Executive Engineer, ED-3rd Srinagar
Executive Engineer, ED-3rd Srinagar
Augmentation/Segregation of 11 KV Feeders to overcome LCP Constraints for Sub Division Watalkadal and M.R Gunj under the Jurisdiction of ED-III (Turnkey Basis)
2026_PDD_320662_1
ED-III /14 of 2026-27, Dated - 12/08/2026
Open Tender
Electrical Works
Turn-key
Office of Executive Engineer, ED-3rd Srinagar
Refer SBD,Technical specifications,Drawings
7 documents required · 7 mandatory
₹500
Executive Engineer, ED-3rd Srinagar
₹19,740
12 Aug 2026
12 Aug 2026
31 Aug 2026
12 Aug 2026
29 Aug 2026
16 Aug 2026
16 Aug 2026 - 20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Augumentation/Segregation of 11 KV Feeders to overcome LCP Constraints to Sub Division Watalkadal and M.R Gunj under the Jurisdication of ED-III | |||||
| 1.01 | Supply, installation, testing and commissioning of S.T. poles 9.0 Meter long swaged Type conforming to ST 410 SP-33, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole, provided at height of 300mm above the planting depth which should be 1.5 mtr (SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
1. Segregation of 11 kV shared Feeder 1 ESD MR Gunj - 02 no.
2. Segregation of 11 kV Line of Feeder 3 ESD MR Gunj - 05 no.
3. Augmentation of 11 kV line portion of Feeder 5 ESD MR Gunj - 00 no.
4. Augmentation of HT Line of Feeder 2 from R/S JVC ESD Watalkadal - 02 no | 9 | No. | - | - |
| 1.02 | Supply, Installation, Testing and commissioning of S.T. poles 8.0 Meter long swaged Type conforming to ST 410 SP-15, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 15). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
1. Segregation of 11 kV shared Feeder 1 ESD MR Gunj - 03 no.
2. Segregation of 11 kV Line of Feeder 3 ESD MR Gunj - 00 no.
3. Augmentation of 11 kV line portion of Feeder 5 ESD MR Gunj - 00 no.
4. Augmentation of HT Line of Feeder 2 from R/S JVC ESD Watalkadal - 00 no. | 3 | No. | - | - |
| 1.03 | Supply, Laying, stringing, testing and commissioning of 50 mm² ACSR Conductor
1. Segregation of 11 kV shared Feeder 1 ESD MR Gunj - 00 mtr
2. Segregation of 11 kV Line of Feeder 3 ESD MR Gunj - 00 mtr
3. Augmentation of 11 kV line portion of Feeder 5 ESD MR Gunj - 00 mtr
4. Augmentation of HT Line of Feeder 2 from R/S JVC ESD Watalkadal - 700 mtr. | 700 | Mtr | - | - |
| 1.04 | Supply, Laying, stringing, testing and commissioning of 100 mm² ACSR Conductor
1. Segregation of 11 kV shared Feeder 1 ESD MR Gunj - 00 mtr
2. Segregation of 11 kV Line of Feeder 3 ESD MR Gunj - 300 mtr.
3. Augmentation of 11 kV line portion of Feeder 5 ESD MR Gunj - 300 mtr.
4. Augmentation of HT Line of Feeder 2 from R/S JVC ESD Watalkadal - 00 mtr | 600 | Mtr | - | - |
| 1.05 | Supply, installation, testing and commissioning of Gapless Surge Arrestor, 9 KV, 10 KA, Lighting Arrestor Set Heavy duty with Polymer Housing, Station type conforming to IEC-99-4 Capable of withstanding Maximum continuous operating voltages (M.C.O.V)
1. Segregation of 11 kV shared Feeder 1 ESD MR Gunj - 01 set
2. Segregation of 11 kV Line of Feeder 3 ESD MR Gunj - 00 set
3. Augmentation of 11 kV line portion of Feeder 5 ESD MR Gunj - 01 set.
4. Augmentation of HT Line of Feeder 2 from R/S JVC ESD Watalkadal - 00 no. | 2 | Set | - | - |
| 1.06 | Supply, installation, testing and commissioning of 11 KV Horn Gap Fuse Set 3 Phase 200A as per Relevant IS.
1. Segregation of 11 kV shared Feeder 1 ESD MR Gunj - 01 set
2. Segregation of 11 kV Line of Feeder 3 ESD MR Gunj - 00 set
3. Augmentation of 11 kV line portion of Feeder 5 ESD MR Gunj - 00 set.
4. Augmentation of HT Line of Feeder 2 from R/S JVC ESD Watalkadal - 00 set. | 1 | set | - | - |
| 1.07 | Supply, installation, testing and commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type conforming: IS-2544, IS: 5340 (Part-III) and SS: 9921 (Part-I -V)
1. Segregation of 11 kV shared Feeder 1 ESD MR Gunj - 01 Set.
2. Segregation of 11 kV Line of Feeder 3 ESD MR Gunj - 00 no.
3. Augmentation of 11 kV line portion of Feeder 5 ESD MR Gunj - 00 no.
4. Augmentation of HT Line of Feeder 2 from R/S JVC ESD Watalkadal - 00 no. | 1 | Set | - | - |
| 1.08 | Supply , installation, testing and commissioning of 11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch
1. Segregation of 11 kV shared Feeder 1 ESD MR Gunj - 00 set
2. Segregation of 11 kV Line of Feeder 3 ESD MR Gunj - 00 set
3. Augmentation of 11 kV line portion of Feeder 5 ESD MR Gunj - 01 set
4. Augmentation of HT Line of Feeder 2 from R/S JVC ESD Watalkadal - 00 set | 1 | set | - | - |
| 1.09 | Supply, fabrication, installation, testing and commissioning of G.I Channel X/V crossarm Iron / Angle Iron /Flat of sizes including Top Bracket, clamps and collars/ (As per KPDCL approved drawing)
1. Segregation of 11 kV shared Feeder 1 ESD MR Gunj - 300 Kgs.
2. Segregation of 11 kV Line of Feeder 3 ESD MR Gunj -250 Kgs
3. Augmentation of 11 kV line portion of Feeder 5 ESD MR Gunj -120 Kgs
4. Augmentation of HT Line of Feeder 2 from R/S JVC ESD Watalkadal - 209 Kgs.(F Top 15 nos& Pole coller (51 nos.) | 879 | kgs | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
SBD14.pdf
Tender Documents • 1.07 MB
BOQ_1066927.xls
BOQ • 0.36 MB
Combineapprovedkpdcl.pdf
Other Document • 28.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].