Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC DUE TO L1 BIDDER | |
| 2 | L2₹11.9 L+₹82,525 (7.48%)Rejected-AOC | L2 | Rejected-AOC DUE TO NOT L1 BIDDER | |
| 3 | L3₹12.3 L+₹1.3 L (11.5%)Rejected-AOC | L3 | Rejected-AOC DUE TO NOT L1 BIDDER | |
| 4 | L4₹12.7 L+₹1.7 L (15.1%)Rejected-AOC | L4 | Rejected-AOC DUE TO NOT L1 BIDDER | |
| 5 | L5₹12.8 L+₹1.8 L (16.0%)Rejected-AOC | L5 | Rejected-AOC DUE TO NOT L1 BIDDER |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
4 Nov 2019, 6:00 pmClosed
GE ARMY BARMER
GE ARMY BARMER MES JALIPA MIL STATION BARMER
REPAIR MAINTENANCE OF STREET LIGHT SECURITY LIGHT HIGH MAST LIGHT LIGHTNING PROTECTION VOLTAGE STABILIZER AND ITS CONNECTED ITEMS AT JALIPA ZONE A AND ASCON NODES UNDER GE ARMY BARMER
2019_MES_286250_1
GE(A)/BMR-31 OF 2019-20
Open Tender
Miscellaneous Works
Item Wise
270 days
GE ARMY BARMER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹24,000
Yes
4 Jun 2020
30 Sept 2019
6 Nov 2019
30 Sept 2019
4 Nov 2019
14 Oct 2019
Amount
Disconnecting and taking down old unserviceable 70/80/125/150 watt street light fittings with brackets fixed on HT/LT poles, repairing after cleaning and replacing the un-serviceable parts like Ballast / choke, starters, ignitors, capacitors, holders, lamp etc and refixing / reconnecting after replacing wires / jumpers as required for proper functioning of street light fittings complete all as specified and as directed . Note : - (i) Parts replaced like ballasts / chokes, starters, ignitors, capacitors, holders, lamps, etc shall be measured and paid for as "Supply only" here-in-after. (ii) Cost of replacement of wornout wire of the fittings and connections as per existing size of conductor of the each fittings shall deemed to be included in the rate quoted of this item.
Supply only electronic Ignitor suitable for HPMV/ HPSV /MH fitting of 70/80/125/150 watt
Supply only copper ballast/choke with copper winding for street light fitting of HPSV/MH 150 watt.
Supply only copper ballast/choke with copper winding for street light fitting of HPSV/MH 70 watt.
Supply only MH tubular lamp for street light fitting of 150 watt.
Supply only MH lamp double ended for street light fitting 70 watt
Supply only lamp holder assembly as per existing make suitable for HPSV/MH fitting up to 400 watt
Disconnecting and taking down old unserviceable LED street light fittings with brackets fixed on HT/LT/Street light poles, repairing after cleaning and replacing the un-serviceable parts and refixing / reconnecting after replacing wires / jumpers as required for proper functioning of street light fittings complete all as specified and as directed . Note : -(i) Parts replaced shall be measured and paid for as "Supply only" here-in-after. (ii) Cost of replacement of wornout wire of the fittings and connections as per existing size of conductor of the each fittings shall deemed to be included in the rate quoted of this item.
Supply only Driver for LED 25 Watt Make :- Bajaj / Havells / CG
Supply only Driver for LED 45 Watt Make :- Bajaj / Havells / CG
Supply only Driver for LED 60 Watt Make :- Bajaj / Havells / CG
Supply only Driver for LED 90 Watt Make :- Bajaj / Havells / CG
Supply only surge protector for LED 25 to 90 Watt Make :- Bajaj / Havells / CG
Supply, fix ,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 40 watt , impact resistance, fixed on pole including taking down unserviceable light fitting complete all as specified and as directed . Make : CG Cat Part No. LSTP - 40 - CDL or techno commercially equivalent model of make Bajaj/Philips/Havells
Supply, fix ,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 45 watt , impact resistance, fixed on pole including taking down unserviceable light fitting complete all as specified and as directed . Make : CG Cat Part No. LSTP - 45- CDL or techno commercially equivalent model of make Bajaj/Philips/Havells
Supply, fix ,connecting and testing of energy efficient, pressure die cast housing with heat resistant toughened glass and individual high power LEDs with secondary optics and IP-66 protection of street light luminaries 60 watt , impact resistance, fixed on pole including taking down unserviceable light fitting complete all as specified and as directed . Make : CG Cat Part No. LSTP - 60 - CDL or techno commercially equivalent model of make Bajaj/Philips/Havells
Supply, fix ,connecting and testing of Lithium base Energy Efficient integrated solar street light 16 watt in FRP body encases solar PV panel 30/35wp monocrystalline,lithium battery 11.1/12.8V,19.8 AH with built in BMS, High brightness W-LED(120-1601m/watt) lamp,CRI 80,color temperature 6500K, Micro controller based charge controller cum driver with automatic dimming function,dusk to down operation,LUX output 30-35(from 5-6 mtr height),working temperature (-)10°c to (+)55°c,weight 8-9 Kg with adjustable MS clamp suitable for pole/wall mounting protection from short circuit, overload,reverse polarity and battery protections including taking down unserviceable light fitting complete all as specified and as directed. Make : Axxon - AXN - 16 watt or techno commercially equivalent model of make Bajaj/Philips/CG
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in deep for foundation of pole, laying of cable etc, and getting out in any type of soil complete all as specified and as directed .
Removing excavated materials to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and as directed.
Supply and spreading tibba sand in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.
Supply and laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-1by using 20mm graded crushed stone aggregate as in padestal, coping of pole including necessary form work complete all as specified and as directed.
Supply, laying, jointing and testing PVC insulated,unsheathed,multi-stranded,two core,aluminium conductor cable 4.00 sqmm in two runs through and including 25 mm dia PVC rigid conduit with all fixing acessories laid in trenches not exc 30 cm in depth including necessary excavation and earth work in any type of soil or fixed to pole and taking down old unserviceable cable and conduit complete all as specified and as directed. Note :- Two runs of two core 4 sqmm cable and one run of PVC conduit shall be measured as one unit length for the purpose of measurement.
Supply, laying, jointing and testing PVC insulated,unsheathed,multi-stranded, two core, aluminium conductor cable 6.00 sqmm in two runs through and including 25 mm dia PVC rigid conduit with all fixing acessories laid in trenches not exc 30 cm in depth including necessary excavation and earth work in any type of soil or fixed to pole and taking down old unserviceable cable and conduit complete all as specified and as directed. Note :- Two runs of two core 6 sqmm cable and one run of PVC conduit shall be measured as one unit length for the purpose of measurement.
Taking out existing LT under ground cable 1100 volts grade PVC insulated PVC Sheathed armoured aluminium conductor of any size from trenches / ducts / pipe, on wall, poles and removing unserviceable cable from the site complete all as specified and directed .
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core for connecting of main switch unit for street light including clamping accessories wherever required complete all as specified and as directed.
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core for connecting of main switch unit for street light including clamping accessories wherever required complete all as specified and as directed.
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core for connecting of main switch unit for street light including clamping accessories wherever required complete all as specified and as directed.
Inspection and checking the defect of servo controlled voltage stabilizer 3 phase in put voltage 300-480 volts, output voltage 415+1% volt of capacity 75 KVA by visiting the installations at baytu,shiv,shayani,and chotain ascon Nodes complete all as specified and as directed Note: -(i) Parts replaced shall be measured and paid for as "Supply and fix in repairs" here-in-after. (ii)Normally visit at each Ascon unit for every 30 Days and in emergency breakdown with in 24 hours to be attended.
Inspection and checking the defect of servo controlled voltage stabilizer 3 phase in put voltage 300-480 volts, output voltage 415+1% volt of capacity 50 KVA by visiting the installations at DUND and KKB ascon Nodes complete all as specified and as directed Note: -(i) Parts replaced shall be measured and paid for as "Supply and fix in repairs" here-in-after. (ii) Normally visit at each Ascon unit for every 30 Days and in emergency breakdown with in 24 hours to be attended.
S & F in repairs controlled card for 75 KVA voltage stabilizer complete all as specified and as directed.
S & F in repairs controlled card for 50 KVA voltage stabilizer complete all as specified and as directed.
S & F in repairs Voltmeter 0-500 volts digital type square 96mm flush type complete all as specified and as directed.
S & F in repairs Ampremeter 0-50 Amps digital/Sqaure 96x 96mm flush type complete all as specified and as directed.
S & F in repairs switch for Auto/manual operation complete all as specified and as directed.
S & F in repairs CT's suitable for Ampere meter 150/10A ratio complete all as specified and as directed.
S & F in repairs CT's suitable for Ampere meter 100/5A ratio complete all as specified and as directed.
S & F in repairs LT Contactor ML-6 complete all as specified and as directed.
S & F in repairs LT Contactor ML-4 complete all as specified and as directed.
S & F in repairs servo motor complete all as specified and as directed.
S & F in repairs ON/OFF Load push button switch complete all as specified and as directed.
S & F in repairs Carbon bush suitable for 75/50 KVA complete all as specified and as directed.
Repair /Replacement of wiring of panel board of stabilizer with standard copper wire of suitable size including lugs/thimble and making connection and testing etc complete all as specified and as directed.
Repairs to High Mast light fittings of 60 to 100 watt,230/240 volts of any make, including taking down existing fittings from pole (15 Mtr height) and refixing the same in same position after replacement of unserviceable/defective parts of the fittings as required to make the fittings in smooth serviceable condition and testing complete all as specified and as directed. NOTE :- (i) Unserviceable parts required to be replaced with new one shall be measured and paid separately as "supply only" (ii) The cost of replacement of wornout wire of the fittings and connections with new one as per existing size of conductor of the each fitting shall deemed to be included in unit rate quoted.
M/s Pankaj Enterprises
M/S Dharam Chand Lal Chand Jain
M.D. CONSTRUCTION CO.
Godara Construction and General Suppliers
Rasam Engg Co.
National Rewinding Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .