Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹4.0 L
Closing Date
11 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
GENERAL
24 conditions · 5 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a) Attested Certificates(s) issued by Executive or Nominated Authority of the government Departments or Semi-Government/Public Sector Undertakings for the value of the work done for them during the qualifying period including current financial year certifying the bill amounts paid Agreement-wise and Date-wise or attested photo copy of such certificate. Such certificates will be accepted only from Govt. / Govt. bodies / PSUs authorities. Certificates issued by Private Bodies will not be considered.
NOTE: (i) Financial Year shall normally, be reckoned as 1st April to 31st March of the Next Year. However, for Turnover Criteria, the Financial Year as applicable to the Company /Tenderer is to be considered, if it defers from the above. (ii) Current Financial year is reckoned as the incomplete Financial year in which the date of tender submission falls. (iii) Chartered Accountant statements duly indicating yearly receipts will not be considered until and unless backed by Audited Balance Sheets or Provisional Balance sheet. (iv) (v) If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
If JV firms are allowed to participate; Financial eligibility of the JV Firm shall be adjudged based on satisfactory fulfillment of the Para No.17.15.2 of J.V guide lines of IRSGCC April - 2022 [with up to date correction slip].
Definition of similar work: Any Civil Engineering work involving Building work /Concrete work. Tenderer should have valid electrical contractor's license in his/their name or he should give an undertaking that he will engage capable agencies for electrical work who has the valid electrical contractor's license in his/their name.
78 conditions · 29 needing a document upload
Uploading of Proforma -18 attached with Tender document (Certificate signed by Tenderer and Chartered Accountant), w he n balance sheet for the first previous year is yet to be prepared/ audited.
Proforma-16 for self-certificate in regard to meeting the Minimum Local Content requirements as per Make in India Policy for Procurement order value less than of Rs. 10 Crores. OR Proforma-17 for Certificate from the statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content as per Make in India Policy for Procurement Order Value more than Rs.10 Crores. Provisions of Make in India Policy 2017 (revised during 2024 vide Department for Promotion of Industry and Trade, Ministry of Commerce and Industry's letter No. P-45021/2/2017-PP (BE-II)-Part(4)Vol.II dated 19.07.2024) issued by Govt. of India, as amended from time to time, shall be followed for consideration of tenders.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
(i) The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. (ii) documents shall be submitted according to clause 14 of IRGCC 2022:
This tender complies with PUBLIC PROCUREMENT POLICY ORDER-2017 dated 15.06.2017. Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions. Provisions of Make in India Policy 2017 issued by Govt. of India, as amended from time to time, shall be followed for consideration of tenders.
The General Conditions of Contract governing the performance of the works covered by this tender are the Indian Railway Standard General Conditions of Contract [IRSGCC] as amended from time to time up to date. A soft copy of the Indian Railway Standard General conditions of Contract is uploaded in the attached documents to the tender for reference. Hard copy of IRSGCC (with up-to-date correction slip) may be perused in the office of the Principal Chief Engineer Officer/ South Western Railway / Hubballi - 580020. The tenderer/s is/are deemed to have kept himself/themselves fully Informed of the provisions of the IRS General conditions of Contract including all corrections and Amendments issued up to date while submission of offer and any claim that he/they is/are not aware of any amendment or correction slip to the IRSGCC shall not be entertained.
STUDY OF DRAWINGS AND LOCAL CONDITIONS: The drawings for the works can be seen in the office of the General Manager/Divisional Railway Manager. It should be noted that these drawings are meant for general guidance only and Railway may suitably modify them during the execution of work according to the circumstances without making the Railways liable for any claims on account of such changes. If there is any variation between the description in the tender and the detailed plans, the Engineer-in-Charge will operate the correct description and his decision is final and binding on the tenderer/ Contractor. The Tenderer/Contractor is required to inspect the sites of works and acquaint himself with the site conditions, availability of approaches for transporting of men and materials, space and other factors relating to the works, availability of labour, electricity and water, etc., before quoting his rates. The extent of lead and lift involved in the execution of works and any difficulties involved in the execution of work should also be examined before formulating the rates for complete items of works described in the schedule. The Tender submitted will be deemed to have been made after such inspection.
DRAWINGS FOR WORKS: The percentage rates for the schedule items and itemized rates for the non-scheduled items quoted by the tenderer as may be accepted by the railways will, hold good irrespective of any changes, modifications, alterations, additions, omissions in the locations of structures and detailed drawings, specifications and/or the manner of executing the work. It should be specifically noted that some of the detailed drawings may not have been finalized by the Railway and will, therefore, be supplied to the contractor as and when they are finalized on demand. No compensation whatsoever on this account shall be payable by the Railway Administration. No claim whatsoever will be entertained by the Railway on account of any delay or hold up of the works arising out of delay in approval of drawings, changes, modifications, alterations, additions, omission and the site layout plans or detailed drawings and design and/or late supply of such material as are required to be arranged by the Railway or due to any other factor on Railway Accounts.
Manual tenders, supporting documents etc., sent by Post/FAX/Courier or in Person SHALL NOT BE ACCEPTED.
All requisite documents are to be properly submitted online only and the bidders should ensure that the content of the documents uploaded is distinctly legible /readable.
CORRIGENDUM NOTICE ON IREPS: Railway may modify the tender document by issuing online corrigendum through "www.ireps.gov.in" 15 days prior to the tender closing date. For the purpose of CORRIGENDUM in the tender, NIT period is splitted as under: (a) ADVERTISEMENT PERIOD: The time during which all information pertaining to tender shall be available but offers cannot be submitted (b) OFFER SUBMISSION PERIOD: 15 days prior to closing of tender, during which tenderers can submit their offer.
If the Bid of a Tenderer is seriously unbalanced in relation to the Engineer's estimate of the cost of work to be performed under the contract, the Railways may require the tenderer to produce detailed price analysis for any or all items of the Tender Schedule, to demonstrate the internal consistency of those prices with the construction methods and schedule proposed.
No Technical and Financial credentials are required for tenders having value up to Rs 50 lakh. For tenders valuing more than Rs. 50.00 lakh: The offer of Tenderer(s) who do not enclose Experience Certificate & Turnover Certificate with requisite details, and supporting documents along with their Tender to establish their credentials shall be summarily rejected, even though they are working contractors or contractors on approved list.
The offer shall be evaluated only from the certificates/documents submitted along with the tender offer.
Any Certificate /Documents offered / submitted /received after the tender opening shall not be given any credit and shall not be considered.
Attestation of documents may be self attested or attested by a Gazetted Officer.
Railwayreservestherighttoverifythe authenticityofthe documents/information furnished.
IRSGCC para 6.0 of part-I (a)(ii) Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt.& as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates. (a)(iii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/ UTGST /SGST Act to railway immediately after the award of contract, without which no payment shall be released to the Contractor. The Contractor shall be responsible for deposition of applicable GST to the concerned authority. (a)(iv) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority. (b) When work is tendered for by a firm or company, the tender shall be signed by the individual legally authorized to enter into commitments on their behalf. (c) The Railway will not be bound by any power of attorney granted by the tenderer or by changes in the composition of the firm made subsequent to the execution of the contract. It may, however, recognize such power of attorney and changes after obtaining proper legal advice, the cost of which will be chargeable to the Contractor.
Increase/decrease of TAXES: if rates of existing GST or cess on GST for Works Contract is increased or any new tax /cess on Works Contract is imposed by Statute after the date of opening of tender but within the original date of completion/date of completion extended under clause 17 & 17A and the Contractor thereupon properly pays such taxes/cess, the Contractor shall be reimbursed the amount so paid. Further, if rates of existing GST or cess on GST for Works Contract is decreased or any tax/cess on Works Contract is decreased / removed by Statute after the date of opening of tender, the reduction in tax amount shall be recovered from Contractor's bills/Security Deposit or any other dues of Contractor with the Government of India.
Fixed Deposit Receipts (FDRs) submitted after award of tender towards Security Deposit/Performance Guarantee should be with automatic renewal facility only.
CONSORTIUM AGREEMENTS AND MOUS SHALL NOT BE CONSIDERED FOR PARTICIPATING IN THIS TENDER.
Tenderer(s) shall note that conditional/alternate offer will not be considered and will summarily be rejected, even though such condition makes them as the lowest tenderer.
Shramik kalyan While processing payment of any 'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramik kalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till ____Month, ____Year.
Date of inviting tender shall be the date of publishing tender notice on IREPS website if tender is published on website or the date of publication in newspaper in case tender is not published on website.
ADEN/Bangarpet Sub-Division: Proposed Construction of new S and T building including electrical portion at Bisanatham (BSM) station. Maintenance period is 3 years. Composite Tender.
08SBC26OF16-04-26ITEM-05
08SBC26OF16-04-26ITEM-05
Open
Works - General
12 Months
Dharwad, Karnataka
₹0
₹4.0 L
11 May 2026
17 Apr 2026
27 Apr 2026
167 items across 4 schedules · ₹18,32,776.21 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | All kinds of soil | cum | 200 | 205.45 | 41,090 |
| 2 | Ordinary rock | cum | 800 | 412.95 | 3,30,360 |
| 3 | Hard rock (requiring blasting) | cum | 150 | 711.35 | 1,06,702.5 |
| 4 | Hard rock (blasting prohibited) | cum | 150 | 1,184.3 | 1,77,645 |
| 5 | Ordinary or hard rock | cum | 200 | 187.4 | 37,480 |
| 6 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | cum | 130 | 2,161.2 | 2,80,956 |
| 7 | All kinds of soil | Sqm | 500 | 28.15 | 14,075 |
| 8 | 1:1.5:3 (1 Cement: 1.5 coarse sand(zone- III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | cum | 10 | 8,130.65 | 81,306.5 |
| 9 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). | Sqm | 200 | 452.25 | 90,450 |
| 10 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. | Per bag of cement of 50kg | 500 | 57.15 | 28,575 |
| 11 | Concrete of M10 grade with minimum cement content of 220 kg /cum | cum | 60 | 8,033.2 | 4,81,992 |
| 12 | Concrete of M20 grade with minimum cement content of 270 kg /cum | cum | 10 | 8,387.15 | 83,871.5 |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete | Sqm | 250 | 307.95 | 76,987.5 |
| 14 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | Sqm | 200 | 669.55 | 1,33,910 |
| 15 | Suspended floors, roofs, landings, balconies and access platform | Sqm | 550 | 766.55 | 4,21,602.5 |
| 16 | Shelves (Cast in situ) | Sqm | 100 | 766.55 | 76,655 |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers | Sqm | 450 | 608.35 | 2,73,757.5 |
| 18 | Columns, Pillars, Piers, Abutments, Posts and Struts | Sqm | 350 | 804.25 | 2,81,487.5 |
| 19 | Weather shade, Chajjas, corbels etc., including edges | Sqm | 100 | 814.95 | 81,495 |
| 20 | Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) | Sqm | 300 | 319.25 | 95,775 |
| 21 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | cum | 25 | 9,673.5 | 2,41,837.5 |
| 22 | Thermo-Mechanically Treated bars of grade Fe-500D or more. | Kg | 17000 | 89.65 | 15,24,050 |
| 23 | Thermo-Mechanically Treated bars of grade Fe-500D or more. | Kg | 17000 | 89.65 | 15,24,050 |
| 24 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. | Metre | 500 | 64.7 | 32,350 |
| 25 | Concrete of M25 grade with minimum cement content of 330 kg /cum | cum | 150 | 8,683.8 | 13,02,570 |
| 26 | Concrete of M25 grade with minimum cement content of 330 kg /cum | cum | 120 | 10,306.2 | 12,36,744 |
| 27 | Add for using extra cement in the items of design mix over and above the specified cement content therein. | Quintal | 200 | 688.45 | 1,37,690 |
| 28 | Providing and laying Autoclaved Aerated concrete blocks (AAC) masonry 150mm/230mm/300 mm thick AAC with Grade-1 blocks of density 551-650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer- in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). | cum | 250 | 6,994.15 | 17,48,537.5 |
| 29 | Cement mortar 1:6 (1 cement : 6 coarse sand) | cum | 100 | 6,653.45 | 6,65,345 |
| 30 | Cement mortar 1:6 (1 cement : 6 coarse sand) | cum | 50 | 8,275.7 | 4,13,785 |
| 31 | Area of slab upto 0.50 sqm | Sqm | 50 | 4,679.35 | 2,33,967.5 |
| 32 | Granite work | Metre | 100 | 418.85 | 41,885 |
| 33 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 350 | 1,063.45 | 3,72,207.5 |
| 34 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. | Sqm | 195 | 4,474.2 | 8,72,469 |
| 35 | Second class teak wood | cum | 2 | 1,31,576.95 | 2,63,153.9 |
| 36 | 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). | Sqm | 40 | 2,231.2 | 89,248 |
| 37 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading | Sqm | 40 | 1,521.6 | 60,864 |
| 38 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws | Sqm | 50 | 3,086.1 | 1,54,305 |
| 39 | Fixed to steel windows by welding | Kg | 2000 | 181 | 3,62,000 |
| 40 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. | Sqm | 35 | 1,484.7 | 51,964.5 |
| 41 | 300x16 mm | Each | 50 | 180.55 | 9,027.5 |
| 42 | 250x16 mm | Each | 40 | 165.9 | 6,636 |
| 43 | 250x10 mm | Each | 20 | 74.65 | 1,493 |
| 44 | 200x10 mm | Each | 20 | 61.05 | 1,221 |
| 45 | Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete. (copper oxized as per IS: 1378) | Each | 10 | 108.65 | 1,086.5 |
| 46 | 125 mm | Each | 50 | 35.2 | 1,760 |
| 47 | Providing and fixing oxidised M.S. Safety chain with necessary fixtures for doors, (weighting not less than 450 gms) and (copper oxized as per IS: 1378) | Each | 20 | 88.95 | 1,779 |
| 48 | 125x64x1.90 mm | Each | 50 | 95.5 | 4,775 |
| 49 | 100X58X1.90 mm | Each | 50 | 86.15 | 4,307.5 |
| 50 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Each | 10 | 109.6 | 1,096 |
| 51 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Each | 10 | 1,025.65 | 10,256.5 |
| 52 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. | Metre | 50 | 702.6 | 35,130 |
| 53 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. | Sqm | 15 | 3,496.75 | 52,451.25 |
| 54 | Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) | Sqm | 5 | 7,249.9 | 36,249.5 |
| 55 | Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). | Sqm | 55 | 10,030.3 | 5,51,666.5 |
| 56 | Hot finished welded type tubes | Kg | 3500 | 154.9 | 5,42,150 |
| 57 | In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete | Kg | 1500 | 102.25 | 1,53,375 |
| 58 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | Kg | 1900 | 142.3 | 2,70,370 |
| 59 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). | Kg | 150 | 612.25 | 91,837.5 |
| 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. | Sqm | 50 | 935.6 | 46,780 |
| 61 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 50 | 1,107.05 | 55,352.5 |
| 62 | Size of Tile 600x600 mm | Sqm | 100 | 1,416.65 | 1,41,665 |
| 63 | Size of Tile 600 x 1200 mm | Sqm | 400 | 1,612.75 | 6,45,100 |
| 64 | 75 mm diameter | Metre | 50 | 213 | 10,650 |
| 65 | 110 mm diameter | Metre | 200 | 319.75 | 63,950 |
| 66 | 75 mm bend | Each | 10 | 91.8 | 918 |
| 67 | 110 mm bend | Each | 10 | 132 | 1,320 |
| 68 | 75 mm Shoe | Each | 10 | 81.1 | 811 |
| 69 | 110 mm Shoe | Each | 10 | 115.95 | 1,159.5 |
| 70 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) | Sqm | 100 | 1,145.95 | 1,14,595 |
| 71 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer- in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 100 | 671.55 | 67,155 |
| 72 | 1:6 (1 cement: 6 fine sand) | Sqm | 2500 | 282 | 7,05,000 |
| 73 | 1:3 (1 cement : 3 fine sand) | Sqm | 500 | 253.05 | 1,26,525 |
| 74 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. | Sqm | 1800 | 214.3 | 3,85,740 |
| 75 | Flush/ Ruled pointing | Sqm | 100 | 319.35 | 31,935 |
| 76 | New work (two or more coats) over and including water thinnable priming coat with cement primer | Sqm | 2000 | 162.55 | 3,25,100 |
| 77 | Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm | Sqm | 1500 | 158.95 | 2,38,425 |
| 78 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture | Sqm | 100 | 144.9 | 14,490 |
| 79 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture | Sqm | 150 | 140.05 | 21,007.5 |
| 80 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. | Sqm | 700 | 180.5 | 1,26,350 |
| 81 | 63 mm to 45 mm size stone aggregate | cum | 70 | 1,624.5 | 1,13,715 |
| 82 | 53 mm to 22.4 mm size stone aggregate | cum | 70 | 1,837.25 | 1,28,607.5 |
| 83 | Stone screening 11.2 mm nominal size (Type B) | cum | 30 | 2,065.7 | 61,971 |
| 84 | Moorum | cum | 20 | 888.3 | 17,766 |
| 85 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. | Sqm | 150 | 951 | 1,42,650 |
| 86 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). | cum | 140 | 8,277.55 | 11,58,857 |
| 87 | 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. | Sqm | 200 | 1,011.2 | 2,02,240 |
| 88 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Each | 5 | 5,268.85 | 26,344.25 |
| 89 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 5 | 2,275 | 11,375 |
| 90 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. | Each | 8 | 1,500.05 | 12,000.4 |
| 91 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. | Each | 5 | 299.35 | 1,496.75 |
| 92 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia | Each | 5 | 6,119.15 | 30,595.75 |
| 93 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Each | 5 | 1,411.15 | 7,055.75 |
| 94 | Circular shape 450 mm dia | Each | 10 | 1,248.6 | 12,486 |
| 95 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. | Each | 10 | 942.15 | 9,421.5 |
| 96 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. | Each | 10 | 600.35 | 6,003.5 |
| 97 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. | Each | 3 | 13,036.55 | 39,109.65 |
| 98 | 20 mm nominal dia Pipes | Metre | 100 | 513.75 | 51,375 |
| 99 | 20 mm nominal dia Pipes | Metre | 120 | 275.25 | 33,030 |
| 100 | 25 mm nominal dia Pipes | Metre | 150 | 370.65 | 55,597.5 |
| 101 | 40 mm nominal dia Pipes | Metre | 50 | 559.2 | 27,960 |
| 102 | 50 mm nominal dia Pipes | Metre | 500 | 811.85 | 4,05,925 |
| 103 | 15 mm nominal bore | Each | 10 | 303.85 | 3,038.5 |
| 104 | 20 mm nominal bore | Each | 10 | 327.95 | 3,279.5 |
| 105 | 15 mm nominal bore | Each | 15 | 303.85 | 4,557.75 |
| 106 | 25 mm nominal bore | Each | 5 | 532.35 | 2,661.75 |
| 107 | 40 mm nominal bore | Each | 2 | 707.3 | 1,414.6 |
| 108 | 50 mm nominal bore | Each | 10 | 878.25 | 8,782.5 |
| 109 | 25 mm nominal bore | Each | 4 | 399.15 | 1,596.6 |
| 110 | 150 mm diameter | Each | 6 | 190.1 | 1,140.6 |
| 111 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 | Each | 10 | 1,712.15 | 17,121.5 |
| 112 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 | Each | 10 | 10,102.5 | 1,01,025 |
| 113 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Litre | 5000 | 9.7 | 48,500 |
| 114 | 15 mm nominal bore | Each | 20 | 708.4 | 14,168 |
| 115 | 15 mm nominal bore | Each | 10 | 594.75 | 5,947.5 |
| 116 | 15mm nominal bore | Each | 20 | 500.35 | 10,007 |
| 117 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms | Each | 5 | 136.6 | 683 |
| 118 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. | Each | 5 | 96.75 | 483.75 |
| 119 | 300 mm dia. R.C.C. pipe | Metre | 100 | 902.05 | 90,205 |
| 120 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) | cum | 10 | 7,510.75 | 75,107.5 |
| 121 | Cement mortar 1:4 (1cement : 4 coarse sand) | cum | 15 | 13,378.15 | 2,00,672.25 |
| 122 | Cement mortar 1:6 (1 cement : 6 coarse sand) | cum | 50 | 8,086.6 | 4,04,330 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS.pdf
ATTACHMENT
NEFTForm.pdf
ATTACHMENT
IRGCCApril2022.pdf
ATTACHMENT
ACS-6.pdf
ATTACHMENT
ACS-5toGCC2022.pdf
ATTACHMENT
Instructionstobidders.pdf
ATTACHMENT
GCC2022ACS-3_20230426_1141401.pdf Advanced correction slip - 3
ATTACHMENT
Advance Correction Slip No.2
ATTACHMENT
GCCACS11_compressed.pdf
ATTACHMENT
ACS7.pdf
ATTACHMENT
JPOCablecuts.pdf
ATTACHMENT
Standardtenderdoc-6.1.pdf
ATTACHMENT
Proforma-161718.pdf
ATTACHMENT
ACS-9dated.09.01.2025.pdf
ATTACHMENT
acs10.pdf
ATTACHMENT
GCC2022ACS-3_20230426_1141401.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
ATTACHMENT
Order-deptforpromotionofindustryandtrade.pdf
ATTACHMENT
TenderDoc-BSMSTBUILDING2.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .