Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC 15 GURU RAM DASS COLONY MITHAPUR JALANDHAR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹42.9 L+₹89,494.14 (2.13%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹43.1 L+₹1.1 L (2.59%)Rejected-Finance PLOT NO 881 PREM NAGAR NEW PLOTS JAMMU JAMMU JAMMU KASHMIR 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹43.9 L+₹1.9 L (4.50%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹44.6 L+₹2.6 L (6.26%)Rejected-Finance 65 DEEP NAGAR BIRRING ROAD JALANDHAR CANTT PB | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹51.7 L
EMD Value
₹1.0 L
Closing Date
2 Aug 2023, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt PIN-144005
Please refer tender documents
2023_MES_600693_2
8323/04/E8
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Class C Category a(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹1,000
Garrison Engineer West Jalandhar Cantt
₹1.0 L
Yes
29 Sept 2023
30 Jun 2023
9 Aug 2023
30 Jun 2023
2 Aug 2023
21 Jul 2023
Amount
Dismantling of brick tiles single layer/old tar felt any type as in roof covering complete all as specified & directed.
Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) and removing the surplus soil out of MoD land all as specified & directed.
M&L for Roughening surfaces of old concrete floor by wire brushing, picking, sweeping clean and washing down with water to remove dust, etc.
M&L for Brushing neat cement slurry with 3.0 kg of cement per sq. metre over cleaned concrete surfaces all as specified and directed
M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed.
M&L, for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in coping of parapets and or roof kerbs on roof chamfered on edge incl troweling slightly complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stil green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and as directed. Note :- Water proofing compound shall be measured separately.
Supply only Liquid water proofing compound complete all as specified and as directed of as per manufacturer instruction.
M&L for applying evenly a tack coat of industrial bituminous 85/25 @ 1.20 Kg per squqre mtr including cleaning surfaces.
M&L APP based polymeric membrance minimum weight not less than 3.0 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150gms/sqm) land on primed surface by forced application( sealed by flame) with over lap of 15 cm complete all as specified and directed complete all as spd and directed. (Make: M/s Asian Paints Ltd / M/s STP Ltd/ M/s Sika India Pvt Ltd)
M & L 40mm thick Brick tiles laid on bedding layer of CM 1;3 15mm thick and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement over APP membrane complete all as specified and directed.
M & L 40mm thk Brick tiles laid on bedding layer of CM 1;3 15mm thick and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement over APP membrane but except brick tiles complete all as specified and directed.
M&L for Flush pointing to brick tiles, laid flat in roofs complete all as specified and directed.
Taking up or down existing steel 15 mm tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed
Taking up or down existing steel 20 mm tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed
Supplying and fixing, 15 mm jointing and testing galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall (including cutting chases for concealing the GI pipe and making good complete) or laid in floor complete all as specified and as directed
Supplying and fixing, 20 mm jointing and testing galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall (including cutting chases for concealing the GI pipe and making good complete) or laid in floor complete all as specified and as directed
Dismantling of water tanks exc 500 ltr and n.exc 1000 ltr capacity and removing from site complete all as specified and as directed
S&F 1000 ltr capacity rotational moulded polythene tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed
Disconnecting existing any size tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
S&F 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium weight 210 gms ), complete all as specified and directed
S & F in repair 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S & F in repair 15 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
Taking down cement plaster of any description any thickness /dado/Skirting/ including raking out joints hacking for key scrubbing down with water all as specified.
Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excluding precast concrete articles all as specified & directed.
M&L for Centering to brick, stone or concrete block arches of any shape, not exceeding 6 metres span (Note: For suppoting floor and roof slab and lintels/beams while dismantling brickwork and reconstructing the brick masonary crumple portion)
M&L for brick work with sub class 'B' old size bricks straight or curved on plan to any radius with old size brick thick walls built in cement mortar 1:6 all as specified.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan to any radius with old size brick thick walls built in cement mortar 1:6 but except brick all as specified.
M&L 0.63 mm Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specidfied and directed.
M&L for brick work in half brick thick walls built in cement mortar (1:4) using sub class ‘B’ old size bricks, straight or curved on plan to any radius complete all as specified.
M&L for Rendering 15 mm thick cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement all as specified
M&L for preparing surfaces new plastered surfaces of walls by applying two coats of oil bound distemper (Manually) with Birla wall care putty on plastered surface preparatory to distempering complete all as specified.
Complete removal of existing treatment of wall surfaces applying two coat of oil bound distempering (Manually) over one coat JK Birla putty all as specified and directed by Engr-in-Charge.
M&L for 15 mm thick cement mortar 1:4 on brick or concrete surface finished even and smooth without using extra cement all as specified
M&L for preparing new plastered or unplastered wall surfaces and applied two coat of cement base paint (Manually) over one priming coat all as specified and directed by Engr-in-charge.
M&L for complete removal of existing treatments on wall surfaces and applied two coat of cement base paint over one coat of primer all as specified and directed by Engr -in-charge.
M&L Plastering 5mm thick in cement mortar (1:3) finished even and smooth without using extra cement as on ceiling complete all as specified
M & L for preparation of new plastered surfaces of ceilings and applying three coats of white wash etc. complete all as specified and directed
M & L for preparation of Old plastered surfaces of ceilings and applying two coats of white wash etc. complete all as specified and directed
M & L for preparation of old plastered surfaces of walls and applying two coats of white wash etc. complete all as sepcified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) and disposal of rubbish outside MD land complete all as specified
M&L for non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm (600 x 600 mm) in floors set and jointed in neat cement slurry and pointed in white or colored cement to match over and incl 15mm thick bedding layer CM 1:6 complete all as specified.
M&L for non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm (600 x 600 mm) in skirtings etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match colour of tiles over and including rendering 10 mm thick cement mortar (1:4) complete all as specified and as directed
S&F glazed ceramic tiles 450x350x7mm thick as ion vertical surfaces viz dados, skirtings etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match colour of tiles over and including rendering 10 mm thick cement mortar (1:4) complete all as specified and as directed
M&L for non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (400 x 400 mm) in floors set and jointed in neat cement slurry and pointed in white or colored cement to match over and incl 15mm thick bedding layer CM 1:6 complete all as specified.
M&L for Machine cut kota stone slab flooring 18-20 mm thick over cement screed base 15 mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
M&L for Machine cut kota stone slab flooring 18-20 mm thick over cement screed base 15 mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab (Except stone) including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
M&L for 18-20 mm thick machine in cut kota stone slab (Single piece) for treads & landings of stair cases over and incl 15mm thick bedding layer CM 1:6 with pigments to match the shade of slab including cutting, rubbing and mirror/granite finish polishing complete all as specified and directed by Engr-in-Charge.
-Ditto- all as per previous item but on vertical surfaces such as skiting dado, riser etc over and incl 10 mm thick cement plaster in CM 1:4 rough finished surface to receive tiles
M&L Mirror polishing/grinding on Kota stone or terrazzo floors where ever required to give high gloss finish including beeswax polishing complete all as specified and directed.
Rounding/moulding to edges of Kota stone slabs, marble stone, granite stone slabs one edge, such as in steps, cooking platform , and other similar situations etc
Demolition of cement concrete (Unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level)
M&L 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggr) as in plinth protection/path finishing the surface even and smooth without using extra cement complete all as specified & directed. Note :- Plinth protection shall be laid in (1:20) slope. The concrete shall be laid at a stretch not exceeding 3 metre in length. Joint gap between adjoining slab, at corners and at junctions of walls shall not exceed 10mm in width and shall be sealed with mastic filling i.e. one part of bitumen 85/ 25 grade mixed with 3 part of sand. Top surface of concrete shall be finished even and smooth without using extra cement. Joints shall be provided at not more than 3 metre interval at corner and as junction of walls.
Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each all as specified.
Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area exc 1.5 Sqm but n exc 4.00 sqm each all as specified.
Supply and fixing steel window 1.25 mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises gauged skeleton shutter ERW sec 50mmx20mm and 1mm thick with two openable leaf consisting two Nos sash bars of T-section 20mmx3mm complete welded to frame with one verticle mulion of ERW box type T-section of size 60mmx25mm and 1.25mm thick incl cutting holes and making good dismantled portion PCC (1:2:4) type B-1 four Nos for each window) including following fittings welded to frame shutter: - (a) Hold fast, 150mm long of 12mmx3mm made to shape-04 Nos per window. (b) Handle of z section 20mmx25mm, 100mm long 01 Nos per leaf (c) MS tower bolt 150mm long-2 Nos per leaf (d) z section 20mmx25mm, 100mm long stopper - 01 No per leaf (f) MS pintal hinges of size 75mmx12mm- 2 Nos per leaf (g) Fabrication & fixing arrangement as per Drg No CEJZ/TD-06/07. Note: Wire mesh and painting shall be measured & paid separately under respective item of schedule.
Supply and fixing steel window 1.25 mm thick box type (primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises gauged skeleton shutter ERW sec 50mmx20mm and 1mm thick with two openable leaf consisting two Nos sash bars of T-section 20mmx3mm complete welded to frame with one verticle mulion of ERW box type T-section of size 60mmx25mm and 1.25mm thick incl cutting holes and making good dismantled portion PCC (1:2:4) type B-1 four Nos for each window) including following fittings welded to frame shutter: - (a) Hold fast, 150mm long of 12mmx3mm made to shape-04 Nos per window. (b) Handle of z section 20mmx25mm, 100mm long 01 Nos per leaf (c) MS tower bolt 150mm long-2 Nos per leaf (d) z section 20mmx25mm, 100mm long stopper - 01 No per leaf (f) MS pintal hinges of size 75mmx12mm- 2 Nos per leaf (g) Fabrication & fixing arrangement as per Drg No CEJZ/TD-06/07. Note: Glass pans and painting shall be measured & paid separately under respective item of schedule.
Steel ventilator with top hung shutter including hinges, steel peg stay, complete (For glazing only)
M&L for Preparing and applying one coat of red oxide primer and two coats of synthetic enamel paint over new steel Surfaces of any description, over 10cm in width or girth
M&L preparing old steel surfaces and applying one coat oil synthetic enamel paint over steel Surfaces of any description, over 10cm in width or girth
M&L for sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks.
S&F mild steel framed work such as guard bars/grills, grating etc with end of bars shouldered and/or riveted or forged into spikes and similar works including one shop coat of zinc chromate primer complete all as specified.
S & F PVC solid door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinfoced with MS square tube , supplying and fixing in opening as per specification and drawing.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisiting of frame made out of M.S. Tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixing in the frame at the site as per specification & drawing.
S&F pressed steel door frame with one or more rebate including necessary fixing lugs, hinges, lock stricking plate of size 125 x60mm
S&F 35 mm Factory made 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated..
S&F 2nd class hardwood 30 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats
S&F Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete.
S&F Floor door stopper of aluminium alloy body and tongue with cover plate length 140 mm , anodised, with hard drawn steel spring, fixed in floor all as specified and directed.
M&L for preparation of new wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint in any tint all as specified and directed by the Engr in Charge.
M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tint all as specified and directed by the Engr in Charge.
Supply & Fixing 100mm size butt hinges extruded aluminum alloy with galvanised mild steel hinge plate
S&F Aluminum anodized barrel tower bolt of extruded section of size 150mm
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F extruded Aluminum alloy handle fabricated of size 150mm
S&F 15mm angular stop valves, fancy type chromium plated, with long shank and cup(concealed) screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed .
S&F Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union 15 mm bore
S&F 15mm angular stop valves, fancy type chromium plated, with long shank and cup screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed .
S&F Bib tap fancy type cast copper alloy suitable for 15mm bore iron pipe with long body fancy type complete fixed in repairs .
S&F in replacement PVC connection 15mm dia and 45cm long with two Nos of brass check nuts and washers complete all as specified and directed.
Demolition and breaking up drain pipes AC/PVC pipe in event n.exc 150 mm dia including all fittings.
S & F 110 mm bore PVC (SWR) pipe of pressure rating 6kgf/cm2 single socketed in any length with rubber ring joints jointing with adhesive fixed in repair to wall/laid in trenches complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends in any radius complete all as specified and directed.
S&F PVC (SWR) junction single (single tee) equal or unequal, dia of pipe 110 mm complete all as specified and directed.
S&F Vitreous china wash hand basin (Oval shape) under counter type bowl type including waste coupling and pipe all as specifed and directed. Make: Parryware.
S&F vitreous china wash down water closet pan (pedestal pattern), white, including plastic seat cover closed pattern including bolts, flush pipe of polyethylene of low or high density PVC 32mm dia anti-syphonage pipe and suitable traps etc and connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe etc complete all as specified and as directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F vitreous china ware squatting pan ‘Orissa’ pattern size 580x440mm white with integral foot rest including connection to trap and flushing pipe, anti-syphonage pipe and suitable trap etc and making good to floor etc complete all as specified and as directed.
S&F in repair 10 litres capacity PVC valve less symphonic action type, flushing cistern, low level, white with inlet, ball valve, PVC flush pipe, float and handle including brackets complete all as specified.
S&F brass chromium plated towel rail 20 mm dia, 600mm long fixed with chromium plated brass screws wooden/plastic gutties complete all as specified and directed.
S&F in repair pillar taps, cast copper alloy with capstan heads chrominm plated fancy type, screwed down high pressure with or without lettered Hot or Cold with long screwed shank and fly nuts, srewed for iron pipe and fixed 15mm bore.
Supply and fixing in repairs chromium plated grating 100 mm dia circular, fixing with cement mortar 1:3 on Nahani or floor trap complete all as specified and directed.
Material and labour for 25mm dia mild steel pipe curtain rod, powder coated fixed with & including MS powder coated hooks/ brackets and decorative finials (at both side), shade as approved by GE complete all as specified includng fixing of long size rawl plugs in wall for MS hook complete all as specified and directed.
M&L for cement concrete type E-2, 1:5:10 (using 40 mm graded brick aggregate) as in sunken flooring.
M&L for 15mm thick cement screed in CM 1:3 admixed with integrd water proofing compound FOSROC’s complast X 421 IC @ 130ml per bag of cement incl a bonding coat of FOSROC”s Nito bond AR cement slurry/STP No 1 liquid @ 200ml per bag of complete all as specified.
M&L for applying two coats of SHALIMAR SUPER CRETE/NITOBOND water proofing coating on the entire surface of sunken portion all as specified .
M&L for 25 mm thick cement concrete type B-1, 1:2:4 (20 mm graded aggregate) to receive the top layer of tiles
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies , canopies , deck slabs and in shelves and the like complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, shelves , landing and similar work not exceeding 200 mm thick (horzontal or sloping) and to edges of concrete complete all as specified and directed
M&L granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
Carefully chipping, removing existing loose/ damaged concrete with plaster from Columns by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade making the edges straight and even and cleaning it by wire brush and then by air blower and removal of rubbish outside MoD land complete as specified and as directed by Engr-in-charge.
Cleaning all existing reinforcement bars in Columns with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar in two coats conforming to ASTM-B-117 & ASTM-G-60-86 and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturers instructions, all as specified and directed. The rust converter shall have a minimum pH of 7.5 and shall be able to convert both hematite and magnetite forms of rust shall pass 400 alternate immersion cycles in 3.5 % NaCl. (Mode of measurement: per sqm of breaking area of concrete.) Make: Asian Paints Apcorep Rust Rem or equivalent make approved by E-in-C's Branch.
Providing and applying anti-corrosive coating APCOREP RUSTCOAT RB (CSIR/CBRI know how) in 2 coats with time interval of minimum 6 hours. The coating shall have ECorr value of -45 mV against SCE in 3.5 NaCL for 100 hours and electrochemical evaluation of max 0.5 mA /cm2. This coating shall be applied over APCOREP RUSTREM coated rebars.
Providing & applying a coat of structural grade epoxy bond coat SmartCare Epoxy Bonding agent having excellent water and alkali resistance and has long tack free time of more than 120 minutes and shear bond strength of 4 MPa to the prepared concrete surface to be repaired / strengthened. This is applied prior to the application of polymer repair mortar / epoxy mortar / Micro concrete to have monolithic action between old concrete surface and new concrete surface
Drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 300 mm in staggered manner or along the crack line in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and directed.
Providing and Repairing the damaged concrete portion / Surface preparation with single component ready to use, repair mortar SMARTCAE REPAIR MORTAR capable of applying 20 mm avg. thick in single layer initially by hand and finishing with trowel, carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface Type: Ready to use single component Polymer modified repair mortar, Flexural Strength ASTM-C-348- Min.8 MPa, Bulk Density- 1.5 to 1.6, Compressive strength (Typical value) 1Day- 8 MPa Min, 28 Days- 40 MPa min,KIC (Critical Stress Intensity Factor): Increases by 50% for 15% dosage against control Fracture Energy (r1) Joules: Increases by 200% for 15% dosage.
M&L TMT Mild steel bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed by Engr-In-Charge.
Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors complete as specified & directed.
Taking down unserviceable Submain of any size as directed by Engineer-In-Charge.
Taking down main switch / DB as directed by Engineer-In-Charge.
M & L for sub main wiring with two single core PVC insulated and unsheathed cable 6 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of not less than 25mm in size complete with all accessories alongwith provn of 6 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire.(Three runs of cable and one run of conduit shall be measured as one length)
M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire including sunken type pressed steel terminal boxes of thickness 1.6 mm thick and plastic laminated white / coloured top sheet cover 3.0 mm thick for:
One light / fan controlled by one, one way switch.
One 3 pin socket out let 5 Amps on same board with other switches.
One 3 pin socket out let 5 Amps on the independent board.
Ditto all as per item No.5 about but with 2.5 sqmm multistranded copper multistranded conductor FRLS cable with 2.5 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board
S & F switch Piano 5 Amps, flush button type, SP, one way, 230 Volts, AC
S & F switch Piano 1 5 Amps, flush button type, SP, one way, 230 Volts, AC
S & F socket out let multipurpose 5 pin 5 Amps,230 Volts
S & F socket combination ,6 pin ,15 amps, flush type, multipurpose, 230 V
M & L ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified.
Supply , installation & commissioning MCB Distribution board VTPN 4 way double door, with MCCB 100 A 16 kA as Incoming all as specified and directed at site .
Supply and fix DB,double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar.
Supply and fix DB,double door, SPN 4 way for MCB, 240 volt with 200 amps rated bus bar.
S&F MCB SPN 32 to 63 Amps 240 volts
S&F MCB SP 6-32 Amps 240 volts
Supply and Fixing stepped socket type electronic fan regulator and connecting up complete all as directed by Engineer-In-Charge.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings incl 01x 09Watt LED Lamp complete all as specified and directed..
S&F LED tube light fitting 20W CRCA Box type including retrofit LED lamp 20 W with efficacy not less than 120 lumen/Watt with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed.
Fixing only old serviceable LED tube light fitting any type/size with 02 Nos gutties/screws complete all as specified and directed.
Supply & fixing in replacement LED street light fitting 35W including LED lamp pressure die cast aluminum IP66 with surge protection device of 10KV, IK7 LED (SEOUL) 6500K and connecting electrical to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed including bracket and fixing clamps etc.
M& L for XPLE UG Cable of size 35 Sqmm 4 Core all as specified and directed.
Excavation in trenches in soft/lose soil not exceeding 1.5 Mtr wide and not exc 1.5M depth for laying of UG cables and getting out all as specified and directed
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms thick of soil complete all as specified and directed.
M & L river sand in trenches as cable cushioning 8 cm below the cables and 15cm above the cable which is to be punned down to 10m all as specified and directed.only punned thickness will be measured.
Removing the surplus excavated materials/ soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed.
Supply and lay burnt bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed.
Supply and laying GI Tube Med grade 50mm dia all as specified and directed.
M&L for earthing complete with GI steel earth plate electrod 60x60cmx6.00mm thick bouried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to test point by using GI wire of dia 4 mm as earthing lead soldering/revated to earth plate at one end and connected DB by means of nut, bolts etc complete with PCC pit (1:3:6) type GI cover with handle funnel with watering pipe wire mess GI protection pipe for earthing lead all complete as specified and as per electric plate No.5 of SSR Part I
NATIONAL BUILDERS
nitin trading company
M/S Vinod Kumar
NIRMAL SINGH
BHARAT ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .