Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.2 LAccepted-AOC | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹20.0 L+₹2.2 L (12.2%)Rejected-Finance | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹22.6 L+₹4.8 L (26.9%)Rejected-Finance | L-3 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
4 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jammu
GE Jammu c/o 56 APO Pin-180003
REPAIR / REPLACEMENT OF WATER RISING MAINS FROM TIPU LINE TO A GATE BOOSTER STATION AND MAINT OF MES INSTALLATION AND CONNECTED WORKS AT SUNJUWAN UNDER GE JAMMU
2021_MES_480687_1
GEJC-44/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹48,000
Yes
9 Dec 2021
8 Oct 2021
6 Nov 2021
8 Oct 2021
4 Nov 2021
22 Oct 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth (for taking up or laying of MS / CI / GI pipes) and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated surplus soils not exceeding 50 m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for road cutting, PCC hard standing with width 0.4 & depth 0.9 mtr including excavation for laying of GI pipe and making good the disturbed surfaces all as per existing surface complete all as specified and as directed.
M&L for welding / cutting work for MS pipe of dia 150 to 300 mm at leakage pipe and fixing the pipe with new pipe of existing dia of and welding the both side joints with required length of MS pipe to restore the water supply complete all as specified and as directed by Engr-in-Charge. Note :- Rates are deemed to be including hiring of T&P required at site.
Supply and fixing cast iron rising sluice valve both end flanged class PN 1.6 conforming to IS-14846-2000 with iron wheel head and brass spindle including necessary joint with nuts, bolt, washer, rubber or fiber board gasket, etc and testing complete all as specified and directed including taking down old one complete suitable for the following bore of pipes: -
150 mm bore complete all as specified and as directed.
200 mm bore complete all as specified and as directed.
250 mm bore complete all as specified and as directed.
Note: - Rates quoted by the contractor inclusive of necessary arrangement required for fixing of the item.
Supply and fixing cast iron non return valve both end flanged and fixed to the existing pipe line including joint with nut, bolt, washers, rubber or fiber board gasket, etc testing complete all as specified and directed including taking down old one complete suitable for the following bore of pipes: -
150 mm complete all as specified and as directed.
250 mm complete all as specified and as directed.
Supply and fixing cast iron foot valve flanged end and swing type operating with rubber seat as per IS-4038 fixed to UG sump pipe 150 mm dia including joint with necessary fittings as required at site, including taking down old one complete all as specified and as directed.
Supply and fixing cast iron double orifice air release valve ISI marked IS-14845 type DS2 in PN 1.0 flanged end with provision for inbuilt isolating valve to the existing pipe line including joint with necessary fittings as required at site, testing complete all as specified and as directed including taking down old one complete suitable for the following bore of pipes: -
50 mm dia complete all as specified and as directed.
100 mm dia complete all as specified and as directed.
150 mm dia complete all as specified and as directed.
Labour for repair / rectification of leakage of underground CI / DI pipe line of size 150 to 400 mm bore dia in position complete with excavation approximate 1.5 X 1.5 X 1.5 mtr around the leakage, returning, filling in, removal, cutting / dismantling of leakage complete with and including cocking to existing lead joint, filling new lead joint burning and taking out existing lead joint as per site requirement and restore the water supply complete all as specified and as directed. Note: Spare / fitting shall be measured and paid separately.
M&L for Run lead joint for CI spigot and socket pipes and fittings of dia 150 mm bore with new lead complete all as specified and directed.
M&L for Run lead joint for CI spigot and socket pipes and fittings of dia 200 to 250 mm bore with new lead complete all as specified and as directed.
M&L for Run lead joint for CI spigot and socket pipes and fittings of dia 300 mm bore with new lead complete all as specified and as directed.
Taking up CI / DI water mains (including all fittings) of dia 100 to 150 mm with spigot and socket ends and lead joints including burning out joints or flanged ends including disconnecting pipes and fittings complete all as specified and as directed by Engr-in-Charge.
Taking up CI / DI / MS water mains (including all fittings) of dia 250 to 300 mm with spigot and socket ends and lead joints including burning out joints or flanged ends including disconnecting pipes and fittings complete all as specified and as directed by Engr-in-Charge.
Supply and laying MS Black pipe P/E ISI marked conforming to IS-1239 PART - 1 (2004) of 150 mm dia bore medium grade ('B' Class) with flanged joints at both ends as per site requirement in trenches, on ground or on the support above ground level by continuous welding joints 15mm thick flange joint and testing complete, duly painted with two coats of bituminous paint externally all as specified and as directed by Engr-in-Charge.
Note: - (a) Rates quoted by the contractor inclusive of necessary arrangement required for fixing of the item. (b) Flange joint and flange jointing materials, welding etc shall be deemed to be included in the quoted rates of pipe. (c) During execution of work if any damage to civil building, internet cables, electric cables, electric poles, road, nallah, the contractor shall be fully responsible and repair to damage will be executed by contractor under own arrangements.
Supply and laying MS Black pipe P/E ISI marked conforming to IS-1239 PART - 1 (2004) of 300 mm dia bore, 5 mm thick with flanged joints at both ends as per site requirement in trenches, on ground or on the support above ground level by continuous welding joints 15mm thick flange joint and testing complete, duly painted with two coats of bituminous paint externally all as specified and as directed by Engr-in-Charge.
Note: - (a) Rates quoted by the contractor inclusive of necessary arrangement required for fixing of the item. (b) Flange joint and flange jointing materials, welding etc shall deemed to be included in the quoted rates of pipe. (c) During execution of work if any damage to civil building, internet cables, electric cables, electric poles, road, nallah, the contractor shall be fully responsible and repair to damage will be executed by contractor under own arrangements.
M&L for MS fititngs such as Bends (any type, radius and angles) bend to required shape by cutting and welding including flanges as required at site and testing complete including taking down old one all as specified and as directed for required size of bore 150 to 300 mm.
MS fittings shall be of same make as of MS pipes or of make as recommended by manufacturers.
The weight of the fittings shall be measured and paid as given in relevant IS or actually provided which ever is less.
All fittings shall bear relevant IS stamping marking.
Excavation and earth work shall be measured and paid for separately.
Cost of the joints and jointing materials shall be deemed to be included in the relevant items.
Supply and fixing CI / DI specials for spigot and socketed CI / DI pipes 150mm dia, such as bends (any type, radius and angle) Tapers any type (straight bends, increasing, decreasing or double socket etc) tee, pieces, single branches "Y" junction, double branches cross (all sockets or socket and spigot) collars, caps and plugs etc including taking down old one complete all as specified and as directed.
Supply and fixing CI / DI specials for spigot and socketed CI / DI pipes 150mm dia, such as connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged, other end tapering as bell mouth including taking down old one all as specified and directed by Engr-in-Charge.
Supply and fixing CI / DI specials for spigot and socketed CI / DI pipes 200 to 300 mm dia, such as bends (any type, radius and angle) Tapers, any type (straight bends, increasing, decreasing or double socket etc) tee, pieces, single branches "Y" junction, double branches cross (all sockets or socket and spigot) collars, caps and plugs etc including taking down old one complete all as specified and as directed.
Supply and fixing CI / DI specials for spigot and socketed CI / DI pipes 200 to 300 mm dia, such as connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged, other end tapering as bell mouth including taking down old one complete all as specified and directed by Engr-in-Charge.
Construction of brick masonary valve pit chamber of 1050 x 1050 x 1050 mm sizes (internal dimensions) with MS sheet cover 6 mm thick and angle iron 40 x 40 x 6 mm frame duly painted with two coats of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc including taking down old one complete all as specified and as directed.
Construction of brick masonary valve pit chamber of 900 x 900 x 900 mm sizes (internal dimensions) with MS sheet cover 6 mm thick and angle iron 40 x 40 x 6 mm frame duly painted with two coats of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc including taking down old one complete all as specified and as directed.
Construction of brick masonary valve pit chamber of 600 x 600 x 600 mm sizes (internal dimensions) with MS sheet cover 6 mm thick and angle iron 40 x 40 x 6 mm frame duly painted with two coats of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc including taking down old one complete all as specified and as directed.
M&L in replacement of GI Pipe light grade 80 mm bore for cable protection as a guard pipe complete all as specified and as directed.
M&L in replacement of GI Pipe light grade 50 mm bore for cable protection as a guard pipe complete all as specified and as directed.
M&L in replacment of GI Pipe light grade 40 mm bore for cable protection as a guard pipe complete all as specified and as directed.
Supply and laying well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable, adjacent / abutting each other complete all as specified and as directed by Engineer-in-charge in trenches over the cable for protection.
Supplying & Laying in ducts / trenches clear sand for cushioning underground cable 8 cm below and 15 cm above complete in level all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles and similar work including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard / dense soil at Two / Four pole structure at E/M installation inside the peripherry of installation and deposit removal materials 50 mtr away from the site all as specified and directed.
M&L for loose filling with aggregate of gauge 40mm broken stone and boulder deposited, spread, levelling in larger not exceeding 15 cm thick watered and ramming at E/M installation around 50 mtr of transformer all as specified and directed.
Taking down cement plaster of any description on bricks or stone walls or from concrete surface or from concrete surface and similar including racking out joints, hacking for key, scrubbing down with water and removing unserviceable material outside the cantt area all as specified and as directed by Engr-in-Charge.
M&L rendering 10 mm thick (average) in CM 1:4 on concrete surface / brick surface and similar including two or more dubbing coat, surface finished even and fair without using extra cement with necessary frame work, scaffolding for external surface complete all as specified and directed.
Taking out existing burnt / defective under ground XLPE cable of any size of 1100 volt grade from trenches / poles complete with protection pipe, sand cushioning, bricks etc for repair / rectification of fault and relaying the same cable in position after necessary repair / rectification of fault complete with relaying old bricks / sand, protection pipes etc and connection incuding testing all as per site requirement complete all as specified and as directed.
Repair / maintenance of existing burnt / defective UG XLPE cable 1100 volt grade cable of any size complete with charges for tracing out the fault, cutting / repair and jointing complete with using insulation tape, aluminium thimble, lugs, fitment of jointing kit, thimbles, necessary earth work complete all as specified and as directed. Note : Aluminium thimble, lugs, jointing kit, thimbles, earth work shall be measured and paid separately.
Supply and fix in replacement unserviceable aluminium lugs / thimble of size 300 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs / thimble of size 240 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs / thimble of size 185 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs / thimble of size 120 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs / thimble of size 70 / 95 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs / thimble of size 50 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs / thimble of size 35 sqmm complete all as specified and directed.
Supply and fix in replacement unserviceable aluminium lugs / thimble of size 25 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 25 to 95 sq mm complete all as specified and as directed.
M&L cable jointing kit for 11000 Volts grade (E) cable indoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 50 sqmm to 95 sqmm and jointing materials for making joints and testing complete all as specified and as directed.
M&L cable jointing kit for 11000 Volts grade (E) cable indoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 95 to 120 Sqmm and jointing materials for making joints and testing complete all as specified and as directed.
M&L cable jointing kit for 11000 Volts grade (E) cable outdoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 50 sqmm to 95 sqmm and jointing materials for making joints and testing complete all as specified and as directed.
M&L cable jointing kit for 11000 Volts grade (E) cable outdoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 95 to 120 Sqmm and jointing materials for making joints and testing complete all as specified and as directed.
S&F PVC fibre separator for LT line 1100 volt OH conductor 3 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete as specified and directed.
S&F PVC fibre separator for LT line 1100 volt OH conductor 4 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete as specified and directed.
S&F PVC fibre separator for LT line 1100 volt OH conductor 5 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete as specified and directed.
Labour for re-straining, tightening of existing swaged ACSR OH conductors spans of any size / type on HT / LT poles including necessary new aluminium binding wire for fixing with insulator / PVC sleeves for jumper etc as required complete all as specified and as directed. Note: - Pole to pole will be considered as one span of any length and no's of conductor.
Supply and fixing in replacement of ACSR conductor of any size and type from overhead HT / LT poles including binding at site to insulator with suitable size of binding wire etc including taking down existing worn out old broken ACSR conductor of any size and type and length at any position from LT / HT poles complete all as specified and as directed.
M&L in replacement of Galvanised steel wire 4.0 mm dia for continuous earth wire and cradles hexagonal / rectangular shall be provided and securely fastened to each pole and connected with earth ordinarily and cradle guarding where required complete including dismantling existing GI wire all as specified and directed.
M&L in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e. M.S. channel or angle sections etc. including new nuts, bolts, washers as required dia / length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide, one under coat and one finishing coat of silver paint (1st quality) as required complete all as specified and as directed.
Labour for cutting of tree branches 2 mtr vicinity of the conductor which are touching to the 11/9 mtr overhead lines in vertically and horizontally conductor and poles etc complete clear in a standard span in between two poles as per SSR Part-I, 19.59 and removing cutting material not exceeding 50 mtr and depositing where directed at a distance level not exceeding 3 mtr from starting point complete all as specified and as directed. Note: - Pole to pole will be considered as one span of any length and no's of conductor.
M&L for welding to damaged / broken hinges of unsv LT panel board shutters complete with painting and matching with existing colour complete all as specified and as directed. Note: - Welding of two no's of hinges shall be considered as one Job.
M&L for replacement of old unsv / broken shutter of LT panel with 3 mm thick CRCA sheet as per existing size to match with the existing panel duly powder coated and welding hinges and fixing complete all as specified and as directed by Engr-in-Charge.
M&L for painting of existing LT panel board with spray gun with synthetic enamel paint to match with the existing surface internally and externally including preparation of old rusted surface after taking proper shut down complete all as specified and directed by Engr-in-Charge.
M&L painting of transformer externally with two coats of spray painting with heat resistance / smoke grey heat resistance synthetic enamelled paint after cleaning rusted surface thoroughly with thinner and scrapper and preparing the surface to required standard including writing and marking such as MES No, SM No, Capacity, on the body of transformer capacity upto 400 KVA complete all as specified and as directed.
Material and labour for preparation of old painted / rusted surfaces of steel tubular poles 11/9 mtrs long type 410 SP-31, 55 and applying one coat of synthetic enamel paint upto 1.2 mtr height as per existing pattern above the PCC coping and two coats of aluminum paint (1st quality) beyond 1.2 mtr height (for the rest of portion) including cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles upto 1 mtr radius complete all as specified and directed.
Material and labour for preparation of old painted surfaces of PCC poles 11/9 mtrs long type 410 SP-31, 55 and applying two coats of synthetic enamel paint upto 1.2 mtr height in black (green) and white strip of width 30 cm each as per existing pattern above the PCC coping and two coats of aluminium paint to cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles upto 1 mtr radius complete all as specified and directed.
M&L for cleaning to overhead RCC reservoir of any capacity internally at approximate 40 feet high stagging by using water treatment chemical / bleaching powder / Sodium hypochloride chemical including cleaning internally entire wall surface, removing deposited particular, scrubbing complete wall surface and applying coat treatment water chemical on complete wall and drain out the water after disconnecting all rising / distribution sluice valves complete all as specified and directed.
M&L for cleaning to underground sump of any capacity internally at any height / stagging by using water treatment chemical / bleaching powder / Sodium hypochloride chemical including cleaning internally entire wall surface, removing deposited particular, scrubbing complete wall surface and applying coat treatment water chemical on complete wall and drain out the water after disconnecting all rising / distribution sluice valves complete all as specified and directed. Note: - Rate of labour to empty tank shall be deemed to be included in quoted rates.
Material and labour for providing two coats of synthetic enamelled base paint to external surface of MS sheet / rails / rising main / distribution pipe / wash out MS / CI pipe with suitable colour coding of overhead RCC reservoir at stagging approximate 22 mtr height all as specified and directed.
Material and labour for preparation of existing cement base plaster surfaces of upto 22 mtr height and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Material and labour for painting and writing letters "SAVE WATER" in Black letter size 36" X 18" on dome of overhead water RCC tank and UG sump, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 80 mm size on external surface of wall with white enamel paint over black background of any capacity overhead tank and UG sump all as specified and as directed Engr-in-Charge.
Supply and fixing in replacement of integral LED Aviation obstruction light 30 Watt (Set of 2) comprising of aluminium housing with polycarbonate enclosure with decorated Opal acrylic diffuser with IP-65/66 protection complete all as specified and as directed. Make: - Bajaj / C&S / Havells
S&F in replacement of Air termination single pointed aluminium rod 12 mm dia and 300mm long fixed with 40mm dia, 4 mtr long GI Pipe including providing flat iron clamps, nuts and bolts, embedding the GI pipe in PCC M-10 block (nominal mix) of size 30 x 30 x 40 cm and connecting complete all as specified directed by Engr-in-charge. Note: GI pipe and PCC will be measured and paid separately.
S&F in replacement of Aluminium strip 25 x 3.15 mm on overhead tank with saddle on minimum distance of 0.5 mtr through out the aluminium strip including nuts, bolts, washers, screws complete as indicated or directed by Engineer-in-Charge.
S&F in replacement of GI strip 32 x 6 mm as earth continuity conductor for loop earthing complete with fixing of saddles, nuts, bolts, washers, screws complete all as specified and directed.
M&L in replacement of Test point terminal block made of flat earth strip or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 no's 8 mm dia 25mm long hexagonal head screw complete all as specified and as directed.
Repair to replacement of old existing unserviceable mechanical water level indicator for overhead RCC reservoir / UG sump with replacement of GI pulley (02 No's), GI wire rope (as per site requirement), float valve of suitable size, painting of indicator, scales with black / red paints (radium type), marking on scales (as per site requirement) with all accessories and testing complete all as specified and directed.
Labour charges for repair / replacement of old / damaged MS sheet cover on valve pits 3.15 mm thick with handle and locking arrangement, angle iron frame 40mm x 40mm x 6mm (grouting with anchor fashioners length not less than 15cm - 04 No's) and painting with two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M&L for PCC Platform for outdoor transformer having capacity 400 KVA of size 3000 X 2500 X 1500 mm including providing 100 cm working space complete all around the transformer made out from sub class 'B' bricks complete with stair case and including filling morum / Bajari / stone aggregate, 63mm upto top edge inside the transformer platform complete all as specified shown on drawing and directed by Engr-in-Charge including considering the following: - (i) Transformer fencing of expanded wire mesh metal weight not less than 4 Kg/sq mtr cut to shape upto 1.20 mtr height complete with angle iron size 40 X 40 X 3mm thick fix at interval of 1 mtr each having length 1.2 mtr above the platform and 0.3 mtr inside the brick work, flat iron 20mm X 3mm thick for wire mesh complete with nut, bolt, washers and provn of entrance gate of suitable size as per site requirement complete with two coats of smoke grey part over a coat of red oxide primer. (ii) PCC 1:2:4 Class 'B' (using 20mm crushed stone aggregate) 80mm thick upto all around the transformer platform complete with excavation and earth work, returning, filling of soil and removal of surplus soil to a distance not exceeding 50m including filling of morum / bajari / stone against 63 mm thick below PCC all as directed by Engr-in-Charge.
M&L for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube floor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip of size 25 x 4mm by means of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with RCC cover in cement concrete 1:2:4 Type B-1 (using 20mm graded crushed stone aggregate), funnel, wire mesh, charcoal dust, salt layers each layer thickness should be 15 cm (layer start from below the electrode plate to above plate) etc, connected to LT panel board as indicated including testing complete all as specified and as directed.
Note: - (i) Rates are deemed to be included charges of hiring T&P, Veh, Ladders, steel shuttering or any equipment required at site for execution of work. (ii) Contractor shall be fully responsible for life insurance of the person deployed at site and get the repair under his supervision visitor from the qualified technician. (iii) Contractor will take the permission for shutting down the electric supply in writing for cutting tree branches, restretching etc.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
M/S Bali Agencies
Sarbat Construction Co
Bidder Name
Sarbat Construction Co
M/S Bali Agencies
vishesh engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .