| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.6 LAccepted-AOC OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | ₹80.6 L Quoted ₹81.3 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹89.3 L+₹8.0 L (9.83%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹89.3 L+₹8.0 L (9.83%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹1.0 Cr+₹22.8 L (28.0%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | ₹1.0 Cr+₹22.8 L (28.0%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹1.1 Cr+₹23.8 L (29.3%)Rejected-Finance POST MISAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | ₹1.1 Cr+₹23.8 L (29.3%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹1.1 Cr+₹24.9 L (30.6%)Rejected-Finance | ₹1.1 Cr+₹24.9 L (30.6%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
30 Sept 2024, 6:00 pmClosed
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
CERTAIN REPAIRS TO DAY TO DAY INTERNAL ELECTRIFICATION WORKS OF OTM ACCN IN PH-I AND PH-II AREA UNDER GE NARANGI
2024_MES_669306_1
8809/NAR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Narangi
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE Narangi
₹1.8 L
Yes
14 Nov 2024
31 Aug 2024
1 Oct 2024
31 Aug 2024
30 Sept 2024
21 Sept 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, bell, buzzer, sockets etc. removing materials away from site for taking credit from contractor as per rates in Schedule of credi and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed by Engineer-in-Charge at site.
M&L Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for One light or fan point controlled by one 5 Amps switch one way complete all as specified and as directed by Engineer-in-Charge at site.
All as per item No 2 here-in-before but for One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables complete all as specified and as directed by Engineer-in-Charge at site.
All as per item No 2 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board complete all as specified and as directed by Engineer-in-Charge at site.
All as per item serial No 2 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches complete all as specified and as directed by Engineer-in-Charge at site.
All as per item No 2 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for one 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly complete all as specified and as directed by Engineer-in-Charge at site.
M&L Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Conduit Conclead with all accessories including fabricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and as directed by Engineer-in-Charge at site.
All as per item No 7 here-in-before but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables complete all as specified and as directed by Engineer-in-Charge at site.
All as per item No 7 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board, complete all as specified and as directed by Engineer-in-Charge at site.
All as per item serial No 7 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches, complete all as specified and as directed by Engineer-in-Charge at site.
All as per item No 7 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly complete all as specified and as directed by Engineer-in-Charge at site.
All as per item No 2 here-in-before but wiring with 4 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 4 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly complete all as specified and as directed by Engineer-in-Charge at site.
S&F switch piano, flush type, single pole, one way, 5 Amps, 230 volt complete all as specified and as directed by Engineer-in-Charge at site.
S&F Bell push switch, flush type, 5 Amps, 230 volt complete all as specified and as directed by Engineer-in-Charge at site.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed by Engineer-in-Charge at site.
S&F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush typecomplete all as specified and as directed by Engineer-in-Charge at site.
S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed by Engineer-in-Charge at site.
S&F ceiling rose surface bakelite 65x50mm three terminalcomplete all as specified and as directed by Engineer-in-Charge at site.
S&F lamp holder, insulated, PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or square box, complete all as specified and as directed by Engineer-in-Charge at site.
S&F stepped type electronic fan regulator, two module size, flush type, complete all as specified and as directed by Engineer-in-Charge at site.
S&F Buzzer, Ding Dong bell, AC, 230 volts, single pole,complete all as specified and as directed by Engineer-in-Charge at site.
S&F Bell, AC, 230 volts, single pole, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS Single pole and neutral enclosure with a two pin and earth plug and socket, with one single pole MCB 20 Amp 240 V complete all as specified and as directed by Engineer-in-Charge at site.
M&L IN REPAIRS, for submain wiring with and including 2 runs of 1.5 sqmm, single core ,FR-LSH, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn through and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 1.5 sqmm single core, FR-LSH, PVC insulated & unsheathed copper conductor as continuos earth wire and connecting to existing main switch board / distribution board to earth dolly of each building / qtr and testing on completion including taking down old wiring in any type of conduit complete all as specified and as directed by Engineer-in-Charge at site. Note: 2 run of 1.5 Sqmm cable and 1 run of 1.5 Sqmm earth cable along with conduit shall be measured as one run / unit.
M&L IN REPAIRS, for wiring with 2 runs of 2.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuous earth wire and connecting to existing main switch board / distribution board to earth dolly of each building / qtr and testing on completion including taking down old wiring in any type of conduit complete all as specified and as directed by Engineer-in-Charge at site. Note: 2 run of 2.5 Sqmm cable and 1 run of 2.5 Sqmm earth cable along with conduit shall be measured as one run / unit.
M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.
M&L IN REPAIRS, for Sub main wiring with 2 runs of 6.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuous earth wire and connecting to existing main switch board / distribution board to earth dolly of each building / qtr and testing on completion including taking down old wiring in any type of conduit complete all as specified and as directed by Engineer-in-Charge at site. Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.
Supply and fixing IN REPAIRS, batten type LED light fitting 1x 20W, 220V, AC decorative type with internal SPD upto 4kV and overload voltage protection upto 440V including flexible copper conductor cable of suitable size from ceiling rose complete all as specified. Make : Havells Cat Part No:LUMILINENEOBS20WLED865SPCWH or equivalent in Bajaj/Phillips
S&F IN REPAIRS, wall mounted decorative luminaire in design mesh suitable for 10W LED lamp B22 base ,including lamp of 10watt complete all as specified and as directed by Engineer-in-Charge at site. Make -Havells Cat Part: Glaze wall Light or equivalent Phillips /Bajaj
S & F IN REPAIRS, LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-Charge at site. Make : Bajaj Cat Part No: BIBWP10WLED or equivalent Havells/ Phillips
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I. NOTES:- The rates quoted for this item includes for Excavation and earth work in any type of strata or drilling hole for electrode, P.C.C. pit and C.I. cover, Funnel with watering pipe, wire mesh and copper lugs etc. as specified, G.I. protection pipe of size specified for protection of earthing lead from mechanical injury or tempering, Test point and any extra length of main earthing lead beyond 7.5 metres, Connecting lead from test point to main switch or switch board or equipment to be earthed, testing after completion and if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Taking down ceiling fans 1400mm / 1200mm sweep, sealing cable end, dismantling blade & removing the same away from site to workshop for repairs including replacement of defective parts such as bearing, rubber reel, down rod, canopy etc complete and refixing on same location or other location of any type / make and size carefully on fan hook, including transporting of ceiling fans from any location inside army area to MES E/M store yard and back after repairing, including provn of NEW twisted three core flexible wire upto 0.7 mtrs long of suitable size (ISI marked), complete all as specified and as directed by Engineer-in-Charge at site. NOTE:- (i) Defective/unserviceable parts replaced will be paid separately under respective item of Sch 'A' as Supply only. (ii) Labour element required for replacing defective parts of ceiling fans is included in the rate quoted for above item.
M & L for painting of ceiling fan complete with blades, in situ with synthetic enamel paint by spraying including filling cavities with one coat filler after cleaning all dust etc. complete all as specified and as directed by Engineer-in-Charge at site.
M & L for painting of exhaust fan complete with blades, in situ with synthetic enamel paint by spraying including filling cavities with one coat filler cleaning all dust etc. complete all as specified and as directed by Engineer-in-Charge at site.
Rewinding Ceiling fan by cutting the existing copper winding of ceiling fan 1200/1400 mm capacity and make any type, with super enamelled copper wire of suitable size mathing the existing including all insulating materials varnishing and neating complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge at site.
Rewinding Ceiling fan by cutting the existing copper winding of ceiling fan Heavy Duty old model 1200/1400 mm capacity and make any type, with super enamelled copper wire of suitable size mathing the existing including all insulating materials varnishing and neating complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge at site. NOTE FOR BOQ ITEM NO 35 & 36:- Old unserviceable / defective copper winding obtained from above item shall be recorded by BOO for credit from contractor at rates mentioned in Schedule of credit
S&F only fan bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed by Engineer-in-Charge at site.
Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and as directed by Engineer-in-Charge at site.
Supply only down rod made of 15mm dia GI pipe heavy duty 45 cm long incl machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and as directed by Engineer-in-Charge at site.
Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and as directed by Engineer-in-Charge at site.
Taking down exhaust fan of size 200mm to 400mm sweep of any make and removing the same away from site to workshop for repairs including replacement of worn out/defective unserviceable parts (wherever necessary) such as bearing, capacitors, condensor spacer etc. stripping of fan washing thoroughly of bearing/bush by petrol, washing fan blade body etc thoroughly, greasing, assembling the fan complete and refixing on same location or other location of any type / make and size carefully, including transporting of exhaust fans from any location inside army area to MES E/M store yard and back after repairing, including provn of NEW twisted twin core flexible wire upto 0.7 mtrs long of suitable size (ISI marked), complete all as specified and as directed by Engineer-in-Charge at site. NOTE:- (i) Defective/unserviceable parts replaced will be paid separately under respective item of Sch 'A' as Supply only. (ii) Labour element required for replacing defective parts of ceiling fans is included in the rate quoted for above item.
M&L for Rewinding the armature for 200mm to 400mm sweep exhaust fan, of any make, with super enamelled copper wire of suitable size with and including all insulating materials, varnishing, including cutting the existing copper winding with super enamelled copper wire of suitable size, with and including all insulating materials, varnishing, complete including satisfactory testing of exhaust fan on full load to entire satisfaction of Engineer-in-Charge, complete all as specified and as directed by Engineer-in-Charge at site. NOTE :- Old unserviceable / defective copper winding obtained from above item shall be recorded by BOO for credit from contractor at rates mentioned in Schedule of credit
Supply only ball bearing of size suitable for exhaust/wall fan upto 400 mm sweep complete all as specified and as directed by Engineer-in-Charge at site. (Make : NBC/SKF/SBBI)
Supply only capacitor with condenser spacer, ISI marked 230/240/250 volts AC 4 MFD suitable for exhaust fan complete all as specified and as directed by Engineer-in-Charge at site. Make : Havells Cat No 4 MFD/440V/PLWW/28X5 or equivalent .
S&F IN REPAIRS, switch piano, flush type, single pole, one way, 5 Amps, 230 volts, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, switch piano, flush type, 15 Amp, single pole, one way, complete all as specified and as directed by Engineer-in-Charge at site.
S&FIN REPAIRS, socket outlet, 3 pin, 2-in-1, 5 Amps, flush type, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, switch socket combination outlet, 2-in-1, 5 Amp, flush type, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, switch socket combination, multipurpose, 2 in 1, 3 pin, 5 & 15 Amp, flush type, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, socket outlet, 3 Pin 15 Amp, 240 volts, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, ceiling rose, surface bakelite, 65 x 50 mm, three terminal, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, lamp holder, insulated, PVC / Polycarbonate / bakelite body, with back plate, suitable for batten fitting or PVC round or square box, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, stepped type electronic fan regulator, flush type complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, fan capcitor 2.5 Mfd suitable for 1200/1400mm sweep ceiling fan complete all as specified and as directed by Engineer-in-Charge at site. Make-Havells Cat Part No: 2.25 MFD/440V/PLWW/28X52 or equivalent make
S&F IN REPAIRS, factory made, sheet steel distribution boards, TPN, 4 Way, double door, with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC 1:2:4, type B-1 using 20 mm graded stone aggregate complete all as specified and as directed by Engineer-in-Charge at site.
Supply & fix IN REPAIRS, MCB DB of sheet metal enclosure double door SPN 8 way with 200 A rated bus bar and grouted in wall with PCC 1:2:4, type B-1 using 20 mm graded stone aggregate complete all as specified and as directed by Engineer-in-Charge at site.
Supply fix IN REPAIRS, MCB DB of sheet metal enclosure, double door, SPN 4 way with 200 A rated bus bar and grouted in wall with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and as directed by Engineer-in-Charge at site.
Supply fix IN REPAIRS, MCCB DB, IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and as directed by Engineer-in-Charge at site. Make-Legrand cat No-5077 45 or equivalent in Siemens/Schnider/L&T NOTE FOR BOQ ITEM NOS 55 TO 58:- MCB's / MCCB's to be provided in DB's shall be measured and paid seperately under respective items in this Schedule.
S&F IN REPAIRS, MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA, C-series marked for fixing in DBs (DBs catered separately in this Schedule), complete all as specified and as directed by Engineer-in-Charge at site. Make :- Legrand/ Siemens/Schnider/L&T
S&F IN REPAIRS, MCBs, SPN, 32 Amps, In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA, C-series marked for fixing in DBs (DBs catered separately in this Schedule), complete all as specified and as directed by Engineer-in-Charge at site. Make :- Legrand / Siemens/Schnider/L&T
S&F IN REPAIRS, MCB Tripple pole & neutral 40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified and as directed by Engineer-in-Charge at site. Make :- Legrand / Siemens/Schnider.
S&F IN REPAIRS, for MCCBs 415 V, 16 KA, 4P, 63 Amps, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, for MCCBs 415 V, 16 KA, 4P, 100 Amps complete all as specified and as directed by Engineer-in-Charge at site.
Supply and fix IN REPAIRS, modular fan regulator,120 W, 2 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, modular switch 1 way 6 amp, 1 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, modular switch 1 way 16 amp, 1 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, modular switch 2 way 6 amp, 1 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, modular socket, 6 Amp 2/3 pin combined, 2 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, modular socket, 16 Amp 2/3 pin combined, 2 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, modular Bell push 6A, 1 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, modular white cover plate with frame, 1 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, modular white cover plate with frame, 2 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&FIN REPAIRS, modular white cover plate with frame, 3 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, modular white cover plate with frame, 4 module
S&FIN REPAIRS, modular white cover plate with frame, 6 module, complete all as specified and as directed by Engineer-in-Charge at site.
S&FIN REPAIRS, modular white cover plate with frame, 8 module
S&F IN REPAIRS, metal flush box 1/2 module for modular switches, complete all as specified and as directed by Engineer-in-Charge at site.
S&FIN REPAIRS, metal flush box 3 module for modular switches, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, metal flush box 4 module for modular switches, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, metal flush box 6 module for modular switches,complete all as specified and as directed by Engineer-in-Charge at site.
S&F BUV metal flush box 8 module for modular switches, complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, pre-wired casing caping / PVC conduit by changing DEFECTIVE, Casing caping /PVC conduit WITH NECESSARY FITTINGS, connecting items (such as flexiable conduit, screws etc) complete all as specified and as directed by Engineer-in-Charge at site.
Supply and fixing IN REPAIRS, LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge at site. Make : Havells Cat part No: PLANO2X2PLR36WLED840TPS or Equivalent in Phillips / Bajaj / Crompton .
S&F IN REPAIRS, 18 watt LED recessed/surface mounted luminaire with high brightness LED for glare-free homogenous illumination suitable for Armstrong/grid ceiling and fixture size in mm (LxWxH) 295x295x70 complete all as specified and as directed by Engineer-in-Charge at site. Make : Bajaj Cat No:BZRSQL18LWHODSD or equivalent model in make of Philips / Havells / Crompton
Supply and fixing IN REPAIRS, LED building security light of capacity 60 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection upto 10kV including connection with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmmX 3 core from light fitting to ceiling rose, complete all as specified and as directed by Engineer-in-Charge at site. Make : Surya Cat No:SLEUL60WIP66LXN or equivalent in Philips / Havells / Crompton / Bajaj
M&L for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed by Engineer-in-Charge at site.
S&F IN REPAIRS, LED 40/45 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and as directed by Engineer-in-Charge at site. Make -Bajaj cat no - BGCTN45LEDWW , or equivalent make.Havells/Phillips/ Crompton
S&F IN REPAIRS, LED surface/recess mounted round downlighter 12 W with pressure die-cast sink and PC difuser in chrome finish diffuser with integrated driver, complete all as specified and as directed by Engineer-in-Charge at site. Make- Bajaj cat Part No:830278 or equivalent in Havels/Phillips/Crompton
M&L for Disconnecting the main power supply to distribution board, re-alignment and re-connecting and proper dressing of SPN / TPN / VTPN MCB's / MCCB's / DBs of pre-connected MCBs by changing screw of DB cover, earth wire and other necessary connecting items and dressing of wires with the help of cable tie inside the distribution box including cleaning and doing all repair work including scraping and painting as required and alterations required to make the DB's fully operational complete and reconneting to main power supply after completion complete all as specified and as directed by Engineer-in-Charge at site. NOTE:- (i) Defective / unserviceable parts replaced will be paid separately under respective item of Sch 'A'. (ii) Labour element required for re-alignment and re-connecting and proper dressing of distribution board is included in the rate quoted for above item. (ii) Minor parts or accessories such as wires for connections, screws, tapes, lugs, locking arrangement, painting, welding / soldering / fabrication repairs to DB's is included in the rate quoted for above item. (iv) MCB's / MCCB's to be provided in DB's if required shall be measured and paid seperately under respective items in this Schedule.
PURBANCHAL BUILDERS (BID ID -3120593)
MAHINDER ELECTRICALS (BID ID -3122084)
RC Madan (BID ID -3122245)
M/s Dhruv Enterprises (BID ID -3121624)
M/s Gupta Construction (BID ID -3121466)
M/S DB TRADING CO (BID ID -3121178)
Sibson Constructions And Co (BID ID -3119891)
M/S UTTAM SAHA (BID ID -3120775)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .