Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 CrAccepted-AOC OLD AIRFIELD ROAD RAWALPORA WANBAL SRINAGAR 190005 J K | SRINAGAR | SRINAGAR | J K | 190005 | ₹6.5 Cr | L1 | Accepted-AOC Being Lowest and reasonable. |
| 2 | L2₹6.6 Cr+₹10.6 L (1.64%)Rejected-Finance | ₹6.6 Cr+₹10.6 L (1.64%) | L2 | Rejected-Finance Not Being Lowest. |
| 3 | L3₹6.7 Cr+₹21.1 L (3.26%)Rejected-Finance CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹6.7 Cr+₹21.1 L (3.26%) | L3 | Rejected-Finance Not Being Lowest. |
| 4 | L4₹6.9 Cr+₹39.3 L (6.08%)Rejected-Finance | ₹6.9 Cr+₹39.3 L (6.08%) | L4 | Rejected-Finance Not Being Lowest. |
| 5 | L5₹6.9 Cr+₹46.5 L (7.19%)Rejected-Finance NATIONAL HIGHWAY BYE PASS CROSSING ATHWAJAN SRINAGAR 191101 KASHMIR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 191101 | ₹6.9 Cr+₹46.5 L (7.19%) | L5 | Rejected-Finance Not Being Lowest. |
Tender Value
₹7.6 Cr
EMD Value
₹7.0 L
Closing Date
7 Nov 2024, 6:00 pmClosed
CHIEF ENGINEER AIR FORCE UDHAMPUR ZONE
CHIEF ENGINEER AIR FORCE OFFICE UDHAMPUR ZONE
CEAFU-08-2024-25 PROVN OF SECURITY FENCE BETWEEN TECHNICAL AND DOMESTIC AREA AT AIR FORCE STN SRINAGAR
2024_MES_670683_1
CEAFU-08-2024-25
Open Tender
Civil Works
Lump-sum
610 days
Srinagar
As per policy in vogue and as per tender documents
9 documents required · 9 mandatory
₹3,000
GE(P) AF SRINAGAR
₹7.0 L
UDHAMPUR
3 Jan 2025
3 Sept 2024
15 Nov 2024
3 Sept 2024
7 Nov 2024
31 Oct 2024
6 Sept 2024 - 10 Sept 2024
12 Sept 2024
Amount
SCHEDULE `A' PART-I (BUILDING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Contruction of Sentry Post, RCC framed construction, Galvalume sheet roofing, with permanent specifications complete all as specified and as shown in drawings.
Total amount of Schedule 'A' PART-I (BUILDING WORK)
Total amount of Sch 'A' PART-II (Sec-I) (INTERNAL ELECTRIC SUPPLY)
SCHEDULE `A' PART-II (Sec-II) (INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing 240V, 10 KA 'C' curve, 6-32 Amp capacity, miniature circuit breaker (MCB) of single poles in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve, 6-32 Amp capacity, miniature circuit breaker (MCB) of single poles & netural in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanized earth lead wire by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour of the following: - (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note: (1) The earth resistance shall be less than 1 ohms after completion of earthing. If the desired earth resistance is not obtained, the earthing shall be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Total amount of Sch 'A' PART-II (Section-II) (INTERNAL ELECTRIC SUPPLY WORK)
Total amount of Sch 'A' PART-III (ROAD, PATH AND HARD STANDING WORKS)
Total amount of Sch 'A' PART-IV (Section-I) (FENCING AND GATE WORK)
SCHEDULE `A' PART-IV (SECTION-II) (FENCING AND GATE WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing for 1050mm dia punched type concertina coil (50 turns per coil) 0.50mm thick low carbon heavy galvanised cold steel as per IS:513, conform to heavy galvanised high tensile spring steel wire as per IS-4454 and conforming to heavy duty steel clips as per IS-2062 deep drawn quality and galvanising coating (minimum 230 GSM) has medium barbs of specification barb length 24+1mm pitch between two barbs 35+1mm and approximate weight of coil shall be 15.50 kg per coil and shall not be less than as per relevant IS specifications all as specified and as directed.
Supply and fixing for 610mm dia punched type concertina coil (50 turns per coil) 0.50mm thick low carbon heavy galvanised cold steel as per IS:513, conform to heavy galvanised high tensile spring steel wire as per IS-4454 and conforming to heavy duty steel clips as per IS-2062 deep drawn quality and galvanising coating (minimum 230 GSM) has medium barbs of specification barb length 24+1mm pitch between two barbs 35+1mm and weight of coil shall not be less than as per relevant IS specifications all as specified and as directed.
Total amount of Sch 'A' PART-IV (SECTION-II) (FENCING AND GATE WORK)
Total amount of Sch 'A' PART-V (Section-I) (EXTERNAL ELECTRIFICATION WORKS)
Sch 'A' Part-V (Section-II) (EXTERNAL ELECTRIFICATION WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fixing LED flood light fittings 120 watt, for operating voltage between 140V to 300V, system efficiency not less than 120 lumen/watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, conforming to LM79 and LM80 standards or as per IS-16104: 2012 and IS-16106: 2012 for estimated life span of minimum 50000 hours consisting of high/low voltage cut off, maintenance free isolated electronic driver with over voltage protection, surge protection and other safety test as per IS 15885 Part-2/Sec 13, Low THD, PMMA grade high quality transmittance lens, Epoxy powder coated Die cast aluminium housing (Heat sink) with UV stabilized optics, polycarbonate LENS for synnetrical light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and directed.
Supply and fixing hot pressed moulded Glass reinforced polyester sheet moulding compound (SMC) Junction box of dimensions 250mm x 200mm x 100mm, SMC conforming to IS: 13410:1992 Grade S 1, thickness of SMC sheet not less than 1.5mm, outdoor type, single door hinged with front side opening, weather proof, suitable locking arrangement at front, arrangement for incoming and out going cable entry at the bottom, earthing arrangement using one No. of Earthing bolt of MS with 2 nuts and 2 washers provided on RH side of box, Earthing sign has to be provided near to earthing bolt complete all as specified and comprising of the followings items as under:- (a) single phase and neutral bus bar duly colour coded of capacity 100 Amps using aluminium strips of size 25mm x 4mm mounted on epoxy resin base insulators, drilled holes for cable connection on bus bar including provision of PVC cable of suitable size and length from bus bar to MCB. (b) MCB 'C' curve, SP 6-32 Amps - 01 No (c) Provision of clamp for mounting on pole/wall, clamp made from 20mm x 1.5mm flat iron of suitable shape and length duly fixed with nuts & bolts on the rear side of box
Supply and fixing cable route indicator at the distance of 50 mtrs or as per site requirement, each made of 45 x 45 x 5mm angle iron, 60mm long embedded in PCC block of suitable size with moulded letters "LT Cable" suitably inscribed on 8mm thick CI circular plate, 100 mm dia including painting with two coats of synthetic enamelled paint over a coat of red oxide primer, including necessary PCC 1:3:6, type C-2 (using 40 mm graded aggregates), block of suitable size and necessary earth work and excavation complete all as specified and directed.
Material and labour for cutting of PCC/hard standing/WBM road cutting not exceeding 20 cm in width not exceeding 30 cm in depth for passing LT cable and making good disturbed surface to match with the xisting surfaces by using old and new material i.e bitumen/PCC 1:3:6 type C-1 (using 20mmgraded crushed stone aggregate) complete all as specified and directed.
Total amount of Sch 'A' PART-V (SEC-II) (EXTERNAL ELECTRIFICATION WORKS)
Total amount of Sch 'A' Part-VI (SITE CLEARANCE, EXCAVATION AND EARTH WORK)
Total amount of Sch 'A' -VII (DEMOLITION WORK)
NOTE: Amount against schedule of credit for retrieved materials mentioned under relevant part of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during award of contract.
M/S Rather and Sons (BID ID -3156243)
M M SHAWL Engineers and contractors pvt ltd (BID ID -3160150)
Chandra Construction (BID ID -3159811)
Hassan Road Construction Co Pvt Ltd (BID ID -3160076)
ALCO Engineers Private Limited (BID ID -3160082)
Jk Engineering Construction Co. (BID ID -3159886)
mirco builders (BID ID -3159974)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.rar
Tender Documents • 30.98 MB
Tenderdocument_2.rar
Tender Documents • 31.77 MB
Tenderdocument.pdf
Tender Documents • 2.43 MB
Tenderdocument_3.rar
Tender Documents • 16.50 MB
BOQ.xls
BOQ • 0.37 MB
Tenderdocument_4.rar
Tender Documents • 20.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .