Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC AT PO DANARA TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L1 | Accepted-AOC technocommercially eligible L1 bidder | |
| 2 | Rejected-Technical AT BRAHMAN SASAN PO TALCHER DIST ANGUL ODISHA 759102 | TALCHER | ANGUL | ODISHA | 759102 | - | Rejected-Technical REJECTED FOR NOT BEING L1 |
Tender Value
₹3.8 L
EMD Value
₹4,800
Closing Date
26 Nov 2024, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Construction of 11kV OH line with 2 nos DP 11 mtr long WPB Pole for Heightening of 11kV RE-II Feeder of TPCODL for Railway works of Jagannath OCP site at Rakasa, Talcher, Angul,Odisha
2024_MCL_320798_1
GM(JA)/EnM/e-Tender/24-25/ E-703/68 DTD. 08/11/24
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
TALCHER
AS PER NIT
4 documents required · 4 mandatory
₹4,800
Yes
30 Jan 2025
8 Nov 2024
29 Nov 2024
9 Nov 2024
26 Nov 2024
9 Nov 2024
9 Nov 2024 - 14 Nov 2024
Amount
Scope of the work:- 1. Construction of line DP without AB switch over 11 mtr long WPB-2 nos & 3P3W 11kV line- 0.12 CKM with 80 sqmm AAAC. 2. Line Protecting Guarding on Double Pole for road crossings- 1 Nos of Road Crossing (40 mtr). 3. Dismantling of existing line (8 mtr long RS Joist-2 nos, 80 sqmm AAAC- 0.12 KM).
Supply of WPB (GI) Pole 160× 152 (11 Mtr.Long, 30.44KG/Mtr)
Erection, Loading, Unloading of WPB pole 11 mtr height, in cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required and Muffing with Concrete ratio 1:1.5:3 with dimension 500mmX500mmX450mm
Supply of 80 sq.mm AAA CONDUCTOR
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required.(0.218kg/meter*3 wire* 1 span* 40 meter=26.16kg)
Supplying of two lengths of G.I. channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre)each of 2.3 mtr length double pole cross arm for three wire 11 KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm G.I. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts, washers etc as required for DP without Isolator
Supplying and erection of 2 set of cross bracing frame work for 11 KV over head line double pole structure (1- One cross bracing consists of 2 nos 1.66 mtr long,75 mm X 40 mm X 6 mm GI belting channel and 2nos 2.671 mtr long, 50mmX 50mmX 6mm GI bracing angle) complete with 50 mm X 6mm G.I. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc as required for DP structure with Isolator
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 50 X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply and Erection of GI barbed wire anticlimbing device 3 kg.Per support with Back Clamp 25×3 mm.flat,0.59Kg/Mtr.Flat of 0.510 mtr length 4 no's=(4×0.59×0.510) per pole and nut bolt as required
Supply & Erection of 11 KV pin polymer insulator complete with hardware and non metallic ties etc. as required.
Supply & Erection of a 11 KV disc polymer insulator,70KN for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Supply and Erection of PG clamp for 80 sq.mm AAA conductor
Clamps, bolts and nuts etc.
Supply of paint and Pole Identification, numbering by Black paint (1ltr approx for each post) with Yellow Colour paint as background(2ltr approx for each post)
Supply of Guarding channel 75x40x4.8mm, 7.14kg/mtr, each channel length 3.5 mtr, 4 nos. channel required=(4x7.14x3.5)(for double pole)
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supply of No-8 GI wire 0.131 KG/Mtr for lacing
Supply of No-6 GI wire 0.192 KG/Mtr for main string
Supply of Eye Bolt (236mm, 16mm dia, 1.577kg/mtr
Erection of cradle guard as required.
Erection of GI wire no.8 SWG including binding etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, Cl. wire, cross arms, insulators etc. as required.
Dismantling of 11kV 'V' cross arm
Dismantling of 11kV GI pin with insulator
Total impact of GST for the purpose of CTC
SIVA SHEKHAR SAHOO (BID ID -1100863)
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .