Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.7 L+₹60,800 (12.0%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹7.4 L+₹2.4 L (46.7%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹8.0 L+₹2.9 L (57.5%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹8.3 L+₹3.2 L (63.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
4 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CIF K
AGE I CIF K
REPAIR AND MAINT OF LT EXTERNAL ELECTRIFICATION OF 663 R AND O UNDER AGE (I)CIF(K)
2020_MES_398329_1
AGE (I) CIF(K)-27/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHALATENG
Refer Tender documents
8 documents required · 8 mandatory
₹500
AGE I CIF K
₹19,000
Yes
16 Feb 2021
26 Nov 2020
6 Jan 2021
26 Nov 2020
4 Jan 2021
21 Dec 2020
60 days
Amount
Dismantling and removing existing old/damaged/US ACSR conductor of any size/type from over head lines on existing poles including binding with insulators safely etc complete and making proper roll of ACSR conductor for reuse or schedule of credit and also insulators safely for reuse/schedule of credit , complete all as specified and directed by the Engineer-in-Charge . Note:- ACSR Conductor and Insulater with supporting clamp of any type should be kept seperately for reuse or schedule of credit as directed by Engr in charge.
Dismantling existing old/unserviceable galvanized iron steel wire drawn straight horizontal as continuous earth wire on existing LT poles of any size and making roll for reuse or schedule of credit , complete all as specified and directed by the Engineer-in-Charge .
Taking down old existing any type of cross arms, supports, channels, Clamps, flat irons etc fabricated from MS sections of any size and any type including nuts, bolts, washers of any shape/size, complete all as specified and as directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable , complete all as specified and as directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XPLE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm, 3.5 core in trenches, through pipe, under culvert or in air including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by Engineer-in-Charge.
Providing and laying plain cement concrete 1:2:4, type B-1, using 20mm graded crushed stone aggregate, as in coping around poles including necessary form work and fair finishing of exposed surfaces without using extra cement , complete all as specified and as directed by the Engineer-in-Charge.
Dismantling existing unserviceable stay assembly and Supply and fixing in old and new places Stay assembly using GI stay rod of 16mm dia complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part I, with galvanized steel stranded wire of size specified, complete all as specified and as directed by the Engineer-in-Charge. Note:- Cost of necessary insulators, stay clamps, excavation and concrete, earth work and PCC shall be deemed to be included in the rate quoted.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire,4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009), complete all as specified and directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Replacement of existing LT Spacers with new LT Spacers 4 Ways,made out of PVC material and suitable for working on 1100 volts, complete all as specified as directed by the Engineer-in-Charge.
Replacement of existing LT Spacers with new LT Spacers 2 Ways,made out of PVC material and suitable for working on 1100 volts, complete all as specified as directed by the Engineer-in-Charge.
Replacement of existing worn out/over heated/multi jointed ACSR jumpers of LT overhead lines with PVC insulated 1100 volts cable of size 50 Sqmm , complete all as specified as directed by the Engineer-in-Charge. Note :- Length of one jumper shall be 1.5 mtr (appx)
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 100 Amps, 35 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 160 Amps, 35 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 200 Amps, 36 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Galvanized iron tubing 50mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables and including taking down/out old existing pipe, complete all as specified and directed by Engineer- in-Charge.
Disconnecting the windings of loose overhead conductors of LT lines from insulators and restringing the same for proper sag and rewinding including aluminium winding wires, tapes etc and jumpering for any type of conductor , complete all as specified and directed by Engineer- in-Charge. Note - Conductor wise running metre work will be measured for payment purpose .
Painting of steel tubular pole 9 metre long including cross arms,channels,angle iron support,bracing ,clamps,GI Bracket etc. by applying two coats of aluminium paint superior quality of approved make after scraping/brushing and cleaning the rust on pole and cross arms etc. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 metre from ground level will be painted by alternate layer of black and yellow strips of 30 cm each with synthetic enameled paint, complete all as specified and directed by Engineer- in-Charge.
Numbering of poles with synthetic enameled black paint in yellow circle of 150mm dia complete all as specified and directed. Note:- The numbering shall be hand written only. Stencils embossing shall not be allowed and size of letter shall be 50 x 10 mm (height x width ).
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays etc. and getting out in any type of soil, complete all as specified and directed by the Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection, complete all as specified and as directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connections , nominal cross section 10 sq mm, 2 core ,including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Cutting of tree branches touching or leaning over overhead power lines and removing of cut tree branches from the site, complete all as specified and as directed by the Engineer-in-Charge.
Feeder piller box, out door type, fixed with double door front side made out of 2.0 mm thick MS plain sheet, front side openable type, fixed with hinged and knob, dust, weather & vermin proof cubical type of size not more than 1.20 x 0.80 x 0.60 metre and mounted on angle iron 35 x 35 x 6mm thick, 0.40 metre long - 04 Nos welded with box for fixing in PCC with and including PCC 1:2:4 work, dully painted with two coats of synthetic enamel paint over a coat of red oxide primer complete with and including bus bar strips suitable for three phase and neutral with Aluminum bus bar of four pole of capacity 800 Amp rating fixed over the porcelain insulator with provision for fixing of MCCB, 4 pole as incomer one No with incoming cable entry/connection and 2 to 4 Nos as outgoing MCCBs with outgoing cable connection/entry as per site requirement, complete all as specified and as directed by the Engineer-in-Charge. MAKE :- HAVELLS/HENSEL/TRICOLITE/L&T/ELECTRICFIELD Note :- Drawing of panel shall be got approved from Engineer-in-Charge before placing the order for the panel for fabrication. MCCB and cables required will be measured and paid seperately under appropiate item of BOQ.
PVC flexible corrugated pipe of size 50mm dia with clamp, complete all as specified and directed by the Engineer-in-Charge.
PVC flexible corrugated pipe of size 20mm dia with clamp , complete all as specified and directed by the Engineer-in-Charge.
Replacement of existing bus bar chamber with new bus bar chamber 63 Amps, 4 pole, 440 volts with sheet metal enclosure, complete all as specified and directed by the Engineer-in-Charge. Make : - Havells/Bajaj/Indoasian/ABB/Siemens/Schneider
New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 LED street light fitting 40/45 watts with heat resistant toughned glass complete with all accessories and making of electrical connection with and including three core flexible copper conductor cable of suitable size, including taking down existing old unserviceable fitting, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havells Cat part No. ENDURAPEARLNEOSL40WLED 757PASYTOPC or equivalent in Phillips/Bajaj/Crompton
Note :- An amount of Rs. 33,300.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S YATTOO CONTRACTORS
FG CONSTRUCTION
M/S B A Traders
M/S S. D. BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .