Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAdmitted-Finance | ₹3.5 L | L1 | Admitted-Finance |
| 2 | L2₹3.8 LAdmitted-Finance | ₹3.8 L | L2 | Admitted-Finance |
| 3 | L3₹4.2 LAdmitted-Finance | ₹4.2 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RAMBIR SINGH L3 | MO TANVIR ANSARI L1 | MS CONSTRUCTION CO L2 |
|---|---|---|---|---|---|---|
| 1.00Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : | ||||||
| 1.10 | 3 mm thick | 600 | One Square Metre | 447 ₹2.7 L | 390 ₹2.3 L | 375 ₹2.3 L |
| 2.00Grading roof for water proofing treatment with | ||||||
| 2.10 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) | 1 | One Cubic Metre | 8,000 ₹8,000 | 3,500 ₹3,500 | 7,000 ₹7,000 |
| 2.20 | Cement mortar 1:4 (1cement : 4 coarse sand) | 1 | One Cubic Metre | 9,500 ₹9,500 | 3,500 ₹3,500 | 8,500 ₹8,500 |
| 3.0012 mm average thickness cement plaster of mix : (for repair of Brick work,perapet or terrace top etc .) | ||||||
| 3.10 | 1:6 (1 cement: 6 fine sand) | 50 | One Square Metre | 280 ₹14,000 | 300 ₹15,000 | 350 ₹17,500 |
| 4.00Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work | ||||||
| 4.10 | 15 mm nominal outer dia. Pipes. | 10 | One Running Metre | 290 ₹2,900 | 10 ₹100 | 150 ₹1,500 |
| 4.20 | 20 mm nominal outer dia. Pipes. | 10 | One Running Metre | 300 ₹3,000 | 250 ₹2,500 | 175 ₹1,750 |
Tender Value
₹4.8 L
EMD Value
₹9,500
Closing Date
17 Apr 2026, 6:00 pmClosed
Nodal Officer (Tender)
O/o Sr. Chief Engineer(Civil) BSNL MP Civil Zone Block-C, BDA Flats, First Floor,Vidya Nagar, Behind Petrol Pump Hoshangabad Road , Bhopal (M.P.)- 462026
Water proofing repair work of T4 BSNL SQ Blocks SQ 1 to 12 P and T Colony Char Imli Bhopal
2026_BSNL_274349_1
NIT NO. 02/EE(C) /BSNL-BPL/2026-27
Open Tender
Civil Works
60 days
Bhopal
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Account Officer A and B Oo CGMT BSNL Bhopal
₹9,500
29 Apr 2026
9 Apr 2026
20 Apr 2026
9 Apr 2026
17 Apr 2026
9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : | |||||
| 1.1 | 3 mm thick | - | One Square Metre | - | - |
| 2Grading roof for water proofing treatment with | |||||
| 2.1 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) | - | One Cubic Metre | - | - |
| 2.2 | Cement mortar 1:4 (1cement : 4 coarse sand) | - | One Cubic Metre | - | - |
| 312 mm average thickness cement plaster of mix : (for repair of Brick work,perapet or terrace top etc .) | |||||
| 3.1 | 1:6 (1 cement: 6 fine sand) | - | One Square Metre | - | - |
| 4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work | |||||
| 4.1 | 15 mm nominal outer dia. Pipes. | - | One Running Metre | - | - |
| 4.2 | 20 mm nominal outer dia. Pipes. | - | One Running Metre | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.55 MB
BOQ_320270.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid