Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹25.9 L+₹93,038.50 (3.73%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹26.4 L+₹1.5 L (5.94%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹53,840
Closing Date
17 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2022_MES_553199_1
GE(S)/PAT/T-44/N/2022-23
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE(South) Patiala
₹53,840
Yes
13 Dec 2022
20 Sept 2022
19 Oct 2022
20 Sept 2022
17 Oct 2022
4 Oct 2022
20 Sept 2022 - 27 Sept 2022
Amount
Surface dressing not exc 15 cm deep in soft/loose soil.
Excavation in trenches not exc 1.5 mtr wide and not exceeding 1.5mtr depth for foundation in soft/loose soil & getting out.
M&L for PCC (1:4:8) type D2 using 40mm graded aggegate as in foundation.
M&L cement concrete in foundation type B 2, 1:2:4 ( 40 mm graded stone aggregate) as in filling and mass concrete.
M&L brick work in CM (1:6) with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius complete all as specified.
M&L for brick work in cement mortar (1:4) using sub class 'B' bricks staight or curved on plan but in half thick brick walls
Returning filling in incl spreading, levelling, watering & well ramming in layers not exc 25cm thick for soft/loose soil complete all as specified.
Removing excavated material 250 m but n.exc 50m and depositing where directed at a lavel .exc 1.50 mtr above the starting point.
M&L 40mm thick 1.2.4 type B-0 Damp proof course to horizontal or vertical surfaces including necessary formwork compleate all as specifiede and directed.
S&F Factory made steel windows box type using ERW hollow 'P' section comprising double frame for glaged and gauged skelton shutters jointed interally with flat iron 40x4mm complete including grill of 8mm square bar, fixed horrizontally @ 10cm centre to centre, hinges, handle tower bolts,lugs etc all as shown on drawing noTD-219 (c) sheet 1/3 to 3/3 and TD-220 (c) sheet 1/3 to 3/3 as applicable complete (Note;- (i)for the purpose of measurement& payment double shuttre with frame shall be considered as one unit.)
M&L for reinforcement cement concrete 1:2:4 type B-1 (20mm graded crushed stone aggregate) in lintels beams, cantilevers, bressummers complete all as directed by Engineer-in-charge.
M&L for RCC 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in sun shades/Chajjas/ Fascias/ Lintelbeams/etc including necessary form work and complete all as specified and as directed.
Use and wste of formwork to edges of concrete flats, floor and roofs n exc 20 cm wide
Use & waste of formwork to sides and soffits of floor and roof beams ,lintels beam ,cantilevers ,shelves including supports ,overhangs and similar work , for rough finished flat surfaces all as directed by Engr-in-Charge.
M&L for Mild steel TMT bars 10mm dia & over cut to length, bent to shape required incl cranking bending with0.9 mm dia MS wire (annealed) not less than0.9 mm dia or securing with clips.
M&L for Mild steel TMT bars 5mm dia and over upto and incl 10 mm dia in stirrups, spacers and binders.cut to length, bent to shape required incl cranking bending with0.9 mm dia MS wire (annealed) not less than0.9 mm dia or securing with clips.
M&L for Sheet glass ordinary quality 4 mm thick and glazing with oil puttly or wooden beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
S & F Wire netting of galvanised steel wire 1.40mm dia and size of mesh 25mm fixed with wooden beds tinned tacks of wire staples
M&L for hardcore of gauge n.exc. 63 mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface using broken stones or boulders, complete all as specified and directed.
M&L for rectangle / Squar /circular hollow section as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for structural purpose, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165)
S&F mild steel plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections complete all as specified and directed.
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws as specified
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws as specified.
M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed.
M & L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished complete all as specified and directed Note : Water proofing compound shall be measured and paid saparately under item .
Supply only integral water proofing compound ISI marked.
M&L 10mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed.
M&L 100 mm th PCC 1:4:8 type D2 ( Using 40 mm graded stone agg.)as in sub base of floors.
M&L 100 mm thick (1:2:4) Type B-1, Plain cement concrete with using 20mm graded aggregate as in hard standing etc finished with without using extra cement , complete all as specified and directed.
M&L for Machine pressed precast concrete inter locking paver block any shape and size made of M-40 grade concrete (with grey cement and no pigment) of 80mm thickness laid over 25mm thick (compacted) fine sieved sand complete all as specified and directed.
M&L for Machine cut Kota stone slab flooring 20mm (+2mm) thick laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Factory made steel windows or ventilators, fixed type with glazing bars complete all as specified.
M&L 50 mm thick plain cement concrete 1:3:6 mix, type C-2 using 40mm graded stone aggregate as in plinth portection, finishing the surfaces even and fair without using extra cement complete all as specified and directed.
Preparation of new plastering surfaces of walls and applying two coats of cement base paint over one coat of cement primer complete all as specified.
M & L for two coat of distemper with oil emulsion on wall including preparation of new plastered or unplastered surface including washing rubbing down and stoping of distempered and painted surface complete all as specified.
M&L for Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification and drawing.
M&L for Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per manufacturer’s instructions.
M&L for 100mm size PVC butt hinges complete all as specified and directed
M&L for 150mm size PVC handles complete all as specified and directed.
M&L for 200mm long PVC tower bolt complete all as specified and directed.
S&F Fe290 (Gde E-165) Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening.
M&L for Steel water tubing medium grade 15mm bore galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
M&L for Steel water tubing medium grade 20mm bore galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F 450mm long PVC connection of approved quality with brass check nuts at both ends for 15mm bore pipe complete all as specified and directed.
S&F Rotational moulded polythene water storage tanks, double layered (Cylindrical vertical with closed top) of capacity 1000 lit, hoisted and fixed in position all as specified and directed
S&F Ball brass valve, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to dia of pipe 20mm complete all as specified and directed.
S&F Stop valve cast gate valve copper alloy screwed down high pressure with crutch or iron wheel handle screwed both ends for iron pipe of bore 20mm fixed complete all as specified and directed.
S&F Angle stop cock fancy type, brass chromium plated with CP wall cap 15 mm bore complete all as specified.
M&L for anti skid coloured pressed ceramic floor tiles of minimum size 300X300 mm 8 to 10mm thick in flooring etc set and jointed in neat cement lurry and pointed in white cement to match over and including 20mm thick screed bed in CM (1:4) laid over in complete all as specified and directed.
M&L fo 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates in complete all as specified and directed.as in floor base complete all as specified and as directed.
M&L for Coloured glazed ceramic tiles (300 x 600 mm) x 7mm or (450X350 mm)X7mm thick as in vertical surfaces such as skirtings, dados etc jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick back coat in CM (1:4), in complete all as specified and directed.
M&L for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors/walls as soil pipe all as specified.
M&L for 110mm dia PVC (SWR) bends with access door any radius all as specified.
M&L for 110mm dia PVC (SWR) junction double, (double T), equal or unequal radius all as specified.
M&L for 110mm dia PVC (SWR) vent cowl radius all as specified.
M&L for 110mm dia PVC (SWR) 'P’ trap radius all as specified.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified.
S&F Flushing cistern low level, PVC 10 lit capacity syphonic action type, valve less with inlet ball valve complete all as specified.
S&F brass Chromium plated Bib taps fancy type 15 mm dia bore type with cruth handle, screwed down, screwed for iron pipe all as specified and directed by Engineer-in-Charge.
S&F 15mm dia pillar taps fancy type Chromium plated screwed down high presswure with or without lettered 'Hotor Cold' with long screwed shanks and fly nuts ,screwed for iron pipe complete all as specified and directed by Engr-in-Charge.
M&L for broken brick boulders hardcore of guage n.exc 63mm deposited spread and levelled in layers under plinth protection.
S&F Viterous china ware wash down water closet Orrisa pattern size 580x440mm white with integral foot rests including connection to traps and to flushing pipe, anti syphonage pipe complete fixed in repair.
M&L for Reinforced concrete pipes, class NP2 laid and jointed complete with collars bore in pipes 150mm all as specified and directed
M & L for cement concrete bed (1:3:6) type C-2 using 40mm graded stone aggregate to drain pipe of 150 mm bore including packing under hunching against the site of pipe after they are laid and tested.
S&F Vitreous china premium/1st quality Wash basin (under counter), white size 580x430mm incuding all accessories as recommended by manufacturer complete fixed in position in all respect as per manufacturers instructions and all as sapecified and as approved By Accepting Officer.
M&L for reinforcement cement concrete (Normal mix )1:2:4 Type B1 (20mm graded aggregate) as in slab support on wall , deck slab and in shelves and the like.
M&L for TMT bars 6 to 8mm dia and over mild steel as in reinforcement, cut to length bent to shape required including cranking and bending with MS wire (anealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M & L 20mm thick black colure granite Machine cut as in border (Patti) laid over cement screed 15mm thick in CM 1:4 over and jointed with gray cement slurry mixed with pigment including rubbing and polishing complete all as specified and directed.
M & L for precast RCC 1:2:4, type B-1 as in man hole cover slabs using 20mm graded stone aggregate and set in CM 1:4 including necessary form work all as specified and directed. Note : Reinforcement shall be measured and paid separately under item No. 70 below
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. . Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.iii) Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost.
All as per item No 71 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 71 above, but for one 3/5 pin socket outlet 5 Amp on same board.
All as per serial item No 72 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
M&L for Modular switch 1 way 6A, 1 module type all as specified and directed.
M&L for Modular switch 1 way 16A, 1 module type all as specified and directed.
M&L for Modular Socket, 6A - 5 pin 2 module type all as specified and directed.
M&L for Modular Socket 6A/16A - 2/3 pin 2 module type all as specified and directed.
Supply and Fixing LED light fittings 1 x 20 Watt, 220 V, AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of size from ceiling rose complete.
Supply & fix in replacement of LED 10 Watt, 2 feet long, Cool day light with NEO Batten10 W 6500K having high efficiency Cat No. LHEXACP7IN1W010. Make -Havells. incl necessary electric conection complete all as specified.
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Material and labour for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 18 watts for batten fitting, complete all as specified.
Supply and fix LED Lamp LED new Adore 9W WW Ball Lamp LHLDERHEMD 8X007, 9 watt.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires 230 Volts including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified by Engr-in-Charge.
S & F SPN DB suitable for MCBs of single pole and neutral 8 way as per IS - 8623, IP-54 protection, double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) Dismantling of existing sheet metal box will be deposited to MES. (iii) MCB'S shall be fixed with copper wires FRLS 1.5 Sqmm incl appropriate size of Cooper thimbles.
Supply and fix in replacement of MCB SP up to 6-32 Amp 'B' seriesall as specified and directed.
Supply and fix in replacement of MCB SPN 6-32 Amp 'B' series complete all as specified and directed.
Supply, laying, testing and commissioning of cable LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core confirming to IS specification complete all as specified and as directed .
All as per item No. 88 above but 6 Sqmm 2 Core.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
S & F new generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with suitable dia light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed.
S&F Geyser (water heater) vertical storage type 240 volts, 2000 Watt, BEE rating, 5 Star , water proof IPX-4 Pprotection having adjustable knob for temperature settings, copper cell of 50 Ltr capacity incl cost of anchoring arrangement (nut & bolts) to the wall, corded copper electric cable, arrangement for protection from rain by providing angle iron, green fiber sheet of suitable size & thickness, fasten by nut & bolts to cover geyser all as specified and directed.
m/s panchmukhi builders
NARINDER KUMAR SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .