Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.2 Cr
Closing Date
6 Sept 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Pritam Kumar
POWERGRID CORPORATION OF INDIA LIMITED, Eastern Region-I Headquarter (ER-I RHQ), Board Colony, Near Transformer Repair Works, Shastri Nagar, Patna, Bihar 800023, PATNA, BIHAR-800023, India
Construction of TL Maintenance cum Facility Building at Patna Substation
5002001799/OTHERS/DOM/D01 - ER1 RHQ -2
Open
Civil Works - Others
Works
Patna, Bihar
₹5,000
6 Sept 2021
23 Jul 2021
6 Sept 2021
23 Jul 2021
6 Sept 2021
23 Jul 2021
Name of the Package Construction of TL Maintenance cum Facility Building at Patna Substation
Construction of TL Maintenance cum Facility Building at Patna Substation
1 Fill only Green shaded cells in Details and Schedule-I.
2 All the cells in Summary will be auto filled, therefore no cell is required to be filled in that sheet.
3 Instructions ,if any will be displayed automatically after selecting the cell.
Click here to proceed.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Construction of TL Maintenance cum Facility Building at Patna Substation
Enter the following details of the bidder
Name of the bidder
Alternative E-mail
BOQ (CIVIL) FOR TL MAINTENANCE CUM FACILITY BUILDING AT PATNA SUBSTATION.
Si No DSR'2018 Ref. no. Item Description Unit Qty Rate (as per DSR'18) Unit Rate Amount
1 2.8 Earth work in excavation by mechanical means ( Hydraulic excavator)/ manual means in foundation trenches or drains (not exceding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed, with all lead & lifts.
2 2.25 Filling available excavated earth(excluding rock) in trenches , plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum 196.00 219.65 196.12 38439.52
3 2.27 Supplying and filling in plinth with local sand under floors including, watering, ramming consolidating and dressing complete. Cum 151.00 1953.05 1743.79 263312.29
4 BCD-18 11.72 Providing brick of class designation 75 in one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per specification and direction of Engineer-in-charge. Sqm 368.00 277.50 247.77 91179.36
SECTION-II (RCC / PCC WORK) 0.00
5 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-all work upto plinth level. 0.00
4.1.8 1:4:8 ( 1 Cement:4 coarse sand: 8graded stone aggregate 40 mm nominal size) Cum 10.50 5789.60 5169.29 54277.55
6 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-all work upto plinth level. 0.00
4.1.4 1:2:4 ( 1 Cement:2 coarse sand: 4 graded stone aggregate 40 mm nominal size) Cum 17.20 6680.20 5964.46 102588.71
7 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-all work upto plinth level. 0.00
5.1.2 1:1:5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) Cum 66.50 7718.25 6891.29 458270.79
8 5.3 Reinforced cement concrete work in roof beams, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:11/2:3 ( 1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). Cum 133.00 9763.80 8717.68 1159451.44
9 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centring, shuttering, finishing, and reinforcement. 0.00
5.2.2 1:1:5:3 ( 1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) Cum 20.50 9306.00 8308.93 170333.07
10 5.22 Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. 0.00
5.22.6 Thermo-mechanically treated bars Kg 25000.00 83.50 74.55 1863750.00
11 Centering & shuttering including struting,propping etc. and removal of form for:- 0.00
a 5.9.1 Foundation, footings, bases of columns etc. for mass concrete Sqm 43.00 284.85 254.33 10936.19
b 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 250.00 733.70 655.09 163772.50
c 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 692.00 552.05 492.90 341086.80
d 5.9.4 Shelves (Cast in situ) Sqm 188.00 693.05 618.79 116332.52
e 5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 493.00 693.05 618.79 305063.47
f 5.9.19 Weather shade, Chajjas, corbels etc., including edges Sqm 15.00 766.75 684.60 10269.00
g 5.9.7 stairs,( excluding landing except spiral-staircases) Sqm 34.00 622.35 555.67 18892.78
h 5.9.15 Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like Sqm 28.00 284.15 253.71 7103.88
cornices, window sills, string courses, bands, copings, bed plates, 0.00
12 6.1.2 anchor blocks and the like sqm 196.45 Cum 2.30 6157.45 5497.72 12644.76
13 6.4.2 Brick work with F.P.S. bricks of class designation 75, in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 (1 cement: 6 coarse sand). Cum 142.60 7590.45 6777.19 966427.29
14 6.13.2 Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level . Cement mortar 1:4 ( 1 cement :4 coarse sand ) Sqm 35.00 932.10 832.23 29128.05
SECTION-IV (PLASTERING WORK) 0.00
15 13.16 6mm cement plaster to ceiling of mix: 0.00
16 13.4 12mm cement plaster of mix: 0.00
17 13.76 Forming groove of uniform size from 12 x 12mm and upto 25 x 15mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the ecges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge. Metre 315.00 86.75 77.46 24399.90
SECTION-V (FLOORING WORK) 0.00
18 11.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. Sqm 370.00 854.30 762.77 282224.90
19 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : Sqm 50.00 1531.85 1367.72 68386.00
20 11.37 Providing and laying ceramic glazed floor tiles 300x300 mm( thickness to be specified by the manufacturer )of 1st quality conforming to IS:15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement:4 Coarse sand )including pointing the joints in white cement mixed and matching pigment etc. complete. Sqm 27.00 926.90 827.59 22344.93
21 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. Sqm 26.00 1810.05 1616.12 42019.12
22 8.31 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 ( thickness to be specified by the manufacture) of approved make in all colours, shades except begundy, bottle green,blackof any size as approved by Engineer-in-chage in skirting, risers of steps and dados over 12mm thick bed of Cement Mortar 1:3 (1 Cement:3 Coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Sqm 73.00 1030.30 919.91 67153.43
23 11.6.1 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick Sqm 31.00 521.15 465.31 14424.61
SECTION-VI (CARPENTARY, STEEL AND HARDWARE WORK) 0.00
24 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 0.00
25 9.21 Providing and fixing ISI marked flush door shutters non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 0.00
9.21.1 35 mm thick including anodised aluminium butt hinges with necessary screws. Sqm 37.00 1886.70 1684.55 62328.35
26 10.10.1 Providing and fixing ISI marked steel glazed doors, windows and ventilators of standard rolled steel sections, joints mitred and welded with 15x3mm lugs, 10 cm long, embedded in cement concrete blocks 15x10x10cm of 1:3:6 ( 1 cement:3coarse sand:6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of glass panes with glazing clips and special metal sash putty of approved make complete including applying a priming coat of approved steel primer, excluding the cost of metal beading and other fitting except necessary hinges or pivots as required as per drawing at all level. 0.00
10.10.1 Windows fixed / side hung / top hung Kg 495.00 63.00 56.25 27843.75
27 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete 0.00
9.48.2 Fixed to opening / wooden frames with rawl plugs screws etc. Kgs 1220.00 183.50 163.84 199884.80
28 10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20 x10 x2 mm and braced with flat iron diagonals 20 x 5 mm size with top and bottom rail of T- iron 40 x40 x6 mm with 40 mm dia. Steel pulleys complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. Sqm 8.80 8670.50 7741.52 68125.38
29 10.25 Steel work welded in built-up sections/ frame work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required 0.00
10.25.2 In gratings,frames,guard bars, ladders, etc. Kgs 300.00 131.00 116.96 35088.00
30 10.26 Providing and fixing hand rail by welding etc. to steel ladder railings anstaircases railing including applying a priming coat of approved steel primer 0.00
10.26.1 M S tube ( medium) 40 mm nominal bore Kgs 250.00 145.65 130.04 32510.00
31 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodiccoating not less than grade AC 10 as per IS : 1868), transparent or dyed torequired colour or shade, with nuts and screws etc. complete : 0.00
32 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 0.00
33 9.98 Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete. each 7.00 85.95 76.74 537.18
34 9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 0.00
35 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 0.00
9.101.2 Twin rubber stopper Each 14.00 62.05 55.40 775.60
36 21.11 Providing and fixing stainless steel (SS304 grade ) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of engineer-in-charge complete 0.00
37 21.13 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete each 60.00 458.55 409.42 24565.20
SECTION-VII (FINISHING WORK) 0.00
38 13.80 Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Sqm 1294.00 115.15 102.81 133036.14
39 13.47 Finishing walls with premium Acrylic smooth exterior paint with silicone additives of required shade: 0.00
13.47.1 New work (Two or more coats applied @ 1.43kg/10sqm) over and including base coat of waterproffing cement paint Snowcem Plus or equivalent applied @ 2.20 kg/10 sqm Sqm 690.00 161.15 143.88 99277.20
40 13.41 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade 0.00
13.41.1 New work (two or more coats) over and including priming coat with cement primer. Sqm 1294.00 153.45 137.01 177290.94
41 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: 0.00
13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved band and manufacure Sqm 241.00 177.15 158.17 38118.97
SECTION-VIII (MISCELLANEOUS ITEMS)
42 10.18 Providing and fixing circular/hexagonal M.S sheet ceiling fan box with clamp of internal dia 140 mm, 73 mm height, 3 mm thick rim, top and bottom lid of 1.5 mm M.S sheet. Lids shall be screwed into M.S box by means of 3 mm round headed screws, clamps shall be made of 12 mm dia M.S bar bent to shape as per standard drawing with over all length as 80 cm. Each 42.00 172.25 153.79 6459.18
43 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces / sunken slabs etc consisting of following operations. 0.00
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS:2645 and approved by engineer -in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. 0.00
Laying brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1cement: 5 coarse sand) admixed with proprietary water profing compound conforming to IS: 2645 over 20mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand) admixed with prorietary water proofing compound conforming to IS: 2645 and appeoved by engineer-in-charge to requiredslope and treating similary the adjoining walls upto 300mm height including rounding of junctions to walls and slabs. 0.00
After twodays of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with proprietary water proofing compound conforming to IS: 2645.and approved by engineer-in charge. 0.00
Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement:4 coarse sand) admixed with proprietary water proofingcompound conforming to IS: 2645 and laying approved by engineer - in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowelwith neat cement slurry and making pattern of 300 x 300 mm square 3 mm deep. 0.00
The whole terraceso finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Enigneer-in-charge. 0.00
The whole twrrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test . all above operations to be done in order and as directed and specified by engineer - in - charge. 0.00
22.7.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm Sqm 250.00 1398.50 1248.66 312165.00
44 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. Each 6.00 244.05 217.90 1307.40
45a 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm diameter Metre 50.00 305.05 272.37 13618.50
b 12.42 .5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion., 110 mm bend Each 12.00 129.85 115.94 1391.28
c 12.42.6.2 Providing and fixing on wall face unplasticised -PVC moulded fittings/accessories for unplasticised -Riging PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.Shoe( plain) 110 mm shoe Each 6.00 113.80 101.61 609.66
d 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50 x 50 x 50mm hard wood plugs, screwed with M.s screws of required length including cutting brick work and fixing in cement mortar 1;4 (1 cement: 4 coarse sand) and making good the wall etc. complete.110 mm Each 26.00 288.80 257.86 6704.36
46 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement:3 coarse sand: 6 graded stone aggregate 20mm nominal size) over 75mm bed od dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sane including finishing the top smooth. Sqm 60.00 614.05 548.26 32895.60
47 16.3.1+16.4+20% of 2.27 Providing & filling stone boulders 90 mm to 45 mm nominal size in layers not more than 100mm thick mixed with sand, properly compacted through plate vibrators etc. complete in foundation and plinth as per drawing and directions of Engineer-in-charge. Cum 47 2,997.91 2676.71 125,805
Total DSR Amount (A) 8636370.30
Total Non- DSR Amount (B) 91179.36
Grand Total(D=A+B+C) 10298508.60
BOQ PHE work i.r.o Construction TL MAINTENANCE CUM FACILITY BUILDING at Patna Sub-station
Si No DSR'2018 Ref. no. Item Description Unit Qty Rate (as per DSR'18) Unit rate Amount
1 18.49.1 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : ( 15mm nominal bore ) Each 5.00 418.95 374.06 1870.30
2 18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore Each 3.00 552.35 493.17 1479.51
3 18.52.1 Providing and fixing C.P. brass stop cock ( concealed) of standard design and of approved make confirming to IS:8931 0.00
15 mm nominal bore Each 9.00 606.25 541.29 4871.61
4 18.21 Providing and fiixng PVC connection pipe with brass unions 0.00
18.21.2 45 cm length 0.00
5 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 0.00
6 Supplying fitting and fixing the following items complete with all materials as per specifications and direction of E/I 0.00
a 17.33 Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P brass brackets and guard rail complete fixed with 40mm long screws, rawl plugs etc., complete Each 3.00 841.80 751.61 2254.83
b 17.31 Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass ( of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete Each 3.00 1283.05 1145.58 3436.74
c 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 0.00
17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms Each 3.00 595.50 531.70 1595.10
d 17.34 Providing and fixing toilet paper holder 0.00
e 18.64 Providing and fixing Shower . 0.00
Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms Each 2.00 111.75 99.78 199.56
7 18.10 Providing and fixing G.I pipes complete with G.I fittings and clamps, including and making good the wall etc. (internal work) 0.00
Exposed on wall 0.00
18.10.2 20 mm dia nominal bore Metre 20.00 344.10 307.23 6144.60
18.10.3 25 mm dia nominal bore Metre 15.00 438.00 391.07 5866.05
18.10.4 32 mm diua nominal bore Metre 30.00 529.70 472.95 14188.50
18.10.5 40 mm dia nominal bore Metre 100.00 639.60 571.07 57107.00
8 18.11 Providing and fixing G.I. concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 0.00
a 18.11.1 15 mm dia nominal bore Metre 50.00 447.60 399.64 19982.00
a 18.11.2 20 mm dia nominal bore Metre 30.00 494.10 441.16 13234.80
9 18.38. Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 0.00
18.38.2 20 mm dia nominal bore Metre 20.00 18.15 16.21 324.20
18.38.3 25 mm dia nominal bore Metre 15.00 23.70 21.16 317.40
18.38.4 32 mm diua nominal bore Metre 30.00 28.40 25.36 760.80
18.38.5 40 mm dia nominal bore Metre 100.00 33.40 29.82 2982.00
10 18.17 Providing and fixing brass gate valve with C.I wheel of approved quality (screwed end) 0.00
11 17.28 Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete. 0.00
17.28.1 semi rigid pipe 0.00
12 18..48 Providing and placing on terrace ( at all level ) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular Tank per litre 2000.00 8.80 7.86 15720.00
II- SANITARY INSTALLATION 0.00
13 17.1.1 Providing and fixing water closet squatting pan (Indian type W.C pan) with 100 mm P or S -trap 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. 0.00
White Vitreous china Orissa patterns W.C pan of size 580 mm x 440 mm with integral type foot rest. Each 3.00 5421.50 4840.63 14521.89
14 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 0.00
17.3.2 W.C. pan with ISI marked black solid plastic seat and lid Each 1.00 6564.60 5861.25 5861.25
15 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required; 0.00
17.7.4 White vitreous china flat back wash basin size 550 x 400 mm with single 15 mm C.P. brass pillar tap. Each 3.00 2510.45 2241.47 6724.41
16 17.05 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 0.00
17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern Each 3.00 9360.60 8357.68 25073.04
17 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 MM. Metre 24.00 305.05 272.37 6536.88
18 12.42 Providing and fixing on wall face unplasticised -PVC moulded fittings/accessories for unplasticised -Riging PVC pipes conforming to IS:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 0.00
A 12.42.3.2 Single tee with door 0.00
b 12.42.4 single tee without door 0.00
D 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50 x 50 x 50mm hard wood plugs, screwed with M.s screws of required length including cutting brick work and fixing in cement mortar 1;4 (1 cement: 4 coarse sand) and making good the wall etc. complete.110 mm Each 20.00 288.80 257.86 5157.20
19 17.56.1.1 Providing and fixing terminal guard 100 mm dia ( Sand cast iron S & S as per IS - 3989 Each 4.00 355.95 317.81 1271.24
20 17.6 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 0.00
III - SEWERAGE 0.00
21 19.6 Providing and laying non-pressure NP2 class( light duty) R.C.C pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand) including testing of joints etc. complete. 0.00
22 2.13 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 0.00
All kinds of soil. 0.00
2.13.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. Metre 100.00 801.85 715.94 71594.00
23 (a) 19.7 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement: 4 coarse sand) R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix ( 1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 ( 1cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement: 2 coarsesand:4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design: 0.00
19.7.1 Inside size 90x80 cm and 45 cm deep including C.I cover with frame (light duty) 455 x 610mm internal diamensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame of 15 kg) 0.00
(b) 19.7.2 Inside size 120 x 90cm deep including C.I cover with frame (medium duty) 500mm internal diameter, total weight of cover and frame to be not less than 116 kg(weight of cover 58 kg and weight of frame 58 kg.) 0.00
24 19.4 Providing and fixing square-mouth S.W gully trap grade 'A' complete with C.I grating brick masonry chamber with water tight C.I cover with frame of 300 x 300mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 0.00
19.4.3 180 x 150mm size P type 0.00
19.4.3.1 With F.P.S Bricks class designation 75 Each 5.00 2409.60 2151.43 10757.15
25 19.32 Making soak pit 2.5m diameter 3.0metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W drain pipe 100 mm diameter, 1.8m long complete as per standard design. 0.00
IV - SEPTIC TANK OF SIZE (3mx0.90x1.2m ) 0.00
26 2.8 Earth work in excavation in foundation trenches or drains (not exceding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 0.00
2.8.1 All kinds of soil Cum 9.00 252.30 225.27 2027.43
27 2.27 Supplying and filling in plinth with local sand under floors including, watering, ramming consolidating and dressing complete. Cum 0.90 1953.05 1743.79 1569.41
28 BCD-18 11.72 Providing brick of class designation 75 in one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per specification and direction of Engineer-in-charge. Sqm 6.00 277.50 247.77 1486.62
29 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-all work upto plinth level. 0.00
4.1.5 1:3:6 ( 1 Cement::3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Cum 0.50 6259.10 5588.48 2794.24
30 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-all work upto plinth level. 0.00
5.1.3 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) Cum 1.70 7296.35 6514.60 11074.82
31 5.22 Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. 0.00
5.22.6 Thermo-Mechanically treated bars kg 200.00 83.50 74.55 14910.00
32 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: 0.00
a 5.9.1 Foundation, footings, bases of columns etc. for mass concrete Sqm 1.47 284.85 254.33 373.87
b 5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 4.50 693.05 618.79 2784.56
c 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 0.60 552.05 492.90 295.74
d 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 3.00 733.70 655.09 1965.27
33 6.4 Brick work with F.P.S bricks of class designation 100 A in foundations and plinth in: 0.00
6.4.1 Cement mortar 1:4 ( 1 cement: 4 coarse sand) Cum 3.00 7809.25 6972.54 20917.62
34 6.13 Half brick masonry with bricks of class designation 100 A in foundations and plinth in: 0.00
6.13.2 Cement mortar 1:4 ( 1 cement: 4 coarse sand) sqm 1.75 932.10 832.23 1456.40
35 13.06 20 mm cement plaster of mix 0.00
36 19.34.2 Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1( 1 cement : 1 fine sand ) including testing of joints etc. complete 150 mm dia Each 2.00 494.75 441.74 883.48
37 19.18 Supplying and fixing C.I cover without frame for manholes: 0.00
19.18.2 500 mm diameter C.I cover (medium duty) the weiht of he cover to be not less than 58 kg. Each 2.00 3202.90 2859.73 5719.46
38 19.15 Providing M.S foot rests including fixing in manholes with 20 x 20 x 10 cm cement concrete blocks 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) as per standard design: 0.00
19.15.1 With 20 x 20 mm square bar Each 8.00 422.20 376.96 3015.68
Total DSR Amount (A) 663417.94
Total Non- DSR Amount (B) 1486.62
Grand Total(D=A+B+C) 784587.39
BOQ For Electric work i.r.o Construction of TL MAINTENANCE CUM FACILITY BUILDING at Patna Sub-station
Si No DSR'2018 Ref. no. Item Description Unit Qty Rate (as per DSR'18) Unit Rate Amount
S.H. I : WIRING
1 1.10 Point wiring in PVC conduit, with modular type switch: Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq mm FR LS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required. (MAKE : POLYCAB / FINOLEX / HAVELLS ETC.)
2 1.11 Twin Control point wiring in PVC conduit with modular type switch: Wiring for twin control light point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 FRLS PVC insulated copper conductor single core cable etc. as required. Point 0.00 1057.00 943.75 0.00
3 1.12 Power plug wiring in PVC conduit (2X4 sq. mm.) : Wiring for light / power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 no. 4 sq. mm FRLS PVC insulated copper conductor singlre core cable for loop earthing as required. Meter 480.00 200.00 178.57 85714.29
4 1.14 Circuit / sub main wiring in PVC conduit : Wiring for circuit / submain wiring alongwith earthwire with the following sizes of PVC insulated copper conductor, singlre core cable in surface / recessed PVC conduit as required.(MAKE : POLYCAB / FINOLEX / HAVELLS ETC.)
(c ) 1.14.4 2 x 6 sq.mm. + 1 x 6 sq. mm earth wire Meter 0.00 249.00 222.32 0.00
5 1.18 Telephone wiring in existing conduit: Supplying and drawing following pair, 0.5 sq. mm FR PVC insulated copper conductor, unarmoured telephone cables in existing surface / recessed steel / PVC conduit as required (Make : D-link)
6 1.19 TV cable in existing conduit: Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid core copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel / PVC conduit as required. (MAKE : POLYCAB / FINOLEX ETC.) Metre 50.00 33.00 29.46 1473.21
7 1.21 S/F PVC conduit: Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recess conduit as required.
8 1.24 S/F modular type switch/ socket : Supplying and fixing following modular switch / socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required. (MAKE: HAVELLS/ ROMA/ D-LINK ETC.)
(C) 1.24.06 Telephone socket outlet Each 4.00 119.00 106.25 425.00
(d) 1.24.05 6pin15/16 socket outlet Each 2.00 175.00 156.25 312.50
(f) 1.24.07 TV antena socket outlet Each 2.00 119.00 106.25 212.50
9 1.27 S/F modular boxes, base & cover plate: Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess as required. (MAKE: HAVELLS/ ROMA ETC.)
10 1.26 S/F modular type blanking plate: Supplying and fixing blanking plate on the existing modular plate & switch box excluding modular plate as required. Each 40.00 32.00 28.57 1142.86
11 1.31 S/F light plug point modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required.( For light plugs to be used in non residential buildings.) (MAKE: HAVELLS/ ROMA/ ANCHOR ETC.) Each 10.00 401.00 358.04 3580.36
12 1.32 S/F power plug point modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.(MAKE: HAVELLS/ ROMA/ ANCHOR ETC.) Each 31.00 495.00 441.96 13700.89
13 2.18 S/F 20A SPN MCB industrial socket outlet:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps 'C' series, SP, MCB, in sheet steel inclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (MAKE: HAVELLS/ LEGRAND ETC.) Each 1.00 1232.00 1100.00 1100.00
14 1.33 S/F ceiling rose: Supplying and fixing 3 pin, 5 amp. Ceiling rose on the existing junction box / wooden block including connection etc. as required. (MAKE: HAVELLS/ ROMA/ ANCHOR ETC.) Each 75.00 65.00 58.04 4352.68
15 1.25 Supplying and fixing stepped type eletronic fan regulator on existing modular plate switch box including connection etc. as required. (MAKE : ANCHOR/ ROMA ETC.) Each 31.00 342.00 305.36 9466.07
16 1.34 S/F holder: Supplying and fixing brass batten / angle holder including connection etc. as required. Each 7.00 117.00 104.46 731.25
17 1.41 Installation Testing and commissionig of prewired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc,directly on ceiling /wall,including connection with 1.5 sq mm FRLS insulated, copper conductor ,singlcore cable and earthing etc.as required . (MAKE: HAVELLS/ PHILIPS/ CG/ SYSKA ETC.) each 56.00 168.00 150.00 8400.00
18 Approved CE Gaya Supplying fitting and fixing 18 watt LED with tube and accessories of apprved make all complete including taxes and royalty as per specification and direction of E/I. (MAKE: PHILIPS/ SYSKA) Each 56.00 260.00 220.34 12338.98
19 1.38 Providing and fixing call Bell /buzer suitable for sigle phase 230 volts for surface Mounting all inclusive as per specification and direction of E/I.(MAKE: HAVELLS, ROMA, ANCHOR) Each 1.00 61.00 54.46 54.46
Approved CE Gaya Supplying fitting and fixing of 9W LEDbulp all complete including taxes and royalty as per specification and direction of E/I.(MAKE: PHILIPS/ SYSKA/ HAVELLS) Each 7.00 90.00 76.27 533.90
Approved CE Gaya Supplying fitting and fixing of bajaj BARTFG 120 WATT LED lamp along with all accesories including taxes and royalty as per specification and direction of E/I. Each 4.00 90.00 76.27 305.08
S.H. II : FITTINGS & ACCESSORIES ( LIGHTS)
20 Approved CE Gaya Supplying fitting and fixing 18 watt LED with tube and accessories of apprved make all complete including taxes and royalty as per specification and direction of E/I. (MAKE: PHILIPS/ SYSKA) Each 56.00 260.00 220.34 12338.98
21 Approved CE Gaya Providing and fixing call Bell /buzer suitable for sigle phase 230 volts for surface Mounting all inclusive as per specification and direction of E/I.(MAKE: HAVELLS, ROMA, ANCHOR) Each 1.00 60.00 50.85 50.85
Approved CE Gaya Supplying fitting and fixing of 9W LEDbulp all complete including taxes and royalty as per specification and direction of E/I.(MAKE: PHILIPS/ SYSKA/ HAVELLS) Each 7.00 78.50 66.53 465.68
Approved CE Gaya Supplying fitting and fixing of bajaj BARTFG 120 WATT LED lamp along with all accesories including taxes and royalty as per specification and direction of E/I. Each 4.00 1195.00 1012.71 4050.85
S.H. III : FITTINGS & ACCESSORIES ( FANS)
22 Approved CE Gaya Supplying fitting and fixing 400 mm dia sweep wall bracket fan , high quality & high speed, heavy duty ,(approved make) inclusive of all taxes royalty etc. all complete as per specification and direction of E/I. (MAKE: HAVELLS PLATINA/ USHA PREMIER/ PHILIPS ETC.) Each 1.00 2300.00 1949.15 1949.15
23 Approved CE Gaya Supplying fitting and fixing 250 mm dia exhaut fan with plastic body and blade, self closing louvers in the fan, to provide off mode protection against birds etc. inclusive of all taxes royalty etc. all complete as per specification and direction of E/I. (MAKE: USHA/ HAVELLS/ BAJAJ/ PHILIPS/ CG ETC.) Each 6.00 1100.00 932.20 5593.22
24 Approved CE Gaya Supplying fitting and fixing 1200 mm sweep ceilling fan high quality & high speed, heavy duty ,(approved make) inclusive of all taxes royalty etc. all complete as per specification and direction of E/I. (MAKE: USHA/ HAVELLS/ BAJAJ/ PHILIPS/ CG ETC.) Each 31.00 1240.00 1050.85 32576.27
S.H. III : BOARD & D.B.'s
25 Approved CE Gaya S/F TP MCB DB: Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Approved CE Gaya 4 way (4 + 12), Double door, horizontal type Each 0.00 1560.00 1322.03 0.00
Approved CE Gaya 12 way Double door SPN DB Each 2.00 1140.00 966.10 1932.20
Approved CE Gaya 6 way (4 + 18), Double door, horizontal TPN DB. Each 2.00 2490.00 2110.17 4220.34
26 2.10.1 S/F 'C' series, SP MCB: Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker, suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (MAKE: HAVELLS/ LEGRAND/ GE ETC.)
Single pole Each 60.00 199.00 177.68 10660.71
27 S/F SPN RCCB: Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.(MAKE: HAVELLS/ LEGRAND/ GE ETC.)
28 2.15.3 S/F TPN RCCB: Supplying and fixing following rating, four pole, (three phase and neutral),415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (MAKE: HAVELLS/ LEGRAND/ GE ETC.)
S.H.IV : EARTHING,CABLE,& PANEL WORK
29 5.12 proving and laying earth connection from earth electrod with 6 SWG dia G.I. wire in 15mm dia G.I. pipe earth electrode, as required. all complete as per specification and direction of E/I. Meter 30.00 188.00 167.86 5035.71
30 Approved CE Gaya Earthing with GI earth pipe 4.5 mtr long, 40mm dia inciuding accessories,and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. Each 6.00 7500.00 6355.93 38135.59
31 Approved CE Gaya Earthing with G.I earth plate 600 mm X 600mmX6mm thick including accessories and providing mansonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc . With charcorl /cock and salt as required. . Each 2.00 8000.00 6779.66 13559.32
32 Approved CE Gaya Supplying and fixing25x5mmG.I. strip in 40mm dia G.i. pipe from earth electrod all complete as per specification and direction of E/I. Meter 12.00 800.00 677.97 8135.59
33 Supplying and laying following sizesw and core PVC /XLPE insulated PVC sheathed ,heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts .(conforms to IS :1554,PART -1) (MAKE: POLYCAB/ FINOLEX/ HAVELLS ETC)
Approved CE Gaya 6 sq. mm , 2 core Meter 0.00 140.10 118.73 0.00
Approved CE Gaya 10sq. mm , 2 core Meter 0.00 190.70 161.61 0.00
Approved CE Gaya 50 sq. mm , 3.5 core Meter 0.00 298.20 252.71 0.00
Approved CE Gaya 95sq. mm , 3.5 core Meter 105.00 315.17 267.09 28044.79
34 Supplying and fixing wall mounted iron sheet cubical panel board , fabricated with following guage iron sheet , suitaable for panel mounted switch disconnector ,including bus -bar chamber , insulator , nut-bolt and painting etc as required .(But without busbar copper strip).
Approved CE Gaya With 14 SWG Iron sheet sqf 24 830.20 703.56 16885.42
35 Providing and fixing following rating and capacity four pole MCCB in existing panel board ,including drilling holes in cubical panel, making connection s,etc . as required (MAKE: GE/ LEGRAND/ HAVELLS ETC.)
Approved CE Gaya 100A 16 KA Each 1 3995.00 3385.59 3385.59
Approved CE Gaya 125A 16 KA Each 1 5395.00 4572.03 4572.03
36 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty,complete with,INDICATOR LIGHT,VOLT/AMETER METER, all accessories including connections, earthing the body etc. as required.
Approved CE Gaya 200 amps Each 1 6590.00 5584.75 5584.75
37 S/F SPN RCCB: Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (MAKE: G.E./ LEGRAND/ HAVELLS ETC.)
Approved CE Gaya 63 amps Each 3 2980.00 2525.42 7576.27
38 S/F TPN RCCB: Supplying and fixing following rating, four pole, (three phase and neutral),415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.(MAKE: G.E./ LEGRAND/ HAVELLS ETC.)
Approved CE Gaya 63 amps Each 3 5078.00 4303.39 12910.17
Total DSR Amount (A) 360116.22
Total Non- DSR Amount (B) 215145.04
Grand Total(D=A+B+C) 678808.29
Construction of TL Maintenance cum Facility Building at Patna Substation
Schedule-I of Price Bid
Name of the bidder 0 To,
Address 0 Contracts and Materials Department
0 POWER GRID CORPORATION OF INDIA LIMITED
0 VIDYUT BOARD COLONY, SHASTRINAGAR, PATNA-23
Sl. No. Name of Work CIVIL WORKS(DSR) CIVIL WORKS(Non DSR) Civil Works(NON DSR) PHE Works(DSR) PHE (NON DSR) Electrical(DSR) Electrical(NON DSR) Total Cost Estimate
A Construction of TL Maintenance cum Facility Building at Patna Substation 8,636,370.30 91,179.36 663,417.94 1,486.62 360,116.22 215,145.04 9,967,715.48
TOTAL AMOUNT excl. taxes 9,967,715.48
Above (+)and below (-)(in %): To be quoted by bidder
Quoted Price 9,967,715.48
GST (in percentage )@ on Quoted Price 0.00
Total amount including taxes 9,967,715.48
Note: If any part of price which required to be filled by bidder kept blank, the bid price shall be considered as inclusive and evaluation shall be done accordingly
Date 0 Printed name 0
Place 0 Designation 0
Construction of TL Maintenance cum Facility Building at Patna Substation
Name of the bidder 0 To,
Address 0 Contracts and Materials Department
0 POWER GRID CORPORATION OF INDIA LIMITED
0 VIDYUT BOARD COLONY, SHASTRINAGAR, PATNA-23
We declare that following are our Total Bid Prices in Rupees for the expenditure incurred for the entire scope of work as specified in the specifications and documents. We have indicated Total Estimated Cost as indicated in the "Bill of Quantity(BOQ) & Prices" covering entire scope of works enclosed herewith as Schedule-I.
I Total for Installation/Services as per Schedule-I 9,967,715
II Total GST on services/Installation as per Schedule-I 0.00
III Toal BID Price including all taxes 9967715.48
Date 0 Printed Name 0
Place 0 Designation 0
RFX. No. 5002001799 NIT-397 Bid Form 2nd Envelope
BID FORM (Second Envelope)
Bid Proposal Ref. No.
Contract Services
Power Grid Corporation of India Ltd.,
Eastern Region Transmission System-I
Vidyut Board Colony Shastri Nagar
Name of Contract : Construction of TL Maintenance cum Facility Building at Patna Substation
Dear Ladies and/or Gentlemen,
Schedule-I Service/Installation charges
2.4 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced.
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 We confirm that we shall also get registered with the concerned Goods and Service Tax Authorities, in all the states where the project is located.
4.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Name of Package : Construction of TL Maintenance cum Facility Building at Patna Substation
Package No : NIT-397
Specification No. : 5002001799/OTHERS/DOM/D01 - ER1 RHQ -2
Contract Period 11 Months
: Attachments : General guidelines for filling up the Attachments : CT Analyser -NIT-397 :
Construction of TL Maintenance cum Facility Building at Patna Substation
Specification No.: 5002001799/OTHERS/DOM/D01 - ER1 RHQ -2
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(QR), 4, 5, 6, 7, 9, 10, 11, 12, 13,14, 15, 16, 17 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as per proforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. This attachment is not included here.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(n) and as per remarks in the Attach 14-IP.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Construction of TL Maintenance cum Facility Building at Patna Substation
5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Individual Firm 1
Licensee of a Manufacturer 2
Enter following details of the bidder Representative of a Manufacturer
Specify type of Bidder [Select from drop down menu] #REF!
Name of Lead Partner …….. …… ………. ……….
Address of Registered Office …….. …… ………. ……….
Name of Other Partner …….. …… ………. ……….
Printed Name …….. …… ………. ………. 01/Dec/25
Designation …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-3(JV) NIT-397 #REF! NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials #REF!
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. "Saudamini", Plot No. 2, Sector 29
…….. …… ………. ………. Gurgaon (Haryana) - 122001
Name(s) and Addresse(s) of other partner(s)
Name : #REF! #REF!
Address : #REF! #REF!
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Date : Printed Name : …….. …… ………. ………. 0
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-3(QR) NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
For our Qualifying Requirements Data, please refer Schedule-QR of this volume.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-4 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : Printed Name : …….. …… ………. ……….
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-4(A) NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. "Saudamini", Plot No. 2, Sector 29
…….. …… ………. ………. Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
S.No. For Equipment Item Description Unit Quantity
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-4(B) NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. "Saudamini", Plot No. 2, Sector 29
…….. …… ………. ………. Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-5 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-5 NIT-397
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-6 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-6 NIT-397
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-7 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Details of Alternative Bid)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
No Alternative Bid
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-8 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Manufacturer's Authorization Form)
Contracts and Materials
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001 Name of Manufecture Name/Description of Goods Factory Address Name & Address of Bidder package name alongwith project name
…(insert name of the Manufacturer) .. …(insert name and/or description of the goods) … ..(insert address of factory) .. …….. …… ………. ………. Construction of TL Maintenance cum Facility Building at Patna Substation
WE …(insert name of the Manufacturer) .. who are established and reputable manufacturers of …(insert name and/or description of the goods) …. having production facilities at ..(insert address of factory) .., , , do hereby authorize …….. …… ………. ………., …….. …… ………. ………., …….. …… ………. ………., …….. …… ………. ……….(hereinafter, the “Bidder”) to submit a bid, and subsequently negotiate and sign the Contract with you against IFB for Construction of TL Maintenance cum Facility Building at Patna Substation including the above plant & equipment or other goods produced by us. 0
WE …(insert name of the Manufacturer) .. who are established and reputable manufacturers of …(insert name and/or description of the goods) …. having production facilities at We hereby extend our full guarantee and warranty for the above specified goods offered supporting the supply by the Bidder against these Bidding Documents, and duly authorize said Bidder to act on our behalf in fulfilling these guarantee and warranty obligations.
We hereby extend our full guarantee and warranty for the above specified goods offered supporting the supply by the Bidder against these Bidding Documents, and duly authorize said Bidder to act on our behalf in fulfilling these guarantee and warranty obligations. We also hereby declare that we and …….. …… ………. ………. have entered into a formal relationship in which, during the duration of the Contract (including warranty/defects liability). We, the Manufacturer or Producer, will make our technical and engineering staff fully available to the technical and engineering staff of the successful Bidder to assist that Bidder, on a reasonable and best effort basis, in the performance of all its obligations to the Purchaser under the Contract. ..(insert address of factory) .., , , do hereby authorize …….. …… ………. ………., …….. …… ………. ………., …….. …… ………. ………., …….. …… ………. ……….(hereinafter, the “Bidder”) We also hereby declare that we and …….. …… ………. ………. have entered into a formal relationship in which, during the duration of the Contract (including warranty/defects liability).
For and on behalf of the …(insert name of the Manufacturer) .. to submit a bid, and subsequently negotiate and sign the Contract with you against IFB for Construction of TL Maintenance cum Facility Building at Patna Substation including the above plant & equipment or other goods produced by us. We, the Manufacturer or Producer, will make our technical and engineering staff fully available to the technical and engineering staff of the successful Bidder to assist that Bidder, on a reasonable and best effort basis, in the performance of all its obligations to the Purchaser under the Contract.
In the capacity of
Date : Printed Name : …….. …… ………. ……….
Note :1 The letter of Undertaking should be on the letterhead of the Manufacturer and should be signed by a person competent and having Power of Attorney to legally bind the Manufacturer. It shall be included by the bidder in its bid.
2 Above undertaking shall be registered or notarized so as to be legally enforceable.
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-9 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Work Completion Schedule)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby declare that the following Delivery Schedule shall be followed by us for the subject Package i.e., Construction of TL Maintenance cum Facility Building at Patna Substation for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of Contract
1 Submission of drawings for Approval
2 Production of samples for type testing
3 Completion of type tests
4 Commencement of Commercial Production
5 Offer of material for pre-despatch testing and inspection
6 Commencement of shipment
1 Completion of shipment (Receipt at final destination Site)
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-10 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Guarantee Declaration)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We conform that the equipments offered shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-11 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-11 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name of Other Partner To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-12 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Price Adjustment Data)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the Construction of TL Maintenance cum Facility Building at Patna SubstationThe necessary documentary evidence are enclosed :
Sl. No. Name of Materials Value of co-efficient Name of the published index * Value of index as 30 days prior to date set for opening of bids as on **
1 EC grade aluminium ingots, co-eifciant a = 0.65 CACMAI
High Tensile Galvanised Steel wires , co-efficient b = 0.15 CACMAI FALSE FALSE
High Carbon Steel Rods , co-efficient b = High Tensile Galvanised Steel wires , co-efficient b =
High Grade Electrolytic Zinc , co-efficient c =
3 Labour, Co-efficient l= 0.05 Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
Note: * Indicate the publisher of the index.
** Indicate the date of indices for which the values are being furnished.
^ For bidders who intend to quote their prices based on High Tensile Galvanised Steel wire, the coefficient for the same (i.e. coefficient ’b’ for High Tensile Galvanised Steel wire) shall be 0.15 and coefficient ‘c’ shall not be applicable.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-13 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-14 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
Bidders are required to submit 02 copy of Integrity Pact as per format enclosed at vol-I
Date : Printed Name : …….. …… ………. ……….
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact (if required)is attached in Vol-I of Bid Documents.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (n).
Specification No. : 5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-15 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Information for E-payment, PF details and declaration for Micro/Small and Medium Enterprise)
Bidder's Name and Address (Sole Bidder [Individual Firm]): To:
Contracts and Materials
Name: …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address: …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidyut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We are furishing the following details of Statutory Registration Numbers and details of Bank for electronic payment
1 Name of the Supplier/ Contractor in whose favour payment is to be made
2 Address with PIN Code and State
Registered Office:
Correspondence Address:
3 Status- Company/others [Declaration of Micro/ Small/Medium Enterprtise ]
4 Permanent Account [PAN] No.
5 Goods & Services Tax [GST] No.
6 PF Registration No. Of the Company
7 PF Regional Office covered (with Address)
8 Name of Contact Person
9 Telephone No(s)
10 Bank Details for Electronic Payment
Name ofthe Bank:
Address of the Branch:
Type of Account: Savings/Current
11 9 digit MICR code printed at bottom in middle, next to cheque no.
12 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that thepayment onaccount of this Contract, in the event of Award, be made in the above account maintained in theabove mentioned Bank.
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-16 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
(Additional Information)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the (Lead Partner) : …….. …… ………. ……….
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Description of the plant for carrying out the work
Bidders should provide information of the plant(s) for carrying out the work including the proposal of manufacturing methods in sufficient detail to demonstrate the adequacy of the bidder’s proposals to meet the technical specification.
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Type of Conductor Ordered Quantity as per Contract Balance Quantity to be supplied as on Completion Period for balance quantity
Commencement Completion
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-17 NIT-397
Construction of TL Maintenance cum Facility Building at Patna Substation
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002001799/OTHERS/DOM/D01 - ER1 RHQ -2 Bid Form 1st Envelope NIT-397 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contracts and Materials 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
Eastern Region Transmission System-I 11 eleven 11 th 11 November
Vidut Board Colony, 12 twelve 12 th 12 December
Shastri Nagar Patna 800023 13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Construction of TL Maintenance cum Facility Building at Patna Substation 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. dated 00/01/1900 the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
(b) Attachment 2(NIT-397) : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Please note that if bid validity is less than 07 (seven) months, your bid may be rejected Bank Guarantee (0) 21 st
(c) Attachment 3(NIT-397) : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3(c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). 22 th
#REF! Applicable 23 th
#REF! Not Applicable 24 th
(d) Attachment 4(NIT-397) : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. 25 th
(e) Attachment 5(NIT-397) : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 6(NIT-397) : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(g) Attachment 7(NIT-397) : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. [NOT APPLICABLE] 28 th
(h) Attachment 8(NIT-397) : Manufacturer’s Authorisation Forms. 29 th
(i) Attachment 9(NIT-397) : Work Completion Schedule. 30 th
(j) Attachment 10(NIT-397): Guarantee Declaration. 31 st
(k) Attachment 11(NIT-397): Information regarding ex-employees of Purchaser in our firm.
(l) Attachment 12(NIT-397): Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.[NOT APPLICABLE]
(m) Attachment 13(NIT-397): Declaration regarding Social Accountability.
(n) Attachment 14(NIT-397): Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.[NOT APPLICABLE]
(o) Attachment 15(NIT-397): Information for E-payment, PF Details & declaration regarding Micro/Small & Medium Enterprises.
(p) Attachment 16(NIT-397): Additional Information.
(q) Attachment 17(NIT-397): Declaration.
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Goods, in and outside of India.
4.1 100% of applicable Taxes and Duties, which are payable by the Purchaser under the Contract, shall be reimbursed by the Purchaser after despatch of goods on production of satisfactory documentary evidence by the Supplier in accordance with the provisions of the Bidding Documents.
4.3 We also understand that, in case of award on us, you shall reimburse to us octroi/entry tax as applicable for destination site/state on all items of supply. Further, Service Tax, if applicable, for the services to be rendered by us, the same is included in our bid price in Second Envelope.
4.4 We confirm that we shall also get registered with the concerned Sales Tax Authorities, in all the states where the project is located.
5.0 Construction of the Contract
5.1 We declare that we have studied clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us the Contracts covering all goods and related services.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 8 Terms of Payment
(d) GCC 9.3 Performance Security
(e) GCC 10 Taxes and Duties
(f) GCC 21.2 Completion Time Guarantee
(g) GCC 22 Defect Liability
(h) GCC 24 Patent Indemnity
(j) GCC 25 Limitation of Liability
(k) GCC 35 Settlement of Disputes
(l) GCC 36 Arbitration
(m) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide an Advance Payment Security and Performance Security(ies) in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:
Name and address of agent Amount and Currency Purpose of Commission or gratuity
(If none, state “none”)
13.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …… ………. ……….
Date : Printed Name : …….. …… ………. ……….
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 (NIT-397) : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
ElectronicForms™
View - Template of ElectronicForm™
To close this Screen, click on the [Close] button located on the bar above, or at the bottom of the Screen
Template of ElectronicForm™
Relevant Bid-Part Techical
ElectronicForm™ Template ID 7PG-2010-FT000010
Template Reference TECHNO-COMMERICIAL (First Envelope)
Template Description Tower Package NIT-397 Specification No. : 5002001799/OTHERS/DOM/D01 - ER1 RHQ -2
Construction of TL Maintenance cum Facility Building at Patna Substation
Bidders's Name #REF!
Section-2 (Outline of Requirements)
* 1 Integrity Pact Details
Submitted (Doc. Code No. DC-9008-April-2009-Rev-0) Yes
* 2 BID SECURITY DETAILS
2 (a) Submitted Yes
* 2 (b) Bid Security No.
* 2 (c) Issued by (Name of Bank)
* 2 (d) Bid Security Amount 0 0.00
* 2 (e) Valid upto
* 1. AUTHORIZED SIGNATORY (Sole Bidder / Lead Partner of JV)
1 (b) Designation …….. …… ………. ……….
2. AUTHORIZED SIGNATORY (Other Partner of JV)
(If Bidder is JV)
2 (a) Name #REF!
2 (b) Designation #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Price_Schedule.xlsx
xlsx • 0.11 MB
Annexures and attachments.xlsx
xlsx • 0.76 MB
Civil Works TS.pdf
pdf • 1.99 MB
02 Sec-II ITB SSTE S&I R4-DCB-SRM-signed.pdf
pdf • 0.46 MB
03 Section - III BDS.doc
doc • 0.10 MB
1-IFB.doc
doc • 0.09 MB
Attachment-Bid-Security Declaration.pdf
pdf • 0.17 MB
Detailed NIT.docx
docx • 0.04 MB
GCC Civil Works'.pdf
pdf • 1.76 MB
report_GEM_GARPTS_23072021_AWLXYSKWOR4K.pdf
pdf • 0.03 MB
Saftey Pact Latest.doc
doc • 0.06 MB
SCC.docx
docx • 0.05 MB
Standard Field Quality Plan Civil Works for Site Packages Revision 04.pdf
pdf • 2.22 MB
Thumbs.db
db • 0.02 MB
~$ Section - III BDS.doc
doc • 0.00 MB
~$1-IFB.doc
doc • 0.00 MB
~$SCC.docx
docx • 0.00 MB
~$tailed NIT.docx
docx • 0.00 MB
Integrity Pact.pdf
pdf • 0.51 MB
Sample Stamp Paper for Integrity Pact.pdf
pdf • 0.28 MB
Thumbs_1.db
db • 0.03 MB
date_amend_397.docx
docx • 0.01 MB
date_amend_397.docx
docx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .