Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹28,940
Closing Date
16 Aug 2023, 3:00 pmClosed
Executive Engineer, ED Budgam, KPDCL
ED Budgam, KPDCL
63 Kva transformer Lalbanjar Mohalla aripanthan on SITC Basis 63KVa Transformer at Dev Mohalla Chewdara on SITC Basis INSTALLATION OF LT POLES AT VILLAGE SUGEN,POSHKER, KHAG ,DALWASH ,BAMRADA RAWATHGPORA on SITC Basis Installation of LT imptt
2023_PDD_222777_1
EDB/27 of 2023-24
Open Tender
Electrical and Maintenance Works
Turn-key
45 days
ED Budgam, KPDCL
As per SBD
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED Budgam, KPDCL
₹28,940
Yes
31 Aug 2023
22 Jul 2023
17 Aug 2023
22 Jul 2023
16 Aug 2023
29 Jul 2023
24 Jul 2023 - 27 Jul 2023
Amount
Work items identified;
Supply, installation, testing and commisioning of 11/0.433KV, 3-phase(EE Level-II) Distribution Transformers 63 KVA with Bimetallic Terminal complete in all respect as per Relevant IS.
Supply, installation, testing and commisioning of 9 mtr (410 SP-33) long Steel Tubular Poles complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per Relevant IS.
Supply, installation, testing and commisioning of 8 mtr(410 SP-15) long Steel Tubular Poles complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per Relevant IS.
Supply, laying, stringing, tensioning, binding of 50 Sqmm ACSR Conductor complete in all respects as per Relevant IS.
Supply, laying, stringing, tensioning, binding of 30 Sqmm ACSR Conductor complete in all respects as per Relevant IS.
Supply,Carraige upto site and fixing of GI V Cross arm & GI F Top with clamps duly fabricated as per site requirement including clamps(50x6 mm), GI Nuts & Bolts,washers etc complete in all respects as perRelevant IS
Supply,Carraige upto site, fixing and installation of GI Channels of different sizes including clamps and braces.
Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV porecelain composite Pin Insulators 12 kv.5KN, Lighting impulse 75 Kv positive and 80 Kv negative, Creepage distance 320mm complete in all respects as per Relevant IS.
Supply,Carraige upto site,Installation,testing and Commissioning of 11 Kvpolymer composite Disc Insulators 12 kv.5KN, Lighting impulse 75 Kv positive and 80 Kv negative, Creepage distance 320mm complete in all respects as per Relevant IS.
Galvanized stay set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x200x6mm), nuts-bolts, 2Nos turn-buckles, 1.8m long, 16mm diameter solid GS stay Rod & 7/3.15mm dia GI stranded wire complete
Supply, Carraige upto site, installation, testing and Commissioning of Gapless Surge Arrestor 9 kV, 10 kA, LA with polymer housing, Stn. Type complete in all respects as per Relevant IS.
Supply, Carraige upto site, installation, testing and Commissioning of 11 kV G.O AB Switch 3-phase, 3pole 200-Amp, vertical Type with fittings complete in all respects as perRelevant IS.
Supply, Carraige upto site, installation, testing and Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A complete in all respects as per Relevant IS.
Supply, Carraige upto site, laying, stringing, tensioning, binding of 1.1 KV grade, 1-core 185 Sqmm PVC Conductor FRLS type complete in all respects as per Relevant IS.
Supply,Carraige upto site, fixing of Aluminium Thimbles of size 185 Sqmm.
Supply,Carraige upto site, fixing and Commissioning of Aluminium Solderless Clamps of size 185 Sqmm.
LT Distribution Box for:- i) 63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits.
Earthing of substation-Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 75 mmx10 mm, 50 mmx6 mm for connection of transformer body & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply,Carraige upto site, fixing of G I Muky Clamps. As per standards
Supply,Carraige upto site, fixing of Shackale insulators.
Cement bottoming of S T poles in 1:2:4 mix,up to 1/6th plantation depth of pole below ground, 9" above ground,circular with radius 6" around the pole girth/surface ,top surface tappered outwards 0.5 cum/pole as per the diagram given in technical specifications.
Earthing of steel tubular poles complete by GI pipe 40mm or GI rod 20mm 2.5mtr long through GI strip 25*3 mm..
Painting of Poles with one coat of Red Oxide (1ltr/pole) and two coats of alimunium paint (1ltr/pole).
Supply and fixing of GI barbed wire Anti climbind Device with clamps complete in all respects as per relevant IS.
Supply and fixing of danger plates complete in all respects as per REC Standards
Wooden Ladder(Bambo Ladder 15 feet)
Link rod
NOTE: 1.The rates quoted by the bidder for all the items shall be inclusive of GST/freight/insurance/storage/installation/testing and any other charges FOR Creation of 63 kVA new Substations along with HT/LT network under the jurisdiction of ED Budgam, KPDCL.
MOHAMMAD SADIQ LONE
MLM SERVICES & SUPPLIERS
RIM ELECTRICALS & SUPPLIERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .