Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | ₹22.4 L Quoted ₹24.4 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹25.2 L+₹77,912 (3.19%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹25.2 L+₹77,912 (3.19%) | L2 | Rejected-Finance Other then lowest |
| 3 | L3₹27.5 L+₹3.1 L (12.6%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | ₹27.5 L+₹3.1 L (12.6%) | L3 | Rejected-Finance Other then lowest |
| 4 | L4₹32.3 L+₹7.8 L (32.1%)Rejected-Finance | ₹32.3 L+₹7.8 L (32.1%) | L4 | Rejected-Finance Other then lowest |
| 5 | L5₹37.2 L+₹12.8 L (52.4%)Rejected-Finance | ₹37.2 L+₹12.8 L (52.4%) | L5 | Rejected-Finance Other then lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
19 Sept 2022, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)-143530
Certain repair/ replacement overhead line, UG cable, connected equipment and accessories at Zone-I of Tibri Mil Stn under GE Gurdaspur.
2022_MES_547053_1
GE GSR-30/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Gurdaspur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹70,000
17 Nov 2022
23 Aug 2022
26 Sept 2022
23 Aug 2022
19 Sept 2022
7 Sept 2022
Amount
Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n.exc. 1.5m in depth for poles, stay, cable, pipe etc. or for shafts, wells, cesspits, manholes, etc. n. exc 10 sq m on plan and n exc 1.5 m in depth including taking out brick for cable protection, sand cushioning and getting out all as specified.
All as per item No.01 above but depth exc 1.5m and n. exc. 3m all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
Removal of excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and lay brick common burnt sub class "B" old size for protection of under ground cable laid in trenches complete all as specified.
M & L for sand cushioning in trenches using fine sand to under ground cable, laid in two layers complete all as specified and directed.
M&L for road cutting including excavation returning filling in spreading leveling , well ramming in layers, soling with broken boulders/ stones obtained from demolition of existing road, 7.5cm thick coarse aggregate obtained from demolition of existing WBM of road, watering and ramming, 40mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate for road patch repair work, Section/ cross section area of cutting shall be as specified and as directed by Engineer -In Charge.
M&L in repair GI tubing light grade for cable protection fixed along the pole/wall/ under road of size 100mm bore with necessary clamps, nuts and bolts complete all as specified and directed. Note for item No. 9 to 11: Clamps, nuts and bolts will be measured and paid separately under Item No. 12 here-in-after.
All as per Srl item No 08 above but 80mm bore.
All as per Srl item No 08 above but 50mm bore.
All as per Srl item No 08 above but 40mm bore.
M&L in repair of cross arms in repair, bracing, supports, clamps and brick plates, fabricated from staructural steel section including nut bolts washers including welding, bending , cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide all specified.
M&L for re-stringing/ stretching of existing ACSR conductor of any size any type as required sag fixed on OH line incl unwindinding the conductor & insulators/cross arms on poles properly binding with aluminum all as specified and directed.
M & L aluminium conductor steel reinforced (ACSR) over size of ferret, weasels, mink, beaver etc fixing stretching and jumpering joining with aluminium wire including dismantling existing complete all as specified and directed.
M&L galvanised steel wire of 4 SWG dia as earth wire for overhead line fixing of the same on the pole including dismantling existing complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured (under ground) heavy duty electic cable with stranded aluminum conductor 1100 volts grade of cross sectional area 300 Sqmm 3.5 core laid in trenches/ ducts/ through pipes/ in floor/ road/ along the pole including finding out the fault in cable and taking out faulty cable complete all as specified & directed by Engr-in-Charge. Notes : (a) Excavation earth work, road cutting, brick for cable protection and sand cushioning and joints shall be measured & paid separately. (2) The fault should be rectified within 2 days of time frame after informed to the contractor/ contractor rep by telephonically/ Whatsapp msg or letter by JE/ Engineer-in-Charge, failing which Rs. 500/- per day will be levied to the contractor as penalty.
All as per srl item No. 16 here in before but 240 Sqmm 3.5 core
All as per srl item No. 16 here in before but 185 Sqmm 3.5 core
All as per srl item No. 16 here in before but 150 Sqmm 3.5 core
All as per srl item No. 16 here in before but 120 Sqmm 3.5 core
All as per srl item No. 16 here in before but 95 Sqmm 3.5 core
All as per srl item No. 16 here in before but 70 Sqmm 3.5 core
All as per srl item No. 16 here in before but 50 Sqmm 3.5 core
All as per srl item No. 16 here in beore but 35 Sqmm 3.5 core
All as per srl item No. 16 here in before but 25 Sqmm 4 core
All as per srl item No. 16 here in before but 16 Sqmm 4 core
S&F in repair of XLPE insulated PVC sheathed single core multistranded aluminium unarmoured of 1100 volts grade cable for using as a jumper in LT overhead line wherever required of size 35 sqmm complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggreate as in foundation for poles etc. complete all as specified and directed
M&L for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggreate as in foundation of pole, stay assembly etc. complete all as specified and directed
M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggreate as in coping of poles including necessary form work and fair finish to exposed surfaces complete all as specified and directed
M&L for stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length, fixed to pole with and including F1 clamps 50x 6mm, bolt, nuts washers, GI stay rod 20mm dia and 1800 mm long stay bow 400x 14mm , GI steel plate 300x300x6mm , loop insulator of size 90x 140mm clearance hole 16 mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate No 1 of SSR Part-I 2009 on page No 495 complete including dismantling existing complete all as specified and directed. Note:- Excavation and PCC work shall measured separately)
Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 meters long) including dismantling existing complete all as specified and directed.
Supply and erecting in vertically prestressed concrete pole LT pole 9.0 mtr long 102 x 172mm at top and 102mm x 279mm at bottom class 10 including dismantling existing all as specified and directed.
Supply and fixing in repair shackle type insulator porcelain vitrous white, brown or green insulator incl galvanised mild steel straps washers insulators bolts washers of size 75mm x90mm all as specified and directed.
S&F in repair copper spreader terminal Kit for 2 side for MCCB capacity 100 Amp 4 pole any make as per existing MCCB at site complete all as specified and directed.
All as per Srl item No 35 above but for MCCB 125 to 200 Amp
All as per Srl item No 35 above but for MCCB 250 to 400 Amp
Supply and fixing in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3 ½ core XLPE, armoured, A1 conductor cable of size 240 to 300 sqmm complete all as specified and directed.
All as per Srl item No 38 above but size 150 to 185 sqmm.
All as per Srl item No 38 above but size 70 to 120 sqmm.
All as per Srl item No 38 above but size 25 to 50 sqmm.
S&F in repair LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt grade (earthed) 3 ½ core XLPE, armoured, aluminium conductor cable of size 240 to 300 sqmm complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 42 above but size 150 to 185 sqmm.
All as per Srl item No 42 above but size 70 to 120 sqmm.
All as per Srl item No 42 above but size 25 to 50 sqmm.
S&F in repair aluminium lugs eye type suitable for cable size 6 sqmm to 10 sqmm including necessary crimping with crimping tool complete all as specified and directed.
All as per Srl item No 46 above but size of 16 sqmm to 25 sqmm.
All as per Srl item No 46 above but size of 35sqmm
All as per Srl item No 46 above but size of 50sqmm
All as per Srl item No 46 above but size of 70 sqmm to 95sqmm.
All as per Srl item No 46 above but size of 120sqmm
All as per Srl item No 46 above but size of 150Sqmm
All as per Srl item No 46 above but size of 185sqmm
M & L for synthetic rubber insulated mat, ISI marked of size 2mx1mx2.5mm Conforming to IS- 15652 / 2006 for voltage upto 11 KV suitable for electrical shock safety.
Cutting/ trimming of tree branches of any width/ girth upto 3 mtr distance of LT over head lines including collection and depositing the retrived timber at a place as directed by Engr-in-Charge. Notes :- (i) Each span have a distance 35m approximately. (ii) All cutting branches of tree shall be thrown away/ burnt at approximately 500 to 700 mtr away as directed. (iii) Transport shall be provided by contractor for throwing away branches of trees, No extra payment will be made for transportation. (iv) Cutting the tree branches as and when required shall be carried out within three days after intimated telephonically/ whatsapp msg or by letter to contractor, failing to do so a penalty of Rs. 100/- per day will be levied on the contractor.
M&L for cutting/ drilling bore hole with bocki/ drilling machine under road/ floor, cross section of hole 40mm to 100mm bore complete all as specified and as directed by Engineer -In Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip 25mm x 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 32mm bore light grade GI pipe for protection of earth lead including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of 8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete including dismantling existing earthing complete all as specified & directed by Engr-in-charge.
M&L for painting to LT steel tubular pole with one coat of aluminium paint complete above ground level including all MS fitting, street light brackets MS flate angle iron GI pipe etc including 5 Nos alternate bands/ strips of 30cm wide each with two coats of radium spray/synthetic enamel paint (Red and Yellow) at a distance of 30cm from the plinth block upto 1500mm height and marking/ sign writing of pole number with thick synthetic enamel paint (white) etc. to match the existing poles including preparation of old painted surface all as specified and directed
M&L for painting the PCC pole of 5 Nos bands/ strips of 30cm wide each with two coats of synthetic enamel paint (Black and Yellow) at a distance of 30cm from the plinth block upto 1500mm height and marking/ sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) including all MS fitting street light brackets MS flate angle iron GI pipe etc. to match the existing poles complete all as specified and directed
M&L for fault detection in damage UG Cable by using cable fault detector/locator to accuracyh of 2 meter for various location in the area under GE Tibri for UG Cable of any size and any type upto 1.1 KV grade including excavation and earth work in any type of Strata 4mx2mx0.60 m to visually inspect/repair the damage cable when and where directed by Engineer-in-Charge. Note :- (i) The fault shall be rectified within 2 days of time frame after informed to the contractor/ contractor rep by telephonically/ whats app msg or letter failing which 500/- per day per complaint will be levied on the contractor as penalty. (iii) The straight through joint will be measured and paid separately under relevant items of the contract.
Taking out of faulty LT cable of any size finding out the fault in cable and relaying, jointing, tesing of serviceable LT cable complete all as specified & directed by Engr-in-Charge. Note :- (1) Excavation earth work, road cutting, brick for cable protection and sand cushioning and joints shall be measured & paid separately. (2) The fault should be rectified within 2 days of time frame after informed to the contractor/ contractor rep by telephonically/ Whatsapp msg or letter by JE/ Engineer-in-Charge, failing which Rs. 500/- per day will be levied to the contractor as penalty.
Supply and fixing in repair heavy duty PVC spiral Z type 13mm dia. spacer for LT 1100 Volt Grade suitable for 5 ACSR conductor of size required at site complete all as specified and directed.
Supply and fixing in repair heavy duty PVC spiral Z type 13mm dia.spacer for LT 1100 Volt Grade suitable for 3 ACSR conductor of size required at site complete all as specified and directed.
Supply and fixing in repair heavy duty PVC spiral Z type 13mm dia.spacer for LT 1100 Volt Grade suitable for 2 ACSR conductor of size required at site complete all as specified and directed.
Material & labour for pruning the branches of broken tree any grith on the ACSR conductor LT/HT due to strom or any situation and shall be thrown away approximately 500m away, after that jointing and restreching the broken ACSR conductor all as specified and directed by Engineer -in- Charge. Note :- (i) Contractor's quoted rate shall be deemed to include to provide ladder, transport, tools and eqpt for pruning the branches. (ii) The complaint shall be done within one day after intimation by JE E/M / Engineer -in- charge on phone call, whats app msg or through letter failing which penalty of Rs 500/- per day per complaint will be levied on contractor. (iii) Restreching of conductor will be measured and paid separately.
S&F LT cable sleeves with colour coding (Red, Yellow, Blue and Black) suitable for 1100 volt grade 3 ½/4 core XLPE, armoured, aluminium conductor of cable size 10sqmm to 25 sqmm all as specified and directed by Engineer-in-Charge ( Note :- Sleeves length shall not be less than 450mm for each phase).
All as per Srl item No 66 above but cable size 35sqmm to 50 sqmm.
All as per Srl item No 66 above but cable size 70sqmm to 95 sqmm 3 ½ core
M& L for magnesium sulphate for using in earthing all as specified and directed by Engineer-in-charge.
A Schedule of Credit for old/ unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
kailu construction co
HARPAL ENGINEERS AND BUILDERS
M/s. Aggarwal Engineers
dinesh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .