Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance LEH | Admitted-Finance |
Tender Value
₹2,500
EMD Value
₹1.0 L
Closing Date
26 Jun 2025, 2:00 pmClosed
Executive Engineer EDD Leh
PDD Choglamsar
same as above
2025_PDNRE_16570_1
e-NIT No. 45 of ED Leh of 2025-26 dated 14-06-2025
Open Tender
Electrical Works
Turn-key
60 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
Payable To Executive Engineer EDD Leh
₹1.0 L
2 Jul 2025
14 Jun 2025
27 Jun 2025
14 Jun 2025
26 Jun 2025
15 Jun 2025
Amount
DT (Supply Part)
250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs
120 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 100Amp and suitable MCCBs for outgoing circuits with terminal extensions
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
3-phase, 4-wire Trivector Meter with CT (LTC AMR compatible)
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, jumper binding Tape
Transformer Fencing
Installation/Testing/Commissioning Part)
250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs
120 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 100Amp and suitable MCCBs for outgoing circuits with terminal extensions
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
3-phase, 4-wire Trivector Meter with CT (LTC AMR compatible)
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, jumper binding Tape
Transformer Fencing
HT Line (Supply)
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
GI Channel X-arm including clamps and Braces for DP (80Kg/DP)
GI Channel/Angle/Flat of sizes including clamps
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
HT Line (Installation/Testing/Commissioning Part)
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
GI Channel X-arm including clamps and Braces for DP (80Kg/DP)
GI Channel/Angle/Flat of sizes including clamps
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
LT Line (Supply)
8 Mtr. Long Pole( ST-410 SP15)
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
30mm² ACSR Conductor
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
LT Line (Installation/Testing/Commissioning Part)
8 Mtr. Long Pole( ST-410 SP15)
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
30mm² ACSR Conductor
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
M/S L T POWER (BID ID -161954)
SS ELECTRICAL SERVICES (BID ID -162075)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .