grafts 3.5 mm x 10 cm - thin walled
PTFE vascular tube grafts 4 mm x 10 cm - thin walled
PTFE vascular tube grafts 4.5 mm x 10 cm - thin walled
PTFE vascular tube grafts 3 mm x 10 cm - thin walled
PTFE vascular tube grafts 6 mm x 10 cm
PTFE vascular tube grafts 7 mm x 10 cm
PTFE vascular tube grafts 8 mm x 10 cm
PTFE vascular tube grafts 6 mm x 30 cm
PTFE vascular tube grafts 7 mm x 30 cm
PTFE vascular tube grafts 8 mm x 30 cm
PTFE vascular tube grafts 12 mm x 30 cm
PTFE vascular tube grafts 14 mm x 30 cm
PTFE vascular tube grafts 16 mm x 30 cm
PTFE vascular tube grafts 18 mm x 30 cm
PTFE vascular tube grafts 20 mm x 30 cm
PTFE vascular tube grafts 22 mm x 30 cm
PTFE vascular tube grafts 24 mm x 30 cm
PTFE vascular tube grafts 5 mm x 50 cm
PTFE vascular tube grafts 6 mm x 50 cm
PTFE vascular tube grafts 7 mm x 50 cm
PTFE vascular tube grafts 8 mm x 50 cm
PTFE vascular tube grafts with external support (ringed) 6 mm x 70cm
PTFE vascular tube grafts with external support (ringed) 7mm x 70cm
PTFE vascular tube grafts with external support (ringed) 8 mm x 70cm
Axillo-bifemoral PTFE vascular tube grafts -8 mm diameter & length of 90 cm plus 50 cm. Purchase will be made individually whenever necessary - S.O.S.
Cuffed ePTFE graft with trim line of 4-6 mm x 60 cm - for ananstamosis with the small recepient vessel of size - 3mm & less. Preferably with in-built antiplatelet / antithrombotic mechanism.
Cuffed ePTFE graft with trim line of 4-6 mm x 90 cm - for ananstamosis with the small recepient vessel of size - 3mm & less. Preferably with in-built antiplatelet / antithrombotic mechanism.
AV access ePTFE graft - 6mm x 40 cm designed specially for for creating AV fistual creation for hemodialysis. The graft should be able to withstand multiple needle punctures without bleeding after the needle is removed.
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 6 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 7 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 8mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 10 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 12 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 14 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 16 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 18 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 20 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 22mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 24 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 26mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 28 mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 30mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 32mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 34mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 36mm x 15 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 6 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 7 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 8mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 10 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 12 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 14 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 16 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 18 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 20 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 22mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 24 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 26mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 28 mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 30mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 32mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 34mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 36mm x 30 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 6 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 7 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 8mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 10 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 12 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 14 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 16 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 18 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 20 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 22mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 24 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 26mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 28 mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 30mm x 60 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 6 mm x 90 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 7 mm x 90 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size :10 mm x 90 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 12 mm x 90 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 14 mm x 90 cm
Vascular Graft -Straight - Polyester with Collagen Impregnated fabric with crimps - Size : 16 mm x 90 cm
Vascular Graft - bifurcated with Y limbs - Polyester with Collagen Impregnated fabric with crimps - Size : 12mm x 6 mm - 40-50 cm
Vascular Graft - bifurcated with Y limbs - Polyester with Collagen Impregnated fabric with crimps - Size : 14 mm x 7 mm - 40-50 cm
Vascular Graft - bifurcated with Y limbs - Polyester with Collagen Impregnated fabric with crimps - Size : 16 mm x 8 mm - 40-50 cm
Vascular Graft - bifurcated with Y limbs - Polyester with Collagen Impregnated fabric with crimps - Size : 18 mm x 9 mm - 40-50 cm
Vascular Graft - bifurcated with Y limbs - Polyester with Collagen Impregnated fabric with crimps - Size : 20 mm x 6 mm - 40-50 cm
Polyester fiber suture / ligature 5 mm x at least 40 cm (for Pulmonary arterial banding) SPR
ePTFE Sutures for valve repairs Double armed –90 cm with taper point 3/8 circle needles -in terms of tensile strength suture the size : 4-0
ePTFE Sutures for valve repairs Double armed –90 cm with taper point 3/8 circle needles -in terms of tensile strength suture the size : 5-0
ePTFE Sutures for valve repairs Double armed –90 cm with taper point 3/8 circle needles -in terms of tensile strength suture the size : 6-0
Polybutester suture With polytribolate coating Size 7-0 x 60 cm with 3'/8 circle 8mm needle with the property of needle hole self-sealing for vascular anastamoses.
Polyester patch-Type A (Woven fabric)- 0.25 mm thick- 5cm x10 cm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch-Type A (Woven fabric)- 0.25 mm thick- 10cm x10 cm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch-Type A (Woven fabric)- 0.25 mm thick- 15cm x15 cm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch -Type B (Woven fabric) 0.36 mm thick- 6 mm x 75mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch -Type B (Woven fabric) 0.36 mm thick- 8 mm x 75mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch -Type B (Woven fabric) 0.36 mm thick-8mm x150 mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch -Type B (Woven fabric) 0.36 mm thick-25mm x75 mm Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch-Type B - 0.36 mm thick -25mm x150 mm (Woven fabric) - Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C -0.44 mm thick -25 mm x 50 mm- (Woven fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C -0.44 mm thick -25 mm x 100 mm- (Woven fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C -0.44 mm thick -50 mm x 50 mm- (Woven fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C -0.44 mm thick -75 mm x 75 mm- (Woven fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type C -0.44 mm thick -100 mm x 100 mm- (Woven fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D - 0.61 - 0.65 mm thick - Size: 6 mm x 75 mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61 - 0.65 mm thick size: 10 mm x 140 mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61 - 0.65 mm thick size: 20 mm x 140 mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61 - 0.65 mm thick size: 25 mm x 50 mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61 - 0.65 mm thick size: 25 mm x 75 mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61 - 0.65 mm thick size: 25 mm x 100 mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61 - 0.65 mm thick size: 25 mm x 150 mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61 - 0.65 mm thick size: 50 mm x 50 mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61 - 0.65 mm thick size: 50 mm x 75mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61-0.65 mm thick size: 50 mm x 150mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61-0.65 mm thick size: 75 mm x 75mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch- Type D- 0.61-0.65 mm thick size: 100 mm x 100mm- (Woven fabric) -The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type E - 0.46 mm thick - Size : 25mm x 150 mm (Double velour - Woven fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type E - 0.46 mm thick - Size : 50mm x 75 mm (Double velour - Woven fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type E - 0.46 mm thick - Size : 50mm x 150 mm (Double velour - Woven fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 6 mm x 75 mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 6 mm x 120 mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 8 mm x 75mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 8 mm x 150mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 25 mm x 75mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 25 mm x 150mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 15 mm x 50mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 30 mm x 60mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 15 mm x 70mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 40 mm x 80mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 15 mm x 100mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 40 mm x 120mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type F - 0.76 mm thick. Size: 80 mm x 120mm. (Double velour - knitted fabric) Preferably collagen coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G -1.5 mm thick- 25 mm x 50 mm (Double velour - knitted fabric) as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G -1.5 mm thick- 25 mm x 100 mm (Double velour - knitted fabric) as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G -1.5 mm thick- 50 mm x 50 mm (Double velour - knitted fabric) as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G -1.5 mm thick- 50 mm x 100 mm (Double velour - knitted fabric) as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester patch - Type G -1.5 mm thick- 100 mm x 100 mm (Double velour - knitted fabric) as used for closure of large VSD. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PET (polyethylene Pteriphthalate) patch about 8 mm x 75 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
PET (polyethylene Pteriphthalate) patch about 25 mm x 75 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
PET (polyethylene Pteriphthalate) patch about 25 mm x 150 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
PET (polyethylene Pteriphthalate) patch about 50 mm x 75 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
PET (polyethylene Pteriphthalate) patch about 50 mm x 150 mm - aldehyde-free. Gel coated. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 20 mm x 30 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 20 mm x 75 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 15 mm x 20 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 8 mm x 30 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 6 mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 8 mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 10 mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type A. (0.3 mm thick) - 20 mm x 90mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 8mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 10 mm x 90 mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 25mm x 150mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 30mm x 30mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 30mm x 60mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE Trilaminar patch - Type B. (0.5 mm thick) - 50mm x 75mm Made up of triple layers ( ePTFE layers with middle layer of thermoplastic fluropolymer with elastic property). The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type C (0.4 mm thick) - 10 mm x 90 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type C (0.4 mm thick) - 20 mm x 90 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type C (0.4 mm thick) - 30 mm x 60 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 30 mm x 30 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 50 mm x 75 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 25 mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 50 mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
ePTFE patch - Type D (0.58 to 0.62 mm thick) 100 mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE patch (0.9 mm thick) 50 mm x100 mm for outflow tract. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE patch (0.9 mm thick) 100 mm x100 mm for outflow tract. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE patch (0.9 mm thick) 150 mm x150 mm for outflow tract. The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Polyester Felt 1.65 mm thick - 150mm x 150 mm The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE Felts - 1.65 mm thick - 12 mm x 100 mm
PTFE Felts - 1.65 mm thick - 25 mm x 25 mm
PTFE Felts - 1.65 mm thick - 25 mm x 100 mm
PTFE Felts - 1.65 mm thick - 25 mm x 150 mm
PTFE Felts - 1.65 mm thick - 50 mm x 50 mm
PTFE Felts - 1.65 mm thick - 100 mm x 100 mm
PTFE Felts - 1.65 mm thick - 150 mm x 150 mm
PTFE Felt with low porosity - 1.85 mm thick - 25 mm x 25 mm (for aortic graft anastamotic line augmentation).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE Felt with low porosity -1.85 mm thick - 100 mmx 100 mm (for aortic graft anastamotic line augmentation).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
PTFE Felt with low porosity -1.85 mm thick - 150mm x150 mm (for aortic graft anastamotic line augmentation).The brochure containing the necessary details on the dimensions and the material of the fabric has to be submitted. The specification for thickness has to be adhered whereas the length or width can exceed the specified.
Tissue engineered pericardial patch 4 cm x 4 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic, flexible & ultrathin (2 to 5mm thick) with good suturability with at least 1 year shelf life.
Tissue engineered pericardial patch 6 cm x 6 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic, flexible & ultrathin (2 to 5mm thick) with good suturability with at least 1 year shelf life.
Tissue engineered pericardial patch 8 cm x 8 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic, flexible & ultrathin (2 to 5mm thick) with good suturability with at least 1 year shelf life.
Tissue engineered pericardial patch 10cm x 10 cm with intact extracellular matrix devoid of bovine cells -treated with anticalcification technology without Gluteraldehyde treatment - non-cytotoxic ,non-antigenic, nonthrombogenic, flexible & ultrathin (2 to 5mm thick) with good suturability with at least 1 year shelf life.
Bovine pericardium - 4 cm x 4 cm
Bovine pericardium - 6 cm x 8 cm
Bovine pericardium - 8 cm x 14 cm
PTFE pledgets 0.5mm x 3 mm x 3 mm - SPR
PTFE pledgets 1 mm x 3 mm x 3 mm - SPR
PTFE pledgets 1 mm x 3 mm x 6 mm - SPR
PTFE pledgets 1.5mm x 3 mm x 3 mm - SPR
PTFE pledgets 1.5 mm x 3 mm x 6 mm - SPR
PTFE FELT pledgets -1.65 mm x 4.8mm x 6 mm SPR
PTFE FELT pledgets -1.65 mm x 6mm x 6 mm SPR
Topical hemostatic : Fibrinogen- human thrombin- aprotinin - in prefilled syringes applicator with a total volume of 10 ml in a pack. SPR
Topical hemostatic : Polythylene glycol - 4 ml for raw surfaces of lung for hemostatic and also for preventing air leak and also preventive usage in cardiac / vascular suture lines
Topical hemostatic - Albumin gluter-aldehyde glue -Total volume of 10ml per pack contained in the prefilled syringes and forming a strong but flexible layer of seal- compatible to fix the separated layers of dissected aorta. To be provided with suitable applicator for focused local application.
Topical bio-absorbable hemostatic: Non-oxidative cellulose 5 x 5 cm - hemostatic acting by non--oxidative chemical reaction using cellulose as a substance.
Topical hemostatic comprising of agar and bovine factor proteins Iia, VIIa, Ixa & Xa - 5000 i.u in a pack (Clealy mention the quanity/dose in a pack quoted)
Rib fixing plates of titanium alloy with 2 pairs of screws (Brochure containing the length of the plate, no. of holes and the screws per pack to be mentioned in detail along with the composition material of the plate and screws). Quote an uniform price for the maximum length of the plate available menioning the length. The quoted price should include the cost o 2 pairs of screws. Order will be placed as and when requied.
Carotid shunt of Pruitt-Inahara Dual balloon type with depth markings
Triple lumen central venous catheter with antimicrobial coatings (Biguanide / Chorhexidine with siver sulfadiazene) on both outersurface and the luminals surface with effect lasting for more than 40 days. Quote a uniform price for all sizes. The size will be mentioned at the time of purchase.
Tracheal stents (fully covered) - Straight Stainless Steel type. Should have radio-opaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition. Quote uniform price for all the sizes.
Tracheal stents (fully covered) - Straight Nitinol type. Should have radio-opaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition. Quote uniform price for all the sizes.
Tracheal stents (fully covered) - Straight Silicone type. Should have radio-opaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition. Quote uniform price for all the sizes.
Tracheal stents (fully covered). Bifurcated (Y) Stainless Steel type. Should have radio-opaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition. Quote uniform price for all the sizes.
Tracheal stents (fully covered) - Bifurcated (Y) Nitinol type. Should have radio-opaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition. Quote uniform price for all the sizes.
Tracheal stents (fully covered) - Bifurcated Silicone type. Should have radio-opaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition. Quote uniform price for all the sizes.
Bronchial stents (fully covered) - Staight Should have radio-opaque markers at both the ends. The purchase will be done as when needed on SOS basis (Consignment mode) in which case, a set of various sizes of stents to be brought on the day of procedure and after the usage the rest of the stents can be taken back. The various available sizes and length may be mentioned while quoting. The most commonly used two sizes will be purchased at first as an emergency stock and the rest of the purchase will be by consignment mode. Size ordered will be based on the patient's condition
Aortic stent grafts - Straight type : To be supplied with the suitable delivery system with smallest possible catheter outer diameter. The stent should be MRI compatible. The purchase will be done as when needed (S.O.S), in which case, a set of various sizes of stents to be brought on the day of surgery and after the usage the rest of the stents can be taken back - i.e consignment mode. The various available sizes and length may be mentioned while quoting. (Size ordered will be based on the patient's condition)
Aortic stent grafts - Bifurcated Y type for abdominal aorta : To be supplied with the suitable delivery system with smallest possible catheter outer diameter. The stent should be MRI compatible. The purchase will be done as when needed (S.O.S), in which case, a set of various sizes of stents to be brought on the day of surgery and after the usage the rest of the stents can be taken back - i.e consignment mode. The various available sizes and length may be mentioned while quoting. (Size ordered will be based on the patient's condition)
CABG drape kit with 9 components: (Totally 16 parts in a pack) - made up of high quality specialized single sheeted fabric with the property of being fluid absorbent on the outerside and fluid- impervious on the innerside: Components: i) Bottom sheet - (180 x 200) cm with 'W' configuration at proximal end with adhesive margins to give a complete encircling cover for the genital and groin fold areas and also for the back of the lower limbs ii) A pair of leggings - universal fit & short length upto ankle with a tie (or) a pair of small triangular sheets -(90 x90 x125)cm with adhesive tapes iii) Side sheets (4 no’s) -(90 x 100)cm with one adhesive margin iv) A lower segment sheet (180x180) cm with one adhesive margin v) A Head-side drape sheet (150x250) cm with one adhesive margin vi) A large trolley sheet (180 x 240) cm vii) A small trolley sheet (150 x 200) cm viii) Cautery Bags (4 no’s) - (30 x 30)cm ix) Preferably with a defibrillator paddle bag - 25 cm wide x 30 cm long with all four side adhesive margins. https://docs.google.com/document/d/1yOTEiRccpX3apBvgbX438OyfICTzx77sPLQ3Xk4ZapA/edit
General open heart drape kit containing the following components. (Totally 10+1 parts in a pack) made up of high quality specialized single sheeted fabric with the property of being fluid absorbent on the outer side and fluid- impervious on the innerside. Each component has to be labelled for identification on its outermost side of the folded pack. Components: i) Side sheets (4 no’s) -(90 x 100)cm with one adhesive margin ii) A lower segment sheet (180x180) cm with one adhesive margin iii) A Head-side drape sheet (150x250) cm with one adhesive margin vi) A large trolley sheet (180 x 240) cm vii) A small trolley sheet (150 x 200) cm viii) Cautery Bags (2 no’s) - (30 x 30)cm ix) Preferably with a defibrillator paddle bag - 25 cm wide x 30 cm long with all four side adhesive margins https://docs.google.com/document/d/1_H3eESdoj0TiCagChls5BVnMXGQfF3lW9PTyPavhcKE/edit?usp=sharing
Sternal Wound Dressing Pad - Sterile adhesive polyurethane film with absorbent pad, 20 x 10 cm - SPR
Sterile cotton gauze - Small size: 5cm x 5cm- 16 ply type 17 with radio-opaque line marker. The marker should be made up of multi-filament yarn with at least 60% barium coated which will not break or comeout separately during usage. Each should have folded edges to avoid fraying of the fabric & bleached with hydrogen peroxide. Each should be wrapped in ETO sterilized double sealed blister pack along with sterility indicator. Mention the number of gauzes in a single pack if the cost is quoted for a pack. Iif not mentioned, the quoted proce will be assumed as that of individual piece. SPR.
Sterile cotton gauze-Medium size: 7.5cm x7.5cm- 16 ply type 17 with radio-opaque line marker. The marker should be made up of multi-filament yarn with at least 60% barium coated which will not break or comeout separately during usage. Each should have folded edges to avoid fraying of the fabric & bleached with hydrogen peroxide. Each should be wrapped in ETO sterilized double sealed blister pack along with sterility indicator. Mention the number of gauzes in a single pack if the cost is quoted for a pack. Iif not mentioned, the quoted proce will be assumed as that of individual piece. SPR.
Sterile cotton gauze- Large size: 10cm x10cm- 16 ply type 17 with radio-opaque line marker. The marker should be made up of multi-filament yarn with at least 60% barium coated which will not break or comeout separately during usage. Each should have folded edges to avoid fraying of the fabric & bleached with hydrogen peroxide. Each should be wrapped in ETO sterilized double sealed blister pack along with sterility indicator. Mention the number of gauzes in a single pack if the cost is quoted for a pack. Iif not mentioned, the quoted proce will be assumed as that of individual piece. SPR.
Sterile Surgical mopping pad with radio-opaque line marker & a Coloured loop 30 x 30 cm. (Type 17 - 8 ply). The marker should be made up of multifilament yarn with at least 60% barium coated which will not break or comeout separately during usage. Each should have folded and stitched edges to avoid fraying of the fabric. The material should have been bleached using hydrogen peroxide. Each pack should have ETO sterilized with double sealed blister pack for secured sterility with sterility indicator. There should be a colored loop for identification. Mention the number of pads in a single pack if the cost is quoted for a pack. SPR.
Sterile, absorbent, chitosan gelling fibre dressing for pressure ulcers - 10 x 10 cm
Montogomery T-type Silicone tracheostomy tube - Brochure containing all the dimensons of the tube to be provided. Oder will be placed when required
Double lumen endotracheal tube (DLET) - Left sided- 26F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) - Left sided- 28F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) - Left sided- 32F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) - Left sided- 35F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) - Left sided- 37F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) - Left sided- 39F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) - Left sided- 41F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) -Right sided- 26F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) -Right sided- 28F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) -Right sided- 32F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) -Right sided- 35F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) -Right sided- 37F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) -Right sided- 39F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Double lumen endotracheal tube (DLET) -Right sided- 41F Transparent double lumen cuffed endobronchial tube with smooth gliding surface radioopaque line & pilot balloons with separate color coding for bronchial & tracheal lumens and balloons.
Endo-bronchial blockers - with balloon -Ardnt type -For one lung ventilation - Wire loop guide and suitable adapter for bronchoscope.
Endo-bronchial blockers -with balloon -Cohen type - For one lung ventilation with flexible defelcting tip with suitable adapter to faciltate bronchoscope.
Endo-bronchial blockers - with balloons - EZ type - with Y-tipped For one lung ventilation
Ultrasonic Nebulizer - catalogue brochure with figure to be submitted.
Soft vinyl percussors for performing chest physiotherapy in different sizes. The size can be mentioned.
Electro Surgical (cautery) pencils - (electrosurgical electrode) with Long arm - Spatula tip & hand control of twin switch type for cutting and coagulation modes- Should be Compatible with Martin & Alan Cautery (electrosurgical) machines. Prefererable dimensions: shaft diameter less than 2.5 mm. Shaft length -13 to 15cm. Cable length - atleast 3m. Appropraite certification for electrical safety should be confirmed. - SPR
Electro Surgical (cautery) pencils - (electrosurgical electrode) with Short arm - Spatula tip & hand control of twin switch type for cutting and coagulation modes- Should be Compatible with Martin & Alan Cautery (electrosurgical) machines. Prefererable dimensions: shaft diameter less than 2.5 mm. Shaft length -7 to 8cm. Cable length : atleast 3m. Appropraite certification for electrical safety should be confirmed. - SPR
Disposbale Electro Surgical Diatheramy Plates compatible with Alan and Martin (Adult / Pead.)
Disposable ophthalimic lancetip blades with handle of at least 4 inches length for coronary arteriotomy - SPR
Sterile cover for Echocardio-graphic probe For use in the operative -field. Should fit universally all utrasound probes commonly used during cardiac surgery with special fold to accomdate the probe end without wrinkles. Should be made up of clear transparent latex free medical grade material - polythene. Length of cover - 150 cm; Width of the cover - 10 cm. The kit should also contain securing tapes to hold the cover around the probe and preferably with ultrasound transmission gel - pack.
Nasal interface for oxygen delivery thropugh soft and contoured nasal prongs compatible with the - Airvo-optiflow MR 850 systmof Fischer & Paykel; Should be supplied with a three-way connector fitting all the F&P circuits, Airvo™ and F&P 850 systems; also an adjustable head strap providing a secure, soft fit along with soft cheek pads designed to add stability and reduce pressure on the face; a head strap clip also to be provided.
Tracheal interface for oxygen delivery thropugh soft and contoured nasal prongs compatible with the - Airvo-optiflow MR 850 systmof Fischer & Paykel; Should be supplied with a three-way connector fitting all the F&P circuits, Airvo™ and F&P 850 systems; also an adjustable head strap providing a secure, soft fit along with soft cheek pads designed to add stability and reduce pressure on the face; a head strap clip also to be provided.
Asepto Syringe of about 50-60 ml with transparaent pumping bulb.
FLOW THROU HOUSING - Closed injectate delivery system to measurement of cardiac output and essential Swan-Ganz thermodilution pulmonary artery catheters
NON-CONSUMABLES (STAINLESS STEEL)
De bakey Straight Fine Vascular Forceps - Short (18cm) Jaw (1.5 x 14mm) 5mm wide shaft
De bakey Straight Fine Vascular Forceps - Medium (25cm) Jaw (1.5 x 14mm) 5mm wide shaft
De bakey Straight Fine Vascular Forceps - Long (30cm) Jaw (1.5 x 14mm) 5mm wide shaft
De bakey Angled 45º Fine Vascular Fine Forceps - Short (18cm) with Smooth jaw (1.5 x 14 mm) & 5mm wide shaft - for IMA dissection
De bakey Angled 45º Fine Vascular Forceps - Medium (25 cm ) with Smooth jaw (1.5 x 14 mm) & 5mm wide shaft - for IMA dissection
De bakey Angled 45º Fine Forceps Vascular - Long (30 cm) with smooth jaw (1.5 x 14 mm) & 5mm wide shaft - for IMA dissection
I.M.A. Fine Micro-forceps - Straight - 0.35mm tips, Fine-Micro 0.07mm 1x2 teeth withTungsten Carbide coated tying platform, Round Handle - 20 to 22 cm
I.M.A. Micro-forceps - Straight - 0.5mm tips, Micro 0.25mm 1x2 teeth withTungsten Carbide coated tying platform, Round Handle with counter balance - 20 to 22 cm
I.M.A. Ring tip Forceps - Straight 1mm TC coated rings, Round Handle with Counter balance- 20-22 cm
Gerald micro-forceps - Short (15-17 mm) - with Straight tips
Gerald micro-forceps - Long (21-23 mm) - with Straight tips
Debakey Tissue Forceps - 3 to 3.5 mm wide tip - Long - 18-23 cm
Debakey Tissue Forceps - 2 to 2.5 mm wide tip - Long - 18-23 cm
Debakey Tissue Forceps - 1 to 1.5 mm wide tip - Long - 18-23 cm
Halsted Mosquito Hemostatic Forceps - Short Straight -10 to 13 cm
Halsted Mosquito Hemostatic Forceps - Short Curved -10 to 13 cm
Halsted Mosquito Hemostatic Forceps - Long Straight -15 -18 cm
Halsted Mosquito Hemostatic Forceps - Long Curved-15-18 cm
Spencer-Wells hemostatic forceps - Straight & serrated jaws, with ring handle & ratchets - 18-20 cm
Spencer-Wells hemostatic forceps - Curved & serrated jaws, with ring handle & ratchets - 18-20 cm
Heiss hemostatic forceps - Straight & serrated jaws, with ring handle & ratchets - 20-23 cm
Heiss hemostatic forceps - Curved & serrated jaws, with ring handle & ratchets - 20-23 cm
Heiss hemostatic forceps - Deeply Curved & serrated jaws, with ring handle & ratchets - 20-23 cm
Robert hemostatic forceps - Straight & serrated jaws with blunt tip , with ring handle & ratchets - 22-25 cm
Robert hemostatic forceps - Curved & serrated jaws with blunt tip , with ring handle & ratchets - 22-25 cm
Kelly Artery Forceps - Straight & serrated jaws, with ring handle, with ratchets 14 -16 cm
Kelly Artery Forceps - Curved & serrated jaws, with ring handle, with ratchets 14 -16 cm
Mixter Right-angled Dissection forceps - Long - 18-20 cm long.
Mixter Right-angled Dissection forceps -Short 13-15 cm long.
Towel clip -Backhaus type - Short (10-13 cm) with Curved Sharp jaws, Ring Handle with Ratchet.
Towel clip -Backhaus type - Long (10-13 cm) with Curved Sharp jaws, Ring Handle with Ratchet.
Towel Clip - Schaedel type - 8-10 cm
Morse Towel Clip Tubing Holders to hold 1/4 inch tubing- 13-16 cm with sharp ends and ring handles with ratchet
Morse Towel Clip Tubing Holders to hold 3/8 inch tubing- 13-16 cm with sharp ends and ring handles with ratchet
Morse Towel Clip Tubing Holders to hold 1/2 inch tubing- 13-16 cm with sharp ends and ring handles with ratchet
Jacobson needle holder - 16-18 cm with Tungsten Carbide Coated straight jaws & spring style round handle with lock for holding 5-0 & 6-0 sutures
Jacobson needle holder - Delicate - 16-18 cm with Tungsten Carbide Coated straight jaws & spring style round handle with lock for holding 7-0 & 8-0 sutures
Castroviejo Micro-needle holder - 14-16 cm with Tungsten Carbide inserts straight jaws & spring style flat handle with lock for holding 6-0 & 7-0 suturessutures
Castroviejo Heavy needle holder - 14-16 cm with Tungsten Carbide inserts straight jaws & spring style flat handle with lock for holding 6-0 & 7-0 suturessutures
Ryder Needle Holder - Short (15-17 cm) - with Tungsten carbide inserts & Straight jaws
Ryder Needle Holder - Long (21-23 cm) - with Tungsten carbide inserts & Straight jaws
DeBakey Needle Holder - Short (15-17 cm) - with Tungsten carbide inserts & Straight jaws
DeBakey Needle Holder - Long (21-23 cm) - with Tungsten carbide inserts & Straight jaws
Metzenbaum Scissors - Straight - Razor edge Blades with Tenotomy tips, Ring Handle, 14-16 cm
Metzenbaum Scissors - Curved - Razor edge Blades with Tenotomy tips, Ring Handle, 14-16 cm
Potts Micro-scissors - 25 -30° Angled short - 11-15cm - with sharp fine blades, spring style flat handle.
Potts Micro-scissors - 45° Angled short - 11-12cm - with sharp fine blades, spring style flat handle.
Potts Micro-scissors - 60° Angled short - 11-12cm - with sharp fine blades, spring style flat handle.
Favolaro - Micro-scissors - 125° Angled short - 11-12cm - with sharp fine blades, spring style flat handle.
Potts Micro-scissors - 25 -30° Angled - Long - 16-18 cm - with sharp fine blades, spring style flat handle.
Potts Micro-scissors - 45° Angled - Long - 16-18 cm - - with sharp fine blades, spring style flat handle.
Potts Micro-scissors - 60° Angled - Long - 16-18 cm - - with sharp fine blades, spring style flat handle.
Favaloro Micro-scissors - 125° Angled short - Long - 16-18 cm -- with sharp fine blades, spring style flat handle.
Iris-Eye Scissors - Straight - Razor edge Blades with blunt tips, Ring Handle, 10-12 cm
Iris-Eye Scissors - Curved - Razor edge Blades with blunt tips, Ring Handle, 10-12 cm
Mayo scissors - Straight round - standard - 17-20 cm
Mayo scissors - Curved round - standard - 19-23 cm
Mayo-Harrington scissors - straight - 30-32 cm
Wire Cutter - double action -Tungsten carbide edge 17-20 cm
Rib shears (Gluck type)- 18-20 cm
Rib shears (Bethune) - 32-36 cm
Nerve or Vessel Hook- Fine tip Total length : 32-37 cm with working length -23 cm Tip size : 1 x 6 mm
Nerve or Vessel Hook Standard tip Total length : 32-37 cm with working length -23 cm Jaw Size: 2 x 10 mm
Nerve or Vessel Hook - 90º with fine tip. Total length : 32-37 cm with working length -24-28 cm Jaw length : 4-7 mm
Cooley Left Atrial Retractor-Large (blade size :4-5 cm x 4-5 cm) 22-24 cm long
Cooley Left Atrial Retractor-small (blade size :2 cm x 4-5 cm) 22-24 cm long
Cooley Right Atrial Retractor-Large (blade size :4-5 cm x 4-5 cm) 22-24 cm long
CooleyRight Atrial Retractor-small (blade size :2 cm x 4-5 cm) 22-24 cm long
Yankauer Suction tip - 28-35 cm
Intracardiac suction - 135 º angled detacheable tip - angled shaft - 26-30cm long
Vorse Tubing Occluding Clamp -Large 8 inch (20 cm) with safety guard and serrated jaws for occluding 1/2 inch /3/4 inch tubings.
Vorse Tubing Occluding Clamp - Small 6 inch (15 cm) with safety guard and serrated jaws for occluding 1/4 inch 1/16 inch tubings.
Satinsky Vascular occluding clamp with 2-3 mm wide jaws with cross serrated surface - 25-28 cm
Cooley Satinsky Vascular occluding clamp with 2-3 mm wide jaws with cross serrated surface - 22-24 cm
Morris Ascending Aortic Cross Clamp - 18-22 cm
DeBakey Aortic Clamp - Angled & Curved 7cm jaws with Curved Shanks - 25-28cm long
Tuffier Sternal / Rib Retractor - with a spread of 15-18 cm Arm length - 11-13 cm Blades - 4-6 cm deep x 4-6 cm wde.
Finochietto Sternal / Rib Retractor - Large - with curved arm & a spread of 21-25 cm. Arm length - 26-30 cm; Blades- 6-8 cm deep x 6-8 cm wide;
Finochietto Sternal / Rib Retractor - Medium - with curved arm & a spread of 14-17 cm. Arm length - 24-27 cm; Blades- 4-6 cm deep x 4-6 cm wide;
Finochietto Sternal / Rib Retractor - Small - with curved arm & a spread of 5-10 cm. Arm length - 6-12 cm; Blades- 1-3 cm deep x 1-3 cm wide;
Cooley Sternal Retractor - Large- with a spread of 19-23 cm Arm length - 16-18cm Blades - 2.5 to 3.5 cm x 10-11 cm.
Cooley Sternal Retractor - Medium -with a spread of 16-17 cm Arm length - 15-16 cm Blades - 2.5 to 3.5 cm x 5 -6 cm.
Cooley Sternal Retractor - Small - with a spread of 10-13 cm Arm length - 7-12 cm Blades - 2 to 3 cm x 1-4cm.
Cooley Sternal Retractor -Tiny - with a spread of 7-8 cm Arm length - 5-6 cm Blades - 1-2 cm x1-2 cm.
Castaneda Sternal Retractor- Pedaitric type - spread of 11-12 cm Arm length - 12-13 cm Blades - 1-2 cm x 5-6 cm.
Castaneda Sternal Retractor- Neonatal type - spread of 6-7 cm Arm length - 5-6 cm Blades - 1-1.5 cm x 3-4 cm.
Morse- Favaloro-Sternal / Rib Retractor -Large- with a spread of 19-21 cm Arm length - 20 cm Blades - 2 to 3 cm x 2 -3 cm.
Morse- Favaloro-Sternal / Rib Retractor- Medium - with a spread of 16-17 cm. Arm length - 15-16 cm. Blades-1.5-2 cm x 1.5-2cm
Morse- Favaloro-Sternal / Rib Retractor - Small with a spread of 13-15 cm. Arm length -7-12 cm Blades-1-2 cm x 1-2 cm.
Burford - Finochietto - Rib Retractor - Large -with a spread of 25-28 cm. with detacheable set of small and large blades. Arm length - 18-21 cm; Large blade- 6-8 cm deep x 6-8cm wide; Small blades - 4-7cm deep x 4-7 cm wide;
Burford - Finochietto - Rib Retractor - Medium - with a spread of 19-20 cm. with detacheable set of small and large blades . Arm length - 17-20 cm; Large blade- 6-7 cm deep x 6-7cm wide; Small blades - 4-6cm deep x 4-6 cm wide;
Czerny Double-ended Retractor- 18-20 cm with two prongs at one and a solid blade (2-4 cm x 2-4 cm) at the other end.
Langenbeck Retractor- Large blade (3-4 cm x 5-7 cm) overall 20-24 cm
Langenbeck Retractor- Medium blade (2 cm x 4-6 cm) overall 19-21 cm
Langenbeck Retractor- Small blade (1 cm x 3 cm) - Overall 18-20 cm
Mini- Langenbeck Retractor- blade (0.5 -0.6 cm x 0.8 -1.8 cm) - Overall 18-20 cm long
Desmarres Eyelid Retractor - 8 mm wide blade - 13-15 cm long
Desmarres Eyelid Retractor - 10 mm wide blade - 13-15 cm long
Desmarres Eyelid Retractor - 12 mm wide blade - 13-15 cm long
Desmarres Eyelid Retractor - 14 mm wide blade - 13-15 cm long
Desmarres Eyelid Retractor - 16 mm wide blade - 13-15 cm long
Desmarres Eyelid Retractor - 18 mm wide blade - 13-15 cm long
Desmarres Eyelid Retractor - 20 mm wide blade - 13-15 cm long
Desmarres Eyelid Retractor - 8 mm wide blade - 16-18 cm long
Desmarres Eyelid Retractor - 10 mm wide blade 16-18 cm long
Desmarres Eyelid Retractor - 12 mm wide blade 16-18 cm long
Desmarres Eyelid Retractor - 14 mm wide blade - 16-18 cm long
Desmarres Eyelid Retractor - 16 mm wide blade - 16-18 cm long
Desmarres Eyelid Retractor - 18 mm wide blade - 16-18 cm long
Desmarres Eyelid Retractor - 20 mm wide blade - 16-18 cm long
VINAYAK ENTERPRISES
TTK HEALTHCARE LIMITED
Lub Dub Medical Technologies Pvt Ltd
HEART CARE INDIA CO
BIO IMPLANTS INDIA (P) LIMITED
S.M.MEDICARE
SHRI MANICKAM ENTERPRISES
Phoenix Medicos
SV SURGITECH PRIVATE LIMITED
KALKI MEDICAL ENTERPRISES
CITRIC HEALTH CARE PRIVATE LIMITED
MLSS Implant Medicare Pvt Ltd
BHN SURGICALS PVT LTD
SHUBHAN ENTERPRISES
INTEGRATED MEDICAL SYSTEMS
HEBBAR SURGICAL INSTRUMENTS
Medifocus India Pvt Ltd
BREATHE HEALTH CARE
Parasakthi Agencies
Vaishnavisurgicals
Hubra Pharmaceuticals Pvt Ltd
B L Lifesciences Pvt. Ltd
STAR EQUIPMENTS AND SURGICALS
VIVE SOLUTIONS
Chennai Medicco Surgicals
QualMed
stage.html
html • 0.10 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .