Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.2 LAccepted-AOC SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹38.3 L+₹9,623 (0.25%)Rejected-Finance 143 ALLAHABADPUR GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273001 | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹44.7 L+₹6.5 L (17.0%)Rejected-Finance | 3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to invalid D.D. uploded |
| Sl No | Description | Qty | Unit | M/s A.K Construction L1 | K R GUPTA AND SONS L3 | Sanjai sales and services L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and Installation, testing and Commissioning of Heavy duty continuous operation Industrial Grade Flame proof HUMIDIFIER CUM DEHUMIDIFIER ( Refrigerant Circuit) made out of 1.2 mm ss sheet welded construction, top openable with SS bolt & mist out put nozzle with 22 gauge GI sheet enclosure duly epoxy painted control with 2 NO double safety level switch for low level , High voltage output /,filter assembly, 03 No cooling fan motorised valve and timer for auto flushing mist outlet fan control pel step down transformer with relay contactor switch with light , indication light for drain valve ,humidity off supply on, low level General Specifications- Series: DEW-POINT,Technology:AERO,Type:Vertical,Internal frame: GI section profile,Panel: Heavy Gauge single skin- SS,Color: Bi-color powder coated mat- Standard model- DPS series, Finish- Mat pre-buffed SS panel- Pharma model- DPG series,Ambient temperature: 5 - 50 C,Back suction-front throw for larger area coverage One touch humidity setting and display Temperature display Inbuilt auto Defrost Inbuilt compressor protection Inbuilt Fuse and MCB protection (The unit is fully mobile, works independently without attendant DPS/ DPG Series- 30-90% user settable digital readout,Controller: Micro-computer based with inbuilt compressor protection and auto cut-OFF and cut-ON for Humidity control ( RH- 50 +-5 %) and Temp display Display-Digital for Humidity,Digital for Temperature,Digital for Sensor OPEN- PP,Digital for Tank OVERFLOW- PP,Indications-Compressor ON/OFF and Auto Defrost- 1hr- settable,SET RH,Tank OVERFLOW,Sensor OPEN. Protection-Control fuse for electronic circuit,MCB 2 pole- SIEMENS,Compressor Auto shutoff O/L for Compressor,Protection: MCB 2 pole SIEMENS or eqv,Supply cable: 3 Mtr.Wheels: S- GI casing with rubber lining or G- SS casing with PU lining. | 3 | Each | 8,85,000 ₹26,55,000 Lowest | 9,30,000 ₹27,90,000 | 9,49,500 ₹28,48,500 |
| 1.10Miscellaneous (refrigerant circuit)-Drain tray: Fixed inside below coil.Drain: C- with hose pipe 1 ft length or E- Tank with Auto Overflow Protection arrangement, Compressor: Low power Emerson, Highly, GMCC make hermetically sealed- model dependent,Refrigerant Eco-friendly gas R 407 C,Technology: Standard rugged efficient Low Power,Blower- Almonard,Drain for hose pipe connection: 1/2th Inch,Noise level ~ 50-60 dB- model dependent,Condenser and Evaporator: Aluminum fins on copper tubes, Super-efficient Reciprocating cmpr design Electronic power saving control Auto defrost every 1 hr Ultra High pressure pump MIST generator With high pressure pipe Mist nozzles (Digital Humidity & Temp display), 700 ltr per day ,FLP Dehumidifier includes(a) Evaporator, condenser coils,(b) FLP motor,(c) FLP control panel having RH controller, Contactors, ON/OFF s/w, control Fuse, MCB etc(d) Hermetically sealed compressor,(e) Cabling in metal conduit,(f) FLP glands Supply-Power: 415 V AC 3 ph, 50 Hz, Classic Series, Suitable for- 799 cum and above Make-Sudhir/Shyam/DUEX/Pluto | ||||||
| 2.00 | Supply, installation, testing and commissioning of Servo Controlled Voltage Stabilizer(confirming to BIS 9815 :1994, reaffirmation 2019 incl latest amendments). Three phase,four wire (RYBN), 50 Hz, Naturally Oil cooled, indoor, unbalanced type, copper wound,metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to the required level having following specifications :- Capacity 200 KVA | 1 | Each Job | 4,90,000 ₹4,90,000 | 5,00,000 ₹5,00,000 | 48,750 ₹48,750 Lowest |
| 2.10(a) Capacity - 200 KVA, (b) Type - Suitable for unbalanced load and unbalanced input, (c) Input voltage – 360 V to 480 V, Input frequency 50 Hz, (d) Output voltage - Stabilized at 415 V+/- 1% without Spikes, (e) Rated frequency - 50 Hz, (f) Wave form distortion - Nil, (g) Response time - Not to exceed 10 milli seconds & PF at full load shall not exceed 0.95, (h) Sensitivity - (+/-) 1%, (j) Rate of correction - Not less than 50 Volts/Second between phase and neutral without under/over shooting., (k) Efficiency – Not Less than 98% & shall be free from distortion in wave forms, (l) Type of load three phase, unbalanced type, (m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter, (n) Operating temperature - For indoor use upto max ambient temp + 55°C, (o) Class of insulation - Class F, (p) Mode of operation - Automatic/manual, (q) Winding Temperature rise - Max 55°C (10°C above operating temp), (r) Transformer oil - IS 335 marked, Oil Capacity – As per IS/OEM., (s) Core - CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented), (t) Auto transformer (Variac) - 100 percent Copper wound Electrolytic Grade, (u) Losses - As per IS Norms, (v) Power Factor - Not less than 0.95, | ||||||
| 2.20(w) Protections with Indications & Alarm Systems : (i) Over load protections,(ii) Short Circuit protections,(iii) High/Low voltage cut off,(iv) By pass arrangement in case of Emergency,(v) Single phase sequence change /phase fail protection,(vi) Earth fault protection, (x) Standard Fittings & Accessories :(i) Name, Rating & Terminal Marking plate,(ii) Digital Temperature Indicator.,(iii) Plain Unidirectional CI Rollers.,(iv) Lifting Lugs.,(v) Earthing Terminals.,(vi) Oil Level Gauge.,(vii) Control Panel.,(viii) Automatic Module.,(ix) Cooling Radiators etc., (y) Other Fittings & Accessories : (i) Input/Incoming side 4P, MCCB, 400 A, 36 KA Breaking Capacity, Ics = 100% Icu suitable for 200 KVA Servo Voltage Stabilizer.,(ii) Output/Outgoing Side Heavy Duty Power Contactor of rating/type suitable for 200 KVA Servo Voltage Stabilizer. | ||||||
| 3.00 | Supply, installation,testing and commissioning of Servo Controlled Voltage Stabilizer(confirming to BIS 9815 :1994, reaffirmation 2019 incl latest amendments). Three phase,four wire (RYBN), 50 Hz, Naturally Oil cooled, indoor, unbalanced type, copper wound,metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to the required level having following specifications :- Capacity 75 KVA | 1 | Each Job | 2,45,000 ₹2,45,000 Lowest | 2,50,000 ₹2,50,000 | 2,58,900 ₹2,58,900 |
| 3.10(a) Capacity - 75 KVA,(b) Type - Suitable for unbalanced load and unbalanced input,(c) Input voltage – 360 V to 480 V, Input frequency 50 Hz,(d) Output voltage - Stabilized at 415 V+/- 1% without Spikes,(e) Rated frequency - 50 Hz,(f) Wave form distortion - Nil,(g) Response time - Not to exceed 10 milli seconds & PF at full load shall not exceed 0.95,(h) Sensitivity - (+/-) 1%,(j) Rate of correction - Not less than 50 Volts/Second between phase and neutral without under/over shooting.,(k) Efficiency – Not Less than 98% & shall be free from distortion in wave forms,(l) Type of load three phase, unbalanced type,(m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter,(n) Operating temperature - For indoor use upto max ambient temp + 55°C,(o) Class of insulation - Class F,(p) Mode of operation - Automatic/manual,(q) Winding Temperature rise - Max 55°C (10°C above operating temp),(r) Transformer oil - IS 335 marked, Oil Capacity – As per IS/OEM.,(s) Core - CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented),(t) Auto transformer (Variac) - 100 percent Copper wound Electrolytic Grade, (u) Losses - As per IS Norms,(v) Power Factor - Not less than 0.95,(w) Protections with Indications & Alarm Systems :(i) Over load protections,(ii) Short Circuit protections,(iii) High/Low voltage cut off,(iv) By pass arrangement in case of Emergency,(v) Single phase sequence change /phase fail protection,(vi) Earth fault protection,(x) Standard Fittings & Accessories :(i) Name, Rating & Terminal Marking plate,(ii) Digital Temperature Indicator.,(iii) Plain Unidirectional CI Rollers.,(iv) Lifting Lugs.,(v) Earthing Terminals.,(vi) Oil Level Gauge.,(vii) Control Panel.,(viii) Automatic Module.,(ix) Cooling Radiators etc.,(y) Other Fittings & Accessories :(i) Input/Incoming side 4P, MCCB, 400 A, 36 KA Breaking Capacity, Ics = 100% Icu suitable for 75 KVA Servo Voltage Stabilizer.,(ii) Output/Outgoing Side Heavy Duty Power Contactor of rating/type suitable for 75 KVA Servo Voltage Stabilizer. | ||||||
| 4.00 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft/loose soil for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed. | 90 | Cum | 60 ₹5,400 Lowest | 100 ₹9,000 | 145 ₹13,050 |
| 5.00 | Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm. | 54 | Cum | 50 ₹2,700 Lowest | 50 ₹2,700 Lowest | 100 ₹5,400 |
| 6.00 | Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed. | 35 | Cum | 50 ₹1,750 Lowest | 60 ₹2,100 | 150 ₹5,250 |
Tender Value
₹46.9 L
EMD Value
₹93,760
Closing Date
4 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Gorakhpur
GE AF Gorakhpur
PROVN OF FLAME PROOF HUMIDIFIER AND DE-HUMIDIFIER FOR CAT A DBs INSIDE WSA AND PROVISIONING OF COMMERCIAL POWER SUPPLY AT BOTH RWY ENDS FOR INSTALLATION OF NEW AWS AT AF STN UNDER GE AF GORAKHPUR.
2026_MES_748679_1
9410/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF Gorakhpur
Class D cat b (i)
8 documents required · 8 mandatory
₹500
GE AF Gorakhpur
₹93,760
Yes
9 Mar 2026
16 Jan 2026
10 Feb 2026
16 Jan 2026
4 Feb 2026
29 Jan 2026
16 Jan 2026 - 28 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur
Name of Work: PROVISIONING OF FLAME PROOF HUMIDIFIER AND DE HUMIDIFIER FOR CAT A DBS INSIDE WSA and PROVISIONING OF COMMERCIAL POWER SUPPLY AT BOTH RWY ENDS FOR INSTALLATION OF NEW AWS AT AFS GORAKHPUR.
Contract No.: GE(AF)/GKP/E-96 OF 2025-26 File No. 9410/E8 Serial Page No.15
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1.1 Miscellaneous (refrigerant circuit)-Drain tray: Fixed inside below coil.Drain: C- with hose pipe 1 ft length or E- Tank with Auto Overflow Protection arrangement, Compressor: Low power Emerson, Highly, GMCC make hermetically sealed- model dependent,Refrigerant Eco-friendly gas R 407 C,Technology: Standard rugged efficient Low Power,Blower- Almonard,Drain for hose pipe connection: 1/2th Inch,Noise level ~ 50-60 dB- model dependent,Condenser and Evaporator: Aluminum fins on copper tubes, Super-efficient Reciprocating cmpr design Electronic power saving control Auto defrost every 1 hr Ultra High pressure pump MIST generator With high pressure pipe Mist nozzles (Digital Humidity & Temp display), 700 ltr per day ,FLP Dehumidifier includes(a) Evaporator, condenser coils,(b) FLP motor,(c) FLP control panel having RH controller, Contactors, ON/OFF s/w, control Fuse, MCB etc(d) Hermetically sealed compressor,(e) Cabling in metal conduit,(f) FLP glands Supply-Power: 415 V AC 3 ph, 50 Hz, Classic Series, Suitable for- 799 cum and above Make-Sudhir/Shyam/DUEX/Pluto 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
2 Supply, installation, testing and commissioning of Servo Controlled Voltage Stabilizer(confirming to BIS 9815 :1994, reaffirmation 2019 incl latest amendments). Three phase,four wire (RYBN), 50 Hz, Naturally Oil cooled, indoor, unbalanced type, copper wound,metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to the required level having following specifications :- Capacity 200 KVA Each Job Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
2.1 (a) Capacity - 200 KVA, (b) Type - Suitable for unbalanced load and unbalanced input, (c) Input voltage – 360 V to 480 V, Input frequency 50 Hz, (d) Output voltage - Stabilized at 415 V+/- 1% without Spikes, (e) Rated frequency - 50 Hz, (f) Wave form distortion - Nil, (g) Response time - Not to exceed 10 milli seconds & PF at full load shall not exceed 0.95, (h) Sensitivity - (+/-) 1%, (j) Rate of correction - Not less than 50 Volts/Second between phase and neutral without under/over shooting., (k) Efficiency – Not Less than 98% & shall be free from distortion in wave forms, (l) Type of load three phase, unbalanced type, (m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter, (n) Operating temperature - For indoor use upto max ambient temp + 55°C, (o) Class of insulation - Class F, (p) Mode of operation - Automatic/manual, (q) Winding Temperature rise - Max 55°C (10°C above operating temp), (r) Transformer oil - IS 335 marked, Oil Capacity – As per IS/OEM., (s) Core - CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented), (t) Auto transformer (Variac) - 100 percent Copper wound Electrolytic Grade, (u) Losses - As per IS Norms, (v) Power Factor - Not less than 0.95, 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
2.2 (w) Protections with Indications & Alarm Systems : (i) Over load protections,(ii) Short Circuit protections,(iii) High/Low voltage cut off,(iv) By pass arrangement in case of Emergency,(v) Single phase sequence change /phase fail protection,(vi) Earth fault protection, (x) Standard Fittings & Accessories :(i) Name, Rating & Terminal Marking plate,(ii) Digital Temperature Indicator.,(iii) Plain Unidirectional CI Rollers.,(iv) Lifting Lugs.,(v) Earthing Terminals.,(vi) Oil Level Gauge.,(vii) Control Panel.,(viii) Automatic Module.,(ix) Cooling Radiators etc., (y) Other Fittings & Accessories : (i) Input/Incoming side 4P, MCCB, 400 A, 36 KA Breaking Capacity, Ics = 100% Icu suitable for 200 KVA Servo Voltage Stabilizer.,(ii) Output/Outgoing Side Heavy Duty Power Contactor of rating/type suitable for 200 KVA Servo Voltage Stabilizer. 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
3.1 (a) Capacity - 75 KVA,(b) Type - Suitable for unbalanced load and unbalanced input,(c) Input voltage – 360 V to 480 V, Input frequency 50 Hz,(d) Output voltage - Stabilized at 415 V+/- 1% without Spikes,(e) Rated frequency - 50 Hz,(f) Wave form distortion - Nil,(g) Response time - Not to exceed 10 milli seconds & PF at full load shall not exceed 0.95,(h) Sensitivity - (+/-) 1%,(j) Rate of correction - Not less than 50 Volts/Second between phase and neutral without under/over shooting.,(k) Efficiency – Not Less than 98% & shall be free from distortion in wave forms,(l) Type of load three phase, unbalanced type,(m) Metering - Digital display Voltmeter/Ammeter with multi-functional meter,(n) Operating temperature - For indoor use upto max ambient temp + 55°C,(o) Class of insulation - Class F,(p) Mode of operation - Automatic/manual,(q) Winding Temperature rise - Max 55°C (10°C above operating temp),(r) Transformer oil - IS 335 marked, Oil Capacity – As per IS/OEM.,(s) Core - CRGO M4 Grade/CRNO (Cold Roll Grain Oriented)/ (Cold Rolled Non-Oriented),(t) Auto transformer (Variac) - 100 percent Copper wound Electrolytic Grade, (u) Losses - As per IS Norms,(v) Power Factor - Not less than 0.95,(w) Protections with Indications & Alarm Systems :(i) Over load protections,(ii) Short Circuit protections,(iii) High/Low voltage cut off,(iv) By pass arrangement in case of Emergency,(v) Single phase sequence change /phase fail protection,(vi) Earth fault protection,(x) Standard Fittings & Accessories :(i) Name, Rating & Terminal Marking plate,(ii) Digital Temperature Indicator.,(iii) Plain Unidirectional CI Rollers.,(iv) Lifting Lugs.,(v) Earthing Terminals.,(vi) Oil Level Gauge.,(vii) Control Panel.,(viii) Automatic Module.,(ix) Cooling Radiators etc.,(y) Other Fittings & Accessories :(i) Input/Incoming side 4P, MCCB, 400 A, 36 KA Breaking Capacity, Ics = 100% Icu suitable for 75 KVA Servo Voltage Stabilizer.,(ii) Output/Outgoing Side Heavy Duty Power Contactor of rating/type suitable for 75 KVA Servo Voltage Stabilizer. 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
BOQ_838452.xls
BOQ • 0.77 MB
TenderCA96.pdf
Tender Documents • 1.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .