Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC A 9 117 KALYANI PO KALYANI KALYANI NADIA WEST BENGAL 741235 | NADIA | WEST BENGAL | 741235 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹41.0 L+₹64,472 (1.60%)Rejected-Finance MAKARDHA PO MAKARDHA PS DOMJUR BANERJEEPARA WEST BENGAL 711409 | HOWRAH | WEST BENGAL | 711409 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹41.4 L+₹1.0 L (2.53%)Rejected-Finance 16 APC SARANI WARD NO 30 DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 WB | SILIGURI | DARJEELING | WEST BENGAL | 734004 | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹41.5 L+₹1.1 L (2.77%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹41.7 L+₹1.3 L (3.29%)Rejected-Finance | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
27 Sept 2022, 6:00 pmClosed
GE AF BAGDOGRA
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
REPAIR/REPLACEMENT OF WATER LEVEL INDICATORS, CLEANING OF RCC OH TANK, UG SUMP AND CONNECTED WORKS AND REPAIR/REPLACEMENT AND COMPREHENSIVE MAINT TO EQPT AND CONNECTED ITEMS AT SWIMMING POOL, STP AND PUMP HOUSE BUILDING AT 20 WING AFS BAGDOGRA UNDER
2022_MES_547353_1
8446/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Bagdogra
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Bagdogra
₹78,000
Yes
21 Oct 2022
2 Sept 2022
28 Sept 2022
2 Sept 2022
27 Sept 2022
20 Sept 2022
Amount
Taking down unserviceable Raw sewage non clog pump set from foundation and transportation to work shop for repairing from sewage treatment plant to contractor work shop for carry out necessary repair work to pump set submersible and transporting it back to site of water supply installation of AF Stn area.
Dismantling and rewinding of Raw sewage non clog pump set of any make and capacity as mentioned below existing size and gauge of PVC insulated single core copper winding wire submersible including all insulating material of make a approved:- (a) Capacity 10 HP at STP Phase-III. Note:- The retrieved burnt copper winding wire shall be handedover to store and necessary RV obtained.
All as per item No 2 above, but Capacity 7.5 HP at STP Phase-III.
All as per item No 2 above, but Capacity 5 HP at SLP Phase-I.
Supply and replace the following spares for 5 to 10 HP non clog Pump set:- (a) Impeller.
(b) Shaft sleeve.
(c) Ball bearing 6305.
(d) Ball bearing 6308.
(e) V belt B56.
Lifting of suction pipe with the help of chain pulley arrangement at STP Phase-III and SLP Phase I and refixing after replacing unserviceable Foot Valve 100 mm dia as directed by Engr-in-charge.
All as per item No 10 above, but GI pipe heavy duty 100 mm dia for column pipe.
Cleaning of slush deposited in the sewage collection sump by the help of supply of jet water and sewage lifting pump complete all specified and as directed by Engr-in-charge.
Taking down unserviceable Air blower of capacity 3 HP from foundation and transportation to work shop for repairing from sewage treatment plant to contractor work shop for carry out necessary repair work to pump set submersible and transporting it back to site of water supply installation of AF Stn area.
Dismantling of air blower, servicing and replacement of unsv parts and refitting the same of 3 HP capacity including testing complete all as specified and as directed.
Lifting and taking out complete submersible pump set 12.5 HP alongwith the column pipes with the help of chain pulley block from borewell well after disconnecting electrical connections from panel, disconnecting from suction and delivery pipe lines, disconnecting column pipes, testing electric motor to ensure its actual condition, separating pump & motor from coupling, reassembling and lowering pump & motor into bore well complete, connecting, testing and commissioning alongwith connected items such as MS column pipe, cable, re-fixing after receiving repaired and tested submersible pump with new nuts & bolts, rubber packing with proper alignment and making electrical connection, binding of cable with column pipe with nylon rope complete including testing all as specified.
Transportation of submersible pump sets 3 phase any make and capacity 12.5 HP from pump house to contractor work shop for carry out necessary repair work to pump set submersible and transporting it back to site of water supply installation of AF Stn area.
Dismantling of submersible motor any make and any capacity 12.5 HP and reassembling complete after carry out necessary repair work & testing complete for smooth working to entire satisfaction of Engineer in charge. (Note: New parts/components to be replaced shall be measured and paid separately under supply only.)
M&L for rewinding of submersible motor of Capacity 12.5 HP 3 phase 400/415 Volts any make and capacity existing size and gauge of PVC insulated single core copper winding wire submersible including all insulating material of make a approved complete all as specified. Note:- The retrieved burnt copper winding wire shall be handedover to store and necessary RV obtained.
Supply only upper and lower housing bushes of any material complete suitable for 12.5 HP complete all as specified and directed.
Supply only Impeller suitable for 12.5HP complete all as specified and directed.
Supply only stainless steel bushes each set suitable for 5HP to 15 HP submersible motor complete all as specified and directed.
Supply only 'O' ring kit and oil seal kit suitable for any capacity complete all as specified and directed.
Repair of bowl bush of housing by proper machine work of housing and pump soft & replacement of bowl bush for 5 HP to 15 HP complete.
Supply only rubber packing 20mm thick consisting of 8/6" holes for 80 mm to 150 mm dia column pipe complete all as specified and directed.
Jointing the submersible cable by jointing kit of suitable size by means of jointing material & making the leak proof jointing complete all as specified and directed by Engineer-in-Charge.
M&L for Taking out existing filter media like sand, gravel & ferminex from filtration plant of capacity 10,000 gallon per hour including soda & Alum Pots & removing from site and cleaning the internal surfaces of filtration plant with soda & Alum Pots with using PVC/Steel wire brushes to remove all scales, iron particles and finally clay & other foreign particles with clean water complete all as specified and as directed. Note:- The serviceability of filter media shall be decided by the BOO order by GE. Serviceable material shall be reused and unserviceable material should be disposed of out side MD land. Rate quoted for the item shall included for the same . Payment in RAR/FB will be made only after approval of BOO.
Taking out existing unserviceable PVC nozzles and Supply and fix new PVC double deck type PP strainer nozzle of size 10mm to 15mm (3/8” to ½” inch) dia, push type complete all as specified and as directed. Make: RMCO/ASHFORD or equivalent.
M&L for preparation of old painted internal steel surfaces of Filtration plant shell painting with one coat of black bituminous paint suitable for drinking purpose of area exceeding 10 cm in width or girth not otherwise described complete all as specified and as directed.
M&L for preparation of old painted external surface of Filtration Plant shell painting with first quality of synthetic enamel (gray shead) paint exceeding 10 cm in width or girth not otherwise described complete all as specified and directed.
M&L for packing of following sizes of new filter media in layers of approved quality obtained from ‘Barakar River’ complete all as specified and as directed:- Gravel of size 12 mm to 25 mm.
All as per item No 30 above, but Gravel of size 6 mm to 12 mm.
All as per item No 30 above, but Gravel of size 3 mm to 5 mm.
All as per item No 30 above, but Sand of size 16/30 mesh.
M&L for packing of chemical of ‘Feriminex’(MNO2) catalytic agent of size 1/16”x1/32 inches in layers complete all as specified and as directed.
Taking water sample for chemical analysis test for portability of water from approved Govt lab like National Test house Kolkata /RV Bridge Kolkata complete all as specified and as directed.
Replacement of unserviceable water pressure gauge with new pressure gauge capacity 7 kg/sqcm to 10 kg/sqcm complete all as specified and as directed. Make : RMCO/OASIS.
Taking out old unserviceable rubber gasket from position with taking out of nuts, bolts etc and S&F New rubber gasket of size 75cm outer dia, 3mm thick rubber sheet of approved quality fixed with suitable size & dia mild steel machine made nuts, bolts & washers of required size & numbers complete all as specified and as directed. (Note:- Nuts, bolts & washers shall be measured & paid separately under relevant item here-in-before).
All as per above item No 37 above, but of size 45cm outer dia.
S&F mild steel machine made nuts, bolts & washers of size 15mm(5/8”) dia and 75mm (3”) long or nearest suitable sizes for top cover and side cover of Soda /Alum pot complete all as specified and as directed.
Taking down old unserviceable Butter fly valve 100 mm from existing position and supply and fixing Butter fly valve lever operated CI 100 mm dia including necessary joints by means of bolts, nuts washers and rubber gaskets complete all as specified and as directed. Make:- KIRLOSKAR/BIR/VENUS/RMCO or equivalent as approved by GE.
Supply and laying the GI water tubing heavy grade 80 mm including new threading by lathe for fixing heavy duty socket suitable for column pipe including taking down complete all as specified and as directed.
S&F MS Socket 80 mm bore pipe, heavy duty suitable GI pipe 80 mm dia heavy duty column pipe including taking out unserviceable one complete all as specified.
S&F MS Socket 100 mm bore pipe, heavy duty suitable GI pipe 100 mm dia heavy duty column pipe including taking out unserviceable one complete all as specified.
S&F Semi Automatic Star-Delta starter in sheet metal enclosure type MK with single phase protection feature suitable for motor rating AC-3 phase, 415V, 10 HP , 6-10 A range all complete as specified and directed. Make- L&T -CAT SS96255POVO or C&S, Seimens.
Taking down old unserviceable air release valve form existing position and S&F air release valve double action chamber to conforming IS-14845 of size 150 mm bore complete all as specified and directed.
Taking down old unserviceable non return valve form existing position and supply and fixing cast iron non return valve conforming to IS - 5312, PN-1.6 including necessary joints by means of bolts, nuts washers and rubber gaskets complete all as specified for 150 mm bore of pipe. Make -KIRLOSKAR /RMCO/BIR.
Taking down old unserviceable sluice valve from existing position and supply and fixing cast iron sluice valve conforming to IS - 14846 PN 1.6 clockwise dosing with flanged ends and iron wheel including necessary joints by means of bolts, nuts washers and rubber gaskets complete all as specified for 150 mm bore pipe. Make- KIRLOSKAR/BIR/ RMCO/VENUS or equivalent.
All as per item No 47 above, but for 100 mm dia complete all as specified and directed.
All as per item No 47 above, but for 80 mm dia complete all as specified and directed.
S&F Vacuum hose pipe 38 mm dia suitable for suction sweeper swimming pool including taking down complete all as specified and as directed.
Excavation in trenches in soft / loose soil n.exc 1.5 mtr wide n.exc 1.5 mtr deep getting out soil complete all as specified and directed.
Returning filling in including spreading leveling well ramming in layers n.exc 25 cm thick in a layers all as specified and as directed.
Removing excavated material (Soil) n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed.
Taking up or down GI water tubing 80 mm dia including fitting connections and cleaning tubing, fitting/ cutting threading of serviceable tubing for relaying and removal of unserviceable tubing all as directed by Engr-In- Charge.
All as per item No 54 above, but for 50 mm dia complete.
All as per item No 54 above, but for 40 mm dia complete.
All as per item No 54 above, but for 25 mm dia complete.
All as per item No 54 above, but for 20 mm dia complete.
All as per item No 54 above, but for 15 mm dia complete.
Re-fixing only old serviceable GI pipe incl fittings and connection in new or old position (Pipe obtained from item No 50 above ) of size 80 mm dia.
All as per item No 60 above, but for 50 mm dia complete.
All as per item No 60 above, but for 40 mm dia complete.
All as per item No 60 above, but for 25 mm dia complete.
All as per item No 60 above, but for 20 mm dia complete.
All as per item No 60 above, but for 15 mm dia complete.
Supply and laying the GI water tubing medium grade with all fittings in trenches all as directed 80 mm dia. MAKE: TATA /Jindal/Bansal or equivalent as approved by GE.
All as per item No 66 above, but for 50 mm dia complete.
All as per item No 66 above, but for 40 mm dia complete.
All as per item No 66 above, but for 25 mm dia complete.
All as per item No 66 above, but for 20 mm dia complete.
All as per item No 66 above, but for 15 mm dia complete.
Supply and laying/ fixing polyprolene random pipe (PP-R) PN 16 in three layer incl fixing of all fittings made out of PP -R as required for fixing to wall or laid in floor / ground all as specified and directed for 90 mm bore. Make:- SFMC/PRINCE/RELIANCE/SAVOIR-FAIR.
All as per item No 72 above, but 50 mm dia complete all as specified.
All as per item No 72 above, but 40 mm dia complete all as specified.
All as per item No 72 above, but 25 mm dia complete all as specified.
All as per item No 72 above, but 20 mm dia complete all as specified.
S&F in repair Gun metal gate valve (screwed) with iron wheel head, screwed both ends for iron / PPR pipe of size 50 mm dia. Make: Zoloto/Leader/Scud/Kirloskar.
All as per item No 77 above, but 40 mm dia complete all as specified.
All as per item No 77 above, but 25 mm dia complete all as specified.
All as per item No 77 above, but 20 mm dia complete all as specified.
All as per item No 77 above, but 15 mm dia complete all as specified.
M&L for repairs to GI pipe line by cutting the damaged portion, threading both sides, insertion of same bore GI long screw, testing for leak proof in position all as directed. Note : Excavation & earthwork shall be measured separately.
S&F GI flange for 80 mm bore pipe, medium grade with suitable size nuts and bolts and double washers including 6 mm thick rubber gasket including taking out unserviceable one complete all as specified.
M&L for run lead joints in position for cast iron spigot and socket ends for size 200 mm dia.
All as per item No 84 above, but 150 mm dia.
All as per item No 84 above, but 100 mm dia.
All as per item No 84 above, but 80 mm dia.
M&L for seven stage cleaning and sterilization of inside overhead reservoir capacity 50000 gallons through bacteriological treatment by using oxidizing agent such as TERBAC GS ,TERBAC G-65 and Ultra violet ray or equivalent complete all as specified and as directed by Engr-in -Charge. 1. First stage is to drain out the water by using wash out valve or high capacity dewatering system. 2) Second stage is cleaning all the algae formation inside the tank by using TERBAC G 10 a laboratory tested branded chemical of the company and scrubbing the walls of the tank. 3) Third stage is fresh water cleaning by high speed jet pump. 4) Fourth stage is first bacteria screening is decertification by using TERBAC-G5 a Govt laboratory certified branded halogen compound 5) Fifth stage is cleaning the floor of water tank by industrial vacuum cleaner. 6) Sixth stage is the second baccterio screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria. 7) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC G-65. Note- (i) Cost of staging and necessary working platform shall deemed to be included in quoted rate (ii) Contractor shall ensure necessary safety precaution and insurance of working during execution (iii) The quoted rates shall be deemed to be included the cost of writing date of cleaning ,due date and capacity of tank on the wall surface of the tank.(iv) Contractor shall provide the sticker mentioning the date of cleaning ,Name of site & certificate conforming the completion of sterilization of water tanks. Location -PH-17 Tech Area , PH-01-DGCA, PH-16 Phase I and PH-10 Ph-II.
All as per item No 88 above, but for tank capacity 40000 Gallons (PH-15 Phase III).
All as per item No 88 above, but for tank capacity 25000 Gallons(PH-08).
All as per item No 88 above, but for tank capacity 20000 Gallons (PH-07 Officer Mess, PH-14 SRE, PH-18, 273 SU, PH-19 46 WEU).
M&L for Cleaning of Steel Water Storage Tank of capacity 10,000 gallons thoroughly removing mud, grits etc. from the tank by following method:- (a) Removing all dirt, mud with the help of containers manually from inside to the water storage Tank, then scraping to walls inside/out side complete as directed. (b) Washing with clean water after scraping with wire brush in side and out side removing mud and spoil to a distance n.exc. 50 mtrs. (c) Washing with clean water and bleaching powder including scraping wire brush on walls & removing mud and grits & deposits etc properly. (d) Repair/Replacement to all inlet/out lets of tank with a reqd size of MS/GI Pipe as directed including as reqd welding work etc complete making leakage proof as directed. (MS/GI Pipe if reqd, it will be measured and paid separately). (e) Preparation of old painted surface of steel tank and painted with two coat of sky blue paint (1st quality) in existing position all as specified and directed. Note: Consumption of bleaching powder for cleaning of tank shall not be less than 10 Kg.
M&L for auto level controller (model ALC MK-I) including probe unit, five stage magnetic sensors concealed in S S casing of reqd length, controlling box including system incorporate with stage signal, high & low level alarm, pump automation etc. all complete (without wire from probe unit controller) complete all as specified and as directed.
S&F PVC insulated armoured and PVC sheated heavy duty electric cable with copper conductor 1100 Volt grade of cross sectional area 5 core 1.0 Sqmm laid in trenches passing through pipes/ducts including testing complete all as specified and as directed.
Taking up CI 150 mm water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead.
Supply and laying cast iron pipe with spigot and socket end centrifugally cast, class A of size 150 mm dia in trenches complete all as specified and directed. Make:- TATA/Electrosteel/JINDAL.
Taking up CI/DI/MS 100 mm water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead.
Supply and laying MS pipe with flanged end heavy duty of size 100 mm dia in trenches complete all as specified and directed. Make:- TATA/Electrosteel/JINDAL.
Supply and laying centrifugally cast spun ductile iron (DI) spigot & socket end pressure pipe 100 mm dia of K-9 including tyton ring rubber joint of best quality in trenches complete all as specified and directed. Make:- TATA/Electrosteel/JINDAL.
Boring of road for laying of pipe not exceeding 90 cm below ground level all complete as specified and as directed.
M&L for cement concrete type C2, 1:3:6 (40 mm graded aggregate) for making good to disturbed surface of road etc. all as specified and as directed.
M&L for attending pipeline breakdown of CI /DI pipe of 80 mm dia by making lead joint with lead and spun yarn and moulding clay including taking up/down pipe using chain pulley or rope and excavation in any type of soil including returning filling and removal of soil and testing of pipe line complete all as specified and directed.
All as per item No 102 above, but 100 mm dia complete all as specified and directed.
All as per item No 102 above, but 150 mm dia complete all as specified and directed.
All as per item No 102 above, but 200 mm dia complete all as specified and directed.
M&L for Construction of valve pit of size 120x 120 x 120 cm (Internal dimension) incl necessary earth work and MS sheet 2 mm thick cover with angleiron frame 40 x 40x 6mm including dismantling of valve pit with cover all as specified and directed.
Taking down old unserviceable sluice valve from existing position and supply and fixing cast iron sluice valve 200 mm bore ,brass spindle conforming to IS -14846 clockwise dosing with flanged ends and iron wheel including necessary joints by means of bolts, nuts washers and rubber gaskets complete all as specified for pipe. Make: KIRLOSKAR/BIR/VENUS/RMCO or equivalent as approved by GE.
M&L for run lead joints in position for cast iron spigot and socket ends for size150 mm dia complete all as specified and directed.
M&L for Cast iron bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (flange sockets or socket and spigot) collars, caps and plugs of size up to 200 mm bore complete all as specified .
Drilling and tapping of CI water line 15 mm to 20 mm for branch connection for chlorine dosing system complete all as specified and as directed.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
M/S Banerjee construction co
SUNIL DAS AND CO
RABI BANIK
HALDER ENTERPRISERS
M/S SUNNY ENTERPRISE
M/s Prakash Traders
SREE SWAPAN KUMAR GHOSH
SHRI P P SHARMA
M/S BENGAL ENGINEERING ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .