Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC L1 is Accepted | |
| 2 | L2₹29.6 L+₹22,770 (0.78%)Rejected-AOC | L2 | Rejected-AOC L1 is Accepted | |
| 3 | L3₹29.9 L+₹53,900.05 (1.83%)Rejected-AOC | L3 | Rejected-AOC L1 is Accepted | |
| 4 | L4₹30.1 L+₹67,907 (2.31%)Rejected-AOC | L4 | Rejected-AOC L1 is Accepted | |
| 5 | L5₹30.3 L+₹95,004.10 (3.23%)Rejected-AOC | L5 | Rejected-AOC L1 is Accepted |
Tender Value
₹28.0 L
EMD Value
₹55,920
Closing Date
15 Oct 2024, 6:00 pmClosed
Garrision Engineer 867 EWS
GE 867 EWS, C/O 99 APO, PIN 913867
PROVN OF RATION STORE AND FOL STORE AT AP ALAGARAH UNDER GE 867 EWS
2024_MES_676183_1
GE/867/TOKEN/50 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
Kalimpong
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 867 EWS
₹55,920
13 Dec 2024
24 Sept 2024
22 Oct 2024
24 Sept 2024
15 Oct 2024
8 Oct 2024
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil, complete all as specified and as directed.
Excavation over area in soft/loose soil not exc 1.5 mtr depth; for foundation etc. and getting out all, complete all as specified and as directed.
Excavation in trenches n exc 1.50m wide and not exc 1.50m deep for foundation and getting out in soft / loose soil, complete all as specified and as directed.
M & L for PCC (1:3:6), type C2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and as directed.
M & L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) in foundation filling and mass concrete, complete all as specified and as directed.
M & L Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm in soft / loose siol felling under floor, complete all as specified and as directed.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.50m above the starting point, complete all as specified and as directed.
Form work to sides of concrete foundations, footings, bases of columns and plinth beam and similer work etc in rough finished surfaces of concrete flat., complete all as specified and as directed.
M & L for form work to sides of pillars, posts, strurs,piers, columns and stanchions in rough finished surfaces of concrete in square, rectangular or polygonal, complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams, etc.for rough finished surface of flat concrete, complete all as specified and as directed.
M & L for Reinforced cement concrete (1:2:4) (nominal mix) type B-1 (using 20mm graded crushed stone aggregate) as in foundations, footings, plinth beam etc, complete all as specified and as directed.
M & L for Reinforced cement concrete (1:2:4) (nominal mix) type B-1 (using 20mm graded crushed stone aggregate) for columns, pillars, piers, post and struts, complete all as specified and as directed.
M & L for Reinforced cement concrete (1:2:4) (nominal mix) type B-1 (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed.
M & L for mild steel deformed bars 10mm dia and over cut to length bend to shape required incld cranking bending spirally for hooping for column, hooking ends and binding with and incld mild steel wire (annealed not less than 0.90mm dia or securing with clips, complete all as specified and as directed.
All as per item No.14 here in above but 5mm dia and over upto and incld 10mm dia in stirrups, spacer and binders, complete all as specified and as directed.
S & F for Roof trusses (Framed), trussed , purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections ) including distance pieces cleats etc FE-410W (Gde E-250) quality A, complete all as specified and as directed.
S & F for pre-painted galvalume alumininum zink coating GI based corrugated steel sheet 0.50 mm think of any colour having tensile strength of 550 Mpa as roof covering/cladding to wall fixed with tapping screws, complete all as specified and as directed.
S & F for pre-painted galvalume aluminum zinc coating GI plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as in ridge, complete all as specified and as directed.
M & L for precast cement concrete (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) block masonry with solid blocks 10cm in and setting in CM (1:6), complete all as specified and as directed.
M & L for 15mm thick rendering on fair faces of brick/ block work or concrete surface in CM (1:6), complete all as specified and as directed.
M & L for 20mm thick rendering in two layers of 10mm each on brick or block concrete masonry walls in cement plaster (1:4) with WPC incl finished even and smooth w/o using extra cement, complete all as specified and as directed.
M & L for preparation of new plastered surfaces of walls and applying two coat of OBD over a coat of chalk whiting, complete all as specified and as directed.
M & L for applying two coat of cement base paint over a coat of primer including preparation of newly plastered surfaces, complete all as specified and as directed.
S & F for GI frame work of size 605 x 605mm, for seamless celing comprising of GI perimeter chanel 0.55mm thick with two unequal flangesof 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and incl ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre, complete all as specified and as directed.
S & F for hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60 mm long and expansion hold fastener 12.5 mm dia 40mm long, complete all as specified and as directed.
M & L for 4 mm thick E- board ( Everest) non combustible moisture resistance plain building boards, fixed to timber/ GI aluminium frame work with screws as in ceiling, complete all as specified and as directed.
M & L for hardcore of gauge exc 63mm but n exc 100mm,deposited, spred and levelled in layers n exc 15 cm thick watered and rolled /rammed to a true surface, complete all as specified and as directed.
M & L for 100m thick plain cement concrete (1:4:8) type D-1 (40 mm graded crushed stone aggregate) as in sub base or sub flooring fininshing the surface even and rough to receive the topping layer, complete all as specified and as directed.
M & L for machine cut kota stone slab flooring 20 to 25 mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing incl 15 mm thick screed bed or bedding layer of cement mortar (1:6), complete all as specified and as directed.
M & L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including 15 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and as directed.
M & L for 75 mm thick PCC (1:3:6) type C-2 (40 mm greded crushed stone aggregate) for plinth protiction, path/steps etc to be finished fair and even, complete all as specified and as directed.
S & F for Pressed steel door frame for doors, size 165 x 60mm with one rebates incl necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed.
S & F for 35mm thick plain framed panelled shutter (any number of panels) of 2nd class H.W with panels of timber flat on both sides or of venerred particle boards medium density, wood particle board with commercial face veeners, complete all as specified and as directed.
S & F for Steel windows with side hung shutters incl projecting type hinges with steel handle, and steel peg stay complete with glazing bars, complete all as specified and as directed.
S & F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; framework of water tank,dunnage rack and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
S & F for 3.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane, complete all as specified and as directed.
M & L Preparation and applying two coat of synthetic enamel paint over one coat of red oxide primer on new steel surfaces, of any description, over 10cm width or girth not other wise described, complete all as specified and as directed.
M & L Preparation and applying two coat of synthetic enamel paint over one coat of pink primer on new wooden surfaces, of any description, over 10cm width or girth not other wise described, complete all as specified and as directed.
S & F for 200mm long aluminium anodised barrel tower bolts of extruded sections, complete all as specified and as directed.
S & F for 300 mm long aluminium alloy, anodised sliding door bolt with hasp and staple (bolt type ) and fixing clip of sheet cost or extruded section or cost aluminium alloy & fixed, complete all as specified and as directed.
S & F for 150mm long aluminium handle cost type anodised, complete all as specified and as directed.
M & L for PCC (1:3:6) type C-2, (using 40 mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and as directed.
M & L for 75 mm thick PCC (1:3:6) type C-2, (using 40 mm graded crushed stone aggregate) as in sub Base or sub flooring finishing the surface even and rough to receive the topping layer, complete all as specified and as directed.
M & L for machine pressed chequered cement concrete tiles of size 30cm x 30cm x 25 mm thick ad above, set jointed and pointed in neat slurry with grey cement and pigments in floors cut and polished over and incl 15 mm thick screed bed or bedding layer of mortar for lying floor finishes in cement plaster 1:6, complete all as specified and as directed.
M & L for plain cement concrete (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) in coping including weathering slightly rounded or chamfered angles and trotting, complete all as specified and as directed.
M & L for rised pointing to block masonry surfaces in cement mortar (1:4), complete all as specified and as directed.
Supply only 75mm bore PVC pipe (SWR) single socketed, in any length with rubber ring joints, complete all as specified and as directed.
M & L for hand picking (any thickness) at the back of walls and raising (or lowering) to the required level using pabbles or broken stone, complete all as specified and as directed.
M & L for 40 mm thick PCC (1:2:4) Type B1 (using 20 mm graded crushed stone aggregate) as in floor fininsh, complete all as specified and as directed.
M & L for sand filling in floors, complete all as specified and as directed.
S & F Steel rolling shutters, Thickness of laths in 1.25mm, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type etc, complete all as specified and as directed.
S & F Safety lever locks mild steel with 4 levers for rolling shutters, complete all as specified and as directed.
S & F Ball bearing for rolling shutters, complete all as specified and as directed.
S & F steel ventilator with top hung shutter fixed type including hinges, steel peg stay, complete all as specified and as directed.
M/L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed FRLS multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including sunken junction box not less than 3.0 mm thick concealed in wall, mounting accessories like switches, sockets fan regulators with 3.0 mm thick Laminated sheet top covers etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly, complete all as specified and as directed. Make : Polycab/KEI/Plaza/Havells
All as per item No.55 here – in – before but for one 3 / 5 -pin switch socket outlet 5 amps on independent board.
All as per item No.55 here – in – before but for one switch socket outlet 15 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable.
Supply and fix switch piano flush button, single pole, 5 amps, one way, complete all as specified and as directed. Make : Anchor/Havells/Plaza
Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal, complete all as specified and as directed. Make : Anchor/Havells/Plaza
Supply and fix switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type, complete all as specified and as directed. Make : Anchor/Havells/Plaza
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. Make : Crompton/Havells/Philips
S & F 9W LED Bulb suitable for B22 holder . System Efficacy should be > 85 lm/ W. PF > 0.9, The Lamp Should have Cool Daylight Color temp of 6500K, lumen output >800 lm, complete all as specified and as directed. Make: Philips/Wipro/Crompton
S & F lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting, complete all as specified and as directed.
S&F Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 4 way 240 Volts AC, complete all as specified and as directed. Cat Part No 5076 11 of Make- Legrand or equivalent in Siemens/Schindler.
Supply and fixing MCB Single pole and neutral 40 Amps capacity 10 KA 240 Volts 50 HZ, 'C' curve, complete all as specified and as directed. Cat part No 4086 18 of Make : Legrand or equivalent in Siemens/Schneider.
Supply and fix MCB single pole (SP), 10 kA of 5 -32 Amps capacity 240 Volts, 'C' curve, complete all as specified and as directed. Cat part no 4085 95 of Make : Legrand or equivalent in Siemens/Schneider
M&L for Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25/16 mm PVC cashing & capping medium grade ISI marked and conduit junction boxes, terminal boxes and incl all accessories fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor, complete all as specified and as directed. NOTE : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size cashing & capping with accessories shall be measured as one length.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I, complete all as specified and as directed.
S&F 1100 volt grade heavy duty PVC insulated stranded aluminium conductor cable of cross-sectional area 10 sqmm size (one twin core cable flat or circular served with inner sheathing of PVC tape and overall PVC sheathed) in service connections, suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire and testing on completion, complete all as specified and as directed. Make: PolyCab/Plaza/KEI/Finolex.
S&F aluminum strip 25 x 3.15 mm complete with saddles and fixing screws for roof / down conductor on porcelain/epoxy spacer insulatoror fixed on GI Pipe, complete all as specified and as directed.(Spacer insulator measured and paid separately under relevant items) . Note :- Rates quoted by the contractor are deemed to be included for cutting ,jointing pieces ofstrip with nut bold etc.
S&F porcelain/epoxy white / brown / green spacer insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding / fixing roof conductor / down conductor of lightning conductor, complete all as specified and as directed.
S&F single pointed air termination Copper rod 12-mm dia 300 mm long with fixing arrangement including dismantling of old unserviceable/ deshaped conductor and removed from site of work, complete all as specified and as directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and as directed.
M&L for earthing and material and labour for earthing complete wih galvanised steel earth plate electrode 60cmx60cmx6.00 mm thick burried directly in ground vertically toa depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level connected to and including galvanized iron earth strip of size 32x6 mm by means of bolts, nuts , chucknut, and washer etc , made of GI and connecting to earth test point all as shown as electrical plate to 5 of SSR Pt -1 2009 an as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C-I earthing chamber, precast RCC slab 50 mm thick in cement concrete (:) type B1 reinforced with welded steel wire fabricated weight not less than 4 Kg/ Sqm . Funnel with GI watering pipe 20 mm bore medium grade wire mesh test point etc, complete all as specified and as directed.
M& L for laying GI tubes light grade, 25 mm dia for protection of earth continuity leads, complete all as specified and as directed.
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
GEETA CONSTRUCTION (BID ID -3139772)
MS BRAHMA CONSTRUCTION (BID ID -3140416)
APARAJITA GROUP OF CONSTRUCTION (BID ID -3140454)
GYANENDRA THAPA (BID ID -3140407)
M/S JAYSHREE CONCERN (BID ID -3140344)
HEM RAJ GURUNG (BID ID -3140395)
MS MAYA PRAKASH GOEL AND SONS (BID ID -3140341)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .