Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹189.6 CrAccepted-AOC | ₹189.6 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹190.1 CrRejected-AOC | ₹190.1 Cr | L2 | Rejected-AOC Not being Lowest |
Tender Value
₹180 Cr
EMD Value
₹15 L
Closing Date
17 Aug 2019, 6:00 pmClosed
Chief Engineer AN Zone
Headquarters Chief Engineer AN Zone
PROVISION OF NEW HANGAR AT AF STATION CARNICOBAR
2018_MES_188466_4
801148E8
Open Tender
Civil Works
1095 days
CARNICOBAR
As per NIT
10 documents required · 10 mandatory
₹3,000
GE (I) 866 EWS
₹15 L
Yes
11 Feb 2020
20 Jul 2019
19 Aug 2019
20 Jul 2019
17 Aug 2019
3 Aug 2019
21 Jul 2019 - 27 Jul 2019
Amount
NOTE: Schedule ‘A’ Part I is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
SCHEDULE 'A' PART-I Analysis, design, detailing and supply of detailed Architectural & Structural drawings and Constn of Hangar bldg of PEB structure of size 100mx70mx 14m height including Annexes (Admin/Tech Accn) on both the sides of PEB Hangar in single/double storey (all dimensions as per Architectural drawings), all as specified and as under :- (i) Pre-Engineered Building Steel Structure for Hangar of size 100mx70mx14m (clear inner dimensions) placed in between two annexes on RCC foundation asper design (using RMC), anchor bolts, base plates and all structural steel items, rain water eaves-gutters and down take pipes, cable ducts, bird proofing of Aluminium alloy wire cloth net fixed with aluminium snap grid framework, etc., with electrically operated sliding doors (on both side of Hangar) with steel frame, etc., with Alu-Zinc colour coated profiled steel roofing sheets 0.5mm thick (TCT) of yield strength of 550 MPa in wall cladding and roofing (maximum of 15% roof/ wall sheeting with semi-transparent triple layer Polycarbonate sheets), excluding hangar flooring with PQC,DLC etc., but including epoxy flooring complete all as specified and as shown on drgs.
NOTE :- (a) Provision of necessary base plates including anchor bolts shall be deemed to be included in the unit rate. (b) Wall cladding on the building shall be provided as per drawings. Suitable eaves gutters and rainwater downtake pipes as required shall be provided to divert rain water from the Hangar Roof to ground level. (c) Provision of necessary arrangement for fixing bird proofing shall be deemed to be included in the unit rate. (d) The rate is deemed to include the cost of design, fabricate and erect electrically operated (with manual option) sliding Hangar doors-on both sides of Hangar. The rate is deemed to include the cost of providing one wicket door of size 1m x 2m in one leaf of hangar door. (e) The rate is deemed to include the cost of epoxy flooring 5mm thick (Epoxy Quartz 4mm thick plus top self levelling floor 1mm thick) in floor area of hangar. (f) Hangar flooring except Epoxy flooring shall be measured under respective item of BOQ.
(g) The EOT crane should be design and fabricated, test and commissioning in accordance with the latest editions of IS-807, IS-3177, other relevant standard referred to therein, the crane shall have the provisions of suspended type of capacity 5 Ton, 415 volts, 3 Phase 50 Hzs, 4 wire, solidly earthed system with 08 mtr hook height and 30 x 30m span travel with double girder type support (without any intermediate support on hangar flooring) alongwith all controls,power and control cable shall be clamped in groups separately. All trailing cables shall be clamped with PVC or non--metallic clamps. Make : M/s Safex energy Pvt Ltd, M/s Pioneer cranes & elevators Pvt Ltd, M/s Dinesh Enterprises. (h) Necessary foundation for hangar.
(ii) Construction of Annexes on both the sides of Hangar (Dimensions as per Architectural plan), in single/ double storied as permanent structure with RCC framed construction on RCC foundation (using RMC), complete all as specified and as shown on drgs.
Analysis, design, detailing and supply of detailed Architectural & Structural drawingsand constuction of Helicopter washing bay bldg (PEB structure) including Annexes (GSE & SV Parking) on both the sides of Helicopter Washing Bay in single storey as permanent structure with RCC framed construction based on permanent specifications on RCC foundation (using RMC), etc.,complete all as specified,as shown on drgs (all dimensions as per Architectural drawings), and as under :- .
(I) Pre-Engineered Building Steel Structure for Helicopter Washing Bay bldg of size 30x30x8m ht (Dimensions as per Architectural drawings) placed in between two annexes on RCC foundation asper design(using RMC), anchor bolts, base plates and all structural steel items, rain water eaves-gutters and down take pipes, cable ducts, bird proofing of Aluminium alloy wire cloth net fixed with aluminium snap grid framework, etc., with Alu-Zinc colour coated profiled steel roofing sheets 0.5mm thick (TCT) of yield strength of 550 MPa in wall cladding and roofing (maximum of 15% roof/ wall sheeting with semi-transparent triple layer Polycarbonate sheets, excluding hangar flooring with PQC,DLC etc., but including epoxy flooring complete (all dimensions as per Architectural drawings), all as specified and as shown on drgs including the provisions in Note here-in-below :-
(II) Construction of Annexes (GSE & SV Parking) on either side of Helicopter Washing Bay (all dimensions as per Architectural drawings), in single storey as permanent structure with RCC framed construction based on permanent specifications on RCC foundation (using RMC), etc., complete all as specified and as shown on drgs. in single/ double storied as permanent structure with RCC framed construction asper design on RCC foundation (using RMC), complete all as specified and as shown on drgs.
The rate includes the provisions of the following for BOQ sl No 2.00 to 2.20 & 3.00 to 3.20 here-in-before :- (i) The design has to be done by standard software of latest version. The rate shall deemed to include the cost of vetting of design of all structures (PEB Hangar, RCC foundations, Structural design of Annexes) by IITs/ IISC Bangalore. The design (showing full calculations & details) and drawings duly vetted by IITs/ IISc shall be submitted to the department as per time schedule communicated by the GE and as specified. (ii) The RCC structures should be designed as per IS.456-2000 and IS.1893-2002. Ductile detailing shall comply with provn as per IS.13920 and all relevant provns for seismic zone V area. (iii) Certificate from the vetting agency that the design is meeting all relevant codal requirements and design of building is structurally sound shall be furnished. (iv) All drawings for structural design, PEB structure including the details of expansion joints if any, details of structural members, junctions, structural plans, sections required for execution of works, etc., shall be furnished in original tracing alongwith soft copy in CD and 5 sets of hard copy.
GENERAL SUMMARY NOTE: Schedule ‘A’ Part - IA, II to XIX are prepriced by MES under Ser No. 5.00 to 22.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “BUILDINGS / STRUCTURES” as listed in Schedule ‘A’ Part - IA , inserted by MES
Lumpsum price worked out by the tenderer for "INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part- II
Lumpsum price worked out by the tenderer for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part- III
Lumpsum price worked out by the tenderer for "EXCAVATION & EARTH WORK INCLUDING SITE CLEARANCE AND LAND DEVELOPMENT " as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for " HELICOPTER WASHING BAY & GARRAGE APRON " as listed in Schedule ‘A’ Part- V
Lumpsum price worked out by the tenderer for " ROAD/ PCC HARD STANDING / CULVERTS " as listed in Schedule ‘A’ Part- VI
Lumpsum price worked out by the tenderer for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part- VII
Lumpsum price worked out by the tenderer for " AREA DRAINAGE" as listed in Schedule ‘A’ Part- VIII
Lumpsum price worked out by the tenderer for " EXTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part- IX
Lumpsum price worked out by the tenderer for " EXTERNAL ELECTRIFICATION " as listed in Schedule ‘A’ Part- X
Lumpsum price worked out by the tenderer for " LIGHTNING PROTECTION " as listed in Schedule ‘A’ Part- XI
Lumpsum price worked out by the tenderer for " DG SET " as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for " VOLTAGE STABILIZER " as listed in Schedule ‘A’ Part-XIII
Lumpsum price worked out by the tenderer for " HANGER / AVIATION / HIGH MAST/ DISPERSAL LIGHTINGS " as listed in Schedule ‘A’ Part- XIV
Lumpsum price worked out by the tenderer for " FIRE FIGHTING & FIRE DETECTION SYSTEM " as listed in Schedule ‘A’ Part- XV
Lumpsum price worked out by the tenderer for " AIR CIRCULATORS / COMPRESSORS " as listed in Schedule ‘A’ Part- XVI
Lumpsum price worked out by the tenderer for " LAN NET WORK " as listed in Schedule ‘A’ Part- XVII
Lumpsum price worked out by the tenderer for " SPECIAL PROVISIONS (B/R) " as listed in Schedule ‘A’ Part- XVIII
Subtotal
NOTE: Schedule ‘A’ Part - XIX " MICELLANIOUS ITEMS " is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
Site Clearance and land Development M & L for forming embankment using approved good earth obtained from out of Carnicobar island (with in India) (payment of royalty/ taxes, transportation to site by any means, etc) including raising earth, spreading in layers not exceeding 25cm thick, watering, ramming/rolling and finishing to required size shape etc.,to a compaction of soil under optimum moisture condition to achieve Standard Proctor Density not less than 98 % MPD and K-value at 3 Kg/cm2 /cm complete all as specified for a height of not exceeding 1.5m from base:-
All as per item srl No. 25 here-in-before but exceeding 1.5m and not exceeding 3m
All as per item srl No.25 here-in-before but exceeding 3m and not exceeding 4.5m Note for item serial Nos 25,26 &27:- (i) The source of good earth shall be got approved by GE before commencement of work. (ii) The good earth shall be tested as per frequency and other norms as specified in MoRTH for the purpose of forming embankment to achieve the desired compaction and got approved from GE before bringing the soil to site of work using in embankment.
Supplying and laying geo drain membrane of 8mm thick or 800GSM and sealed as in sub surface drain complete all as specified.
Supplying and providing of geo textile membrane of 220 GSM for increasing stability of gabions placement complete all as specified.
Supplying and laying of gabions stone in cages of engineered form, double twisted hexagonal woven steel wire mesh with gabions of size 2x1x1m and in English bond in staggered arrangement along the ground earth using wire mesh 2.7mm dia and nominal 3.4mm for edge selvedge wire with additional extruded U-PVC coating of nominal 0.5mm radial thick all as directed at the either ends of the hangar, rear/ front dispersal and helicopter washing shed complete all as specified.
M&L for 350mm thick pavement quality concrete work in pavement of flexural strength 45kg/sqcm (lower control limit) in field using min 400kg of cement/cum with 20mm nominal size of graded aggregate and super plasticiser if required as per design mix (as per IRC 5th revision) mixed with and including triangular/ non circular synthetic fibre reinforcement @ 0.25% by weight of cement with min 12mm length, specified gravity 1.34 to 1.40 (other specification as per IRC/MORTH) spread and compacted by using slip form paver and all as specified and including necessary form work, bull nosing, rounding of edges, finishing by mechanical brooming/ belting, curing, etc., complete all as specified.
M&L for Dry Lean Cement Concrete (DLC) of thickness 150mm with 7 days compressive strength of 10N/sqmm with min cement content(OPC 43 gde) of 240kg/cum or as per design mix whichever is more using grading as per MORTH specification, spread, rolled and consolidated to required camber and gradient using necessary mechanical sensor paver and tandem vibratory roller of capacity of exc.8 ton and n.exc.12 ton capacity complete all as specified. Note: (i) No price adjustment shall be applicable if excess quantity of cement content is used / approved based on mix design in the execution of work under this item. (ii) Aggregates used in the work shall be obtained from approved source of main land (India) as approved by GE.
M&L for Wet Mix Macadam 225mm thick (compacted thickness in three layers of 75mm each with coarse aggregate of specified grade as per MORTH, spread, rolled and consolidated to required gradient and camber complete using mechanical paver/ grader and tandem vibratory roller/ earth compactor of capacity exc.8 ton and n.exc.15 ton at OMC to achieve the min 98% density to MDD determined using compactor density determination method as per IS Code all as specified. Note: (i) Rate inserted in this item is for 225mm thick (Consolidated thick) in three layers (ii) WMM shall be as specified in MoRTH specification Orange book (Fifth revision). (iii) Soaked CBR value for the top surface of the WMM should to achieve minimum 15 to 20 in field. (iv) Aggregate used in the work shall be obtained from approved source of main land (India). (v) Anti weed growth measures in terms of chemical spray shall be adopted during monsoon season if work stopped for bad / wet weather conditions.
M&L for 200mm (compacted thickness) granulated sub base (GSB) of grading-V (as per 5 th revision MORTH) in single layer, surface formed, rolled and consolidated to required gradient and camber using earth compactor of min 8 ton to15 ton or compaction at OMC to achieve the min 98% density of MDD determined using proctor density determination method as per IS code to achieve min CBR value 5 to 6% all as specified. Note: (i) Rate shall be quoted for 200mm thick (Consolidated thick) in single layer. (ii) Compaction of GSB shall be carried out under optimum moisture conditions to achieve 98% of modified proctor density. (iii) Material for Granular sub base (GSB) used in the work shall be obtained from approved source of main land (India). (iv) Anti weed growth measures in terms of chemical spray shall be adopted during monsoon season if work stopped for bad / wet weather conditions.
M&L for laying 400micron HDPE sheet over tack coat of 2.5kg/ 10sqm of VG-10 HDPE with 400 micron manufactured by multilayer technology using 100% virgin row material, confirming to IS:10889:2004 with company logo and IS Code and Batch number on at least every 2 meters complete all as specified. Note : Manufacturer's test certificates for every consignment shall be mandatory.
HANGAR & DISPERSAL / HELICOPTER WASHING BAY FLOORING M&L for forming 25mm wide expansion joint filled with compressible synthetic filler board for complete depth of joint, i.e. the thickness of slab, provision of closed shall back up rod 30mm dia, filled with polyurethane sealant (min depth of sealant above back up rod shall be of 15mm), complying with BS 5212, BS 4254, and EN 41875-2003, priming the sides min MAF ± 30% with 10 years performance guarantee and applying masking tape on edge of joints to prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical applied all as shown on drawing and all as specified.
M&L for forming construction joints 25mm deep and 10mm wide (using diamond cutter) providing polythene back up rod 12mm dia and sealed with polyurethane sealant (min depth of sealant 12mm), complying with BS 5212, BS 4254, and EN 41875-2003, priming the sides min MAF ± 30% with 10 years performance guarantee and applying masking tape on edge of joints to prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical applied all as shown on drawing and all as specified.
M&L for forming dummy joint 1/3 depth of slab and 8mm wide (using diamond cutter ) providing polythene back up rod 10mm dia and sealed with polyurethane sealant (min depth of sealant 12mm), complying with BS 5212, BS 4254, and EN 41875-2003, priming the sides min MAF ± 30% with 10 years performance guarantee and applying masking tape on edge of joints to prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical applied all as shown on drawing and all as specified.
ROAD/PCC HARD STANDING/CULVERTS M&L for retro reflecting boards made up of 2mm aluminium sheet face to be fully covered with high intensity prismatic A (Type-IV) sheeting confirming to type III of ASTM-D-4956-01 as approved by Engineer-in-charge. Letters, borders etc as per IRC : 67-2001 in silver white with blue/green colour background and with high intensity grade, pasted on substate by pressure sensite adhesive backing which shall be activate by applying pressure confirming to class II ASTM -D-1956-01 & fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts and nuts including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coats, fixing & erecting in all position all complete as per drawings and all as specified.
S&F retro reflective high intensity prismatic (IV) sheeting (w/o aluminium sheet) confirming to Type-III of ASTM-D-4956-01 as approved by Engineer-in-charge, Letters, Borders, etc., as per IRC : 67-2001 in silver white with blue/green colour background and with high intensity grade, pasted on substate by pressure sensite adhesive backing which shall be activate by applying pressure confirming to class II ASTM-D 1956-01 & fixing the same on the other side of existing sign boards placed vide Item No (v) above complete all as specified.
INTERNAL ELECTRIFICATION: Supply & Fix LED lamp (bulb) base B12 (holder type) 9 watts complete all as directed.
S&F Rotary type dimmer 500 watt for focus light complete all as specified and as directed. Make: Cat Part No CS20801 of C&S or equivalent in Havells/Anchor
Supply and fix ceiling fan, 5 star rating suitable for working on AC 230V,50 Hz, 1400MM sweep with down rod and canopy rating and the colour of milky white including anchor fastener, ceiling hook for fixing of fan on ceiling or on steel structure complete all as specified and directed by engineer-in-charge. Make:- Crompton Cat No-Entrust-50 or equivalent make in Bajaj/Philips/Orient
Supply and Fixing ISI marked Exhaust fan heavy duty type with double ball bearing, continuous rated along with GI louvers for protection when not in use, silent operation, rust proof body and blades, MS grate for rodent protection with fixing arrangements of size 300mm sweep, 1400 rpm and connecting up including provision of three core flexible PVC cable with stranded copper conductor of size 0.75 Sqmm 3 core from ceiling rose to connector of exhaust fan all as directed and as specified. Make: Crompton Cat No-EXHD300 or equivalent make Orient/Havells
Supply and Fixing ISI marked Wall mounted fan heavy duty along with fixing arrangements of size 450mm sweep, 1200 rpm and connecting up complete all as directed and as specified. Make: Crompton Cat No- Hiflo LG 18", or equivalent make in Orient/Havells
S&F LED type security light fitting 1x36watts pressure die cast housing with aerodynamically shaped body, high grade powder coating finish, good aesthetics, corrosive protection, toughened glass & high power LEDs protection, lumen output 1650lm, CRI-70, power factor >0.9 including mounting arrangements like bracket made out of galvanized iron tubing 'light grades' of suitable dia of pipe up to a length of 1.5m bent to shape fixed to wall with mild steel flat iron clamps 40x5mm duly painted and connecting with 1.5 Sqmm three core weather proof PVC cable copper conductor multistranded from terminal point to fitting complete all as specified and directed. Make : Phillips Cat No: BRP409 LED CW 036 MR FG S1PSU GR or Equivalent in Wipro, Bajaj, Osram Note : After completion of the work contractor shall submit a written guarantee for a period of life time 50,000 burning hours as per manufacturer instruction.
Supply and Fix LED tube light fittings 4 feet long 1x 20 W 230V smart bright, energy efficient tube light, power factor >0.9 complete & prewired for LED tube complete fixed to wall / Ceiling by suitable, PVC round blocks and connection by flexible PVC cable with stranded copper conductor from ceiling rose to connector of the fitting including 1x20W LED tube complete all as specified. Make: Philips Cat No-BN021C LED 20S-6500 PSU CDL GR or Equivalent in C&S/CG/ Bajaj
Supply and Fix LED tube light fittings 2 feet long 1x 10 W 230V smart bright, energy efficient tube light, power factor >0.9 complete & prewired for LED tube complete fixed to wall / Ceiling by suitable, PVC round blocks and connection by flexible PVC cable with stranded copper conductor from ceiling rose to connector of the fitting including 1x10W LED tube complete all as specified. Make: Philips Cat No-BN021C LED 10S-6500 PSU GRS1 or Equivalent make in C&S/CG/ Bajaj
Supply and fixing Eco accent delivers powerful , good quality accent lighting enabling retailers to display their goods suitable for wall/ceiling mounted of capacity 20 watt complete all as specified and as directed. Make : Cat Part No ST271T LED20/840 PSU-E WB 1C BK of Philips or equivalent make in C&S/CG
Supply and fix 20 watt cirrus mini pro energy saving surface mounted decorative LED luminaire with inbuilt driver unit including necessary connection and fixing arrangement all as specified and as directed. Make : Philips Cat Part No SM20OC LED 16S 6500 PSU OD WH or equivalent make in Bajaj/CG
Supply and fixing smart Glow is an intelligent office lighting system with an inbuilt sensor and driver of capacity 36 watt LED suitable for recess/ceiling mounted complete all as specified and as directed. Make : Philips Cat Part No RC 383B LED 36S-6500 PSU OD WH PIR or equivalent make in C&S/CG/Bajaj
Supply and fix vertical TPN DB with MCCB incomer conforming as per IS 8623, IEC 61439-1&3 Sheet steel factory made double door, powder coated and bus bar 200 Amps copper busbar fully insulated busbar IP 54 ,Neutral link, Earth bar, double door type TPN 8 Way 415Volt, suitable for MCCB 250 Amps as a Incomer complete all as directed. Make : L&T Cat No -DBVTH008DD or equivalent make in L&T / Schneider / ABB
Supply and fix vertical TPN DB with MCCB incomer conforming as per IS 8623, IEC 61439-1&3 Sheet steel factory made double door, powder coated and bus bar 200 Amps copper busbar fully insulated busbar IP 54 ,Neutral link, Earth bar, double door type TPN 4 Way 415Volt, suitable for MCCB 125 Amps as a Incomer complete all as directed. Make : L&T Cat No DBVTL004DD or equivalent make in L&T / Schneider / ABB
Supply and fix MCB TP 63 Amp capacity 415 Volt 50Hz 10 KA 'C' Curve
Supply and fix MCB TP 40 Amp capacity 415 Volt 50Hz 10 KA 'C' Curve
Supply and fix MCB Four pole 63 Amp Capacity 415 volt 50 Hz 10 KA 'C' Curve
Supply and fix MCB Four pole 32Amp Capacity 415 volt 50 Hz 10 KA 'C' Curve
Supply and fix MCB Double pole 40Amp Capacity 230 volt 50 Hz 10 KA 'C' Curve
Supply and fix MCB Double pole 32Amp Capacity 230 volt 50 Hz 10 KA 'C' Curve
Supply and fix MCB single pole 40 to 63Amp Capacity 230 volt 50 Hz 10 KA 'C' Curve
Supply and fix MCB single pole 6 to 32Amp Capacity 230 volt 50 Hz 10 KA 'C' Curve
S& F four pole MCCB thermal magnetic type 250 Amps capacity 36 ka 415 Volt four pole including fixing arrangement type all as directed. Make :-L&T Cat No-CM98065OOPO or equivalent make in L&T, Schneider / ABB
S& F four pole MCCB thermal magnetic type 160 Amps capacity 25 ka 415 Volt four pole including fixing arrangement type all as directed. Make :- L&T Cat No-CM90631OONO or equivalent in Schneider / ABB
S& F four pole MCCB thermal magnetic type 125 Amps capacity 25 ka 415 Volt four pole including fixing arrangement type all as directed. Make :- L&T Cat No-CM90631OOMO or equivalent in Schneider / ABB
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth wire 4mm dia connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point
LIGHTNING PROTECTION AND EXTERNAL ELECTRIFICATION Earthing complete with Galvanised steel earth plate electrode of size 60x 60cm x 6mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal GL connected to GI strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers and earth strip protected by 40mm dia GI pipe medium grade connected to main distribution board/ earthing test point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1;3;6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways, GI funnel with watering pipe, wire mesh, salt and charcoal, protection pipe for earth lead upto 7.50m long complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified in SSR part-II earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
DG SET Supply, install, testing and commissioning of approved OEM factory assembled diesel generator set of totally enclosed and sound proof (with acoustic enclosure) of capacity 500 KVA, 3 phase, 4 wire, 415 volts,1500 RPM, AC power supply with power factor 0.8, coupled directly to alternator mounted on common base plate complete with fuel tank, battery maintenance free 12 Volt 180 AH and standard accessories and fittings, vibration pads, necessary foundation and spares as per manufacturer instructions complete all as specified and as directed. The genset shall confirm to CPCB norms for noise and emission limits and including the followings OEMs : Kirloskar (KOEL), Cummins,Greaves Cotton,Perkins.
(a) Alternator :- Standard design Alternator 500 KVA net output at site after considering all derating factors, side conditions ,self regulated, Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1, IP 23, alternator rated for 400 KW/ 500 KVA at the speed of 1500 RPM at 415 volt/440 volts, 50 Hz +/- 3% tolerance, 3 phase, 4 wire system,PF 0.8 with advance electronic voltage regulator/to ensure ±1% with class H class insulation 3 phase reconnectable winding with 12 terminals brought out for connection, compact design with sealed bearings for longer life and lesser maintenance, and directly coupled with engine flexible / Fix coupling complete (Make of Alternator :- Stamford / Cater piller/ KOEL / Perkins (b) Diesel Engine :- Adequate capacity diesel engine suitable to 500 KVA alternator, water cooled, to drive independently above alternator and after considering derating as per site conditions supplying power to multicyclinder, multistroke, direct injection, cold starting, 1500 RPM, as per relevant ISO 8528 applicable for supplying power to varying electrical load for unlimited hours. with an overload cap 10% for 1 hour in any 12 hours continuous running complete. with standard accessories all as specified and required for safe running and operation. salient features of accessories shall be as under :- Kirloskar (KOEL), Cummins,Greaves Cotton,Perkins.
(i) Fully electronic control engine With KG 934 relay or higher version. (ii) Well designed air handling system with (a) Dry type, replaceable paper element air cleaner with restriction indicator. (b) Air to air after cooling. (c) Optimized turbocharger for increased altitude capabilities. (iii) best in class fuel economy (a) Modular Common Rail (MCRS) fuel system with A1 class electronic governing. (b) dual fuel filter system : pre filter including water separated and water in fuel (WIF) sensor and main filter. (iv) Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperatures. (v) Ventury combo spin on lube oil cleaner (vi) Hand mounted SS oil filters (vii) First fill of lub oil and coolant (viii) Suitable coupling and guard (ix) Fly wheel with staring ring (x) Fuel and lubricant oil filter (xi) Water pump
(c) Engine control Panel The control system is a microprocessor based relay of KG 934 or higher version for generator set monitoring, metering and control system with LCD display having monitor the parameters KW,KVA, Current ,Voltage phase to phase and phase to neutral HRS Run, PF, No of strats, fuel level, safety parameters water temperature, oil temperature, low fuel level, high speed, low speed, all as directed. (i) AVR for shunt or PMG excitation with torque matching. (ii) electronic governing with temperature compensation and smart starting with control unit (iii) Engine Metering: Oil pressure, temperature, Starting battery voltage, Engine running speed. (iv) AC Alternator Metering: L-L Voltage and L-N Voltage, Current (1 and 3 phase), Volt meter (phase and total) and Frequency. (v) Engine Protection: Low lube oil pressure, High/Low coolant temperature, Over Speed, Battery Over/Under Volts, Fail to Crank / Start, Sensor failure. (vi) AC Alternator Protection: Over/Under Voltage, Over/Under Frequency, Over current, short circuit and loss of AC sensing. (vii) Data Logging: Engine Hours, Control Hours, engine starts upto 10 recent fault codes. (xiii) 24 volt DC operation (ix) Sleep mode (x) Certifications - meets the requirement of relevant UL,NFPA,ISO,IEC, Mil Std. and CE and CSA standards.
(d) Common Base frame :- Common fabricated base frame for engine and alternator made from structure channel of I section or angle iron etc duly installed on the suitable leak proof PCC foundation (1:2:4) type B-1 including adequate number of suitable anti vibration pads and PCC Foundation all as per the recommendation of the manufacture. (Rate of PCC foundation will be measured separately) f) Acoustic Enclosure : (i) Specially designed to meet stringent MoEff/CPCB norms of 75 dBA@ 1 mtr at 755 load under free field conditions. (ii) The acoustic enclosure is made of CRCA sheets in munsel green shade and a structural/sheet metal base frame painted in black. (iii) Silencer shall be provided with aluminium cladding with glass wool up to the exhaust pipe.
(e) Common Base frame :- Common fabricated base frame for engine and alternator made from structure channel of I section or angle iron etc duly installed on the suitable leak proof PCC foundation (1:2:4) type B-1 including adequate number of suitable anti vibration pads and PCC Foundation all as per the recommendation of the manufacture. (Rate of PCC foundation will be measured separately) (f) Acoustic Enclosure : (i) Specially designed to meet stringent MoEff/CPCB norms of 75 dBA@ 1 mtr at 755 load under free field conditions. (ii) The acoustic enclosure is made of CRCA sheets in munsel green shade and a structural/sheet metal base frame painted in black. (iii) Silencer shall be provided with aluminium cladding with glass wool up to the exhaust pipe.
(iv) High quality noise absorbent and fire-retardant grade acoustic insulation material (PU foam) complying to Is 8183. (v) Base lifting for easy handling. (vi) Designed to have optimum serviceability. (vii) Air Inlet louvers special purpose CNC machines for consistency in quality and workmanship. (viii) 11 tank pre-treatment process and UV resistant powder coating of all parts to withstand extreme environment. (ix) Use of special hardware for longer life. (x) Fluid drains for lube oil and fuel. (xi) fuel filling arrangement inside the enclosure (g) Fuel tank: DG set should have built in fuel tank made out from 3mm thick MS sheet and fuel gauge of adequate capacity running for 12 hrs and suitable for diesel tank cleaning with analog gauge with fuel level sensor all as directed
Earthing complete with copper earth plate electrode of size 60x 60cm x 3.15 mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal GL connected to copper strip 20 mm x 3 mm by means of bolts, nuts, check nuts and washers and earth strip protected by 40mm dia GI pipe medium grade connected to main distribution board/ earthing test point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1;3;6 mix, TypeC1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways , GI funnel with watering pipe, wire mesh, salt and charcoal, protection pipe for earth lead upto 7.50m long complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified in SSR part-II earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
Supply, testing and commissioning weather and vermin proof AMF.Panel board off size 1.3 x1.3 x 0.50 mtr factory fabricated indoor cubicle type totally enclosed made out of 2.00 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent moisture/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly with painted one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour and bus bar for 3 phase & neutral of 1200 Amps capacity mounted on epoxy insulator-01 Set including connecting the following:- (i) 4 pole contactor MCX 800 Amps (MCX 47) with two nos NO/NC contacts - 2 Nos (ii) AMF control relay with standard functions (iii) AC power monitoring contactors with NO/NC - 2 Nos
(iv) Timers -2 Nos (v) DC contactors with NO/NC - 2 Nos (vi) Control circuit fuses - 1 set (vii) Multifunction meter - 1 Nos (V,I,PF,KW,KVA,functions) (vii) Emergency stop push switch - 1 Nos (viii) DG on , Load on Mains/DG, fail to start, RYB LED indication lamps - 1 set (ix) UV/OV relay -01 Nos
HANGAR LIGHTING S&F Industrial vertical LED 120W high bay luminaire with reflector comprising of heat sink, clear glass, gear tray, canopy, IP66 with all standard accessories including necessary LED lamp of 120W and fixed to pre engineered steel structures using mild steel clamps bent to shape, bolts, nuts and washers, connecting up with PVC insulated multistranded 3 core cable all as specified and directed. Make: Philips Cat Part No. BY325P LED 155 SCW PSE FG or equivalent in HAVELLS/ CROMPTON/ BAJAJ Note :- The tenderer shall submit hangar lightning design as per DIAlux software to the Accepting Officer for obtaining approval of make prior to incorporation in the work.
Supply and fix vertical TPN DB with MCCB incomer conforming as per IS 8623, IEC 61439-1&3 sheet steel factory made double door, powder coated and bus bar 200 Amps copper bus bar fully insulated bus bar IP 54, Neutral link, Earth bar, type TPN 6 way 415 volt, suitable for MCCB 160 Amps as a incomer complete all as directed. Make:- L&T Cat No DBVT006DD or equivalent make in L&T / Schneider / ABB
Supply & Fix MCB single pole 240 volts, 10 to 32 amps for Hanger light, 10 KA complete all as specified and as directed.
Supply & Fix MCB triple pole 240 volts, 63 amps for Hanger complete all as specified and as directed..
Supply & Fix MCB triple pole & neutral 240 volts, 40 amps for Hanger complete all as specified and as directed.
Supply and fix MCCB 160 Amps 25 KA 4 pole G frame complete all as specified and as directed.
AVIATION LIGHTING S & F Aviation obstruction light fitting, die cast aluminium alloy housing built in electronic driver unit , heat resistant, clear thick glass and connecting up complete with all accessories as specified and directed. Make: Bajaj product code 110731 BGAV 302 LED or Equivalent in C&S/CG/ Luker
Supply and fix MCB SPN 6 to 32 amps complete all as specified and as directed.
HIGH MAST & DISPERSAL LIGHTING Supply and Fix LED Flood light fitting 80 watts internally pre wired with electronic driver unit comprises of a versatile pressure die cast aluminium housing with secondary optics heat silk with IP 66 protection, mounted on hanger for dispersal with fixing arrangement such as MS clamps, nuts, bolts complete all as specified and as directed. Make: Cat No BARFEG 80 W LED of Bajaj or Equivalent in C&S/CG/ Luker/Havells
SOLAR LIGHTING Supply & installation of solar power system for IBEAM LED SSL 20 watts ,TS 60 x 2 , with 4 mtr pole , solar module 60 watts power 2 nos and 1 nos 20 watts LED light fitting including tubular battery 12 volts 100 AH with battery box including necessary foundation of pole as per manufacture recommendation all as directed. Make: Bajaj Model - BRP420 or equivalent in Crompton/Havells/Philips
Supply and install GI flanged foot valve with internal leather washer onforming to IS 4038 complete of size 150 mm dia bore all as directed.
Supply, installation, testing and commissioning of 2 x 0.75 sqmm multi stranded Copper cable for fire detectors system all as directed.
AIR CIRCULATOR (VENTILATION) Supply and fix Air circulator fan 600 mm sweep suitable for single phase AC 230 Volts 50 HZ complete including mounting arrangement all as directed (to be mounted on prefab steel structure) Make:- Bajaj/Crompton/Havells
Supply and fix MCB SP 6-32 amps including connecting up complete all as directed
Supply and fix MCB SPN 32 amps including connecting up complete all as directed
AIR COMPRESSOR Supply, Install and Commissioning of air compressor, two stage, reciprocating type , twin cylinder system, air cooled, oil cooled, oil splash lubricating, maximum working pressure of 12 kg/cm² (175 psi) free air delivery i.e. discharge of 20.5 (580 Ltrs/min) (piston displacement of 24.7 CFM mounted on tank of capacity 220 ltrs driven by 7.5 HP, 3 phase. 415 volts, 50 Hz electric driven motor with DOL starter, suction, filter, aluminium finned intercooler and outer cooler, pressure switch, pressure guage, safety valves, V-belts, belt guard, non return valve and air compressor should be trolley mounted. Make : ELGI model No. TS 07 120 HN or equivalent including necessary foundation for compressor as per manufacture recommendation
Supply and fix of flexible hose of 20 mtrs length suitable for above item for pneumatic power tools including suitable nozzle gun made up of brass metal with all connected accessories complete all as specified and directed.
Supply and lay LT XLPE insulated multi stranded copper conductor un armoured cable of size 3 core 6 sq mm (from panel to compressor connection)
Supply & Fix Helicopter washing plant, reciprocating type, electric driven, single phase, 230 V, AC supply complete with High pressure Triplex pump, and 3 HP single phase motor, including starter, high pressure delivery hose and brass hand gun with PCC platform for pump set complete all as specified and directed .
EXTERNAL WATER SUPPLY M&L for cutting of existing GI / CI pipe line of size 80 mm for insertion of tee 100x100x80mm and tail piece and jointing material complete all as specified
S&F Sluice valve 80 mm dia with iron wheel head, stain steel stem gun metal gate class PN 1.0 as per IS 14846 including connection , testing all as directed.
EXTERNAL ELECTRIC SUPPLY Supply, testing and commissioning weather and vermin proof L.T.Panel board factory fabricated indoor cubicle type of size 2.4 x 2 x 0.9 mtr totally enclosed made out of 2.00 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly with painted one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour and bus bar for 3 phase 1200 Amps & neutral of 800 Amps capacity mounted on epoxy insulator including connecting the following.
(i) Incoming ACB 4 pole, 415 Volts with thermal magnetic release ( Manual fixed type ) of capacity 800 Amps (ii) Outgoing 250 Amps, 3pole MCCB, 36 KA - 02No ( AC Plant & APFC Panel) (iii) Outgoing 250 Amps, 3 pole MCCB, 25 KA - 01 Nos ( Fire panel) (iv) Outgoing 125 Amps, 3 pole MCCB, 25 KA -02 Nos (Annexure LH & RH) (v) Outgoing 250 Amps, 3 pole MCCB, 25 KA -02 No (Annexure LH & RH) (vi) Outgoing 32 Amps , 3 Pole MCCB, 16 KA -04 Nos ( Crane, air compressor, Hanger door) (vii) Multi function Meter-1 No. (viii) Timer switch, 20 Amps -1 No (ix) LED Phase indicator lamps(RYB) - 1 set
Supply, testing and commissioning weather and vermin proof L.T.Panel board factory fabricated indoor cubicle type of size 1.8 x1.5 x0.45 mtr totally enclosed made out of 2.00 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly with painted one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour and bus bar for 3 phase 600 and neutral of 400 Amps capacity mounted on epoxy insulator including connecting the following.
(i) Incoming 250 Amp, 3 Phase, 4 pole MCCB, 25 KA-01 No (ii) Outgoing 100 Amps, 3pole MCCB, 25 KA - 03No (Compressor/Chiller) (iii) Outgoing 100 Amps, 3 pole MCCB, 25 KA - 02 Nos (Pumps) (iv) Outgoing 32 Amps, 3 pole MCCB, 25 KA -02 Nos (Cooling tower) (v) Multi function meter-01 Nos (vi) LED phase indicator lamps (RYB)-01 Set
Supply, testing and commissioning weather and vermin proof L.T Panel board factory fabricated indoor cubicle type of size 1.2 x 1.5 x 0.45 mtr totally enclosed made out of 2.00 mm thick sheet metal enclosure with angle iron frame of M.S angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly with painted one coat of red oxide primer and two coats of synthetic enamel paint of grey or any other approved colour and bus bar for 3 phase 600 Amps & neutral of 400 Amps capacity mounted on epoxy insulator including connecting the following.
(i) Incoming 200 Amp, 3 Phase, 3 pole MCCB, 25 KA-01 (ii) Outgoing 125 Amps, 3pole MCCB, 25 KA - 02No (Annex, Power Sockets) (iii) Outgoing 100 Amps, 3 pole MCCB, 25 KA - 03 Nos (Hanger lights, washing bay and spare) (iv) Outgoing 40 Amps, 3 pole MCCB, 25 KA -02 Nos (Hangar light, dispersal light) (v) Multi function meter-01 Nos (vi) Timer Switch, 20 Amp-01 Nos (vii) LED phase indicator lamps (RYB)-01 Set
S&F LED type street light fitting 1x25W, pressure die cast aluminium housing with heat resistant toughened glass & IP65 protection including mounting arrangements like light grade GI pipe bracket of suitable dia. of length not less than 1.5m, bent to shape and fixed on poles / wall with two no. of MS flat clamps etc. duly painted with two coats of aluminium paint over one coat of zinc chrome primer , including wiring from light fitting to junction box complete all as specified and directed.
S & F sheet moulding compound (SMC) type junction / looping box for street light fitting with hinged type door of size 139x119x70 mm (internal) with MCB SP 6 Amps 01 No, backlite base neutral link and earthing along with suitable size of bus bar.
Supply , erect and fixing pre-cast RCC pole , M-30 design mix 9m long having 150mm x 125mm at top and 350mm x 250 mm at bottom including reinforcement with high strength deformed steel TMT bars and necessary form work and erecting in position all as specified /shown on drawing and as directed. NOTE :- (i) RCC pole 9mm long shall be provided all as shown on TD drawing No TD 401 sheet 1/1 dt 11.09.06 (ii)The rate quoted deemed to include the following provisions also :- (a) Excavation in any type of soil, returning, filling and removal of surplus soil to a distance of 50m. (b) Foundation in PCC (1:2:4) type D2 using 40mm graded stone aggregate. (c) Coping in PCC (1:3:6) type C1 using 20mm graded stone aggregate.
Supply, install, testing & commissioning of 20 KVA on line UPS system consisting 12 pulse rectifier, inbuilt iso lation transformer & suitable for input of 300 to 450 V, AC, 50 Hz, 3 ph,4 wire & three phase output, AC 415 volts ± 1% line to line, 50Hz, 3 ph, 4 wire,along with batteries for 1 hour back up air cooled encloser protection class IP-21, free standing cabinet with front and rear access, ambient operating temperature 0°C -45°C and including connection of suitable size of copper conductor cable all as specified and directed. Make. Microtek or equivalent model of Luminous / Su-Kam/Aplab
HELICOPTER WASHING PLANT Supply, installation, commissioning and testing of RO Plant 500 Ltrs/hour capacity including Distilled water plant of 250 Ltrs/hour capacity with water Demineralisation (DM) with Electro-Deionization (EDI) to provide helicopter washing and treated water less than 15 ppm including inlet/outlet connection from tank of required size and PCC foundation platform for the plant and tank all as per manufacturer's instruction / drawing and all as directed.
Supply and fix MCB Triple pole 32 Amps complete all as specified and as directed
Supply and fix RCBO four pole 63 Amps complete all as specified and as directed
Supply and fix RCBO four pole 40 Amps complete all as specified and as directed
Supply and install GI flanged foot valve with internal leather washer conforming to IS 4038 complete of size 100 mm dia bore all as directed
Supply and fix pressure gauge 100 mm dia suitable for upto 20 Kg per cm2 pressure suitable for fixing on 15 mm GI pipe (Pneumatic line) complete all as specified and as directed
Supply and fix ball valve / butterfly valve suitable for pneumatic line one side threaded and one side nozzle for fixing of rubber hose 15mmx10mm brass body suitable for working on upto 20 Kg per cm2 pressure complete all as specified and as directed
Supply and fix APFC panel 140 KVAR INCOMING: 1 Nos 250 Amps, 4P, 433 volts, 35 KVA MCCB (TMD based) Automatic power factor correction relay to sense power factor and to give 20 phased impulses for switching capacitors. Bus bar Main bus bars rated 400A suitable for 433V, 50 Hz, 3 phase and neutral aluminium bus bar shall have current density of not less than 1.0 Amp per Sqmm and the neutral bus of 50% capacity interconnects between bus bars and breakers shall be through solid copper strip. OUTGOING SECTION (A bank of 2 x 50 / 1 x25 / 1x 10 /1 x 5 KVAR Metalized Poly Propylene Heavy Duty Capacitors) STAGE 1: 2 X 50 KVAR 2 Nos. 100 Amps 3 – Pole MCCB’s Stage ON/OFF Indicating Lamps Stage ON/OFF Push Buttons Suitable contractor for 25 KVAR capacitor bank with in rush current coil. STAGE 3 : 1 X 10 KVAR 1 Nos. 32 Amps 3 – Pole MCB’s Stage ON/OFF Indicating Lamps Stage ON/OFF Push Buttons Suitable contractor for 10 KVAR capacitor bank with in rush current coil.
STAGE 4 : 1 X 5 KVAR 1 Nos. 25 Amps 3 – Pole MCB’s Stage ON/OFF Indicating Lamps Stage ON/OFF Push Buttons Suitable contractor for 5 KVAR capacitor bank with in rush current coil. The panel shall be complete with bus bars, discharge resisters, semiconductor protection HRC fuses, all internal wiring, labels, capacitor numbers in terms of switching process, all and above APFC with manual overridden facility, total in all respects and complete as required.
Supply and fixing 600mm size aluminium turbo ventilation top (Mechcanical type) with aluminium base plate and FRP profile base all as specified and as directed. Make: Air vent/ Star vent/Turbo vent/Llyd Insulations India Ltd/ Kirby building systems India Pvt Ltd/ Muilti colour steel India Pvt Ltd .
Sub Total
SARAOGI BUILDERS LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid