Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Being a lowest tenderer | |
| 2 | L2₹42.3 L+₹1.7 L (4.13%)Rejected-Finance 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | L2 | Rejected-Finance Being a 2nd lowest tenderer | |
| 3 | L3₹42.3 L+₹1.7 L (4.17%)Rejected-Finance 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L3 | Rejected-Finance Being a 3rd lowest tenderer | |
| 4 | L4₹47.6 L+₹7.0 L (17.3%)Rejected-Finance NO 6 1 ALAGAR PERUMAL KOIL MAIN STREET VADAPALANI CHENNAI 600 026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | L4 | Rejected-Finance Being a 4thlowest tenderer | |
| 5 | L5₹49.8 L+₹9.2 L (22.6%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L5 | Rejected-Finance Being a5thlowest tenderer |
Tender Value
₹42.5 L
Closing Date
12 Dec 2024, 6:00 pmClosed
Shri Vishal Garg, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
PROVISION OF HT PANELS AND CONNECTED ACCESSORIES RMU IN PO COLONY OF OTA CHENNAI UNDER GE STM CHENNAI
2024_MES_684056_1
86572/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE STM
As per tender documents
8 documents required · 8 mandatory
₹500
GE STM CHENNAI
Yes
10 Jan 2025
14 Nov 2024
19 Dec 2024
14 Nov 2024
12 Dec 2024
28 Nov 2024
14 Nov 2024 - 21 Nov 2024
Amount
Earthwork excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil for laying cables / pipes / erection of poles etc complete all as specified and as directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and all as directed.
Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25 cm each complete all as specified and directed.
M&L for fine seived excavated dry soil laid to the required width of trench at botom and top of cable as cushioning to cable complete all as specified . Note :- Thickness shall be measured after punning
Supply and laying 3 core 120 sqmm HT UG Cable XLPE insulated with multistranded aluminium conductor armoured with galvanised steel wire / taps 11000 volts grade conforming to IS specifications in trenches/poles/wall etc including taking out and removing old unservicable cable and deposited to MES store yard complete all as specified and as directed .
Dismantling of four pole structure including GOD, insulators, cross arm, ACSR Conductor, lighting arrestor complete and deposited to MES store yard complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing, and commissioning of 11kV Extensible Ring Main Unit, Outdoor type, Motorized, 3 Way with IP54 floor Mounted with metering enclosure comprising of vacuum circuit breaker - 1 No. as incomer & Motorized Isolator (LBS) - 2 Nos. as rated 630A having short circuit capacity 21kA/3Sec, permanently enclosed in a tank 3.15 mm thickness, made up of MS sheet or equiivalent as IP 67 protection with following accessories complete all as specified and as directed by Engineer-in-Charge.Make :CG/ ABB
CIRCUIT BREAKER / VCB:
Air insulated cable boxes for bottom entry of single run of 3 core cable up to 300 sqmm -01 No
Over current & Earth Fault Relay with digital display & Self Powered relay-1No (Make: CGPISL, Type: CGI 14S)
Set of CTs for Metering & protection circuit mounted on Cable box of ratio 100-50/1+1A, 5P10,CL0.5, 2.5VA - 1No
Capacitive Voltage Indicators –LED Display - 1No
Low energy Tripping Coil for tripping the circuit breaker in fault condition -1No
Local 'PUSH TO TRIP' mechanism for emergency trip -1No
Set of Right Angle boots (Non touch proof type) - 1No
Set of Right Angle boots (Non touch proof type) -1No
Set of Right Angle boots (Non touch proof type) -1No
Space Heater with thermostat -1No
RING SWITCH / ISOLATOR/LOAD BREAK SWITCH:
630 Amps. Triple pole, single break, 3-position ('ON', 'OFF' and 'EARTH') Ring Main Switches, each with independent Motor charged spring mechanism and fully rated earth -1No
Air insulated cable boxes for bottom entry of single run of 3-core cable up to 300 sqmm -1No
Set (3nos) of Cable Bushings -1No
Capacitive Voltage Indicators –LED Display -1No
Mimic diagram on front panel, complete with status indicators (ON-OFF-EARTH) - 1No
Set of Right Angle boots (Non touch proof type) -1No
Fault passage indicator -1No
Set of CTs for Metering circuit mounted on Cable box of ratio 100-50/1A, CL0.5, 2.5VA - 1No
GENERAL:
The combined unit shall consist of the following:
Set of 630 Amps continuously rated COPPER bus bars -1No
Set of positive standard mechanical interlocks to avoid unsafe operation -1No
Mimic diagram on front panel, complete with status indicators (ON-OFF-EARTH) - 1No
Provision for padlocking for Open, Close, Earth position in correct sequence-01 No
Manometer for indicating SF6 gas pressure with green & red zone -01 No
Set of hooks strong enough to take the load of entire unit while lifting by means of crane -01 No
SF6 tank of 3mm stainless steel, robotically welded construction (degree of protection IP67) -01No
External stud for earthing connections -01 No
Outer Enclosure (cladding) constructed with CRCA sheets (having degree of protection IP54) -01 No
Cable Cleat for LBS & VCB functions -01 No
Operating handle -01 No
Jointing Box – as per requirement
Paint Shade : The unit shall be painted in RAL 7035 paint shade.
PT Panel : (a) Set (3nos) Bus Connected PTs of 11000/sqrt3/110/sqrt3, Class 0.5, 50VA -1No (b) Battery _ 12Vx2, 7AH Rating -01No (c) Battery charger,5 Amp -01 No
Note : - (a) The cost of electrical and mechanical interlocking between VCBs as per site conditions shall deemed to be included in the quoted rate (b) Quoted rate shall be inclusive of PCC bedding / foundation of required size as per panel board size and plinth protection shall be 0.6 m width required for installation of the Panel on ground as per Manufacturers recommendation. (c) The quoted rate shall deemed to be inclusive of the following:- (i) Primary injection test & Secondary injection test individually at site after erection and before commissioning (ii) RMU drawings shall be approved by the Accepting officer before placing the order (iii) Factory inspection test shall be carried out in the presence of Representative of Accepting officer at factory premises (iv) All other makes of components pertains to RMU which is not specified in the CA shall be the reputed make as recommended by the OEM (v) All miscellaneous items required for satisfactory completion of the job as per Manufacturer's instruction (vi) Pre - commissioning test shall be carried out by the SEI / EI before issue of completion certificate of the work (vii) No channel partners for panels shall be accepted.(e) Anything missed out of the above, but technically required for efficient working of RMU shall deemed to be included in the quoted rate.
Supply, Installation, testing, and commissioning of 11kV Extensible Ring Main Unit, Outdoor type, Motorized, 5 Way with IP54 floor Mounted with metering enclosure comprising of vacuum circuit breaker - 2 No. as incomer & Motorized Isolator(LBS) - 3 Nos. as rated 630A having short circuit capacity 21kA/3Sec, permanently enclosed in a tank made by 3.15 mm Thickness, made up of MS sheet or equiivalent as IP 67 protection complete all as specified and as directed by Engr-In-Charge.Make CG/ ABB
CIRCUIT BREAKER / VCB:
Air insulated cable boxes for bottom entry of single run of 3-core cable up to 300sq. mm. -01 No
Over current & Earth Fault Relay with digital display & Self Powered relay (Make: CGPISL, Type: CGI 14S) -01 No
Set of CTs for Metering & protection circuit mounted on Cable box of ratio 100-50/1+1A, 5P10,CL0.5, 2.5VA - 01 No
Capacitive Voltage Indicators –LED Display - 01 No
Low energy Tripping Coil for tripping the circuit breaker in fault condition -01 No
Local 'PUSH TO TRIP' mechanism for emergency trip -01 No
Set of Right Angle boots (Non touch proof type) -01 No
RING SWITCH / ISOLATOR/LOAD BREAK SWITCH:
630 Amps. Triple pole, single break, 3-position ('ON', 'OFF' and 'EARTH') Ring Main Switches, each with independent Motor charged spring mechanism and fully rated earth switch -01 No
Air insulated cable boxes for bottom entry of single run of 3-core cable up to 300 sqmm.
Set (3nos) of Cable Bushings -01 No
Capacitive Voltage Indicators –LED Display
Mimic diagram on front panel, complete with status indicators (ON-OFF-EARTH) -01 No
Set of Right Angle boots (Non touch proof type) -01 No
Fault passage indicator -01 No
Set of CTs for Metering circuit mounted on Cable box of ratio 100-50/1A, CL0.5, 2.5VA -01 No
GENERAL:
The combined unit shall consist of the following :
Set of 630 Amps continuously rated COPPER bus bars - 01 No
Set of positive standard mechanical interlocks to avoid unsafe operation -01 No
Mimic diagram on front panel, complete with status indicators (ON-OFF-EARTH) -01 No
Provision for padlocking for Open, Close, Earth position in correct sequence -01 No
Manometer for indicating SF6 gas pressure with green & red zone -01 No
Set of hooks strong enough to take the load of entire unit while lifting by means of crane -01 No
SF6 tank of 3mm stainless steel, robotically welded construction (degree of protection IP67) -01 No
External stud for earthing connections-01 No
Outer Enclosure (cladding) constructed with CRCA sheets (having degree of protection IP54) -01 No
Cable Cleat for LBS & VCB functions - 01 No
Operating handle -01 No
Jointing Box –as per requirement
Paint Shade:
The unit shall be painted in RAL 7035 paint shade.
PT Panel:
Set (3nos) Bus Connected PTs of 11000/sqrt3/110/sqrt3, Class 0.5, 50VA - 01 NO
Battery _ 12Vx2, 7AH Rating -01 NO
Battery charger,5 Amp -01 No
Note : - (a) The cost of electrical and mechanical interlocking between VCBs as per site conditions shall deemed to be included in the quoted rate (b) Quoted rate shall be inclusive of PCC bedding / foundation of required size as per panel board size and plinth protection shall be 0.6 m width required for installation of the Panel on ground as per Manufacturers recommendation. (c) The quoted rate shall deemed to be inclusive of the following:- (i) Primary injection test & Secondary injection test individually at site after erection and before commissioning (ii) RMU drawings shall be approved by the Accepting officer before placing the order (iii) Factory inspection test shall be carried out in the presence of Representative of Accepting officer at factory premises (iv) All other makes of components pertains to RMU which is not specified in the CA shall be the reputed make as recommended by the OEM (v) All miscellaneous items required for satisfactory completion of the job as per Manufacturer's instruction (vi) Pre - commissioning test shall be carried out by the SEI / EI before issue of completion certificate of the work (vii) No channel partners for panels shall be accepted.(e) Anything missed out of the above, but technically required for efficient working of RMU shall deemed to be included in the quoted rate.
Supply and lay reinforced precast concrete cable cover, class HV, type 1, flat of size 300 mm x 180 mm x 40 mm complete all as specified
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 95 sqmm.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size3 core120 sqmm.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core120 sqmm
Supply and lay GI pipe 100 mm bore medium Grade including all necessary fittings complete all as specified and directed .
M&L for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron/steel strip of size 32X6 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm dia and connected to main control board all as shown in Electrical plate No 5 of SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoad dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.
HUMERS INFRATECH (BID ID -3186752)
rvelectricals (BID ID -3181983)
Veera Electrical (BID ID -3182025)
devan enterprises (BID ID -3181894)
Sree Nandhees Technologies Pvt Ltd (BID ID -3181652)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .